  12742   Fri Jan 20 11:16:30 2017 gautamUpdateSUSMC1 SUS electronics investigationBoth suspensions have been relatively well
behaved for the best part of the last two
days, since I effected the Satellite Box
 MCglitchesReturn.png 
  12745   Mon Jan 23 10:24:01 2017 SteveUpdateSUSMC1 SUS electronics investigationTwo day plot of glitching suspentions:
MC3, ITMY and ETMX
 3glitchingSUS.png 
  12753   Wed Jan 25 10:46:58 2017 steveSummarySUSoplev laser summary updated                   
Oct.  5, 2015             
ETMY He/Ne
 oplev_sums.png 
  12760   Fri Jan 27 14:50:04 2017 SteveUpdateSUS wire standoffs updateThe 3 pieces of Sapphire
v-groove test cuts are back. They look
good. The suspension wire 0.0017" (
  
  12761   Fri Jan 27 15:36:17 2017 KojiUpdateSUS wire standoffs updateVery nice! I got excited.


Don't you ask Calum
and co to check the groove size with their
  
  12802   Mon Feb 6 10:05:28 2017 SteveUpdateSUSclamped cablesThe bottom 5 cable connections from Sat-Amp
to Whittering Filter at 1X5 were clamped
today.
 clamped.jpg 
  12811   Wed Feb 8 10:16:39 2017 steveUpdateSUSclipping ITMX oplevThe ITMX oplev beam is clipping. It will
be corected with locked arm

 
 ITMX_oplev_clipping.jpgITMX_clipping.jpg 
  12846   Thu Feb 23 09:32:20 2017 KojiUpdateSUS wire standoffs updateKyle took high quality images of 
the three sapphire prisms using the microscope
@Downs. He analyzed the images to see the
 Sapphire_prism_1(A015).pngSapphire_prism_2(A016).pngSapphire_prism_3(A014).png 
  12886   Tue Mar 14 10:40:30 2017 SteveUpdateSUSOSEM filters are inWe have 50 pieces in the clean cabinet.  filters.jpg 
  12889   Thu Mar 16 08:22:16 2017 SteveUpdateSUSETMX damping Finally I see what kicks the sus damping
off

 laser_power_glitch.png 
  12892   Fri Mar 17 15:30:39 2017 SteveSummarySUSoplev laser summary updated   
     March  17, 
2017        
 oplev_sums.png 
  12931   Fri Apr 7 13:46:23 2017 SteveUpdateSUSETMX enclosure feedthoughETMX enclosure feedtrouh cabeling corrected.  bad.jpggood.jpg 
  12933   Mon Apr 10 09:58:35 2017 SteveSummarySUSoplev laser summary updated 




  
  12941   Thu Apr 13 09:48:37 2017 SteveUpdateSUSITMY-UL and ETMX sensorsWhy ITMY UL can not see this earth quake?
SRM and PRM are misaligned. ETMX is still
not well.
 ITMY.pngITMY-UL.pngETMX?.png 
  12995   Wed May 17 08:19:59 2017 SteveUpdateSUS4.1M earthquake Sus dampings recovered. ETMY oplev needs
to be recentered.

 eq_4.1_SantaBarbara.png4.1m_Isla_Vista_CA.png 
  13030   Thu Jun 1 16:21:55 2017 SteveUpdateSUS wire standoffs updateRuby
wire standoff received from China. I
looked one of them with our small USB camera. 
  
  13039   Mon Jun 5 10:30:45 2017 SteveUpdateSUSruby wire standoff picturesAtm 1 & 5, showing the ruby R ~10 mm
as it is seated on Al SOS test mass

Atm. 2, 3 & 4  chipped
 A087_R.png.bmpA097_chipped_edges.png.bmpA099_cal_wire.png.bmpA101_cal_wire_43_micron.png.bmpAl_SOS_R39mm.jpg 
  13123   Mon Jul 17 16:22:01 2017 SteveUpdateSUSruby wire standoff picturesBluebean Optical Tech Limited of Shanghai
delivered 50 pieces red ruby
prisms
 contacting_ridge.bmpcontacting_ridge.png 
  13126   Wed Jul 19 12:47:43 2017 SteveSummarySUSoplev laser summary updated1103P, sn P893518 of  2013 vintage
is dead at the sus  fiber demo

  
  13128   Wed Jul 19 18:24:15 2017 ranaSummarySUSoplev laser summary updatedThe $1000 HeNe should not be used for illuminating
fibers.

You should purchase these (total
  
  13129   Fri Jul 21 08:05:07 2017 SteveSummarySUSred, blue, green laser diodes orderedAlso ordered 1 ea.

Blue
20mW
  
  13146   Thu Jul 27 22:42:24 2017 gautamUpdateSUSSeismic noise, DAC noise, and Coil Driver electronics noiseSummary:

 noiseComparison.pdfdeWhiteConfigs.zipnoiseComparison_resistances.pdf 
  13168   Sat Aug 5 11:04:07 2017 gautamUpdateSUSMC1 glitches returnSee Attachment #1, which is full (2048Hz)
data for a 3 minute stretch around when I
saw the MC1 glitch. At the time of the glitch,
 MC1_glitch_Aug42017.pngMC1_glitch_zoomed.png 
  13173   Tue Aug 8 20:48:06 2017 gautamUpdateSUSITMX stuckSomewhere between CDS model restarts   
  13178   Wed Aug 9 15:15:47 2017 gautamUpdateSUSMC1 glitches returnHappened again just now, although the characteristics
of the glitch are very different from the
previous post, its less abrupt. Only actuation
 MC1_glitch.png 
  13182   Thu Aug 10 09:31:57 2017 SteveUpdateSUSITMX sensor voltageThere must be some bad connection




 9daysITMX.pngvacGlitchITMX.png 
  13187   Thu Aug 10 21:01:43 2017 gautamUpdateSUSMC1 glitches debuggingI have squished cables in all the places
I can think of - but MC1 has been glitching
regularly today. Before starting to pull
 MC_QUAD_10AUG2017.jpgMCR_10AUG2017.jpg 
  13195   Fri Aug 11 12:32:46 2017 gautamUpdateSUSMC1 glitches debuggingAttachment #1: Free swinging
sensor spectra. I havent done any peak fitting
but the locations of the resonances seem
 MC1_freeswinging.pdfMC1_inmatrix.pngMC1_sensors.png 
  13196   Fri Aug 11 17:36:47 2017 gautamUpdateSUSMC1 <--> MC3About 30mins ago, I saw another glitch
on MC1 - this
happened while the Watchdog was shutdown.
 MC1_glitch_watchdog_shutdown.png 
  13199   Sat Aug 12 14:09:36 2017 gautamUpdateSUSGlitches stay on MC1Even
in the switched state, the glitches stayed
on MC1. 

The coil
 MC1_glitch.pngMC_12hr_trend.pngMC1_glitches_intermittent.png 
  13200   Sat Aug 12 22:35:22 2017 ranaUpdateSUSGlitches stay on MC1To add to Gautam's entry: we swapped
the cables at the coil driver side (these
are the ones that go from coil driver to
  
  13201   Sun Aug 13 01:35:09 2017 KojiUpdateSUSGlitches stay on MC1We used to have similar suspension excursion
at ETMX. This was the motivation to replace
the stand-offs from Al ones to ruby ones.
  
  13206   Mon Aug 14 20:01:38 2017 gautamUpdateSUSGlitches stay on MC1I don't think we can say for sure. I
was just talking to EricQ about this, he
said the glitches were often seen when changing
  
  13220   Wed Aug 16 19:50:17 2017 gautamUpdateSUSMC1 <--> MC3 switched backNow that all the CDS overview lights are
green, I decided to switch back the coil
driver outputs to their original state so
  
  13225   Thu Aug 17 11:17:49 2017 gautamUpdateSUSMC1 <--> MC3 switched backSeems like this modification didn't
really work. There were several large MC1
glitches, and one of them misaligned MC1
 MC1_misaligned.pngMC1_glitch.png 
  13226   Thu Aug 17 17:33:01 2017 gautamUpdateSUSMC1 <--> MC3 switched backthat's why the Autolocker clears the
outputs; we don't want to be holding
the offsets from the last ms of lock when
  
  13231   Mon Aug 21 09:08:54 2017 SteveUpdateSUStiny glitchesThey are synchronised tiny glitches. They
are not mechanical.
 
 glitches.png 
  13261   Mon Aug 28 10:51:21 2017 steveUpdateSUSETMX damping recovered   ETMX_restored.png 
  13265   Tue Aug 29 01:52:22 2017 gautamUpdateSUSTest mass actuator calibration[ericq, gautam]

Tonight,
 ALS_comparison.pdf 
  13267   Tue Aug 29 15:04:59 2017 gautamUpdateSUSETMY Oplev PIT loop gain changedLast night, while we were working on the
ALS, I noticed the GTRY spot moving around
(in PITCH) on the CCD monitor in the control
 ETMY_OLPIT.pdfGTR_comparison.pdf 
  13284   Fri Sep 1 08:25:08 2017 SteveUpdateSUSMC1 glitchingMC1, MC2 and MC3 damping turned off to
see glitching action at 9:57am

 MC1glitching.pngMC1kicks.png 
  13286   Fri Sep 1 16:27:39 2017 gautamUpdateSUSMC1 glitchingI re-enabled the MC SUS damping and IMC
locking for some IFO work just now.

  
  13392   Wed Oct 18 17:34:09 2017 gautamUpdateSUSASDCSummary:

The signal path for the ASDC signal
is AS55
  
  13417   Wed Nov 8 12:19:55 2017 gautamUpdateSUScoil driver series resistanceWe've been talking about increasing
the series resistance for the coil driver
path for the test masses. One consequence
 vthresh.pdf 
  13429   Thu Nov 16 00:14:47 2017 Udit KhandelwalUpdateSUSSOS Sapphire Prism designSummary:


SOS solidworks model is
nearly complete

Having trouble
  
  13430   Thu Nov 16 00:45:39 2017 gautamUpdateSUSSOS Sapphire Prism design 




  
  13523   Wed Jan 10 12:42:27 2018 gautamUpdateSUSETMX DC alignmentI've been observing this for a few
days: ETMX's DC alignment seems to drift
by so much that the previously
 ETMXdrift.png 
  13527   Wed Jan 10 18:53:31 2018 gautamUpdateSUSETMX DC alignmentI should've put in the SUSPIT and SUSYAW
channels in the previous screenshot. I re-aligned
ETMX till I could see IR flashes in the arm,
 ETMXdrift.png 
  13528   Wed Jan 10 22:19:44 2018 ranaUpdateSUSETMX DC alignmentBest to just calibrate the ETM OL in the
usual way. I bet the OSEM outputs have a
cal uncertainty of ~50% since the input matrix
  
  13589   Wed Jan 31 15:27:55 2018 gautamUpdateSUSSUS MEDM master screens updatedI've often gotten confused by the labeling
on the SUS MEDM screens about the coil "Vmon"
fields - they're labelled as "30
 NewSUSmaster.png 