40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 306 of 344  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  14843   Mon Aug 12 21:25:19 2019 KojiUpdateCDSMore bench test of c1iscaux1.

> Looking through the manual,
I found a recommendation (pg10) that the
  
  14844   Tue Aug 13 08:07:09 2019 gautamUpdateCDSP1--->P2This morning, I wanted to move the existing
cables going to the P1 connectors of the
iLIGO whitening boards to the P2 connector,
  
  14845   Tue Aug 13 14:36:17 2019 gautamUpdateCDSP1--->P2As it turns out, only one extra shroud
needed to be installed - I did this and migrated
the cables for the 4 whitening boards from
  
  14846   Thu Aug 15 18:54:54 2019 gautamUpdateALSALS sensing noise due to IMCSummary:

I came aross an interesting
suggestion by Yutaro that KAGRA's
 ALSsensingNoise.pdf 
  14847   Fri Aug 16 04:24:03 2019 ranaUpdateALSALS sensing noise due to IMCWhat about just use high gain feedback
to MC2 below 20 Hz for the IMC lock? That
would reduce the excess if this theory is
  
  14848   Fri Aug 16 16:40:04 2019 gautamUpdateCDS1Y3 work[chub,
gautam]
 newLook1Y3.JPGIMG_7803.JPGc1lsc_crashed.png 
  14849   Sat Aug 17 16:49:23 2019 gautamUpdateCDSMore 1Y3 workWork done today:


All ribbon cable connections
to the backplane of the 1Y2 Eurocrates were
 Screen_Shot_2019-08-17_at_3.00.57_PM.pngScreen_Shot_2019-08-17_at_3.12.23_PM.pngIMG_7804.JPGScreenshot_from_2019-08-17_17-04-47.png 
  14850   Mon Aug 19 14:36:21 2019 gautamUpdateCDSc1iscaux remaining workHere is what is left to do:


Strain relief of all cabling.
Chub will take care of this in the coming
 caseForSmallerFootprint.pdf 
  14851   Tue Aug 20 19:05:24 2019 KojiUpdateCDSMC1 (and MC3) troubleshootStarted the troubleshoot from the MC1 issue.
Gautam showed me how to use the fake PD/LED
pair to diagnose the satellite box without
 Screenshot_from_2019-08-20_17-26-01.pngScreenshot_from_2019-08-20_17-43-03.png 
  14852   Thu Aug 22 12:54:06 2019 KojiUpdateCDSMC1 glitch removed (for now) and IMC locking recoveredI have checked the MC1 satellite box and
made a bunch of changes. For now, the glitches
coming from the satellite box is gone. I
 7x 
  14853   Thu Aug 22 20:56:51 2019 KojiUpdateCDSMC1 glitch removed (for now) and IMC locking recoveredThe internal ribbon cable for the MC1 satellite
box was replaced with the one in the spare
box. The MC1 box was closed and reinstalled
  
  14854   Fri Aug 23 10:01:14 2019 gautamUpdateBHDOMC cavity geometry - some more modelingSummary:

I did some more investigation of
what the appropriate cavity geometry would
 modeContentComparison.pdfOMCtransComparison.pdf 
  14855   Fri Aug 23 18:46:17 2019 JonUpdateCDSc1iscaux remaining workI added the list of new c1iscaux channels
to /opt/rtcds/caltech/c1/chans/daq/C0EDCU.ini
  
  14856   Fri Aug 23 19:10:02 2019 JonUpdateCamerasGigE camera server is onlineFollowing the death of rossa, which was
hosting the only working environment for
the 
  
  14857   Sun Aug 25 14:18:08 2019 gautamUpdateCDSc1iscaux remaining workThere were a bunch of useless / degenerate
channels added - e.g. whitening gains which
are alreay burt-snapshot. Maybe there are
 Screen_Shot_2019-08-25_at_10.38.37_PM.png 
  14863   Fri Sep 6 16:38:24 2019 aaronUpdateALARMAlarm noise from smart-ups machine under workstation?There was an alarm sound from the Smart-UPS
2200 sitting under the workstation. I see
that the 'replace battery' light
  
  14864   Fri Sep 6 18:08:29 2019 ranaUpdateComputersAlarm noise from smart-ups machine under workstation?please no one touch
the UPS: last time it destroyed ROSSA.
Please ask Chub to order the replacement
  
  14868   Tue Sep 10 15:41:37 2019 aaronUpdateIOOWFS measurements[rika, aaron, rana]

We are getting the MC locked in
anticipation of making some WFS transfer
 Screenshot_from_2019-09-10_18-51-28.pngmctrend_190910.png 
  14869   Tue Sep 10 16:10:40 2019 ChubUpdate Rack UpdateStill removing old cable, terminal blocks
and hardware.  Once new strain reliefs
and cable guides are in place, I will need
 20190910_154018.jpg20190910_154006.jpg 
  14870   Tue Sep 10 17:26:49 2019 KojiUpdateCDSD1900068 SR785 accessory boxI picked up a unit of D1900068 SR785 accessory
box from Dean's office at Downs. 
 P_20190910_171859_1.jpg 
  14871   Wed Sep 11 10:26:56 2019 aaronUpdateIOOWFS measurementsGameplan

We should also have
a plan for the next couple weeks so we are
organized; heavily adapted
  
  14872   Wed Sep 11 14:37:43 2019 aaronUpdateIOOWFS measurements[aaron, rika]

We identified the Jenne laser and
found a long optical fiber that might be
 20190911_WFS.jpg20190911_WFS_2.jpg 
  14873   Thu Sep 12 09:49:07 2019 gautamUpdateComputerscontrol rm wkstns shutdownChub wanted to get the correct part number
for the replacement UPS batteries which necessitated
opening up the UPS. To be cautious, all the
 IMG_7943.JPG 
  14874   Thu Sep 12 12:42:31 2019 aaronUpdateIOOWFS measurements[rika, aaron]

At Seiji and Gautam's suggestion,
we added an additional RF photodiode (NewFocus
 WFS2_TFs.pdfD755499D-9FDF-4E2B-BFC1-016B459DD35D.jpeg 
  14875   Fri Sep 13 10:36:03 2019 aaronUpdateIOOWFS measurements[rika, aaron]

We are at it again. Rika is setting
up the TF measurement, I'm looking into
 TF-.pngWFS2_TFs.pdf 
  14876   Fri Sep 13 10:53:40 2019 aaronUpdateIOOWFS loop measurementsI'm scripting the WFS sensing matrix
measurements. I haven't really scripted
DTT before, so I'm trying to find documentation
  
  14878   Mon Sep 16 05:08:04 2019 ranaUpdateIOOWFS loop measurementsnot need to use DTT. I'm attaching
some half-finished notebooks that give the
gist.
 LSCsensingMatrix.ipynbASCsensingMatrix.ipynb 
  14880   Mon Sep 16 11:55:58 2019 rikaUpdateIOOWFS loop measurements[rika, aaron]

We aligned optics of WFS as it
was. Now auto-locker is working to lock MC.
  
  14882   Mon Sep 16 12:38:59 2019 aaronUpdateIOOWFS measurementsI wanted to make a zero model of this circuit
to get a handle on the results. I couldn't
import zero on pianosa, and I tried pip installing
  
  14883   Mon Sep 16 17:53:16 2019 aaronUpdateCamerasMC2 trans camera (?) rotatedWe noticed last week that the MC2 trans
camera has pitch and yaw swapped; I rotated
what I thought is the correct camera by 90
 47D6ED9C-BF21-4D6E-9947-284FE4A336F4.jpeg 
  14884   Mon Sep 16 19:29:24 2019 KojiUpdateCamerasMC2 trans camera (?) rotatedThe left one is analog and 90deg rotated.

See also: This
issue tracker
  
  14886   Tue Sep 17 09:41:48 2019 gautamUpdateIOOWFS loop measurementsLet's
not worry about C1LSC until the c1iscaux
  
  14887   Tue Sep 17 10:34:48 2019 aaronUpdateIOOWFS loop measurementsI'm using the notebooks from rana as
a starting point, and making a script to
measure and fill the WFS sensing matrix.
  
  14888   Tue Sep 17 10:47:44 2019 rikaUpdateIOOWFS loop measurements[aaron, rika]

Once stop the auto-locker and realigned
to make beam to get into QPD again.
 MC2.pdf 
  14889   Tue Sep 17 14:01:46 2019 gautamUpdateCDSdaqd fw deadFor some reason, the daqd_fw service was
dead on FB. This meant that no frames were
being written since Aug 23, which probably
  
  14891   Tue Sep 17 21:34:07 2019 gautamUpdateCDSdaqd fw dead no moreSummary:


Frames seem to
be written again.
 RTFEstatus.png 
  14893   Tue Sep 17 23:46:21 2019 KojiUpdateCDSLatch Enable Logic[Koji Gautam]

We continued to check the latch
logic. Today we found that latch.py didn't
 Screenshot_from_2019-09-17_23-39-35.png 
  14895   Wed Sep 18 12:40:09 2019 gautamUpdateCDSFast BIO Mapping at 1Y2INCORRECT
INFO IN THIS ELOG HAS BEEN REMOVED. SEE THIS
  
  14896   Wed Sep 18 14:45:52 2019 rikaUpdateIOOWFS loop measurements[aaron, rika]

Gettng TFs

In the data
we got yesterday, we can see some filter's
 Screenshot_from_2019-09-18_18-15-34.png 
  14897   Wed Sep 18 15:27:45 2019 gautamUpdateIOOTT cables need to be remadeSummary:

The custom ribbon cables piping
the coil driver board outputs to the eLIGO
 IMG_7945.JPG 
  14898   Thu Sep 19 09:39:30 2019 gautamUpdateIOOTT cables need to be remadeWhile debugging this problem, c1lsc models
crashed. I ran the reboot script this morning
to bring the models back. There was a 0x4000
 CDSoverview.png 
  14899   Thu Sep 19 11:26:18 2019 gautamUpdateIOOTT cables DON'T need to be remadeFalse
alarm - the mistake
was mine. Looking at the schematic
  
  14901   Thu Sep 19 21:23:51 2019 gautamUpdateCDSFast BIO splicing re-implemented at 1Y2[KA,
GV]
 1Y2_FAST_BIO_WIRING_MAP.pdfIMG_7949.JPGREFL165.pdf 
  14902   Fri Sep 20 11:39:04 2019 gautamUpdateOptical LeversETMX Oplev HeNe DeadWhile working on recovering interferometer
alignment, I noticed that the ETMX Oplev
SUM channel reported 0 counts. 
 ETMX_OLdead.png 
  14903   Fri Sep 20 12:55:02 2019 gautamUpdateCDSc1iscaux testingI was hoping that the dark / electronics
noise level on the LSC photodiodes would
be sufficient for me to test the whitening
  
  14904   Fri Sep 20 18:28:34 2019 gautamUpdateLSCY arm locking attemptI tried to lock the Y arm cavity length
to the PSL frequency using POY11_I as an
error signal. Even though I think the cavity
 POYlocking.png 
  14905   Mon Sep 23 10:49:34 2019 ranaUpdateCDSc1iscaux testing
I'd say permanently enable
AA and AI. There's no reason to turn
these off for usual channels. We can always
  
  14906   Wed Sep 25 20:10:13 2019 KojiUpdateCDSc1iscaux testing== Test Status ==
[none]
Whitening gain switching test
 testDetectMons_190925.pngtestIPPOS_190925.png 
  14907   Thu Sep 26 17:56:28 2019 KojiUpdateCDSsome rebootingYesterday (Sep 25) evening: I had to reboot
c1psl, c1iool0, and c1aux to recover nominal
IMC locking
  
  14908   Thu Sep 26 20:09:40 2019 KojiUpdateCDSc1iscaux testing== Test Status ==

[done]
Whitening gain switching test =>
 Wht1.pdfWht2.pdfWht3.pdfWht4.pdflock.png 
ELOG V3.1.3-