  2988   Wed May 26 04:14:21 2010 kiwamuUpdateGreen LockinglockedI guess
I succeeded in locking of the cavity with
 OLTF_endPDH.png 
  2992   Wed May 26 14:38:02 2010 KojiUpdateGreen LockinglockedCongratulation! Probably you are right,
but I could not get this is a real lock or
something else.
  
  3262   Wed Jul 21 19:11:18 2010 DmassUpdateGreen LockinglockedWhat did you use to filter the 2f components
from your error signal? A homemade low pass
or what?
  
  6942   Mon Jul 9 05:15:46 2012 yutaUpdateGreen Lockinglocked MI while ALS using ASDCI locked MI while both arm length are stabilized
at IR resonance. This could be done using
DC READOUT,
 FPMIALStrial20120709.png 
  4141   Wed Jan 12 01:39:49 2011 kiwamuUpdateLSClocked X arm[Suresh, Kiwamu]
  
  4007   Fri Dec 3 05:21:11 2010 kiwamuUpdateGreen Lockinglocked the laser to the cavityI succeeded
in locking the end green laser to X arm with
  
  8521   Thu May 2 00:34:57 2013 KojiUpdateLSClocking- Routine alignment
Locked the arm cavties. Ran ASS.
As this was not enough precise alignment
 Screenshot.pngScreenshot2.pngScreenshot3.png 
  15172   Wed Jan 29 00:29:43 2020 gautamUpdateLSClocking 2020The goal tonight was to go through the
locking scripts to see if I could recover
the state from November 2019, when I could
 PRFPMI_2020Jan.png 
  9456   Thu Dec 12 00:47:45 2013 DenUpdateLSClocking activityJenne, Den
Today we worked on PRM angular servos
and Y-arm ALS stabilization.
 POP_ASC.pdf 
  9462   Fri Dec 13 02:19:57 2013 JenneUpdateLSClocking activity[Jenne, Den]
Tonight we worked on tweaking
up the PRCL new ASC, and then PRMI+1 arm
 PRMI_Yarm_NewPRCLasc.pngtry_dc.pdf 
  9463   Fri Dec 13 02:30:22 2013 KojiUpdateLSClocking activityAccording to the measurement by Eric, the
X-arm green PDH UGF is too low. We still
have some room to increase the gain.
  
  9471   Sat Dec 14 02:51:47 2013 DenUpdateLSClocking activityI had a look on x,y arms stabilization
using ALS. Input green beam was misaligned
and I was loosing 00 every few minutes. I
 ETMY_DRIVE.pdfALS_RIN.pdfALS_IR.pdf 
  9480   Tue Dec 17 02:10:29 2013 DenUpdateLSClocking activityKoji, Den
Some results and conclusions from
tonight:
  
  9853   Fri Apr 25 03:14:46 2014 ericqUpdateLSClocking activity[ericq, Jenne, Zach]
We spent some time tonight trying
to push our CARM locking further, to little
  
  9855   Fri Apr 25 13:18:08 2014 Dark JamieUpdateLSClocking activity

    

       
            
 m10008_f1_bg.jpg 
  5754   Fri Oct 28 05:17:13 2011 kiwamuUpdateLSClocking activity : PZT1 is still railing Status update on the LSC activity:

 To see how good/bad the beam
  
  5474   Tue Sep 20 03:02:23 2011 KeikoUpdateLSClocking activity tonight Keiko,
Anamaria, Koji
We
  
  6080   Wed Dec 7 02:55:38 2011 kiwamuUpdateGreen Lockinglocking activity tonightNo
real progress.
  
  6166   Wed Jan 4 03:03:24 2012 kiwamuUpdateLSClocking activity tonight and beyondLast night and tonight, I was doing
a kind of rehabilitation -- locking PRMI
and DRMI with the new trigger system.
  
  429   Sun Apr 20 18:23:27 2008 ranaSummaryLSClocking attemptsI noticed that the adaptive FF for the MC
had stopped doing anything; this turned out
 quix.png 
  11513   Tue Aug 18 03:56:09 2015 ericqUpdateLSClocking effortsNow that the updated ALS is stable, and
the PRC angular FF is revived, I've been
working on relocking PRFPMI. While the RMS
 newALSref.pdfxCoh.pdfyCoh.pdf 
  4623   Wed May 4 13:45:56 2011 kiwamuUpdateLSClocking last nightLast night I was trying to calibrate the
MICH error signal and the actuators on BS
and ITMs.
  
  6471   Fri Mar 30 10:20:51 2012 kiwamuUpdateLSClocking last nightI was trying to make the DRMI lock more
robust.
Increasing the gains of the oplev
  
  15045   Fri Nov 22 00:54:14 2019 gautamUpdateLSClocking notes[KA, GV]

There was no shaking (that disturbed
the locking) tonight!
 ALSnoiseIncrease.pdf 
  4753   Fri May 20 03:01:17 2011 kiwamuUpdateLSClocking status(PRMI locking)
Since REFL11 has gone I tried locking
the PRMI with combination of REFL55 and AS55.
 Screen_shot_2011-05-20_at_2.50.00.png 
  5040   Wed Jul 27 01:58:23 2011 kiwamuUpdateLSClocking statusThrough some locking exercise   
  5041   Wed Jul 27 08:59:10 2011 SureshUpdateLSClocking status I had to realign PSL beam into the
MC in order to reobtain the MC lock. 
We lost lock at sometime around 8:30 AM on
 MC_RFPD_DCMon.png 
  5043   Wed Jul 27 10:10:12 2011 steveUpdatePSLlocking status 80 days: PMC is drifting  80dpmcMC.jpg 
  5665   Fri Oct 14 04:35:45 2011 kiwamuUpdateLSClocking tonightThe
lock of DRMI wasn't stable enough to measure
the sensing matrix. Failed. 
 Screen_shot_2011-10-14_at_4.24.01.png 
  442   Thu Apr 24 14:10:26 2008 robUpdateLockinglocking work[I]Rob, Johnnie[/I]

We made some progress on locking last night
  
  3773   Sun Oct 24 19:55:50 2010 kiwamuUpdateElectronicslonely RF amplifier on ITMX table(Rana, Kiwamu) 



  
  12385   Tue Aug 9 13:53:57 2016 babbottUpdateSEIlong Guralp EX cable repaired on the D-sub sideI checked out the cable that I
took from you, and all of the connections
  
  685   Wed Jul 16 17:51:58 2008 MashaUpdateAuxiliary lockinglong measurementI'm taking a measurement on the SR785 spectrum
analyzer at low frequencies, so I'm going
to leave it by the symmetric port table for
  
  686   Wed Jul 16 22:29:05 2008 MashaUpdateAuxiliary lockinglong measurement[quote]I'm taking a measurement on the SR785
spectrum analyzer at low frequencies, so
I'm going to leave it by the symmetric port
  
  2312   Mon Nov 23 10:11:03 2009 steveUpdatePEMlong term temp fluctuation of the 40m lab

    
        
 7ytemp.jpg 
  4801   Thu Jun 9 18:25:22 2011 kiwamuHowToCDSlook back a channel which doesn' exist any moreFor
some purposes I looked back the data of some
channels which don't exist any more.
  
  8524   Thu May 2 19:59:34 2013 JamieUpdateComputer Scripts / Programslookback: new program to look at recent past testpoint dataTo aid in lock-loss studies, I made a new
program called 'lookback', similar to 'getdata',
to look at past data.
  
  4692   Wed May 11 17:20:24 2011 kiwamuConfigurationIOOloop diabled on PZT2[Valera / Kiwamu]
 
  
  2105   Fri Oct 16 16:08:00 2009 robConfigurationASCloop opened on PZT2 YAW at 3:40 pmI pushed the "closed loop" button
on PZT2 YAW around 3:40 pm today, then roughly
recentered it using the DC Offset knob on
  
  2107   Fri Oct 16 18:46:36 2009 ranaConfigurationASCloop opened on PZT2 YAW at 3:40 pm

    
        
 Untitled.png 
  2109   Sun Oct 18 16:09:34 2009 ranaConfigurationASCloop opened on PZT2 YAW at 3:40 pm 
I wanted to see how long our IP POS
beam has been badly clipped - turns out its
 a.png 
  4752   Fri May 20 01:02:50 2011 loose connection hunterUpdateSUSloose connection on ETMY rackThe
UL signal of the shadow sensor on ETMY went
to zero this evening. 
 ETMY_loose.png 
  14290   Mon Nov 12 13:53:20 2018 ranaUpdateIOOloss measurement: oscope vs CDS DAQsstop using the ssscope, and just put the
ssssignal into the DAQ with sssssome whitening.
You'll get 16 bitsśšß.
  
  35   Wed Oct 31 08:34:35 2007 ranaOtherIOOloss measurementsIn the end, we were unable to get a good scatter
measurement just because we ran out of steam.
The idea was to get a frame
  
  14243   Thu Oct 11 13:40:51 2018 yukiUpdateComputer Scripts / Programsloss measurements


Quote:


  
  14245   Fri Oct 12 12:29:34 2018 yukiUpdateComputer Scripts / Programsloss measurementsWith Gautam's help, Y-arm was locked.
Then I ran the script "armloss_dcrefl_asdcpd_scope.py"
which gets the signals from oscilloscope.
  
  14248   Fri Oct 12 20:20:29 2018 yukiUpdateComputer Scripts / Programsloss measurementsI ran the script for measuring arm-loss
and calculated rough Y-arm round trip loss
temporally. The result was 89.6ppm. (The
  
  14251   Sat Oct 13 20:11:10 2018 yukiUpdateComputer Scripts / Programsloss measurements


Quote:


  
  14254   Mon Oct 15 10:32:13 2018 yukiUpdateComputer Scripts / Programsloss measurementsI used these values for measuring armloss:


Transmissivitity of ITM
= 1.384e-2 * (1 +/- 1e-2) 
Transmissivitity
 XARM_20181015_1500.pdfYARM_20181015_1500.pdf 
  14258   Tue Oct 16 00:44:29 2018 yukiUpdateComputer Scripts / Programsloss measurementsThe scripts for measuring armloss are in
the directory "/opt/rtcds/caltech/c1/scripts/lossmap_scripts/armloss_scope".


armloss_derefl_asdcpd_scope.py:
  