40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 304 of 341  Not logged in ELOG logo
ID Date Author Type Category Subjectup Text Attachments
  14259   Wed Oct 17 09:31:24 2018 SteveUpdatePSLmain laser offThe main laser went off when PSL doors
were opened-closed. It was turned back on
and the PSL is locked.
 Inno2wFlipped_off.png 
  3549   Thu Sep 9 08:23:45 2010 steveUpdateSAFETYmain laser turned offInnolight 2W 1064nm main laser was turned
off for more enclosure related work.
The electrician re rooting the power-
  
  4493   Wed Apr 6 18:55:49 2011 Jamie, LarisaConfigurationLSCmajor AP table cleanupWe ripped out all of the old AS, PLL, and
REFL paths, green, orange, and cyan respectively
on the old
  
  8549   Wed May 8 17:03:35 2013 JamieConfigurationCDSmake direct IPC connections between c1lsc and c1sus/c1mcsPreviously, for some reason, many IPC connections
were routed through the c1rfm model, even
if a direct IPC connection was possible. 
  
  3785   Tue Oct 26 12:45:20 2010 yutaHowToCDSmaking a new master file for medm screens(Joe, Yuta)

 In elog
  
  14799   Mon Jul 22 21:04:40 2019 ranaUpdateComputersmaking rossa great again
copied over /etc/fstab lines from
pianosa sothat the NFS mounts work correctly
added
symlinks so that the NFS dirs mount in the
 seis.pdf 
  14831   Tue Aug 6 14:12:02 2019 yehonathanUpdateComputersmaking rossa great againcdsutils is not working on rossa.

Import cdsutils produces this error:

In [2]: import cdsutils
  
  5124   Fri Aug 5 14:03:12 2011 steveUpdateGeneralmalfunctioning crane at ETMYThe horizontal trolley drive stopped working 
at the east end this morning. It is working
intermittently. In the worst case we can
  
  5193   Thu Aug 11 15:31:43 2011 steveUpdateGeneralmalfunctioning crane at ETMY

    

       
            
  
  2138   Fri Oct 23 15:02:00 2009 robUpdateloremarconi phaseSo, it appears that one doesn't even have
to change the Marconi set frequency to alter
the phase of the output signal.  It
  
  2139   Sat Oct 24 04:57:33 2009 ranaUpdateloremarconi phase


   
        
            
  
  1019   Thu Oct 2 02:45:50 2008 robUpdateLockingmarginally betterLocking the DRMI with the +f2 sideband was
marginally better tonight.  I was able to
get it lock stably enough to take transfer
  
  3627   Thu Sep 30 14:09:33 2010 yutaUpdateComputersmariabella connects to the wireless networkBackground:
 We need laptops that connect
to the wireless network to use them in the
  
  10456   Fri Sep 5 03:36:00 2014 ranaUpdateComputer Scripts / Programsmartian wireless tweak I changed the Martian wireless router
to use channel 10 instead of something random
(as it was). Using the Android app 'Wifi
  
  1682   Wed Jun 17 01:07:50 2009 robConfigurationComputersmatapps on /cvs/cdsI checked out a copy of matapps into /cvs/cds/caltech/apps/lscsoft
so that I could find the matlab function
strassign.m, which is necessary for some
  
  5019   Fri Jul 22 15:39:55 2011 haixingUpdateSUSmatching the magnetsYi Xie and Haixing, 
We used the Gauss meter to measure
the strength distribution of bought magnets,
  
  1971   Mon Sep 7 23:51:48 2009 ranaConfigurationComputersmatlab installed: 64-bit linuxI have wiped out the 2008a install of 64-bit
linux matlab and installed 2009a in its place.
Enjoy.
  
  9318   Wed Oct 30 08:32:55 2013 EvanHowToComputer Scripts / ProgramsmatplotlibrcFYI, you can trick out matplotlib by creating
a matplotlibrc config
  
  3494   Tue Aug 31 11:50:14 2010 kiwamuUpdateCDSmaximum number of BIOs { Joe and Kiwamu },
 
  
  4355   Fri Feb 25 01:48:54 2011 valeraUpdateASCmc auto alignment status I made several scripts to handle
the mcass configuration and sensing measurements:
- The scripts and data are in the 
 mcditherlines.pdfmcdecenter.pdfmcmirror.pdf 
  1335   Tue Feb 24 18:42:15 2009 peteUpdateLockingmc board repairPeter, Yoichi
Last night:
  
  17004   Thu Jul 14 19:56:15 2022 ranaUpdateIOOmc wfs demodIt looks like Tomislav's measurements
of the WFS demod board noise were actually
of the cable that goes from the whitening
 mcwfs-steps.pdf 
  15171   Wed Jan 29 00:27:13 2020 gautamUpdateComputer Scripts / Programsmcup / mcdown modifiedTo fix the apparent slowness of execution
of the caput
  
  596   Sun Jun 29 20:09:40 2008 JohnSummaryIOOmcup and mcdown indicatorsI edited the mcup and mcdown scripts so that
C1IFO_STATE shows when these scripts are
running.
 mcscreen.pngifostate.png 
  1055   Fri Oct 17 16:43:10 2008 YoichiConfigurationComputersmcup/down scripts on linuxI made some changes to /cvs/cds/caltech/medm/c1/ioo/cmd/medmMCup
and medmMCdown so that those can be run from
medm on linux machines.
  
  2043   Fri Oct 2 15:24:29 2009 sanjit, ranaSummaryIOOmcwfs centeredwe set the offsets for the MCWFS DC and
for the MCWFS demod outputs and then turned
off the lights put the MZ at half fringe
 Untitled.png 
  6967   Thu Jul 12 13:27:16 2012 yutaUpdateSUSmeasured OLTFs of PRMI optics' SUSPOSI measured openloop transfer functions
of PRM/BS/ITMX/ITMY SUSPOS servo.
They look great. They all have ~50
 PRMSUSPOSOLTF.pngBSSUSPOSOLTF.pngITMXSUSPOSOLTF.pngITMYSUSPOSOLTF.png 
  3667   Thu Oct 7 14:39:50 2010 yutaUpdatePSLmeasured PMC's laser power-output relation(Rana, Yuta)

Motivation:
 PMCreflect.png 
  3669   Thu Oct 7 15:05:46 2010 KojiUpdatePSLmeasured PMC's laser power-output relationIt was a bit difficult to comprehend the
result.
Is it good? or bad? Have you seen
  
  3672   Thu Oct 7 16:34:06 2010 yutaUpdatePSLmeasured PMC's laser power-output relationResult2:
 Attached is the visibility vs
incident power(assuming output of the PD
 PMCvis.png 
  4086   Wed Dec 22 11:24:23 2010 haixingUpdateSUSmeasurement of imbalance in quadrant maglev protopeYesterday, a sequence of force and gain
measurement was made to determine the imbalance
in the
 config_2x2.png 
  5659   Thu Oct 13 03:22:53 2011 kiwamuUpdateLSCmeasurement of sensing matrix : just began- status update on LSC activity :
The
measurement of the LSC sensing matrix has
  
  5684   Tue Oct 18 04:04:27 2011 kiwamuUpdateLSCmeasurement of sensing matrix : touchy SRMI made
some attempts to measure the sensing matrix
  
  5400   Wed Sep 14 01:17:51 2011 kiwamuUpdateLSCmeasurement of spot position on Y armThe spot
positions on ITMY and ETMY were measured
 misposition.png 
  5406   Wed Sep 14 15:00:00 2011 kiwamuUpdateLSCmeasurement of spot position on Y armForgot to attach a picture of the ITMY's
face camera when it was locked. 
 DSC_3408_small.jpg 
  4367   Wed Mar 2 16:51:53 2011 steveConfigurationGreen Lockingmech shutter in place at the south endI moved old POX shutter from ITMY optical
table to the south end. MEDM POX mechanical
shutter screen is now closing the green beam 
  
  4626   Wed May 4 13:57:04 2011 kiwamuUpdateSUSmechanical resonances updated[Leo  w/ a little help from Kiwamu]
Leo
summarized the mechanical resonances of all
  
  12207   Tue Jun 21 11:26:42 2016 varunFrogsCDSmedm command not working"medm: command not
found" error when run through
  
  12208   Tue Jun 21 11:49:29 2016 ericqFrogsCDSmedm command not workingThe workstations' .bashrc
is a symbolic link to /users/controls/.bashrc

In it, someone commented out the
  
  1318   Wed Feb 18 03:25:25 2009 YoichiUpdateComputersmedm directory backI restored the medm directory from the backup
on the tape.
The directory had an svn property svn:ignore
  
  6162   Tue Jan 3 18:40:08 2012 AidanSummaryComputer Scripts / Programsmedm directory clean-up I moved the following old and obsolete
MEDM directories to an archive /cvs/cds/rtcds/caltech/c1/medm

    c1vga
    c1vgl
  
  6169   Wed Jan 4 11:47:08 2012 JamieSummaryComputer Scripts / Programsmedm directory clean-up


   
        
            
  
  1307   Mon Feb 16 00:43:46 2009 ranaUpdateComputersmedm directory wiped on nodus[COLOR=red][B]I accidentally did an 'rm -rf'
on the medm directory in nodus[/B][/COLOR],
instead of on my laptop as was intended.
  
  1310   Mon Feb 16 15:54:07 2009 YoichiUpdateComputersmedm directory wiped on nodus[quote][COLOR=red][B]I accidentally did an
'rm -rf' on the medm directory in nodus[/B][/COLOR],
instead of on my laptop as was intended.
  
  1311   Mon Feb 16 16:26:29 2009 robUpdateComputersmedm directory wiped on nodus[quote][quote][COLOR=red][B]I accidentally
did an 'rm -rf' on the medm directory in
nodus[/B][/COLOR], instead of on my laptop
  
  10898   Tue Jan 13 23:17:57 2015 ChrisFrogsComputer Scripts / Programsmedm time machineAfter recompiling medm with a patch for
dumping screens (attached), I added a time
machine to the right-click Execute menu. 
 tm.pngdump_medm_screen.patch 
  1041   Fri Oct 10 20:03:35 2008 YoichiConfigurationComputersmedm, dataviewer, dtt on 64 bit linuxI compiled EPICS (base, medm and ezca) and
dataviewer for 64 bit linux.
These are installed in /cvs/cds/caltech/apps/linux64/.
  
  7104   Tue Aug 7 15:01:38 2012 JenneUpdateComputer Scripts / Programsmedmrun now allows args to pass to scriptsPreviously, medmrun didn't accept arguments
to pass along to the script it was going
to run.  Jamie has graciously taken
  
  12093   Wed Apr 27 14:06:31 2016 ranaSummaryGeneralmeeting notes
Gautam will get
help from Johannes and finish EX table by
Monday.
Steve
  
  6585   Mon Apr 30 18:46:34 2012 ranaUpdateComputersmegatronLast week I found that megatron was still
off after the power outage. Apparently, the
power recovery checklist had not been followed
  
ELOG V3.1.3-