  15454   Mon Jul 6 12:43:02 2020 ranaUpdateComputersrossa: lib symlinkyes, I rebooted yesterday to fix the 'steaking
white lines' problem in the video/display

maybe we're supposed to edit
  
  15473   Mon Jul 13 11:33:18 2020 ranaUpdateComputersrossa: more developmental workI too, would prefer py3 for everything,
but aren't all the cdsutils / gaurdian
things still python2?
  
  15474   Mon Jul 13 11:36:08 2020 ranaUpdateLSCMC2 coils need DC balancing?
if IMC REFL is not increasing,
I don't think its a mis-alignment. Usually,
REFL is a more sensitive indicator of alignment
  
  15505   Wed Jul 29 11:57:59 2020 ranaUpdateBHDIn-air BHD - CDS and wiring summary3. I agree - this whitening will be handy
to have for diagnostics.

4. I think in principle, we can
  
  15509   Fri Aug 7 11:23:47 2020 ranaUpdateBHDMonte Carlo Simulationsthat's great. I think we would like
to figure out how to present this so that
its clear what the distribution of TFs is.
  
  15533   Tue Aug 18 13:55:23 2020 ranaUpdateALSWhitening and ALS noiseNo, there should be no unscheduled visits
from any inspector, marshal, tech, or vendor.
They all have to be escorted or they don't
  
  15546   Sat Aug 29 18:52:42 2020 ranaUpdateIOOIMC gain changeI lowered
the (FAST) PZT gain on the IMC/FSS servo
today.
  
  15547   Sat Aug 29 20:07:48 2020 ranaUpdateElectronicsWFS characterizationI set up to do the WFS head modifications
today, but I was shot down in flames due
to a missing AC/DC adapter.
  
  15550   Sun Aug 30 11:29:33 2020 ranaUpdateGeneralpower blink?My power at home winked out for a second
this morning, but it looks like either nothing
happened in the 40m lab or else it rode it
  
  15566   Wed Sep 9 20:52:45 2020 ranaSummaryIOOwandering line in IMCsince the summary pages are working again,
I was clicking through and noticed that there's
a wandering peak in the whitened IMC spectrogram
  
  15574   Tue Sep 15 19:17:30 2020 ranaUpdateIOOMC F spectrum that's a very curious disconnection

the "Pentek" whitening
board that carries the MC channels has jumpers
  
  15581   Sat Sep 19 11:27:04 2020 ranaUpdateGeneralM4.5 EQ in LAthe seismometers obviously saturated during
the EQ, but the accelerometers captured some
of it. It looks like there's different
 Sep18-EQ.pdf 
  15583   Sat Sep 19 18:08:34 2020 ranaUpdateGeneralM4.5 EQ in LAthe EQ was ~14 km south of Caltech and
17 km deep

  
  15589   Sun Sep 20 23:12:13 2020 ranaSummaryALSALS noise budget updateI think the digital loop in the ALS budget
is too optimistic. You have to include all
the digital delays and anti-aliasing filters
  
  15594   Tue Sep 22 12:14:42 2020 ranaSummaryALSALS noise budget updateThis ALS loop is not stable. Its one of
those traps that comes from using only the
Bode plot to estimate the loop stability.
  
  15605   Wed Sep 30 19:45:56 2020 ranaUpdateGeneralHEPA blower startup capacitor replacementit would be a good idea for us to have
an auto-reminder to have us check the flow
of all the HEPAs in the lab and elog it once
  
  15638   Thu Oct 22 13:04:42 2020 ranaUpdateElectronicsHV coil driver packaged into 2U chassiswhat is the noise level before the HV stage?
i.e. how well is the acromag noise being
filtered?
  
  15671   Tue Nov 10 15:13:41 2020 ranaUpdateGeneralETMY suspension eigenmodesFor the input matrix diagonalization, it
seemed to me that when we had a significant
seismic event or a re-alignment of the optic
  
  15677   Mon Nov 16 00:02:34 2020 ranaUpdateElectronicsMore systematic noise characterizationtrue. also try to choose a cap with a goow
high frequency response. In the Electronics
Noise book by Ott there's some graph
  
  15679   Tue Nov 17 00:26:32 2020 ranaUpdateElectronicsSR560s in need of repair/battery replacementyes, both problems can be fixed. Usually
we just order some spare lead-acid batteries
from SRS (Steve may have some spare ones
  
  15691   Sat Nov 28 21:44:53 2020 ranaUpdateASCPlanned mods for WFS headI don't think your simulation looked
inaccurate (at least not to me). In my opinion,
we just want to minimize any excess noise
  
  15700   Thu Dec 3 11:02:35 2020 ranaUpdateElectronicsElectrical LO signal for AS WFSlooks good to me.

The thing I usually look for is
how much the downstream system (mixers, etc)
  
  15732   Fri Dec 11 09:28:52 2020 ranaUpdateBHDMonte Carlo loop coupling SimulationsCool. Can you give us Bode plots of the
open loop gain for each of the 5 length control
loops?
  
  15759   Mon Jan 11 19:10:10 2021 ranaUpdateBHDMonte Carlo loop coupling Simulations
looking better, but the CARM plot
still looks weird.
you should
plot from 0.01 - 10,000 Hz
All
  
  15804   Thu Feb 11 16:58:52 2021 ranaSummaryBHDSatellite Amplifier Very Low frequency noise After modificationsI expect that a single OSEM channel can't
be better than 1e-10 m/rHz above 5 Hz, so
probably something wrong in the calibration.
  
  15827   Fri Feb 19 18:22:42 2021 ranaUpdateLSCPRFPMI sensiing matrix woesI would:


look at the free swingin
michelson. Should be able tu null that siggnal
  
  15831   Sun Feb 21 20:51:21 2021 ranaUpdateGeneralHousekeeping + PRMI charI'm curious to see if the demod phase
for MICH in REFL & AS chamges between
thi simple Mcihelson and PRMI. IF there's
  
  15854   Tue Mar 2 13:39:31 2021 ranaUpdateLSCPRM violin filter excessive?agreed, seems excessive. I always prefer
bandstop over notch in case the eigenfrequency
wanders, but the bandstop could be made to
  
  15881   Mon Mar 8 19:22:56 2021 ranaSummarySUSIMC suspension characterizationHerewith,
I describe an adventure
  
  15882   Mon Mar 8 20:11:51 2021 ranaFrogsComputer Scripts / Programsactivate_matlab out of control on Megatronthere were a zillion processes trying to
activate (this is the initial activation
after the initial installation) matlab 2015b
  
  15914   Fri Mar 12 13:01:43 2021 ranaSummarySUSCoil Rs & Ls for PRM/BS/SRMugh. sounds bad - maybe a short. I suggest
measuring the inductance; thats usually a
clearer measurement of coil health
  
  15921   Mon Mar 15 20:40:01 2021 ranaConfigurationComputersinstalled QTgrace on donatella for dataviewerI installed QTgrace using yum on donatella. Both Grace and  cutiegrace.png 
  15938   Thu Mar 18 12:35:29 2021 ranaUpdatesafetyDoor to outside from control room was unlockedI think this is probably due to the safety
tour yesterday. I beleive Jordan showed them
around the office area and C&B. Not sure
  
  15939   Thu Mar 18 12:46:53 2021 ranaUpdateSUSTesting of new input matrices with new dataGood Enough! Let's move on with output
matrix tuning. I will talk to you guys about
it privately so that the whole doesn't
  
  15942   Thu Mar 18 21:37:59 2021 ranaUpdateLSCPRMI investigations: what IS the matrix??
Locked PRMI several tmes after
Gautam setup. Easy w IFO CONFIG screen
 PXL_20210319_045925024.jpg 
  15950   Sun Mar 21 19:31:29 2021 ranaSummaryElectronicsRTL-SDR for monitoring RF noise / interferenceWhen we're debugging our RF system,
either due to weird demod phases, or low
SNR, or non-stationary noise in the PDH signals,
 Screen_Shot_2021-03-21_at_7.43.24_PM.png 
  15952   Mon Mar 22 15:10:00 2021 ranaUpdateSUSTrying coil actuation balanceThere's an integrator in the MC WFS
servos, so you should never be disabling
the ASC inputs in the suspensions. Disabling
  
  15975   Mon Mar 29 17:34:52 2021 ranaUpdateSUSMC2 Coil Balancing updatesI think there's been some mis-communication.
There's no updated Hang procedure, but
there is the one that Anchal, Paco and I
  
  16010   Fri Apr 9 17:41:12 2021 ranaUpdateSUSFaster coil balancingconvergence is great.

Next we wanna get the F2A filters
made since most of the IMC control happens
  
  16014   Sat Apr 10 10:07:47 2021 ranaUpdateSUSFaster coil balancingI think I mis-spoke about the balancing
channels before. The ~20 Hz balancing
could go into either the COIL banks or the
  
  16020   Tue Apr 13 09:51:22 2021 ranaUpdateSUSWhat's F2A??Force to Angle. It just means the filters
that are in the POS OUTPUT matrix. I think
in the past sometimes they are called F2P
  
  16029   Wed Apr 14 15:30:29 2021 ranaUpdateGeneralSorry, it was meMaybe tighten the tensioner on the door
closer so that it closes by itself even in
the low velocity case. Or maybe just use
  
  16041   Fri Apr 16 11:31:00 2021 ranaUpdateelogelog stuck ~10 AM todayfound it unresponsive. Restarted fine using
procedure documented in wiki
  
  16043   Fri Apr 16 15:47:58 2021 ranaUpdateSUSTested proposed filters for POS colum in MC2 output matrixLooks mostly right, but you
used the OSEM sensors as readbacks.
  
  16046   Sun Apr 18 21:29:55 2021 ranaUpdatePSLLaser amplifier
Ideally, we put the chiller outside
of the interferometer area. The PSL chiller
used to be in the control room near the door
  
  16060   Wed Apr 21 10:59:07 2021 ranaSummaryCamerasnote on new GigE cam @ 1064Note
from Stephen on more sensitive Baslers.
  
  16067   Wed Apr 21 18:49:29 2021 ranaUpdateSUSMC2 Suspension Optimization summarythe
POS column should be all 1 for the AC balancing.
  
  16084   Sun Apr 25 21:21:02 2021 ranaUpdateCDSSUS simPlant model
I suggest not naming this the LSC
model, since it has no LSC stuff.
Also
remove all the diagnostic stuff in the plant
  
  16141   Fri May 14 17:45:05 2021 ranaUpdatePSLHEPA speed raisedThe PSL was too hot, so I turned on the
south HEPA on the PSL. The north one was
on and the south one was off (or so slow
  
  16144   Tue May 18 00:52:38 2021 ranaUpdatePSLHEPA speed raisedLooks like the fan lowered the temperature
as expected. Need to get a few more days
of data to see if its stabilized, or if that's
 Untitled.png 