  17229   Fri Nov 4 15:43:05 2022 JCUpdateLab OrganizationNew Toolbox OrganizationThe new tool box has came in! I have spent
serious time organizing these tools and making
it look pretty, so please take care of it!
 IMG_6405.JPG 
  17230   Mon Nov 7 08:36:10 2022 JCUpdateSUSIMC out of alignment -- f2A failure[Paco, JC]

We came in this morning and noted
the IMC was grossly misaligned, with 
  
  17258   Fri Nov 11 19:11:50 2022 JCUpdateGeneralWFS Whitening and Demod BoardsWFS Whitening and Demod boards were scavenged.
 IMG_6419.JPGIMG_6424.JPG 
  17275   Thu Nov 17 07:39:01 2022 JCConfigurationCamerasITMX CameraComing in this morning, I found ITMX Camera
malfunctioning.
  
  17276   Thu Nov 17 09:06:35 2022 JCSummaryGeneralLight ReplaceElectrical Shop came in today to replace
the lightbulbs around 40m. I supervised the
entire visit, inside and outside the lab
  
  17277   Thu Nov 17 11:24:39 2022 JCHowToLSCLocking MICH[Yuta, JC]

Here is the Yuta's Alignment
Scheme from elog
  
  17280   Thu Nov 17 15:53:47 2022 JCConfigurationCamerasITMX Camera -- attempt at fixThe issue was the power supply.

  
  17283   Fri Nov 18 09:00:27 2022 JCUpdateVACPressure Gauge InformationI bought the spare Full-Range Pirani Gauge
a while ago and realized that I never logged
this. The Pirani Gauges we are using is described
  
  17290   Mon Nov 21 09:13:31 2022 JCUpdatePSLPMC input beam aligned again, IMC [JC, Paco]

I attempted to align PMC Beam from
a transmission of 0.72. I failed to do so
  
  17292   Mon Nov 21 14:55:58 2022 JCConfigurationGeneralLED Instead of Incandescent Lights Electrical came by today to see the lights.
The issue may be the switches, but they will
come by tomorrow to solve the issue. A couple
  
  17297   Tue Nov 22 08:56:27 2022 JCUpdatePSLPMC input beam alignment[Paco, Anchal, JC]

C1:PSL-PMC_PMCTRANSPD ~ 0.715 this
morning, this was increased to ~0.730. There
 Screenshot_from_2022-11-22_08-58-45.png 
  17307   Wed Nov 23 17:21:44 2022 JCUpdateVACInterlocks may have been tripped due to N2 pressure loss[Paco, JC]

While changing out one of the N2
tanks today, one of the fitting stripped.
 Screen_Shot_2022-11-23_at_5.22.57_PM.pngScreen_Shot_2022-11-23_at_5.23.09_PM.png 
  14049   Tue Jul 10 16:59:12 2018 Izabella PastranaHowToComputer Scripts / ProgramsTaking Remote TF Measurements with the Agilent 4395AI copied the netgpibdata folder
onto rossa (under the directory ~/Agilent/),
which contains all the necessary scripts
  
  4968   Thu Jul 14 17:34:35 2011 Ishwita, ManuelHowToWienerFilteringWiener-Hopf equationsSince we are using Wiener filtering in
our project, we studied the derivation of
Wiener-Hopf equations. Whatever we understood
 derivwf.pdf 
  4979   Sat Jul 16 18:54:05 2011 Ishwita, ManuelConfigurationElectronicsAA boardWe fixed the anti-aliasing board in its
aluminum black box,  the box couldn't
be covered entirely because of the outgoing
 DSC_3236.JPGpic1.pngDSC_3237.JPG 
  4999   Wed Jul 20 11:42:47 2011 Ishwita, ManuelUpdate Weekly summary
    We gave a white-board presentation
on derivation of formula for optimum Wiener
filter coefficients and wrote a latex document
  
  5008   Wed Jul 20 22:16:27 2011 Ishwita, ManuelUpdateElectronicslying seismometer cable and plugging itWe laid the cable along the cable keeper
from the BACARDI seismometer to the rack
1X6, the excess cable has been coiled under
  
  5018   Fri Jul 22 14:22:13 2011 Ishwita, ManuelUpdatePEMSTS-2 seismometer hardware testingWe have two STS-2 seismometer boxes...
the blue
box & the 
  
  5059   Fri Jul 29 12:25:54 2011 Ishwita, ManuelUpdatePEMSTS-2 seismometer boxThe 'Bacardi' STS-2 seismometer was tested
with the "purple" breakout box
and it was found out that all the three axes
  
  5175   Wed Aug 10 15:17:39 2011 Ishwita, ManuelUpdatePEMCalibration of Guralp and STS2

    
        
  
  5185   Thu Aug 11 09:39:25 2011 Ishwita, ManuelUpdatePEMCalibration of Guralp and STS2

    
        
 pw_gurs_aug11.png 
  5186   Thu Aug 11 10:56:08 2011 Ishwita, ManuelUpdatePEMMoving Seismometers

    
        
  
  5190   Thu Aug 11 13:41:36 2011 Ishwita, ManuelUpdatePEMCoherence of Guralp1 and STS2(Bacardi, Serial NR 100151)Following is the coherence plot obtained
when Guralp1 and STS2(Bacardi, Serial NR
100151) are placed very close to each other
 coher_gur1_sts1_near.pngcoherence_pic.JPG 
  5196   Thu Aug 11 16:15:59 2011 Ishwita, ManuelUpdatePEMCalibration of Guralp and STS2 
Finally, we have found the correct
calibration of Guralp and STS2 seismometers.
  
  5201   Fri Aug 12 00:18:30 2011 Ishwita, ManuelUpdatePEMCoherence of Guralp1 and STS2(Bacardi, Serial NR 100151) 
 We moved the seismometer STS2(Bacardi,
Serial NR 100151) as we told in this Elog
 coher_gur1_sts1_31m.pngcoher_gur1_sts1_38.png 
  5148   Tue Aug 9 02:27:54 2011 Ishwita , ManuelUpdatePEMPower spectra and Coherence of Guralps and STS2We did offline wiener filtering on 3rd
August (Elog
entry) using only Guralps' channels X
 Coher_gur1_gur2_BW0.01.pngCoher_gur1_sts1_BW0.01.pngCoher_sts1_gur2_BW0.01.pngPw_gurs_correct.pngPw_gur1_sts1_correct.png 
  5168   Wed Aug 10 12:28:22 2011 Ishwita , ManuelUpdatePEMAA board gainWe used a function generator, an oscilloscope
and the Data Viewer to check the gain of
the new AA board (used for the seismometers).
 pw_gur1_sts1_aug10.png 
  5172   Wed Aug 10 14:27:39 2011 Ishwita , ManuelUpdatePEMCalibration of Guralp and STS2ADC:
216counts = 4V Hence, calibration
of ADC is 214counts/V.
  
  5197   Thu Aug 11 16:21:16 2011 Ishwita , ManuelUpdatePEMPower spectra and Coherence of Guralps and STS2 
 Following is the power spectrum
plot (with
 Pw_gur1_sts1_correct.png 
  5200   Thu Aug 11 19:14:22 2011 Ishwita , ManuelUpdatePEMSeismometer STS2(Bacardi, Serial NR 100151) moved near ETMX We moved the STS2(Bacardi, Serial NR 100151)
to his new location and laid his cable from rack 
 cable_to_etmx.pngsts2_etmx.png 
  4854   Wed Jun 22 12:29:57 2011 IshwitaSummaryAdaptive FilteringWeekly summaryI started on the 16th with a very intense
lab tour & was fed with a large amount
of data (I can't guarantee that I remember
  
  4856   Wed Jun 22 17:35:35 2011 IshwitaUpdateGeneralHot air stationThis is the new hot air station for the
40m lab.........
 
 P6220212.JPGP6220213.JPG 
  4959   Mon Jul 11 10:10:31 2011 IshwitaConfiguration AA board The AA board shown in attachment 1 will
be used in the seismometer hardware setup.
A cartoon of this setup is shown in attachment
 P7080305.JPGseismometers.png 
  5020   Fri Jul 22 17:01:41 2011 Iron ManFrogsGeneralProof that Alberto lived through his Iron Man!   Alberto_IronMan_small.jpg 
  6003   Thu Nov 24 15:48:27 2011 IllustratorUpdateelogelogd gained an immunity to googlebot   elog_mario.pnggolden-monkey.jpeg 
  11530   Tue Aug 25 16:33:31 2015 Ignacio, SteveConfigurationPEMSeismometer enclosure copper foil progressSteve ordered
about two weeks ago a roll of 0.5 mm thick
copper foil to be used for the inside of
 picture1.jpgpicture2.jpgIMG_1966.JPGIMG_1969.JPG 
  11493   Tue Aug 11 11:56:36 2015 Ignacio, JessicaUpdatePEMWasps obliterated maybe...The wasp terminator came in today. He obliterated
the known wasp nest.

 IMG_1942.JPGIMG_1943.JPGIMG_1944.JPG 
  11389   Wed Jul 1 16:16:46 2015 IgnacioUpdateGeneralAccelerometers reinstalled for future huddle testToday, I installed the Wilcoxon accelerometers
in the table near the end of the mode cleaner.
I only set three of them up instead of all
 9x 
  11391   Sun Jul 5 18:14:13 2015 IgnacioUpdatePEMWilcoxon Accelerometer Huddle TestUpdated: On Thursday/Friday (sorry
for late elog) I was messing with Eric's
Wilcoxon 731A accelerometer huddle test data
 8x 
  11407   Tue Jul 14 10:23:27 2015 IgnacioUpdateGeneralOptimal detector array placement thoughtsOver the past few days, I've been thinking
about how to workout the details conerning
Rana's request about a 'map'
  
  11423   Fri Jul 17 02:46:07 2015 IgnacioUpdateGeneralNew huddle test data for Wilcoxon 731A resultsOn Thursday, new huddle test data for the
Wilcoxon 731A was aquired by Eric. 

The difference between this new
 6x 
  11424   Fri Jul 17 04:56:37 2015 IgnacioUpdateGeneralMCL Wiener filtering + FIR to IIR conversion using vectfit 

We took data for the mode cleaner
a while ago, June 30th I believe. This data
 9x 
  11425   Sat Jul 18 06:12:07 2015 IgnacioUpdateGeneralMCL Wiener filtering + FIR to IIR conversion using vectfit (Update)(updateAfter Eric gave me feedback on my
previous elog post, I went back and fixed
some of the silly stuff I stated.
 15x 
  11432   Tue Jul 21 05:17:09 2015 IgnacioUpdateGeneralMore clear accelerometer huddle tests resultsI generated the following plots from the
two sets of huddle test data we have for
the accelerometers. 
 new_data.pngnew_data.pngold_data_1.pngold_data_1.pngold_data_2.png 
  11442   Thu Jul 23 21:12:14 2015 IgnacioUpdateGeneralNewer accelerometer huddle test data + detrendingIn the last post concerning the self noise
of the accelerometers, I mentioned the differences
between the two data sets I was playing with.
 old_data_1.pngold_data_2.pngnew_data.pngsix_old_data.png 
  11446   Fri Jul 24 23:08:53 2015 IgnacioUpdatePEMMC1 accelerators moved for future huddle testI have moved the MC1 accelerators and cable
to the huddle test set up, in order to see
how a six witness huddle test with the improved
 image1.JPG 
  11449   Tue Jul 28 05:00:03 2015 IgnacioUpdateGeneralSeismometer cansI've have been talking a little   
  11450   Tue Jul 28 09:31:35 2015 IgnacioUpdateGeneralNewest accelerometer huddle testI downloaded new accelerometer huddle test
data from last night and analyzed it. This
new data set is ~55 mins and uses the same
 selfnoise_allsix_miso_newest.png 
  11457   Wed Jul 29 10:34:42 2015 IgnacioSummaryLSCCoherence of arms and seismometersJessica and I took 45 mins  (  8x 
  11460   Wed Jul 29 17:51:56 2015 IgnacioUpdatePEMAccelerators moved back to MC1 and MC2We are done taking accelerator huddle test
data. So I moved back all six accelerometers
and cables to MC1 and MC2. I also relabel
 FullSizeRender.jpgFullSizeRender_2.jpg 