  11954   Wed Jan 27 20:51:00 2016 ranaUpdatePEMETMX floor vs table noiseI didn't really appreciate this measurement
until just now. IF you can save the DTT .xml
file with all the traces in it (i.e. NOT
  
  11962   Fri Jan 29 16:55:27 2016 ranaUpdateGreen LockingInnolight laser is 10 years oldI don't think there's any evidence
that the noise eater is bad. That would change
the behavior of the relaxation oscillation
  
  12022   Sat Mar 5 10:37:48 2016 ranaUpdateIOOPSL Laser OpenedSorry, that was me; taking some photos
of the PSL and EX mirrors.

  
  12027   Tue Mar 8 18:22:20 2016 ranaUpdateGreen LockingLaser swap - some improvementWhy is the transmission of X green so low?
Perhaps you can phase lock the IR and then
scan the X frequency, using the X arm as
  
  12030   Thu Mar 10 16:32:45 2016 ranaUpdateendtable upgradeInventory checkIts not a good idea to use green mounts
with green lasers. Steve should be able to
get another copy of the EY doubler mount
  
  12032   Sat Mar 12 22:23:37 2016 ranaSummaryIOOPMC relockedFound it locked on TEM01 mode.

Sweets in the fridge for non-PhD
holders, courtesy of the highest levels of
  
  12048   Fri Mar 25 23:54:04 2016 ranaUpdatePEMGuralp SeismometersSomething seems not right. The Guralp response
should be flat in velocity from 0.05-30 Hz.
Why is there any feature at 1 Hz? Saturation
  
  12092   Wed Apr 27 09:45:56 2016 ranaUpdateSUSspare SOS towerBah, we need ruby slippers for all future
suspensions. Prism with curved backside and
smooth grooves.
  
  12093   Wed Apr 27 14:06:31 2016 ranaSummaryGeneralmeeting notes
Gautam will get
help from Johannes and finish EX table by
Monday.
Steve
  
  12098   Thu Apr 28 18:53:05 2016 ranaUpdateLSCGreen PDH demod lowpassOK - but give us a circuit diagram and
the expected before/after loop plots. Got
to make sure we keep the right impedance
  
  12102   Mon May 2 17:06:58 2016 ranaSummaryCOCG&H optics to Fullerton/HWS for anneal testingSteve sent 4 of our 1" diameter G&H
HR mirrors to Josh Smith at Fullerton for
scatter testing. Attached photo is our total
 20160427_182305.jpg 
  12103   Mon May 2 17:11:55 2016 ranaUpdateCOCRC folding mirrorsAntonio/Gautam
are now developing a more up to date Finesse
model of our recycling cavities to see what
  
  12108   Thu May 5 14:05:01 2016 ranaUpdateendtable upgradeALS status updateAll seems very fishy. Its not good to put
attenuators and filters in nilly-willy.


Once the post-PD bandpass
  
  12111   Fri May 6 19:08:52 2016 ranaUpdateLSCGreen PDH demod lowpassSeems weird to design a PD lowpass with
a corner at the modulation frequency. Recall
what our strategy is with the other photodetectors
  
  12113   Sun May 8 08:39:21 2016 ranaUpdateLSCGreen PDH demod lowpassIndeed. This is why the LSC PDs have a
2f notch in addition to the 1f resonance.
In recent versions, we also put a 2f notch
  
  12178   Tue Jun 14 16:53:16 2016 ranaUpdateSUSETMX watchWhat about ETMY? and are these really microradians
or just some made up cal?
  
  12193   Thu Jun 16 18:42:12 2016 ranaUpdateCOCContrast as a function of RoC of ETMXThat sounds weird. If the ETMY RoC   
  12197   Mon Jun 20 01:38:04 2016 ranaUpdateCOCContrast as a function of RoC of ETMXSo, it seems that changing the ETMX for
one of the spares will change the contrast
defect from ~0.1% to 0.9%. True? Seems like
  
  12210   Wed Jun 22 08:40:42 2016 ranaUpdateLSCY arm @ 30kHz UGF w/POY, AOBelow 100 Hz, I suppose this means that
the X arm is now limited by the quadrature
sum of the X and Y arm seismic noise.
  
  12214   Sun Jun 26 15:27:28 2016 ranaFrogsIOOPMC /MC lopcedFound PMC unlocked for many hours so I
relocked it. IMC relocked by itself, but
the input switch seems to be flickering to
  
  12245   Tue Jul 5 19:10:41 2016 ranaUpdateGeneralVent progressI'd suggest clamping and moving it
to the flow bench so you can inspect with
a bright light. Then remove the wire and
 jumpEvent20151105.png 
  12286   Sun Jul 10 18:20:39 2016 ranaUpdateElectronicsAntialiasing Filter UpdateComments on the schematic:


Only the instrumentation
amp should be made up of the ADA4004. Not
  
  12330   Mon Jul 25 12:22:18 2016 ranaUpdateComputer Scripts / ProgramsFinished MEDM Tab on Summary PagesLooks pretty great. However, there's
two problems:

1) Some of the MEDM screens don't
  
  12332   Mon Jul 25 13:47:19 2016 ranaUpdateGeneralETMX suspension - progressUgh.    
  12343   Wed Jul 27 16:56:47 2016 ranaMetaphysicsSUSBroken wireFor the rest of this vent, at least, we
need to start using the EQ stops
more frequently. Whenever the
  
  12350   Thu Jul 28 22:43:03 2016 ranaUpdateGeneralETMY UL magnet broke offI'd recommend replacing the wire and
grinding down the clamp to prevent cutting
the wire. Since we have almost never replaced
  
  12358   Sun Jul 31 17:28:38 2016 ranaOmnistructureGeneralupcleanI cleaned up the south Electronics bench
today.

The other two, as well as several
  
  12361   Mon Aug 1 20:09:37 2016 ranaUpdateCDSDAFI UpdateI found the DAFI screen as a button inside
of the LSC screen - I think its more logically
found from the sitemap, so I'll move
  
  12371   Thu Aug 4 10:57:58 2016 ranaUpdateComputer Scripts / ProgramsNODUS update / restarts underwayUsual Ubuntu apt-get upgrades; long delayed
but now happening.
  
  12389   Tue Aug 9 19:35:49 2016 ranaUpdateSEIboth Guralp seismometers are functioning and being acquiredAfter
some cable swapping, we now have both Guralp
seismometers running and the times series
 1goodday.png 
  12406   Fri Aug 12 21:26:28 2016 ranaUpdatePEMMic Self NoiseSeems to good to be true. Maybe you're
over fitting? Please put all the traces on
one plot and let us know how you do the parameter
  
  12419   Wed Aug 17 22:09:04 2016 ranaUpdateSUSSOS sus wire orderedNot really true that it passed. That's
just an arbitrary margin. Best to throw away
all the old wire. We have no quantitative
  
  12460   Thu Sep 1 15:28:01 2016 ranaUpdateElectronicsAcoustic Tab and Amp Suspension
add photo of installation
no
more secret personal pages! put channels
into the actual pages that we look at
make
  
  12462   Thu Sep 1 15:43:16 2016 ranaUpdateSUSOSEM adjustmentsOn the bounce roll balancing:

Recall that back in 2006, the main
issue was not with the bounce mode coupling
  
  12468   Fri Sep 2 21:16:45 2016 ranaUpdateElectronicsSatellite AmplifierIn November of 2010, Valera Frolov (LLO),
investigated
our satellite amplifiers and made some recommendations
  
  12470   Mon Sep 5 21:05:06 2016 ranaUpdateElectronicsSatellite AmplifierThe attached PDF shows the output noise
of the satellite amp. This was calculated
using 'osempd.fil' in the 40m/LISO
 osempd.pdf 
  12472   Tue Sep 6 18:21:13 2016 ranaUpdateSUSOSEM issuesI looked at the PRM free swing spectra.
The modes look like they're at the right
frequencies, so pointing more and more towards
 PRMswing.png 
  12473   Tue Sep 6 20:30:56 2016 ranaUpdateSUSITMY_UL is sickIn the morning, Steve will start opening
the north BS door so that we can enter to
inspect the PRM LR OSEM.
  
  12481   Sat Sep 10 14:26:01 2016 ranaUpdateGeneralPRM SRM alignmentFor the PRM, I aligned it until the arm
flashes were maximized and the REFL camera
showed a centered spot with dips happening
 Osamu.JPG 
  12501   Sat Sep 17 02:00:23 2016 ranaUpdateSUSAlignment statusAll is not lost. I've stuck and unstuck
optics around a half dozen times. Can you
please post the zoomed in time series (not
  
  12503   Sun Sep 18 16:18:05 2016 ranaUpdateSUSAlignment statussusaux is responsible for turning on/off
the inputs to the coil driver, but not the
actual damping loops. So rebooting susaux
  
  12506   Mon Sep 19 13:57:21 2016 ranaUpdateGeneralnever post EPS files in the ELOG. Ever.http://tex.stackexchange.com/questions/2092/which-figure-type-to-use-pdf-or-eps   
  12508   Tue Sep 20 10:45:06 2016 ranaUpdateGeneralFurther recovery progressRana suspicious. We had arms locked before
pumpdown with beams on Transmon PDs. If they're
off now, must be beams are far off on the
  
  12522   Thu Sep 29 09:49:53 2016 ranaUpdateGeneralmucking aboutWith the WFS and OL, we never have figured
out a good way to separate pit and yaw. Need
to figure out a reference for up/down and
  
  12543   Mon Oct 10 17:27:29 2016 ranaUpdateDMFsummar pages dead againBeen non-functional for 3 weeks. Anyone
else notice this? images missing since ~Sep
21.
  
  12562   Fri Oct 14 15:47:00 2016 ranaUpdateTreasurefilters + clipI say just fix the clipping. Don't
worry about the PRM OSEM filters. We can
do that next time when we put in the ITM
  
  12572   Wed Oct 19 17:02:34 2016 ranaUpdateGeneral Viewports & coating of 2016These old specs are not so bad. But we
now want to get replacements for the TRX
and TRY and PSL viewports that are R <0.1%
  
  12588   Fri Oct 28 19:13:57 2016 ranaUpdateGeneralPR gainI don't think the loss of 25 ppm is
outrageous. Its just surprisingly good. The
SIS model predicted numbers more like 1 ppm
  
  12600   Sat Nov 5 15:45:44 2016 ranaUpdateCDSc1auxex channels/pins for AcromagWe don't need to record any of the
AIOut channels, the OL channels (since we
record them fast), or the _MEAN channels
  
  12615   Mon Nov 14 19:32:51 2016 ranaSummaryCDSReplacing DIMM on OptimusI did apt-get update and then apt-get upgrade
on optimus. All systems are nominal.
  