40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 301 of 344  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  7826   Fri Dec 14 01:42:53 2012 DenUpdateSUSTT angle of incidenceI've estimated max possible angle of incidence
on TT if we allow 20mm tolerance for the
beam size and 5 mm tolerance for spot location
 DSC_4791.jpeg 
  7827   Fri Dec 14 02:52:32 2012 KojiUpdateSUSTT angle of incidenceAt least, we don't want to use Al-coated
mirrors. We should use multilayer dielectric
mirrors.
  
  7828   Fri Dec 14 03:15:49 2012 JenneUpdateSUSTT angle of incidenceBut have you looked yet at what angle we
need? The first input string mirror has a
quite small incidence angle. The other input
  
  7837   Mon Dec 17 11:20:58 2012 JenneUpdateSUSBeam dumps on vertex oplevs removedI'm not sure when this was done, but there
were beam dumps in front of the lasers for
BS/PRM oplevs as well as ITMY/SRM oplevs. 
  
  7838   Mon Dec 17 14:13:55 2012 JenneUpdateSUSPRM oplev gains restored

    

       
            
  
  7844   Mon Dec 17 21:41:30 2012 ranaSummarySUSBeCu wireJust in case we want to retrofit   
  7850   Tue Dec 18 15:32:29 2012 JenneUpdateSUSTT angle of incidence


   
        
            
  
  7855   Wed Dec 19 11:14:25 2012 SteveUpdateSUSBeCu wire in stock

    

       
            
  
  7869   Fri Dec 21 16:50:30 2012 RanaUpdateSUSTT in vac DB25 pin swapping[Koji, Rana, Nic, Steve] 
  
  7871   Wed Jan 2 06:52:50 2013 KojiUpdateSUSTT in vac DB25 pin swapping[Koji, Rana, Nic, Steve]

I recalled that we used an optical
  
  7884   Tue Jan 8 18:10:41 2013 JenneUpdateSUSPRM, SRM, BS oplevs offI don't know why (I'm just leaving the
lab right now....) but BS, PRM, SRM all have
no light on their oplev PDs. I have turned
  
  7900   Tue Jan 15 01:41:40 2013 ranaUpdateSUSTT That seems like easily enough range;
as long as we can put the TT into the middle
of their range to start with we should be
  
  7903   Wed Jan 16 08:29:45 2013 SteveUpdateSUSPRM damping restoredPRM oplev servo turned off.  OLPIT
servo gain 0.15 and OLYAW  -0.3 set
to ZERO.  PRM damping restored
  
  7937   Thu Jan 24 11:31:45 2013 SteveUpdateSUSETMX damping restoredETMX sus damping restored.  It is
still noisy
  
  7938   Thu Jan 24 11:40:55 2013 JenneUpdateSUSETMX damping restored

    

       
            
  
  8093   Sat Feb 16 17:27:26 2013 yutaUpdateSUSPRM coil balancedPRM coil gains and f2a filters are adjusted
for PRMI work.
It seems like 
 PRM_f2a.png 
  8096   Sun Feb 17 19:27:19 2013 ranaUpdateSUSPRM coil balanced I will check out the AS55 situation
tomorrow. Just put it on my desk.
MC Autolocker was disabled
  
  8152   Sun Feb 24 00:14:28 2013 ManasaUpdateSUSSUS SummaryI tried to fix the alarms for sensors on
the SUS summary screen. I checked earlier
elogs and found the setSensors.py script.
  
  8154   Sun Feb 24 17:54:34 2013 ranaUpdateSUSSUS Summary 
 I asked John Z to talk with
Jamie and then install a new NDS2 server
  
  8159   Mon Feb 25 20:04:22 2013 JamieUpdateSUSsuspension controller model modifications in prep for global damping initiative[Jamie, Brett, Jenne]
We made some small modifications
to the 
 sus_update.pngodd-mc2-stuff.png 
  8160   Mon Feb 25 20:25:33 2013 BrettUpdateSUSNew Global Damping MEDM ScreensGlobal damping screens are in progress
for the new global damping infrastructure
Jamie discussed in log #8159. The main overview
  
  8161   Mon Feb 25 20:49:07 2013 BrettUpdateSUSMinor Mod made to SUS_GLOBAL block I made a minor modification to install
some output filters in the new global damping
GLOBAL box in c1sus.mdl. These will be needed
  
  8168   Tue Feb 26 10:17:44 2013 JamieUpdateSUSremoved global/local switch from sus_single_control[jamie, brett]
Yesterday
we added some new control logic to the sus_single_control
  
  8169   Tue Feb 26 10:20:31 2013 JamieUpdateSUSMC2 suspension controller reverted to library partI made good on my threat from yesterday
to convert the MC2 suspension controller
to the library part.  Whatever changes
  
  8172   Tue Feb 26 16:13:18 2013 BrettUpdateSUSITMY and ETMY mysterious loop gain difference of 2.5While doing initial measurements for the
new global damping infrastructure I discovered
that the ETMY loop between the OSEM actuation
 Screenshot.png 
  8174   Tue Feb 26 17:56:15 2013 BrettUpdateSUSGlobal Damping UpdateThe global damping input and output matrices
were installed to run for the Y-arm. Since
we are using just one arm for now, only the
  
  8182   Wed Feb 27 11:59:43 2013 yutaUpdateSUSPRM/BS coil re-balancedI re-adjusted coil gains and f2a filters
for PRM and BS.
I'm not sure what happened to PRM
 PRM_f2a20130227.pngBS_f2a20130227.png 
  8193   Wed Feb 27 22:28:53 2013 BrettUpdateSUSGlobal Damping Update New excitation points were added
after the global damping loops for more testing
options. The updated c1sus.mdl model was
 DampNoise_to_YARM_fig_27Feb2013.png 
  8207   Fri Mar 1 16:37:45 2013 BrettUpdateSUSGlobal Damping UpdateBrett and Kamal
The global damping testing for the
week is now complete. The c1sus.mdl simulink
 GlobalDamp_Simulink.pngGlobalDampScreens.png 
  8220   Mon Mar 4 16:26:45 2013 BrettUpdateSUSGlobal Damping Noise MeasurementHere is an amplitude spectrum plot of y-arm
cavity noise with a 50 Hz cutoff damping
filter of the form zpk(0,[50;50],1). The
 YARM_Noise.png 
  8221   Mon Mar 4 16:46:31 2013 yutaUpdateSUSoplev calibration for PRM[Manasa, Sendhil, Yuta]

We calibrated oplev for PRM. Calibration
 PRM_PIT.pngPRM_YAW.png 
  8223   Mon Mar 4 18:11:10 2013 JamieUpdateSUSCleaning up suspension POS inputsI did a little bit of cleanup of the suspension
POS inputs today, both in model and MEDM
land.
 SUS_ETMX_POS.png 
  8232   Tue Mar 5 17:09:30 2013 yutaUpdateSUSoplev calibration for ITMY[Manasa, Sendhil, Yuta]

We calibrated oplev for ITMY. Calibration
 ITMY_PIT.pngITMY_YAW.png 
  8236   Tue Mar 5 23:37:11 2013 yutaUpdateSUSPRM angular motion spectraI measured PRM angular motion spectra (in
daytime today).
PRM angular motion is 
 PRMangularmotion.png 
  8362   Thu Mar 28 00:31:11 2013 JenneUpdateSUSPRMI optics' oplev servos tuned[Rana, Gabriele, Jenne, Jamie, Lisa, Rana]
We have tuned the oplev servos for
PRM, BS, ITMX, ITMY.  For each, we measured
 8x 
  8389   Tue Apr 2 15:58:40 2013 JenneUpdateSUSoplev calibration for ITMX, BS[Jenne, Gabriele]
Optical lever calibrations:
ITMX pit calibration = -9.07 cts/mrad
 opl_itmx.pngopl_bs.png 
  8390   Tue Apr 2 16:13:10 2013 ranaUpdateSUSoplev calibration for ITMX, BS    
  8391   Tue Apr 2 16:55:34 2013 JenneUpdateSUSoplev calibration online for ITMs, BS, PRM[Jenne, Gabriele]
We have put in a new EPICS input
into the SUS library part, just before the
 comparison_opl.pdf 
  8393   Tue Apr 2 18:19:30 2013 JenneUpdateSUSBS, PRM oplev servos improved 
[Gabriele, Jenne]
We have implemented 4Hz resonant
 PRM_servo_matches_BS.pdfprm_bs_optical_levers_comparison.pdf 
  8441   Thu Apr 11 03:25:29 2013 JenneHowToSUSIdea for how to properly balance SUS actuators We have calibrated the overall actuators of
each suspension independent of the optical
levers. So, we know how much we are 
  
  8480   Tue Apr 23 22:59:05 2013 ranaConfigurationSUSOptical Lever Gains normalizedDue to the recent addition   
  8481   Wed Apr 24 00:42:07 2013 JenneUpdateSUSPRMI locked, ITMX pitch OpLev ringing upKoji is working on PRMI locking, and while
he was doing that I glanced at the oplevs'
spectra for the ITMs and PRM.
 PRMI_locked_ITMXpitOpLevRingingUp.pdf 
  8482   Wed Apr 24 00:44:33 2013 KojiUpdateSUSPRMI locked, ITMX pitch OpLev ringing upI tried to reproduce the locking situation
described in this
entry tonight.
  
  8510   Tue Apr 30 10:54:35 2013 JenneUpdateSUSETMX restoredI'm not sure why or when it was tripped,
but I have restored the ETMX watchdog.
  
  8514   Tue Apr 30 22:40:57 2013 JenneUpdateSUSoplev XY-plots reflect new calibrationBack when Gabriele was here, he and I implemented
online calibration of the oplevs, into microradians. 
A consequence of this is that all of the
  
  8527   Fri May 3 09:17:41 2013 SteveUpdateSUSETMX needs some help   ETMX3.2eq.png 
  8533   Tue May 7 03:14:06 2013 JenneUpdateSUSPRM SUS_LSC violin (FM5) set to correct frequencyWhile looking over Koji's shoulder earlier,
I noticed the big peak in the PRM yaw spectrum
(and I was starting to get annoyed by the
  
  8612   Wed May 22 00:42:13 2013 KojiSummarySUSviolin QWhile looking at the decay of the violin
mode of the PRM, I made a simple measurement
of the decay rate.
  
  8617   Wed May 22 15:48:56 2013 JamieUpdateSUSTurn off zero padding in DAC outputsAfter the results of the analysis in the
#8598
thread, I have added the "no_zero_pad=1"
  
  8620   Wed May 22 18:24:19 2013 JenneUpdateSUSViolin mode survey

    

       
            
  
ELOG V3.1.3-