  2190   Fri Nov 6 07:55:59 2009 steveUpdateComputersRFMnetwork is downThe RFMnetwork is down.  MC2 sus damping
restored.
  
  2189   Fri Nov 6 00:40:29 2009 AlbertoUpdateLSCEverything put back as it wasI disconnected the setup for the arm cavity
TF measurement. I opened the scitation switch
on the ISS medm screen. I reconnected the
  
  2188   Fri Nov 6 00:24:06 2009 AlbertoUpdateLSCY Arm Cavity Transfer Function

    
        
 YarmTF02.png 
  2187   Fri Nov 6 00:23:34 2009 AlbertoConfigurationComputersElog just rebootedThe elog just crashed and I rebooted it   
  2186   Thu Nov 5 23:09:34 2009 AlbertoUpdateLSCY Arm Cavity Transfer FunctionAs for the X Arm, this the transfer function
I measured for the Y arm cavity.
 YarmTF01.png 
  2185   Thu Nov 5 22:30:09 2009 AlbertoUpdateLSCX Arm Cavity Transfer FunctionIt seems that just repeating the measurement
was enough to get a good transfer function
of the x arm cavity. Here's what I got.
 XarmTF01.png 
  2184   Thu Nov 5 19:25:11 2009 AlbertoUpdateLSCX Arm Cavity transfer Function


   
        
            
 PDA255CalibrationTF03.png 
  2183   Thu Nov 5 16:41:14 2009 josephbConfigurationComputersMegatron's personal networkIn investigating why megatron wouldn't
talk to the network, I re-discovered the
fact that it had been placed on its own private
  
  2182   Thu Nov 5 16:30:56 2009 peteUpdateComputersmoving megatron Joe and I moved megatron and its
associated IO chassis from 1Y3 to 1Y9, in
preparations for RCG tests at ETMY.
  
  2181   Thu Nov 5 16:24:59 2009 KojiUpdateCDSETMY CDS test stuffJoe, Peter, Jay, Koji, Rana
We put the new CDS stuff at Y end
1Y9 rack.
  
  2180   Thu Nov 5 16:24:40 2009 JenneUpdateGeneralDrill Press is down for the countThe on/off switch for the drill press is
broken.  Replacement parts should be
here tomorrow. 
  
  2179   Thu Nov 5 12:34:26 2009 kiwamuUpdateComputerselog rebootedI found elog got crashed. I rebooted the
elog daemon just 10minutes before.
  
  2178   Thu Nov 5 05:07:22 2009 ranaUpdateLSCX Arm Cavity transfer FunctionI would have guessed that you have to calibrate
the detectors relative to each other before
trying this. Its also going to be tricky
  
  2177   Wed Nov 4 23:17:51 2009 AlbertoUpdateLSCX Arm Cavity transfer FunctionI measured the transfer function between
MC_TRANS and TRX and I'm attaching the result.
 ArmCavityTF02.png 
  2176   Wed Nov 4 21:46:18 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2175   Wed Nov 4 18:35:19 2009 AlbertoUpdateLSCArm Cavity Finesse Measurement

    
        
  
  2174   Wed Nov 4 16:49:32 2009 AlbertoUpdateLSCArm Cavity Finesse MeasurementI'm going to work on the X arm to measure
the arm cavity finesse.
The idea is to measure the cavity
 DSC_0952.JPG 
  2173   Tue Nov 3 12:47:01 2009 KojiConfigurationCDS1Y9 Rack configuration updateFor the CDS upgrade preparation I put
and moved those stuff at the rack 1Y9:
Placed 1Y9-12 ADC to DB44/37 Adapter
  
  2172   Tue Nov 3 03:45:04 2009 rob UpdateIOOfrequency noise problem

    
        
 noise.pngspectra.pdf 
  2171   Mon Nov 2 21:09:15 2009 SanjitUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen 
I made some changes in the code (all
commented in the installed and SVN version)
  
  2170   Mon Nov 2 15:27:08 2009 JenneUpdatePEMGur2 cables have been movedThe cables labeled "Gur2" which
were connected to channels 2,3,4 of the PEM-ADCU
have been moved to the PCIX ADC which is
  
  2169   Mon Nov 2 13:34:36 2009 kiwamuConfigurationPSLremoved multiply resonant EOMI removed the multiply resonant EOM that
has been set by a SURF student from PSL table.
I will use it for checking the resonant
  
  2168   Mon Nov 2 13:00:55 2009 KojiUpdateIOOPMC aligned, MC WFS alignedThe beam to PMC aligned. The beam to MC
WFS cameras aligned.
PMC Trans increased from 2.73 to 2.75
  
  2167   Mon Nov 2 10:56:09 2009 kiwamuUpdateLSCcron job works succesfully & no timing jitterAs
I wrote on Oct.27th, the cron job works
every Sunday.
  
  2166   Sun Nov 1 17:58:44 2009 JenneUpdateGeneralUpdate on Video SwitchThe current update on the Chameleon video
switch is: no progress.
I connected the old laptop that Rob/Steve
  
  2165   Fri Oct 30 10:52:56 2009 JenneUpdatePSLHEPAsZach found the HEPA switch on the PSL table
OFF.  He turned them on.
  
  2164   Fri Oct 30 09:24:45 2009 steveHowToMOPAhow to squeeze more out of little


   
        
            
 44to34.jpg 
  2163   Fri Oct 30 04:41:37 2009 robUpdateLockingworking againI never actually figured out exactly what
was wrong in entry 2162,
but I managed to circumvent by changing the
  
  2162   Thu Oct 29 21:51:07 2009 robUpdateLockingbad

    
        
 itsback.png 
  2161   Thu Oct 29 20:21:14 2009 KojiUpdatePSLNPRO LTMP lowered 9.5degHere is the plots for the powers. MC TRANS
is still rising.
What I noticed was that C1:PSL-FSS_PCDRIVE
 PSL_MC.png 
  2160   Thu Oct 29 18:25:33 2009 SanjitUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen

    
        
  
  2159   Thu Oct 29 18:04:02 2009 JenneUpdateAdaptive FilteringMore work on saving coeffs on the OAF screen[Sanjit,Jenne]
Sanjit has been working today on
trying to get the OAF coefficients to save
  
  2158   Thu Oct 29 13:48:32 2009 KojiUpdatePSLNPRO LTMP lowered 9.5deg13:00 Found MC TRANS less than 7.
13:50 Go into the PSL table.
14:20 Work done. Now I am running
 091028_PSL.png 
  2157   Wed Oct 28 17:20:21 2009 ranaSummaryCOCETM HR reflectivity plotThis is a plot of the R and T of the existing
ETM's HR coating. I have only used 1/4 wave
layers (in addition to the standard 1/2 wave
 etm_40_1998.png 
  2156   Wed Oct 28 14:39:10 2009 steveUpdatePEMafter the tour of the 40m Illuminators and PSL lights turned off.
HEPA filter speed increased from 20 to 100%
  
  2155   Wed Oct 28 09:12:18 2009 steveUpdatePSLPMC power on the rise?The PMC power is seems to be on the rise,
( MOPA_AMPMON is dropping ?) but I do not
think it is real. We have Santa Anna wind
 pmcprising.jpg 
  2154   Wed Oct 28 05:02:28 2009 robUpdateLockingbackLockAcq is back on track, with the full
script working well.  Measurements in
progress.
  
  2153   Tue Oct 27 19:37:03 2009 kiwamuUpdateLSCcron job to diagnose LSC-timingI set a cron job on allegra.martian to
run the
diagnostic script every weekend.
  
  2152   Tue Oct 27 18:19:14 2009 robUpdateLockingbad

    
        
 MCF_issue.pngno_MCF_issue.png 
  2151   Tue Oct 27 18:01:49 2009 robUpdatePSLhmmmA 30-day trend of the PCDRIVE from the
FSS.
 pcdrive_trend.png 
  2150   Tue Oct 27 17:58:25 2009 JenneConfigurationPEMUnknown PEM channels in the PEM-ADCU?Does anyone know what the channels plugged
in to the PEM ADCU, channels 5,6,7,8 are? 
They aren't listed in the C1ADCU_PEM.ini
  
  2149   Tue Oct 27 15:55:04 2009 KojiUpdateGeneralISS injection work / HEPA is onI was working on the ISS excitation to
take TFs.
I used ISS IL excitation, stealing
  
  2148   Tue Oct 27 01:45:02 2009 robUpdateLockingMZ[quote] Tonight we also encountered a large
peak in the frequency noise around 485 Hz.
 Changing the MZ lock point (the spot in
  
  2147   Mon Oct 26 23:14:08 2009 KojiUpdatePSLlaser power is down I adjusted the steerings to the PMC and
gained 7%. Now the MC_TRANS 7.0 has been
recovered.
 PSL091026.png 
  2146   Mon Oct 26 19:12:50 2009 kiwamuUpdateLSCdiagnostic script for LSC timingThe diagnostic script I've written is available
in the 'caltech/users/kiwamu/work/20091026_OMC-LSC-diag/src'.
To run the script, you can just execute
  
  2145   Mon Oct 26 18:49:18 2009 kiwamuUpdateLSCOMC-LSC timing issueAccording to my measurements I
conclude that LSC-signal is retarded from
 exp1.pngexp2.pngOMC_LSC60sec.png 
  2144   Mon Oct 26 18:15:57 2009 robUpdateIOOMC OLGI measured the mode cleaner open loop gain. 
It's around 60kHz with 29 degs of phase margin.
  
  2143   Mon Oct 26 17:45:34 2009 JenneUpdateAdaptive FilteringNew changes to the OAF fe code[Alex, Jenne, Sanjit]
Alex came to the 40m today, and did
several awesome things in OAF-land.
  
  2142   Mon Oct 26 15:40:01 2009 steveUpdatePSLlaser power is down The laser power is down 5-6%  laserpowerdown.jpg 
  2141   Mon Oct 26 03:57:06 2009 robUpdateLockingbadLock acquisition has gone bad tonight. 
The initial stage works fine, up
through handing off control of CARM to MCL. 
  