40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 2 of 336  Not logged in ELOG logo
ID Date Author Typeup Category Subject
  1243   Thu Jan 22 08:34:10 2009 steveBureaucracySAFETYsafety training
Kakeru received 40m safety training yesterday.

He has no authorization to work alone in the high power beam path yet.
  1273   Thu Feb 5 09:12:29 2009 steveBureaucracySAFETYsafety updates & fire alarm test

The fire alarm test was completed at 13:30 yesterday.

 

I updated the 40M Emergency Calling List by replacing Rob by Yoichy. The calling order: Vass,  Aso and Taylor.

Rana and Yoichy were added to the "Registered PSL Operator List"  and posted it in the lab. (not in the document, that should be up dated)

We are getting ready for the annual safety audit. It will be held next week  at 14:00 Friday, Feb 13, 2009

Please participate in the preparation by correcting it or just  tell me.

 

Rod Luna is organizing the pick up of the following old equipment:

HP laser jet  5000n, 3 of 19" 10 base-T network ports and  4 small hubs,

2 Sun monitors, 1 Viewsonic monitor, 7 keypads and

Hitachi scopes 2 of V-355, 2 of V-422, 1 of V-202 and 1 of V-6165

 

 

  1288   Tue Feb 10 10:48:48 2009 steveBureaucracySAFETYsafety glasses scanned
All 40m safety glasses are absorbent.
 
They were scanned by 180 mW  2mm spot size  of 1064 nm beam and  their  transmissions were measured
They showed no degradation.
 
UVEX 's  LOTG-YAG/CO2 glasses (fits over personal glasses) 11 pieces,
Glendale-XC by Bacou-Dalloz,  #1166218VLT68% , aerodynamic style, 7 pieces, (4 missing )
KG5- glasses , heavier- made out of glass, 3 pieces,
Thorlab's LG10, 1 piece
Old glasses by "Laser Glass" Nd-YAG, 2 pieces
Totaling 24
 
Atm.2  showing our muilty wavelength glasses of 1064 and 530 nm
Their transmittance for both wavelength were zero.
 
Note: if you have prescripton safety glasses I would like to scan it for you !
 
 
 

 

 

  1319   Wed Feb 18 15:31:38 2009 steveBureaucracySAFETYemergency back-up lights checked
All 13 exit and  emergency back-up lights and their batteries were checked.
Two of  the batteries were replaced.
  1332   Mon Feb 23 11:07:01 2009 steveBureaucracySAFETYKiwamu receives safety training

Osamu and Kiwamu received 40m safety training on Thursday, Feb 19, 2009

Kiwamu needs Osamu's close supervision at PSL enclosure and AP table
I hope they already read, understood and signed the laser SOP
  1700   Wed Jun 24 17:08:16 2009 steveBureaucracySAFETYsurf student safety

The 40m lab specific safety training is done. The participants were

Stephanie Erickson, Clara Bennett, Chris Zimmerman, Zach Commings, Michelle Stephen surfs and Drew Cappel  postock.

They have already went through the Caltech Safety Office laser and general safety training.

They still have to read, understand and sign the the SOP for the laser & lab

  1802   Wed Jul 29 11:15:06 2009 steveBureaucracySAFETYKevin receives safety training

Kevin Vigue, our high school summer student went through the 40m specific safety traning yesterday.

  1980   Wed Sep 9 10:13:31 2009 steveBureaucracyGeneralthe use of FAX machine, scanner & toaster

 

 You said that the use of FAXST was forbidden for phds and graduate students. I had to swear on the promise of not ever buying an other FAXST

  2482   Wed Jan 6 16:48:52 2010 steveBureaucracySAFETYcopied NPRO key

We lost our key to the Lightwave 125/6-OPN-PS   The key shop just made one look a like that works.

  2647   Mon Mar 1 08:49:37 2010 steveBureaucracySAFETYsafety audit

The 40m safety audit will be at Wednesday afternoon, March 3

Please participate getting our lab to inspection grade safety level.

  2815   Tue Apr 20 10:55:10 2010 steveBureaucracySAFETYKevin Kuns received safety training

The 40m's new undergrad Kevin Kuns was introduced to 40m safety hazards. He is new and needs guidance as specially with 2W laser work.

Peter King will train him on Friday to LIGO-laser standard.

 

  3225   Wed Jul 14 20:15:04 2010 DmassBureaucracyCamerasIR Olympus

I borrowed the Olympus and forgot to leave a note - I should have it for at most a day. dmassey@ligo if you need it urgently

  3588   Mon Sep 20 10:33:21 2010 josephbBureaucracyComputersLarry stopped by - GC machine had conflicting IP

Larry stopped by today and had to disconnect the m25 machine (this is the 1st GC machine on the left as you walk into the control room) because its IP was conflicting with a machine over in Downs.  Do not use 131.215.115.125 as the IP on this machine as this is already assigned to someone else.  They couldn't figure out the root password to change it which is why it is not currently plugged into the network, and is not to be until an appropriate IP is assigned.

They've asked that whoever set the machine up to please contact them (extension 2974).

  3637   Fri Oct 1 16:46:20 2010 steveBureaucracySAFETYYuta received 40m-101-safety training

Our visiting graduate student Yuta Michimura received 40m specific basic safety training today.

  3664   Thu Oct 7 08:39:39 2010 steveBureaucracySAFETYJoonho receives safety training

Our new undergrad Joonho Lee received 40m specific basic safety training yesterday.

Yuta and Joonho are scheduled to participate in the LIGO-laser safety tutelage with Peter K on Oct 12

  3697   Tue Oct 12 15:51:18 2010 yutaBureaucracySAFETYthe 40m squad received safety training from Peter

Yuta, Joonho, and Suresh received the Basic Laser Safety Training from Peter King today.

Now, we got homework.

  3833   Mon Nov 1 10:28:41 2010 steveBureaucracySAFETYSuresh received 40m safety training

Our new postdoc Suresh Doravari received 40m specific safety training last week.

  3894   Thu Nov 11 11:08:26 2010 steveBureaucracyPEMAP table found open

Please remember to cover the optical tables !

  4563   Mon Apr 25 11:23:41 2011 AlastairBureaucracyComputerswiki?

40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it.  Is there some ongoing problem?

119427.strip.gif

  4564   Mon Apr 25 11:58:37 2011 JamieBureaucracyComputerswiki?

Quote:

40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it.  Is there some ongoing problem?

 There was an email from Dave Barker about this.  They had to reorganize the DNS at LHO.  The URL that should be used is: http://blue.ligo-wa.caltech.edu:8000/40m

  4565   Mon Apr 25 12:55:19 2011 JenneBureaucracyComputerswiki?

Quote:

Quote:

40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it.  Is there some ongoing problem?

 There was an email from Dave Barker about this.  They had to reorganize the DNS at LHO.  The URL that should be used is: http://blue.ligo-wa.caltech.edu:8000/40m

 Nope.  I know I had the right address, and it was down for me too all weekend.  It's better now though.  blue.ligo-wa.caltech.edu was up though.

  4566   Mon Apr 25 12:55:35 2011 AlastairBureaucracyComputerswiki?

Quote:

Quote:

40m wiki seems to have been down for quite a while now but I can't see any info in the elog about it.  Is there some ongoing problem?

 There was an email from Dave Barker about this.  They had to reorganize the DNS at LHO.  The URL that should be used is: http://blue.ligo-wa.caltech.edu:8000/40m

 Thanks Jamie, I've updated the links from the ATF wiki to reflect this.

  4668   Mon May 9 16:58:23 2011 JamieBureaucracyCDS!!!!REMEMBER TO COMMIT YOUR MODIFICATIONS!!!!

Whenever you modify any of the front-end code in /opt/rtds/caltech/c1/userapps, such as models, scripts or medm screens, REMEMBER TO COMMIT YOUR CHANGES, WITH A LOG MESSAGE!!!

cd /opt/rtcds/caltech/c1/userapps/trunk
svn commit path/to/modified/file

If you forget to commit things, they may be purged and you will loose your work.  ALWAYS COMMIT!

Things to note and watch out for:

  • When you commit, make sure you specify explicitly the path to the file that you are committing.  This repository is shared by all LIGO sites, including the sites (LHO and LLO) so you really want to make sure you're not committing anything that affects anything other than "c1" (ie. the 40m)
  • Only commit one file at a time, unless the changes to multiple files are tightly coupled.
  • Never commit without specifying the path to the file that you are committing.  Other people may be working on other files in the repository, and you don't want to commit their work with yours.
  • YOU MUST LEAVE A LOG MESSAGE.  Your log message should be specific to the file you have modified, and should be clear and verbose to explain exactly what you have done.
  • Use the "svn status" command to give you an overview of what is going on in the working directory.  This will tell you which files have been modified.  See "svn help status" for more information.

If you have questions ASK.  Don't force things.

  4669   Mon May 9 17:21:13 2011 JamieBureaucracyCDS!!!!REMEMBER TO COMMIT YOUR MODIFICATIONS!!!!

Also, remember to update the svn working copy before you begin doing any work, to make sure you're working on the most recent version:

cd /opt/rtcds/caltech/c1/userapps/trunk
svn update
  4897   Tue Jun 28 11:25:56 2011 AlastairBureaucracyComputersrestarted elog

The manual instructions on the 40m wiki for restarting wouldn't work.  I killed the process okay, but then I got an error saying it "couldn't bind to port 8080, please try again using -p to select port".  The automated script worked though.

  5451   Sun Sep 18 16:42:00 2011 KojiBureaucracyEnvironmentClean up your mess

Mess in the lab is increasing. Kiwamu and I had to clean up some stuffs to continue our work.
(i.e. some components were disturbing to open the lid of the tables.)

Basically the tools/equipments/component/cables/digital cameras/lens caps/IR viewers
you have used for the day should be cleaned up at the end of the day.

If one likes to leave a temporary stuff, leave a note to indicate by whom, for what, how long
it will be kept like that, and when one is going to back there with contact info like the cell phone #.

  5739   Tue Oct 25 21:23:17 2011 DmassBureaucracyelogElog Restarted

Elog went nonreponsive. SSH'ed into nodus to run restart script. Elog came back ~15 minutes later.

  6219   Tue Jan 24 13:36:05 2012 ZachBureaucracyGeneralIf I'm Peter Pan...

jamie_rufio.png

JA - MIE - RO!

  6222   Wed Jan 25 15:04:41 2012 JenneBureaucracySAFETY40m SOS supplies moved off of cleanroom flow bench

Bob, Callum and Daphen noted that our keeping a JDSU HeNe (max power <4mW) is against somebody's SOP.  So I cleared everything that relates to 40m SOS suspending to the bottom shelf of the 2nd cabinet in the cleanroom (the back set of cabinets nearest the flow benches).  The door has a nifty label.  Things that are in there include:

HeNe

HeNe mount

QPD and micrometer mount

microscope and micrometer mount

iris

Al beam block

Magnet gluing fixture

dumbbell gluing fixture

The electronics that we use (HeNe's power supply, 'scope, QPD readout) are still on the roll-y thing under the flow bench.

  6520   Wed Apr 11 16:33:16 2012 JenneBureaucracyGeneral40m Meeting Action Items

Action Items from Last Week:

(non-existant)

-----------------------------------------------------------------------

Action Items this Week and LEAD PERSON:

Assemble and ship 4 TTs from LHO - SURESH

Prepare electronics for TTs (coil drivers) - JAMIE

In-air TT testing to confirm we can control / move TTs before we vent (starting in ~2 weeks) - SURESH

Connect TTs to digital system and controls, lay cables if needed - JAMIE with SURESH

OAF comparison plot, both online and offline, comparing static, adaptive and static+adaptive - DEN

Static-only OAF noise budget (Adaptive noise budget as next step) - DEN

Black glass: big baffle pieces to clean&bake, get small pieces from Bob, put into baskets, make new basket for 1" pieces, get to clean&bake - KOJI

IPPOS beam measurement - SURESH with JENNE

AS beam measurement (if beam is bright enough) - SURESH and JENNE

Mode matching calculations, sensitivity to MC waist measurement errors, PRM position - JENNE

Summary of IFO questions, measurements to take, and game plan - JENNE

Think up diagnostic measurement to determine mode matching to PRC while chambers are open, while we tweak MMT - JAMIE, JENNE, KOJI, SURESH

  6595   Thu May 3 13:07:05 2012 KojiBureaucracyGeneralInterferometer check-up session

From 2PM, Jenne/Den/Koji. Finished at 10:30PM

  • General
    • More LCD screens! Wider screens!
      • Allegra - only can handle single head right now, but should prepare for the eventual upgrade of that videocard/whole computer and get 2 monitors.
      • Every workstation should have 2 24" monitors.  We currently have 2 good ones (one on Rossa, one on Pianosa), so we need 6.
    • Remove Control room shelf currently holding OSA 'scopes
    • Adjust both TV shelves so that they're at the same height, ~6" higher than the current left shelf.
      This gives space for stacking the 24" monitors for each computer.
    • Audio system for the signals!!!! Even a crappy one!
           /cvs/cds/ligo/centos5.5/cds/project/gds-2.14.2/Monitors/rockIFO
           /cvs/cds/gds/gds/Monitors/rockIFO
           (really /cvs/cds, not /opt)

  • IOO
    • PZT or Picomotor mounts for PSL/ALS beams
    • ALS on the both arm simultaneously / common/diff ALS scripts
  • SUS
    • PRM OPLEV servos are sometimes not stable. (fixed, JCD/DM/KA, 5/2/2012)
    • ETMX oplev - replace 1064nm lens with 632nm lens (KBC037, -100)
  • IFO
    • It seems that there is an occasional common-mode power transient in the arm transmissions.
      -> Track down the cause and fix.
    • Fix arm ASS even on CentOS
    • Drift of the green incident axis -> Assess the amount of the drift / replace the mount
    • Calibration of POP22 / AS110
    • PMC/IMC/ARM characterization (loss, finesse, reflectivity, etc)
  • CDS
    • Capture OSA signals in CDS (the 'scope TDS1001B has a USB port in the back for connecting to the computer)
    • Transmon (arms) for high and low power
    • POX11 whitening is not toggling the analog whitening???
    • CentOS machines cannot open simulink models properly (get "Bad Link"s everywhere, so you can't do anything useful).
    • Dataviewer and DTT can't connect to framebuilder from CentIOS machines
  • Electronics
    • Actuator noise level characterization (coil driver response in V/m & coil driver noise level V/rtHz)
    • Beat box
    • I/Q DFD
    • Improvement of POP22/110/AS110 RF circuits.
  • MEDM
    • OL alert in the watch dog screen (this is awesome!) should have small text saying "OL" (done, JCD, 5May2012)
    • Complete 40m overview screen - everything should be clickable with pseudo 3D icons
    • BETTER SUSPENSION SCREEN!!!
    • Script to generate a MEDM tree
    • Resurrect MEDM snapshots
       
    • The LSC screen has some "white" boxes -> investigate and fix them (done, KA, 5/2/2012)
    • Make the LSC control screen (compact) in the vertical arrangement (done, KA, 5/2/2012)
    • The signals of the watch dog screen should go red if any of the WDs are not enabled.
      =>Copy the logic of the signals in LSC screen.
      (done, KA, 5/2/2012)
    • Remove c1gfd from the cds status screen (done, KA, 5/2/2012)
    • Add "BURT" status indicators on the cds status screen (done, KA, 5/2/2012)
  • SCRIPT
    • Locking scripts with integrator triggers / disabling when unlocked
    • Daily diagnosis of the MC spot positions (there must be something already...)
    • Daily/occasional adjustment of the incident axis on the MC
    • Suspension "misalign/restore" script is too wild => make a new script (Done, JCD, 7May2012)
    • IFO_CONFIGURE scripts still do a burt restore, so step the optics.  Need to remove optic alignment from config .snap files, use reg restore script instead.
    • OPLEV/OSEM trending script before the IFO work for diagnosis.
    • Auto-locker for PMC/Arm/etc
  • Video
    • If each video screen has a caption, that would be great
    • GUI interface of "videoswitch" Mike!
    • Mouse Jiggler for Zita (called Swinput?)
  • Ubuntu
    • burttoday is not aliased in ubuntu. burttoday:      aliased to cd /opt/rtcds/caltech/c1/burt/autoburt/today/
    • ASS doesn't run on Ubuntu!
      ezcawrite: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
      ezcaswitch: error while loading shared libraries: libca.so: cannot open shared object file: No such file or directory
       
  6597   Thu May 3 13:35:56 2012 JenneBureaucracyGeneral40m Meeting Action Items

Action Items:

IFO:

         Arm cavity sweeps, mode scan - JENNE

        Align AS OSA (others?) - JENNE       

        Investigate PRMI glitches, instability (take PRM oplev spectra locked, unlocked, to see if PRM is really moving) - KOJI, JENNE, DEN

         Connect up beatbox for Xarm use - KOJI with JENNE       

 

TT:

Prepare electronics for TTs (coil drivers) - JAMIE

In-air TT testing to confirm we can control / move TTs before we vent (starting in ~2 weeks) - SURESH

Connect TTs to digital system and controls, lay cables if needed - JAMIE with SURESH

OAF:

OAF comparison plot, both online and offline, comparing static, adaptive and static+adaptive - DEN

Static-only OAF noise budget (Adaptive noise budget as next step) - DEN

Build amplifiers for new small microphones - DEN 

SLC:

Black glass: to clean&bake - KOJI

Scattered light measurement at the end stations: design / confirmation of the mechanical parts/optics/cameras - JAN

MM:

IPPOS beam measurement - SURESH with JENNE

AS beam measurement (if beam is bright enough) - SURESH and JENNE

Mode matching calculations, sensitivity to MC waist measurement errors, PRM position - JENNE

Think up diagnostic measurement to determine mode matching to PRC while chambers are open, while we tweak MMT - JAMIE, JENNE, KOJI, SURESH

Computers:

       Upgrade Rossa, Allegra to Ubuntu, make sure Dataviewer and DTT work - JAMIE

 

  6636   Wed May 9 15:50:13 2012 JenneBureaucracyGeneral40m Meeting Action Items

I'm combining the IFO check-up list (elog 6595) and last week's action items list (elog 6597).  I thought about making it a wiki page, but this way everyone has to at least scroll past the list ~1/week.

Feel free to cross things out as you complete them, but don't delete them.  Also, if there's a WHO?? and you feel inspired, just do it!

PRIORITY ITEMS:

Dither-align arm to get IR on actuation nodes, align green beam - JENNE

Arm cavity sweeps, mode scan - JENNE

ASS doesn't run on Ubuntu! or CentOS Fix it! - JENNE, JAMIE's help

Input matricies, output filters to tune SUS.  check after upgrade. - JENNE

POX11 whitening is not toggling the analog whitening??? - JAMIE, JENNE, KOJI

OAF comparison plot, both online and offline, comparing static, adaptive and static+adaptive - DEN

 

THE FULL LIST:

  • General
    • Revamp control room - more monitors, maybe move TV shelves. - JENNE
    • Audio system for the signals!!!! Even a crappy one! - LEO
  • SUS
    • ETMX oplev - replace 1064nm lens with 632nm lens (KBC037, -100) - JENNE
    • Input matricies, output filters to tune SUS.  check after upgrade. - JENNE
  • IFO
    • Fix occasional common-mode power transient in the arm transmissions. Probably an alignment thing. Would ISS help? - WHO??
    • Drift of the green incident axis -> Assess the amount of the drift / replace the mount - JENNE, KOJI
    • Calibration of POP22 / AS110 - JENNE
    • PMC/IMC/ARM characterization (loss, finesse, reflectivity, etc) - JENNE
    • Dither-align arm to get IR on actuation nodes, align green beam - JENNE
    • Arm cavity sweeps, mode scan - JENNE
    • Align AS OSA (others?) - JENNE  
    • Investigate PRMI glitches, instability - JENNE
    • PZT or Picomotor mounts for PSL/ALS beams - WHO??
    • ALS on the both arm simultaneously / common / diff ALS scripts - JENNE
  • CDS
    • Capture OSA signals in CDS (the 'scope TDS1001B has a USB port in the back for connecting to the computer) - WHO??
    • Transmon (arms) for high and low power - WHO??
    • POX11 whitening is not toggling the analog whitening??? - JAMIE, JENNE, KOJI
    • Install guardians to monitor EPICS values - WHO??
  • Electronics
    • Actuator noise level characterization (coil driver response in V/m & coil driver noise level V/rtHz) - WHO??
    • Beat box - KOJI
    • I/Q DFD - WHO??
    • Improvement of POP22/110/AS110 RF circuits. - WHO??
  • MEDM
    • Complete 40m overview screen - everything should be clickable with pseudo 3D icons - JENNE
    • Better suspension screen - copy from sites. - WHO??
    • Script to generate a MEDM tree - WHO??
    • Resurrect MEDM snapshots - WHO??
    • New ! buttons on every screen, include wiki page - WHO??
  • SCRIPT
    • Locking scripts with integrator triggers / disabling when unlocked - JENNE
    • Daily diagnosis of the MC spot positions (there must be something already...) - SURESH?
    • Daily/occasional adjustment of the incident axis on the MC - SURESH?
    • IFO_CONFIGURE scripts still do a burt restore, so step the optics.  Need to remove optic alignment from config .snap files, use reg restore script instead. - JENNE
    • OPLEV/OSEM trending script before the IFO work for diagnosis. - JENNE
    • Auto-locker for arms - JENNE
    • Auto-locker for PMC, PSL things - DEN
    • Diagnostic script for CDS - mx_stream, other stuff. - WHO??
  • Video
    • If each video screen has a caption, that would be great - WHO??
    • GUI interface of "videoswitch" - MIKEJ
    • Mouse Jiggler for Zita (called Swinput?) - JENNE
  • Ubuntu vs. CentOS
    • burttoday is not aliased in ubuntu.    burttoday:      aliased to cd /opt/rtcds/caltech/c1/burt/autoburt/today/ - JAMIE
    • Upgrade Rossa, Allegra, make sure they connect to DTT, Dataviewer, AWG. - JAMIE
    • ASS doesn't run on Ubuntu! or CentOS Fix it! - JENNE, JAMIE's help
    • CentOS machines cannot open simulink models properly (get "Bad Link"s everywhere, so you can't do anything useful) - JAMIE
  • MM
    • IPPOS beam measurement - SURESH with JENNE
    • AS beam measurement (if beam is bright enough) - SURESH and JENNE
    • Mode matching calculations, sensitivity to MC waist measurement errors, PRM position - JENNE
    • Think up diagnostic measurement to determine mode matching to PRC while chambers are open, while we tweak MMT - JAMIE, JENNE, KOJI, SURESH
    • Use sensoray to capture, measure beam mode at AS, POP - YUTA
  • Stray Light
    • Scattered light measurement at the end stations: design / confirmation of the mechanical parts/optics/cameras - JAN
  • OAF
    • OAF comparison plot, both online and offline, comparing static, adaptive and static+adaptive - DEN
    • Static-only OAF noise budget (Adaptive noise budget as next step) - DEN
    • Build amplifiers for new small microphones - DEN
    • Script for daily / weekly re-calculation of Wiener, post to elog if need changing - DEN
  • Tip Tilts
    • Prepare electronics for TTs (coil drivers) - JAMIE
    • In-air TT testing to confirm we can control / move TTs before we vent - SURESH
    • Connect TTs to digital system and controls, lay cables if needed - JAMIE with SURESH
  • RF Photodiodes
    • Opto Energy diode laser - look into buying - ERICG
    • Purchase fibers, splitters, other supplies - ERICG
    • Set everything up - ERICG

  6667   Wed May 23 13:57:11 2012 JenneBureaucracyGeneral40m Meeting Action Items

PRIORITY ITEMS:

Align Ygreen beam - JENNE, YUTA

Arm cavity sweeps, mode scan - JENNE, YUTA

ASS doesn't run on Ubuntu! or CentOS Fix it! - YUTA, JENNE, JAMIE's help

Input matricies, output filters to tune SUS.  check after upgrade. - JENNE

POX11 whitening is not toggling the analog whitening??? - JAMIE, JENNE, KOJI

Decide on plots for 40m Summary page - DEN, STEVE, JENNE, KOJI, JAMIE, YUTA, SURESH, RANA, DUNCAN from Cardiff/AEI

 Look into PMC PZT drift - PZT failing? Real MC length change? - JENNE, KOJI, YUTA

THE FULL LIST:

  • General
    • Revamp control room - more monitors, maybe move TV shelves. - JENNE
    • Audio system for the signals!!!! Even a crappy one! - LEO
  • SUS
    • Input matricies, output filters to tune SUS.  check after upgrade. - JENNE
  • IFO
    • Fix occasional common-mode power transient in the arm transmissions. Probably an alignment thing. Would ISS help? - MIKEJ?
    • Drift of the green incident axis -> Assess the amount of the drift / replace the mount - JENNE, KOJI
    • Calibration of POP22 / AS110 - JENNE
    • PMC/IMC/ARM characterization (loss, finesse, reflectivity, etc) - JENNE
    • Align green beam - JENNE, YUTA
    • Arm cavity sweeps, mode scan - JENNE, YUTA
    • Align AS OSA (others?) - JENNE  
    • Investigate PRMI glitches, instability - JENNE
    • PZT or Picomotor mounts for PSL/ALS beams - WHO??
    • ALS on the both arm simultaneously / common / diff ALS scripts - JENNE
  • CDS
    • Capture OSA signals in CDS (the 'scope TDS1001B has a USB port in the back for connecting to the computer) - WHO??
    • Transmon (arms) for high and low power - WHO??
    • POX11 whitening is not toggling the analog whitening??? - JAMIE, JENNE, KOJI
    • Install guardians to monitor EPICS values - WHO??
  • Electronics
    • Actuator noise level characterization (coil driver response in V/m & coil driver noise level V/rtHz) - WHO??
    • Beat box - KOJI
    • I/Q DFD - WHO??
    • Improvement of POP22/110/AS110 RF circuits. - WHO??
  • MEDM
    • Complete 40m overview screen - everything should be clickable with pseudo 3D icons - JENNE
    • Better suspension screen - copy from sites. - WHO??
    • Script to generate a MEDM tree - WHO??
    • Resurrect MEDM snapshots - WHO??
    • New ! buttons on every screen, include wiki page - WHO??
    • Screen for errors in signal transmission between models - DEN
  • SCRIPT
    • Locking scripts with integrator triggers / disabling when unlocked - JENNE
    • Daily diagnosis of the MC spot positions (there must be something already...) - SURESH?
    • Daily/occasional adjustment of the incident axis on the MC - SURESH?
    • IFO_CONFIGURE scripts still do a burt restore, so step the optics.  Need to remove optic alignment from config .snap files, use reg restore script instead. - JENNE
    • OPLEV/OSEM trending script before the IFO work for diagnosis. Put into 40m summary screen. - JENNE, DUNCAN from Cardiff/AEI
    • Auto-locker for arms - JENNE
    • Auto-locker for PMC, PSL things - DEN
    • Diagnostic script for CDS - mx_stream, other stuff. - WHO??
  • Video
    • If each video screen has a caption, that would be great - WHO??
    • GUI interface of "videoswitch" - MIKEJ
    • Mouse Jiggler for Zita (called Swinput?) - JENNE
  • Ubuntu vs. CentOS
    • burttoday is not aliased in ubuntu.    burttoday:      aliased to cd /opt/rtcds/caltech/c1/burt/autoburt/today/ - JAMIE
    • Upgrade Allegra, make sure connect to DTT, Dataviewer, AWG. - JAMIE
    • ASS doesn't run on Ubuntu! or CentOS Fix it! - JENNE, JAMIE's help
    • CentOS machines cannot open simulink models properly (get "Bad Link"s everywhere, so you can't do anything useful) - JAMIE
  • MM
    • IPPOS beam measurement - SURESH with JENNE
    • AS beam measurement (if beam is bright enough) - SURESH and JENNE
    • Mode matching calculations, sensitivity to MC waist measurement errors, PRM position - JENNE
    • Think up diagnostic measurement to determine mode matching to PRC while chambers are open, while we tweak MMT - JAMIE, JENNE, KOJI, SURESH
    • Use sensoray to capture, measure beam mode at AS, POP - YUTA
  • Stray Light
    • Scattered light measurement at the end stations: design / confirmation of the mechanical parts/optics/cameras - JAN
    • Align AUX laser into dark port - KOJI, YUTA
  • OAF
    • OAF comparison plot, both online and offline, comparing static, adaptive and static+adaptive - DEN
    • Static-only OAF noise budget (Adaptive noise budget as next step) - DEN
    • Script for daily / weekly re-calculation of Wiener, post to elog if need changing - DEN
  • Tip Tilts
    • Prepare electronics for TTs (coil drivers) - JAMIE
    • In-air TT testing to confirm we can control / move TTs before we vent - SURESH
    • Connect TTs to digital system and controls, lay cables if needed - JAMIE with SURESH
  • RF Photodiodes
    • Opto Energy diode laser - purchase - ERICG
    • Purchase fibers, splitters, other supplies - ERICG
    • Set everything up - ERICG

 

  6668   Wed May 23 20:41:37 2012 SureshBureaucracyGeneral40m Meeting Action Items: Tip-tilts : cabling and electronics

Quote:
..........
  • Tip Tilts
    • Prepare electronics for TTs (coil drivers) - JAMIE
    • In-air TT testing to confirm we can control / move TTs before we vent - SURESH
    • Connect TTs to digital system and controls, lay cables if needed - JAMIE with SURESH
  • .....

 

 [Koji, Suresh]

  We tried to locate the sixteen analog output channels we need to control the four tip-tilts (four coils on each).  We have only 8 available channels on the C1SUS machine. 

  So we will have to plug-in a new DAC output card on one of the machines and it would be logical to do that on the C1IOO machine as the active tip-tilts are conceptually part of the IOO sub-system.   We have to procure this card if we do not already have it.  We have to make an interface between this card output and a front panel on the 1X2 rack.  We may have to move some of the sub-racks on the 1X2 rack to accommodate this front panel.

  We checked out the availability of cards (De-whitening, Anti-imaging, SOS coil drivers)  yesterday.  In summary: we have all the cards we need (and some spares too).  As the De-whitening and Anti-imaging cards each have 8 channels, we need only two of each to address the sixteen channels.  And we need four of the SOS coil drivers, one for each tip-tilt.  There are 9 slots available on the C1IOO satellite expansion chassis (1X1 rack), where these eight cards could be accommodated.

  There are two 25 pin feed-thoughs, where the PZT drive signals currently enter the BS chamber.  We will have to route the SOS coil driver outputs to these two feed-throughs. 

   Inside the BS chamber, there are cables which carry the PZT signals from the chamber wall to the the table top, where they are anchored to a post (L- bracket).  We need a 25-pin-to-25-pin cable (~2m length) to go from the post to the tip-tilt (one for each tip-tilt).  And then, of course, we need quadrapus cables (requested from Rich) which fit inside each tip-tilt to go to the BOSEMs.

   I am summarising it all here to give an overview of the work involved.

 

 

  6720   Wed May 30 22:04:13 2012 JenneBureaucracyGeneral40m Action Items

.....including:

fix Q of Vio2 filter in SUS. - JENNE

Switch power source for beatnote PD's amplifiers from temporary power supplies under PSL table to permanent taking the power from a rack.

  6843   Thu Jun 21 02:57:16 2012 JenneBureaucracyGeneral40m Action Items

PRIORITY ITEMS:

ASS doesn't run on Ubuntu!
Put beatbox back, simultaneous arm ALS
Input matricies, output filters to tune SUS.  check after upgrade.
POX11 whitening is not toggling the analog whitening???
Look into PMC PZT drift - PZT failing? Real MC length change?
Vent planning / organization

THE FULL LIST:

General

     Audio system for the signals!!!! Even a crappy one!

SUS

     Input matricies, output filters to tune SUS.  Check after upgrade.

IFO

     Fix occasional common-mode power transient in the arm transmissions. Probably an alignment thing. Would ISS help?

     Drift of the green incident axis -> Assess the amount of the drift / replace the mount

     Calibration of POP22 / AS110

     PMC/IMC/ARM characterization (loss, finesse, reflectivity, etc)

     Arm cavity sweeps, mode scan

     Align AS OSA (others?)

     Investigate PRMI glitches, instability

     PZT or Picomotor mounts for PSL/ALS beams

     ALS on the both arm simultaneously / common / diff ALS scripts

     Measure green locking (Aux laser to arm) transfer functions, residual spectra

     Measure oplev spectra while locking Xgreen - see if the optics are particularly noisy

     Measure Xarm residual motion using POX while ALS is engaged.

     Fix Vio2 filter modules on SUS 

     Switch power supply for amplifiers of beatnote signal to rack power

     Add temp sensors for end lasers to CDS slow channels

     Put windows / pickoffs on PSL table for (a) green trans camera, (b) GTRY, (c) GTRX

CDS

     Capture OSA signals in CDS (the 'scope TDS1001B has a USB port in the back for connecting to the computer)

     Transmon (arms) for high and low power

     POX11 whitening is not toggling the analog whitening???

     Install guardians to monitor EPICS values

Electronics

     Actuator noise level characterization (coil driver response in V/m & coil driver noise level V/rtHz)

     Improvement of POP22/110/AS110 RF circuits?

MEDM

     Complete 40m overview screen - everything should be clickable with pseudo 3D icons

     Script to generate a MEDM tree

     Resurrect MEDM snapshots

     New ! buttons on every screen, include wiki page

     Add all screens to svn

SCRIPT

     Daily diagnosis of the MC spot positions (there must be something already...)

     Daily/occasional adjustment of the incident axis on the MC

     Panic button on Watchdog screen isn't working on Ubuntu

     OPLEV/OSEM trending script before the IFO work for diagnosis. Put into 40m summary screen.

     Auto-locker for arms

     Auto-locker for PSL things

     Diagnostic script for CDS - mx_stream, other stuff.

     Make sure scripts are all svn-ed

Video

     If each video screen has a caption, that would be great

     GUI interface of "videoswitch"

Ubuntu vs. CentOS

     Upgrade Ottavia to Ubuntu, make sure connect to DTT, Dataviewer, AWG.

MM

     IPPOS beam measurement

     AS beam measurement (if beam is bright enough)

     Mode matching calculations, sensitivity to MC waist measurement errors, PRM position

     Think up diagnostic measurement to determine mode matching to PRC while chambers are open, while we tweak MMT

     Use sensoray to capture, measure beam mode at AS, POP

Stray Light

     Scattered light measurement at the end stations: design / confirmation of the mechanical parts/optics/cameras

     Align AUX laser into dark port

     Assemble in-vac beam dumps - how many do we need?

OAF

     OAF comparison plot, both online and offline, comparing static, adaptive and static+adaptive

     Static-only OAF noise budget (Adaptive noise budget as next step)

     Script for daily / weekly re-calculation of Wiener, post to elog if need changing

Tip Tilts

     Prepare electronics for TTs (coil drivers)

      In-air TT testing to confirm we can control / move TTs before we vent

     Connect TTs to digital system and controls, lay cables if needed

     Determine whether we need to add a new flange to OMC chamber

RF Photodiodes

     Opto Energy diode laser - purchase

     Set everything up

     Demod board for AS110 - so we can also have POP110?

  6889   Thu Jun 28 20:59:28 2012 yutaBureaucracyLockingvent for PRC check, TOMORROW!

Koji, Jamie and I talked together and I decided to VENT TOMORROW MORNING. Main purpose of this vent is to see if PRM is flipped or not.

Vent schedule:
June 28 (Thu)
  Prepare for the vent tonight

June 29 (Fri)
  Start vent in the morning
  Look into PRC in the evening. If PRM was flipped, we will correct them. We'll use REFL to align the PRM. If PRM was not flipped, look into PR2,PR3 and other related optics.

June 30 (Sat)
July 1 (Sun)
  Thinking time. I can work if needed.

July 2 (Mon)
  If we need something else to do, do it.
  If not, start pumping.
  July 4th is the Independence Day. So, I need IFO working before July 4th.

Check List:
 We will just open the BS chamber.
  - PRM flipping
  - PR2, PR3 flipping
  - PRC suspensions
  - Cipping check in PRC

  6890   Thu Jun 28 22:08:57 2012 JenneBureaucracyLockingvent for PRC check, TOMORROW!

Quote:

Check List:
 We will just open the BS chamber.
  - PRM flipping
  - PR2, PR3 flipping
  - PRC suspensions
  - Cipping check in PRC

 What do you mean by PR2, PR3 flipping?  They are (supposed to be) flat mirrors, so obviously they should be installed correctly, but they won't change the mode matching in a huge way if they're backwards, right?

For the PRM, I recommend checking (a) the arrow inscribed on the thinner side of the optic and (b) that the arrow *actually* points to the HR side.  I'm pretty sure I installed all the optics with the arrow pointing away from the OSEMs, but I never did a thorough check that the arrow always actually pointed to the HR coated side.  I don't remember any optics where I said "hmmm, that's funny, the arrow is pointing backwards", but nor did I write down that I had checked.

Also, hopefully the PRM is correct.  If however it's not, that means that all of the magnets are glued onto the HR side, and we'll have to redo all of the magnet gluing.  The guiderods should be fine, but all 6 magnets would need redoing.  If we were very, very careful and didn't break any of the magnets off of the dumbbells, it's a 24 hour turnaround due to drying time.  Since inevitably we break magnets away from dumbbells, conservatively we should think about a 48 hour turnaround. 

  6891   Fri Jun 29 01:49:36 2012 yutaBureaucracyLockingvent for PRC check, TOMORROW!

Quote:

 What do you mean by PR2, PR3 flipping?  They are (supposed to be) flat mirrors, so obviously they should be installed correctly, but they won't change the mode matching in a huge way if they're backwards, right?

We see some ghost beam spots at POP. This may come from the back of PR2 and PR3. Also, they may change mode matching because of thermal lensing, mirror deformation, and other unexpected reasons. I thought we should check every mirrors in PRC, if PRM is not flipped.

We are going to check PRM just because we spent so much time for the PRC problem, and still don't have the solution or evidence.
PRM flipping is kind of the only idea for the root of all evil -- terrible beam shape, low PR gain, unstable PRMI lock.
So, I want to check with my eye during the stay.

I don't think we have to redo magnet gluing. It's okay to leave them on HR side.

  6913   Wed Jul 4 20:13:46 2012 yutaBureaucracyLockingPRC commissioning plan

Issues in PRC:
  1. Power recycling gain is too low (~ 15 instead of 40, according to Kiwamu).
  2. Mode matching to both arms are ~90%(see #6859), but PRC has terrible mode.
       Clipping/flipping in PRC?
  3. From cameras, beam spot moves so much when PRMI is locked.
       Alignment? Mirrors(especially PR2/3) moves too much?
  4. Error signals are glitchy when PRMI is locked.
       Servo design? Mirrors moves too much?

What we have learned from the vent:

  1. PRM, PR2, PR3 was not flipped.
  2. Their suspensions looked OK, too.
  3. We noticed clipping at BS and Faraday. They must be avoided when tip-tilts are installed on next vent.

  4. Took useful photos for next vent. Positions of green optics on optical layout CAD must be updated.
  5. It is not so difficult to recover the IFO state after cycling the vacuum if we use attenuator setup using PBS (see elog #6892).  But, of course, we need plans before cycling.

Commissioning Plan:
  - measure PRMI power recycling gain from POP
  - FPMI using ALS
  - measure PRFPMI power recycling gain from TRY/X
  - correlation between beam spot motion at POP camera and glitch
  - correlation between PR2/PR3 motion and glitch (how can we measure PR2/3 motion? set up oplevs?)
  - mode scan for PRC, using AS AUX laser
  - beam profile measurement at REFL,POP
  - refine servo design of MICH and PRCL

  6974   Fri Jul 13 15:49:38 2012 yutaBureaucracyGeneral40m Priority Action Items

These are all priority action items need to be done before I come back (in mid-September).
BE PREPARED FOR THE FULL LOCK!

NEXT VENT:
        - Prepare and install tip-tilts -JAMIE
        - Adjust IP-ANG -JAMIE, JENNE, KOJI
        - Make sure there's no clipping. Start from MC centering -JAMIE, JENNE, KOJI

ASS/A2L:
        - Make ASS and A2L work -JENNE, JAMIE
        - Better MC spot position measurement script(see the last sentence in elog #6892) -JENNE
        - Daily beam spot measurements for IFO, just like MC -JENNE
        - ASS for green using PZT steering mirrors on end table -JENNE
        - Modeling of phase tracking ALS -JAMIE

ALS:
        - PZT mounts for PSL and ALS beams -JENNE, KOJI
        - Add temperature sensors for end lasers to CDS slow channels -JENNE
        - Put green trans camera, GTRY PD, and GTRX PD on PSL table -JENNE
        - Better beat box; include comparators, frequency dividers, and whitening filters -JAMIE, KOJI
        - Adjust servo gain/filters of end green PDH lock (reduce frequency noise) -JENNE
        - Add on/off switch, gain adjuster, etc to CDS for end green PDH lock -JENNE, JAMIE

PRC:
        - Find why and reduce 3 Hz motion -JENNE
        - Simulation of PRMI with clipping -YUTA
        - Alignment tolerance of PRMI -YUTA

  8099   Mon Feb 18 18:28:01 2013 yutaBureaucracyAlignmentwe are going to pump down

We will start preparing for pumping down. Main goal for this is to demonstrate PRFPMI using ALS.
Here are to-dos before we pump down.

Feb 18 eveing
- check input beam and Y arm alignment again
- IPPOS/IPANG alignment
- check all oplevs

Feb 19 morning
- open ETMX chamber heavy door
- align BS to X end
- adjust OSEM values (added by YM)
- center beam on all AS optics
- make sure AS/REFL is clear
- take picture of flipped PR2 (added by YM)
- make sure green is not clipped by new PRM oplev mirrors  (added by YM)
- center all oplevs

Feb 19 afternoon - Feb 20 morning
- close PSL shutter
- close all heavy doors and put the access connector back
- start pumping down

Feb 20 evening
- start aligning IFO

  8103   Tue Feb 19 02:23:40 2013 yutaBureaucracyGeneralaction items for PRFPMI

These are things need to be done for demonstrating PRFPMI using ALS.
All of these should be done before March 8!

CDS:
    - Fix c1iscex -JAMIE (done Feb 19: elog #8109)
    - Is ASS and A2L working? -JENNE
    - Are all whitening filters for PDs toggling correctly? -JENNE, JAMIE

PRMI locking:
    - Adjust I/Q rotation angles for error signals -JENNE, YUTA
    - Adjust filters -JENNE, YUTA
    - Coil balancing for BS (and ITMs/ETMs) -YUTA

PRC characterization in PRMI:

    - Measure PR2 loss from flipping -MANASA
    - Measure mode matching ratio -JENNE, YUTA
    - Measure finesse, PR gain -JENNE, YUTA
    - Calibrate PRM and/or ITM oplevs -MANASA, YUTA
    - Measure g-factor by tilting PRM or ITMs -JAMIE, YUTA
    - Calculate expected mode matching ratio and g-factor -JAMIE
    - Calculate expected finesse, PR gain -JENNE
    - Align aux laser into AS port? -ANNALISA?

ALS:
    - What's the end green situation? Optical layout changed? Laser temperature in CDS? -MANASA
    - What's the PSL green situation? Green trans cameras/PD? -JENNE, MANASA
    - Make ALS handing off to DARM/CARM LSC script -JENNE, YUTA
    - Demonstrate FPMI using ALS -JENNE, YUTA
    - Phase tracker characterization -YUTA, KOJI

PRFPMI:
    - Measure mode matching between PRC and arms -JENNE, YUTA
    - Measure PR gain -JENNE, YUTA
    - Calculate expected finesse, PR gain -JENNE

Others:
    - Update optical layout CAD after PR2 flipping -JAMIE, MANASA
    - AS55 situation? -YUTA
    - Look into PMC drift -JENNE, MANASA
    - Measure RFAM contribution to error signals -YUTA

 


Please fix, add or update if you notice anything.

  8163   Mon Feb 25 22:30:40 2013 JenneBureaucracyGeneralaction items for PRFPMI

 

 CDS:
    - Check out ASS and A2L working -JENNE
    - Are all whitening filters for PDs toggling correctly? -JENNE, JAMIE

PRMI locking:
    - Adjust I/Q rotation angles for error signals -JENNE, YUTA
    - Adjust filters -JENNE, YUTA
    - Coil balancing for BS (and ITMs/ETMs) -YUTA

PRC characterization in PRMI:

    - Measure PR2 loss from flipping -MANASA
    - Measure mode matching ratio -JENNE, YUTA
    - Measure finesse, PR gain -JENNE, YUTA
    - Calibrate PRM and/or ITM oplevs -MANASA, YUTA
    - Measure g-factor by tilting PRM or ITMs -JAMIE, YUTA
    - Calculate expected mode matching ratio and g-factor -JAMIE
    - Calculate expected finesse, PR gain -JENNE
    - Mode match and align aux laser into AS port -EVAN

ALS:
    - What's the end green situation? Optical layout changed? Laser temperature in CDS? -MANASA
    - What's the PSL green situation? Green trans cameras/PD? Design better layout -ANNALISA
    - Make ALS handing off to DARM/CARM LSC script -JENNE, YUTA
    - Demonstrate FPMI using ALS -JENNE, YUTA
    - Phase tracker characterization -YUTA, KOJI

PRFPMI:
    - Measure mode matching between PRC and arms -JENNE, YUTA
    - Measure PR gain -JENNE, YUTA
    - Calculate expected finesse, PR gain -JENNE

Others:
    - Update optical layout CAD after PR2 flipping -MANASA
    - IMC REFL demod phase rotation -EVAN, ANNALISA
    - Look into PMC drift -JENNE, MANASA
    - Measure RFAM contribution to error signals -YUTA

  8222   Mon Mar 4 17:32:26 2013 yutaBureaucracyGeneralflowchart for PRMI g-factor measurement

I made a very useful flowchart for the week. Our goal for the week is to measure g-factor of PRC in PRMI.

PRMIgfactorPlan.png

  8261   Fri Mar 8 16:05:56 2013 yutaBureaucracyGeneralaction items for PRMI / ALS-FPMI

We should focus our work both on PRMI and ALS-FPMI (elog #8250).

CDS:

    - Check out ASS and A2L working -JENNE (ALS done, ASS on going elog #8229)
    - Are all whitening filters for PDs toggling correctly? -JENNE, JAMIE (POX11 was OK, elog #8246)

PRMI locking:
    - Adjust I/Q rotation angles for error signals -JENNE, YUTA (coarsely done elog #8212)
    - Adjust filters -JENNE, YUTA (coarsely done elog #8212)
    - Coil balancing for BS (and ITMs/ETMs) -YUTA (done elog #8182)
    - Calculate sensing matrix for PRMI and convert them into physical units -JENNE, JAMIE
    - Measure sensing matrix for PRMI -JENNE, MANASA
    - Measure 55 MHz modulation depth -KOJI

PRC characterization in PRMI:

    - Measure PR2 loss from flipping -MANASA (on going elog #8063)
    - Measure mode matching ratio -JENNE, YUTA
    - Measure finesse, PR gain -JENNE, YUTA (done elog #8212)
    - Calibrate PRM and/or ITM oplevs -MANASA, YUTA (done elog #8221)
    - Measure g-factor by tilting PRM or ITMs -JAMIE, YUTA (coarsely done elog #8235, use other methods to check)
    - Simulate intra-cavity power dependance on PRM tilt -JAMIE (see elog #8235)
    - Calculate expected finesse, PR gain -JENNE
    - Mode match and align aux laser from POY -ANNALISA (on going elog #8257)

ALS:
    - Prepare for installation of new end tables on next vent -MANASA
    - Install green DC PDs and cameras on PSL table -JENNE, MANASA
    - Make ALS handing off to DARM/CARM LSC script -JENNE, YUTA
    - Demonstrate FPMI using ALS -JENNE, YUTA
    - Phase tracker characterization -YUTA, KOJI (bad whitening elog #8214)
    - better beatbox with whitening filters -JAMIE, KOJI

Others:
    - Update optical layout CAD after PR2 flipping -MANASA
    - IMC REFL demod phase rotation -EVAN, ANNALISA (done elog #8185)
    - Look into PMC drift -JENNE, MANASA
    - Measure RFAM contribution to error signals -YUTA
    - Look into TT2 drift -JENNE, MANASA

  8302   Fri Mar 15 16:46:52 2013 JenneBureaucracyAuxiliary lockingYend table upgrade - fast track?

In light of the Yend auxiliary laser's ill health, I think we should reconsider the possibility of changing out the Yend laser table next week.

My thinking here is that if whatever the new mode matching solution is for a replacement laser (Tara has borrowed our spare NPRO that used to sit on top of the fridge, or we could take Annalisa's) requires a rework of the table layout, we might as well put the new layout onto the new table.  So, we need to figure out what laser we will put in as the new Ygreen, and what it's waist looks like.  If it just requires a small movement of existing lenses or new lenses in similar positions to the current ones, we can keep living with our current table.  But, if the mode matching solution requires enough changes to distances / lens placement / whatever, we should think seriously about putting in the new table next week.

Here's what I would like to see happen on / before Monday:

Annalisa - Mode matching solution for new laser.  If we get the laser back from Tara, this will involve first measuring the waist, otherwise we already know the waist of the ABSL laser that Annalisa is currently using.

Annalisa and Steve - Find optics for new mode matching in the lab, or order them by Monday afternoon.

Manasa - List of every screw, washer, optic, mount, etc. that will go on the new Y end table, with a notation as to whether or not we have it in-hand, and if not, what needs to happen before we do.  Also, for things that we don't have, I'd like to see a summary of temporary solutions (e.g. keep using current mount for doubling crystal while new one is being machined).

Manasa / Annalisa / Koji - will the new mode matching solution fit within the existing layout, or do we need to redo the table layout?

  8304   Mon Mar 18 12:23:25 2013 JenneBureaucracyAuxiliary lockingYend table upgrade - go fetch NPRO from ATF

Zach has just replied, and said that we should feel free to take the laser from his iodine setup in the West Bridge subbasement, in the ATF lab. 

Annalisa, please ask Koji or Tara to show you where it is, and help you bring it to the 40m.  You should install it (temporarily) on the PSL table, measure the waist, and find the beat in IR.  Elog 3755 and elog 3759 have some of the details on how it has been done in the past.

  8305   Mon Mar 18 12:35:29 2013 AnnalisaBureaucracyAuxiliary lockingYend table upgrade - go fetch NPRO from ATF

Quote:

Zach has just replied, and said that we should feel free to take the laser from his iodine setup in the West Bridge subbasement, in the ATF lab. 

Annalisa, please ask Koji or Tara to show you where it is, and help you bring it to the 40m.  You should install it (temporarily) on the PSL table, measure the waist, and find the beat in IR.  Elog 3755 and elog 3759 have some of the details on how it has been done in the past.

 Ok, I'm going to contact Koji.

ELOG V3.1.3-