40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 2 of 337  Not logged in ELOG logo
ID Date Author Typedown Category Subject Text Attachments
  207   Thu Dec 20 19:10:03 2007 waldmanUpdateOMCStressful reattachment of heaterPhotos may follow eventually,  but for now
here's the rundown.  I scraped the heater
clean of the thermal epoxy using a clean
  
  208   Thu Dec 20 21:57:34 2007 AndreyUpdateComputer Scripts / ProgramsMeasurements in XARM today
Today at 2PM I started a program, it should
change the suspension gains in the interval
 Accelerom_ETMX.pngAccelerom_ITMX.png 
  210   Fri Dec 21 20:32:25 2007 tobinUpdatePhotosGigE cameraI couldn't resist any longer: I plugged in
the Prosilica GC 750 GigE camera and took
it for a spin.  This is the little CMOS camera
 robs_desk.png 
  213   Wed Dec 26 15:00:06 2007 ranaUpdateSUSETMY trippingSteve mentioned to me that ETMY is still tripping
more than ETMX. The attached DV plot
shows the trend of the watchdog sensors;
 etm.png 
  214   Wed Dec 26 15:12:48 2007 ranaUpdateSUSETMY trippingIt turned out that the ETMY POS damping gain
was set to 1.0 while the ETMX had 3.8.
  
  215   Thu Dec 27 12:12:02 2007 pkpUpdate Update on GigE CameraSo I finally got the linux software to compile
on mafalda. I got the software to dump all
the information regarding the camera onto
  
  216   Thu Dec 27 13:08:04 2007 ranaUpdateSUSETMY trippingHere's a trend from the last 2 days of ETMX
and ETMY. You can see that the damping gain
increase
 Untitled.png 
  217   Thu Dec 27 18:18:56 2007 ranaUpdateComputersUpdate on GigE Camera[quote]So I finally got the linux software
to compile on mafalda. I got the software
to dump all the information regarding the
  
  218   Sun Dec 30 02:36:35 2007 pkpUpdateGeneralAnother updateSo I followed suggestions 1 and 3 so far and
have started writing up what all needs to
be done in order to compile and use the camera.
  
  220   Thu Jan 3 08:53:55 2008 steveUpdateSUSetmy vs etmxRana have corrected sus gain damping setting
of ETMY 8 days ago
 sus.jpg 
  221   Thu Jan 3 09:12:59 2008 steveUpdatePSLMZ servoHere is MZ trend for one year and 40 days.
Now days it runs out of range on the low
side.
 mz1y.jpgmz40d.jpg 
  222   Thu Jan 3 09:55:11 2008 steveUpdateSUSetmy sus damping restoredETMY watch dog was lost at midnight  etmy12h.jpg 
  225   Fri Jan 4 08:42:03 2008 steveUpdateSUSetmy trips againETMY sus damping tripped at 6am this morning
It was reset. We should put an accelerometer
to the south end to see
 etmy20m.jpgetmy120s.jpgetmysenV.jpg 
  226   Mon Jan 7 09:01:39 2008 steveUpdateSUSBS sus damping restoredThe BS sus damping was lost at 8am Sunday
morning.
 bssdl.jpg 
  227   Tue Jan 8 15:20:17 2008 PkpUpdateCamerasGigE update[Tobin , Pinkesh]

Finally we got the camera doing something
  
  228   Wed Jan 9 10:47:15 2008 frickeUpdateComputersethernet wiring in office/control roomThe electrical people have been here for three
days, installing ethernet cables and drops
in the 40m office area, in the old conduits
  
  230   Wed Jan 9 20:36:42 2008 GoUpdateTreasureMoney in labGo's Desk.  DSC_0370.JPG 
  232   Thu Jan 10 10:38:02 2008 steveUpdateSUSetmy damping restoredThe IST building onstruction has really started
yesterday and continuing today with big heavy
ground breaking
 etmysus.jpgsustrend16d.jpg 
  233   Thu Jan 10 12:08:23 2008 steveUpdateSUSwhy did the BS move?   bshopped.jpg 
  234   Thu Jan 10 13:45:52 2008 PkpUpdateCamerasGLIBC ErrorSo, I have tried to compile the camera files
which are in /cvs/cds/caltech/target/Prosilica/examples
for the past 2 days now and have been unable
  
  235   Thu Jan 10 15:04:04 2008 steveUpdateSUSilluminator light effect on BS positionThe bs chamber illuminator light was turned
on this morning and left on.
Earlier on Rana noticed that the bs moved.
 bssusilum.jpg 
  236   Fri Jan 11 17:01:51 2008 pkpUpdateCamerasGigE again So, here I detail all the efforts on the GigE
so far 
  
  237   Mon Jan 14 14:41:09 2008 steveUpdateSUSetmy sus damping restored & mz relockedTree days trend of MZ HV drift is typical
these days.
So as the etmy sus inability to hold damping
 etmysus&mzhvtrend.jpg 
  239   Tue Jan 15 13:15:27 2008 tobinUpdateEnvironmentlots of noiseThey're throwing concrete around at the construction
site.
  
  240   Wed Jan 16 14:06:24 2008 robUpdateLSCmonday's lockingrob, tobin, johnnie

We did some locking work monday night, with
  
  241   Wed Jan 16 14:09:45 2008 robUpdateLSCtuesday's locking
I got a little further with the locking (PRFPMI)
last night, after discovering that the cable
  
  242   Wed Jan 16 18:24:41 2008 ranaUpdateSUSETMY WatchdogBecause [COLOR=purple][B]Steve keeps complaining
about ETMY[/B][/COLOR], I looked at some
minute trend to see if there was something
 A.pdf 
  244   Thu Jan 17 14:13:20 2008 robUpdateLSCWednesday's lockingIncremental progress on locking yet again.
 This time the handoff of DARM to the OMC
worked, and progress halted at handing off
  
  245   Thu Jan 17 15:11:13 2008 josephbUpdateCamerasWorking on Malfalda1) I can statically compile the ListCamera
code (which basically just goes out and finds
what cameras are connected to the network)
  
  246   Thu Jan 17 18:22:14 2008 AlbertoUpdateElectronicsRF Monitor Band-pass FilterAfter we finalized the schematic for the RF
monitor board based on buffered LC resonators,
on Richard Abbott's suggestion to avoid the
 RF166Mhz.pngChebyshevb.pngChebyshev2b.png 
  247   Thu Jan 17 20:50:55 2008 tobinUpdateGeneralfiber couplingSam, John, and I matched the beam from an
NPRO into a fiber on the SP table today.
 In doing so we used our GigE camera for
  
  248   Fri Jan 18 11:53:50 2008 AlbertoUpdateElectronicsRF Monitor Band-pass FilterThe response is asymmetric and on the left
side of the peak, we have at least 33dB within
33Mhz, which is enough for all the frequencies.
 Chebyshevb.png 
  249   Fri Jan 18 15:31:47 2008 robUpdateLSCThursday's locking
[I]rob, johnnie, andrey[/I]
 DARMnoise080118.png 
  251   Mon Jan 21 23:30:03 2008 AndreyUpdateComputer Scripts / ProgramsMatlab Program for Q-factor measurements (XARM -> ITMX and ETMX)
Finally I overcame difficulties with adapting
Sonia's Matlab programs for XARM (Sonia's
 Example-ITMX_POS_40.png 
  252   Tue Jan 22 02:33:45 2008 robUpdateLSCDRMI work
0) The ETMY oplev needs work/centering
  
  253   Tue Jan 22 13:11:03 2008 tobinUpdateASCETMY oplev recenteredThe light wasn't even on the diode.   
  254   Wed Jan 23 09:27:55 2008 steveUpdate etmy sus damping restoredSeismis event trips etmy  etmysus.jpg 
  255   Wed Jan 23 11:41:06 2008 steveUpdatePEMsulfur smell in 40mLed - acid car batteries were overcharged
in the machine shop next door
and sulfuric acid smell is coming over to
  
  258   Thu Jan 24 11:52:56 2008 steveUpdatePEMthe mud is cleaned up & MOPA shutter is openedSafety glasses are required again!

I have just opened the mopa shutter.
  
  264   Fri Jan 25 09:22:21 2008 steveUpdatePEMburned toast award goes toDYM for  collaborating with the enemy. 

In order to minimize the number of ants visiting
  
  268   Fri Jan 25 15:53:59 2008 AlbertoUpdateElectronics40 dB from the 3rd order ChebyschevI managed to tune the 7 knobs in the 3rd order
Chebyshev bandpass filter obtaining the tranfer
function attached to this entry. We have
 166MhzElog.png 
  270   Fri Jan 25 21:36:40 2008 ranaUpdateCDSmDV / channel issues[COLOR=orange]Fri Jan 25 21:30:00 2008[/COLOR]

  
  273   Sat Jan 26 02:34:34 2008 AndreyUpdateComputer Scripts / ProgramsOvernight Measuremts in XARM
I am running the program for measuring RMS
of peaks in XARM tonight. I just started
  
  276   Sat Jan 26 22:00:03 2008 JohnUpdateGeneralLSC-TRY_OUT and ETMY-QPDIn the path from the ETM to the trans PD and
QPD at the Y end I have replaced a BS1-1064-10-2037-45P
with a polariser. The power falling on these
  
  278   Sun Jan 27 21:44:48 2008 ranaUpdateCDSSeismic BLRMS on MatlabI wrote a matlab script to produce band limited
RMS trends from our accelerometers. It mimics
the code written
 seisBLRMS.m 
  282   Mon Jan 28 18:56:47 2008 ranaUpdateDMFseisBLRMS 1.0[B]I made all of the updates I aludded to
before:[/B]
  
  284   Tue Jan 29 14:56:39 2008 robUpdateDMFseisBLRMS 1.0
The [COLOR=red]seisBLRMS[/COLOR] 1.0 program
crashed at ~7:20 pm last night, so we didn't
  
  286   Wed Jan 30 13:09:55 2008 AndreyUpdateSUSNew results for XARM (pdf)
See attachments: pdf-presentation with plots
in "true" axes Q_ETMX and Q_ITMX, and seismic
 New_Results_XARM.pdfAccel-Seismic_10AM.pdf 
  287   Wed Jan 30 20:39:31 2008 robUpdateDMFseisBLRMS

In order to reduce the probability of [COLOR=red]seisBLRMS[/COLOR]
  
  290   Fri Feb 1 10:43:05 2008 JohnUpdateEnvironmentConstruction workThe boys next door have some [URL=http://dziban.ligo.caltech.edu:40/40m/?mode=full&reverse=0&reverse=1&npp=20&subtext=hammer]bigger
noisier[/URL] toys.
 DSC_0433.JPG 
ELOG V3.1.3-