40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 29 of 170  Not logged in ELOG logo
Entry  Wed May 31 12:58:30 2017, Eric Gustafson, Update, LSC, Running the 40 m PD Frequency Response Fiber System; Hardware and Software Overall_schematic_D1300603-v2.pdf
Entry  Sat May 27 10:26:28 2017, Kaustubh, Update, General, Transimpedance Calibration ET-3040_test_transimpedance.pdfET-3010_test_transimpedance.pdfFormula_for_Transimpedance.pdf
Entry  Thu May 25 16:42:41 2017, jigyasa, Update, Computer Scripts / Programs, Making pylon installation on shared directory 
    Reply  Thu May 25 18:37:11 2017, jigyasa, Update, Computer Scripts / Programs, Making pylon installation on shared directory 
Entry  Wed May 24 18:19:15 2017, Kaustubh, Update, General, ET-3010 PD Test PD_test_setup.pngET-3010_test.pdfET-3010_test.zip
Entry  Tue May 23 18:09:18 2017, Kaustubh, Configuration, General, Testing ET-3010 PD 
Entry  Fri May 19 19:18:53 2017, Kaustubh, Summary, General, Testing of the new Photo Detectors ET-3010 and ET-3040 IMG_20170519_173247922.jpgIMG_20170519_173253252.jpgIMG_20170519_173300174.jpgPD_test_setup.png
    Reply  Mon May 22 18:20:27 2017, Kaustubh, Summary, General, Testing of the new Photo Detectors ET-3010 and ET-3040 ET-3040_test.zipET-3040_test.pdf
Entry  Mon May 22 15:01:41 2017, jigyasa, Update, telescope design, Updated Telescope design with 1'' eye piece 1incep.pdf
Entry  Mon May 22 10:15:14 2017, jigyasa, Summary, telescope design, Lens tubes and object distances Pictures1.pdf
Entry  Thu May 18 15:20:29 2017, jigyasa, Summary, telescope design, Telescope Design for the Gig-E cameras 6x
Entry  Thu Apr 27 17:55:33 2017, Steve, Update, Cameras, which camera to use for IR scatterring pictures P4270081RAWolym.jpgImg0344.jpg
    Reply  Mon May 1 17:14:58 2017, Steve, Update, Cameras, ETMY & MC2 ccd cameras removed 
    Reply  Fri May 5 08:41:42 2017, Steve, Update, Cameras, MC2 resonant pictures P5040028MC2c.jpgIMG_3682.JPGIMG_3688.JPG
       Reply  Wed May 17 11:10:31 2017, Steve, Update, Cameras, MC2 CCD video camera back in place 
Entry  Wed May 17 08:19:59 2017, Steve, Update, SUS, 4.1M earthquake  eq_4.1_SantaBarbara.png4.1m_Isla_Vista_CA.png
Entry  Mon May 15 19:21:04 2017, Koji, Update, Computer Scripts / Programs, FSSslow / MCautolocker restarted 
Entry  Mon May 15 08:26:43 2017, rana, Update, CDS, SVN up in userapps/cds 
Entry  Fri May 12 18:45:04 2017, rebecca, Update, Cameras, MC2 Pics with Olympus 
Entry  Wed May 10 12:37:41 2017, gautam, Update, CDS, MCautolocker dead 
    Reply  Wed May 10 16:57:52 2017, rana, Update, CDS, MCautolocker dead 
Entry  Mon May 8 21:53:56 2017, rana, Summary, SEI, attempt to get seismic BLRMS minute trend BLRMS_trend.png
Entry  Thu May 4 08:00:54 2017, Steve, Update, safety, safety training 
Entry  Wed May 3 17:16:30 2017, Praful, Update, Electronics, New Altium Schematic Design for Microphone Amp mic_schematicv2.pdf
Entry  Wed Apr 19 15:46:24 2017, gautam, Update, General, 1611/1811 inventory check 
    Reply  Wed May 3 16:02:36 2017, Steve, Update, General, PI pzt inventory check IMG_3678.JPGPIpztETMYgreen.jpg
       Reply  Wed May 3 16:47:45 2017, Koji, Update, General, PI pzt inventory check 
Entry  Wed Dec 9 18:45:58 2015, Koji, Summary, General, Network Topology Check Network_topology_9Dec2015.xlsxNetwork_topology_9Dec2015.pdf
    Reply  Wed May 3 16:00:00 2017, gautam, Summary, General, Network Topology Check Network_topology_3May2017.pdf
Entry  Fri Apr 28 18:01:56 2017, rebecca, Update, Cameras, Attempting to Load Camera Client 
    Reply  Fri Apr 28 22:50:35 2017, johannes, Update, Cameras, Attempting to Load Camera Client 
       Reply  Sun Apr 30 13:24:00 2017, rana, Update, Cameras, Attempting to Load Camera Client 
Entry  Thu Apr 27 16:41:13 2017, Eric Gustafson, Update, LSC, Status of the 40 m PD Frequency Response Fiber System 
Entry  Tue Apr 25 19:35:41 2017, gautam, Update, General, IPCS -q 
Entry  Fri Apr 21 13:59:47 2017, Eric Gustafson, Summary, , 1064 nm Semiconductor Laser Fiber Distribution System and Mirror Tomography 
Entry  Mon Mar 27 20:41:21 2017, rana, gautam, Update, PSL, PMC DAQ assay for feed-forward integration TEK00000.PNG20170327_194931.jpg20170327_204554.jpg
    Reply  Wed Mar 29 11:41:19 2017, gautam, Update, PSL, PMC DAQ assay for feed-forward integration C1ALS_PSLnamespace.pngPMCcheckout.pdfD980352-A-40m_151119.pdf
       Reply  Thu Mar 30 00:16:09 2017, gautam, Update, PSL, PSL NPRO PZT calibration 
          Reply  Mon Apr 3 17:25:13 2017, gautam, Update, PSL, PSL NPRO PZT calibration PDHerr.pdfNPROcalib.pdf
             Reply  Tue Apr 4 17:27:58 2017, rana, Update, PSL, PSL NPRO PZT calibration 
       Reply  Thu Mar 30 18:11:01 2017, rana, Update, PSL, PMC DAQ assay for feed-forward integration 
          Reply  Mon Apr 3 23:07:09 2017, gautam, Update, PSL, PMC DAQ assay for feed-forward integration 
             Reply  Tue Apr 11 00:38:37 2017, gautam, Update, PSL, PMC demod moved off servo board PMC_Ctrl_spec.pdf
                Reply  Wed Apr 12 00:36:53 2017, gautam, Update, PSL, PMC demod moved off servo board PMC_digitalSpec.pdfPMC_DAQ_spectra.pdf
                   Reply  Tue Apr 18 01:01:03 2017, gautam, Update, PSL, PMC OLTF measured, DAQ channels calibrated PMCspectra_calibrated.pdfPMC_MEDMs.png
                      Reply  Tue Apr 18 16:10:00 2017, gautam, Update, PSL, PMC OLTF measured, DAQ channels calibrated PMC_OLTF_170418.pdf
                         Reply  Tue Apr 18 23:37:15 2017, rana, Update, PSL, PMC OLTF measured, DAQ channels calibrated 
                         Reply  Wed Apr 19 15:13:30 2017, gautam, Update, PSL, PMC/MCL multicoherence PMC_MCL_multicoherence.pdf
Entry  Thu Apr 13 19:54:07 2017, rana, Update, DAQ, checkup on minute trends BRLMS-trend.png
Entry  Thu Apr 13 09:48:37 2017, Steve, Update, SUS, ITMY-UL and ETMX sensors ITMY.pngITMY-UL.pngETMX?.png
Entry  Mon Apr 10 16:00:26 2017, rebecca, Update, Cameras, Pylon installation warning 
    Reply  Mon Apr 10 18:42:09 2017, johannes, Update, Cameras, Pylon installation warning 
Entry  Mon May 2 17:11:55 2016, rana, Update, COC, RC folding mirrors 
    Reply  Wed May 18 01:10:22 2016, gautam, Update, COC, Finesse modelling arms.pdfPRC.pdfSRC.pdfFinesse_model.zip
       Reply  Tue May 24 22:49:02 2016, gautam, Update, COC, Finesse modelling - mode overlap scans 9x
          Reply  Tue May 24 23:17:37 2016, ericq, Update, COC, Finesse modelling - mode overlap scans 
             Reply  Thu Jun 16 15:57:46 2016, gautam, Update, COC, Contrast as a function of RoC of ETMX contrastDefect.pdffinesseCode.zip
                Reply  Thu Jun 16 18:42:12 2016, rana, Update, COC, Contrast as a function of RoC of ETMX 
                   Reply  Thu Jun 16 23:02:57 2016, gautam, Update, COC, Contrast as a function of RoC of ETMX contrastDefect.pdf
                      Reply  Mon Jun 20 01:38:04 2016, rana, Update, COC, Contrast as a function of RoC of ETMX 
                         Reply  Mon Jun 20 18:07:15 2016, gautam, Update, COC, Contrast as a function of RoC of ETMX contrastDefectComparison.pdf
             Reply  Tue Jun 28 16:06:09 2016, gautam, Update, COC, RC folding mirrors - further checks C1_HOMcurves_Y.pdfC1_HOMcurves_DR.pdf
                Reply  Thu Jun 30 16:21:32 2016, gautam, Update, COC, Sideband HOMs resonating in arms image.jpegC1_HOMcurves_Y.pdfC1_HOMcurves_X.pdf
                Reply  Sat Aug 13 18:25:22 2016, gautam, Update, COC, RC folding mirrors - Numerical review PRX_consolidated.pdfSRX_consolidated.pdfGouy_PRC.pdfGouy_SRC.pdf
                   Reply  Tue Aug 16 11:51:43 2016, gautam, Update, COC, RC folding mirrors - Numerical review PRC_consolidated.pdfSRC_consolidated.pdfGouyPRC.pdfGouySRC.pdf
                      Reply  Tue Aug 16 16:38:00 2016, gautam, Update, COC, RC folding mirrors - Numerical review PRC_consolidated.pdfSRC_consolidated.pdfGouyPRC.pdfGouySRC.pdf
                         Reply  Wed Aug 17 14:37:36 2016, gautam, Update, COC, RC folding mirrors - Numerical review PRG.pdf
                            Reply  Wed Aug 17 16:28:46 2016, Koji, Update, COC, RC folding mirrors - Numerical review 
                            Reply  Mon Nov 21 15:34:24 2016, gautam, Update, COC, RC folding mirrors - updated specs Recycling_Mirrors_Specs_Nov2016.pdf
                               Reply  Thu Feb 23 10:59:53 2017, gautam, Update, COC, RC folding mirrors - coating optimization PR3_R_170222_2006.pdfPR3_123_TOnoise_170222_2203.pdfPR3_123_Layers_170222_2203.pdfPR3AR_R_170222_2258.pdfPR3AR_123_Layers_170222_2258.pdf
                                  Reply  Tue Mar 14 10:56:33 2017, gautam, Update, COC, RC folding mirrors - coating optimization PR3_R_170313_1701.pdfPR3AR_123_Layers_170313_1701.pdfPR3AR_R_170313_1752.pdfPR3AR_123_Layers_170313_1752.pdf
                                     Reply  Mon Apr 10 15:37:11 2017, gautam, Update, COC, RC folding mirrors - v3 of specs uploaded  8x
Entry  Tue Jun 10 11:54:36 2014, Zach, Configuration, Wiki, DokuWikis are still down 
    Reply  Tue Jun 10 19:11:27 2014, Evan, Configuration, Wiki, DokuWikis are back up 
       Reply  Wed Jun 11 05:16:14 2014, Zach, Configuration, Wiki, DokuWikis are back up 
          Reply  Wed Jun 11 10:15:15 2014, Evan, Configuration, Wiki, DokuWikis are back up 
             Reply  Wed Jun 11 20:09:37 2014, Zach, Configuration, Wiki, DokuWiki situation 
             Reply  Mon Aug 11 23:50:38 2014, rana, Configuration, Wiki, DokuWikis are back up 
                Reply  Mon Apr 10 15:22:46 2017, rana, Configuration, Wiki, DokuWikis are back up 
Entry  Fri Apr 7 13:46:23 2017, Steve, Update, SUS, ETMX enclosure feedthough bad.jpggood.jpg
Entry  Thu Apr 6 15:35:44 2017, Steve, Update, PEM, envioirmental noise 
Entry  Mon Apr 3 17:09:47 2017, gautam, Update, CDS, C1PSL burt-restored 
Entry  Sun Apr 2 23:14:30 2017, rana, Update, Computer Scripts / Programs, nodus update/upgrade/reboot 
Entry  Fri Mar 31 16:10:33 2017, Steve, Update, Treasure, Les Guthman  
Entry  Fri Mar 31 10:16:07 2017, Steve, Update, safety, laser safety glasses annual inspection march2017.jpg2017march.jpg
Entry  Wed Mar 29 16:38:00 2017, Steve, Omnistructure, Treasure, sus fiber illluminated fiber.jpg
    Reply  Thu Mar 30 10:41:56 2017, rana, Omnistructure, Treasure, sus fiber illluminated 
Entry  Wed Mar 29 09:24:28 2017, Steve, Update, lore, summery pages 
Entry  Mon Jan 16 21:03:47 2017, rana, Summary, IOO, MCL / MCF / Calibration c1ioo_zoom_MCLF.pngMCL.pdf
    Reply  Wed Jan 18 12:34:21 2017, ericq, Summary, IOO, MCL / MCF / Calibration 
       Reply  Wed Jan 25 18:18:08 2017, Koji, Summary, IOO, MCL / MCF / Calibration 
    Reply  Fri Mar 24 12:21:27 2017, gautam, Summary, IOO, MCL / MCF / Calibration 6x
       Reply  Mon Mar 27 12:48:36 2017, rana, Summary, IOO, MCL / MCF / Calibration 
          Reply  Mon Mar 27 22:40:44 2017, Koji, Summary, IOO, MCL / MCF / Calibration 
Entry  Mon Mar 27 20:29:05 2017, rana, Summary, DetChar, Summary pages broken again 
Entry  Mon Mar 13 16:47:41 2017, Steve, Update, PEM, Y-arm air conditon belts replaced 
    Reply  Mon Mar 27 16:01:55 2017, Steve, Update, PEM, X arm AC set to 68F 
Entry  Tue Mar 21 15:13:44 2017, gautam, Update, IMC, IMC input beam mode matching IMG_7220.JPGIMC_ModeMatch.pdfsingleLensSensitivity.pdfsensitivity.pdfIMCmodeMatch.m
    Reply  Tue Mar 21 21:59:48 2017, gautam, Update, IMC, IMC input beam mode matching IMG_3654.JPGIMG_3655.JPG
       Reply  Wed Mar 22 00:33:00 2017, gautam, Update, IMC, IMC length offset nulling offsetInvestigation.pdfoffset_summing_amp.pdf
          Reply  Wed Mar 22 16:58:25 2017, gautam, Update, IMC, WFS sensing matrix measurements 
             Reply  Thu Mar 23 01:44:53 2017, gautam, Update, IMC, WFS sensing matrix measurements IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfTFsummary.pdfIMC_WFS_170322.xlsx.zip
                Reply  Thu Mar 23 08:43:11 2017, rana, Update, IMC, WFS sensing matrix measurements 
                   Reply  Thu Mar 23 23:38:58 2017, gautam, Update, IMC, MC SUS damping gains stepped down 
                      Reply  Fri Mar 24 11:26:57 2017, gautam, Update, IMC, MC SUS damping gains restored 
                         Reply  Fri Mar 24 19:04:18 2017, gautam, Update, IMC, Seismic feedforward and WFS MCL_comparison.pdfseis_comparison.pdf
Entry  Tue Mar 21 21:21:58 2017, gautam, Update, IOO, WFS filter banks updated MCWFS_screen.png
Entry  Mon Mar 20 11:18:58 2017, gautam, Update, CDS, No internet connectivity on control room machines 
    Reply  Mon Mar 20 14:39:44 2017, gautam, Update, CDS, No internet connectivity on control room machines 
Entry  Thu Oct 13 23:58:38 2011, Koji, Update, LSC, fixing REFL165  PA131612.jpgPA131618.jpg
    Reply  Sat Oct 15 16:42:08 2011, Koji, Update, LSC, Testing REFL165  REFL165_test_111014_KA.pdfREFL165_transimpedance2.pdf
       Reply  Sat Oct 15 17:06:20 2011, Koji, Update, LSC, Installation REFL165  
       Reply  Sun Oct 16 02:30:00 2011, rana, Update, Electronics, Testing REFL165  
    Reply  Wed Mar 1 17:25:28 2017, Steve, Update, LSC, MCREFL condition pictures IMG_3646.JPGmcRefl_1.jpgmcRefl_3.jpgmcRefl_5.jpg
       Reply  Fri Mar 17 14:49:09 2017, gautam, Update, LSC, MCREFL condition pictures IMG_7219.JPGMCREFL_X.pdfMCREFL_Y.pdf
Entry  Tue Mar 14 09:08:11 2017, Steve, Update, Optical Levers, ETMX HeNe is dead this_morning.png
    Reply  Tue Mar 14 15:05:18 2017, Steve, Update, Optical Levers, history of ETMX oplev laser ETMX_1103P_3y.png
       Reply  Fri Mar 17 10:47:16 2017, Steve, Update, Optical Levers, ETMX oplev laser replaced 
Entry  Tue Mar 14 10:40:30 2017, Steve, Update, SUS, OSEM filters are in filters.jpg
Entry  Thu Feb 23 15:48:43 2017, johannes, Update, Computers, c1psl un-bootable scope_PDA520_ITM_aligned_ETM_misaligned.pngscope_PDA520_ITM_slightly_misaligned.pngpmc_trans_last10days.png
    Reply  Thu Feb 23 18:52:53 2017, rana, Update, Computers, c1psl un-bootable 
       Reply  Thu Feb 23 19:44:48 2017, johannes, Update, Computers, c1psl un-bootable slow_startup_logs.tar.gz
          Reply  Fri Feb 24 20:38:01 2017, johannes, Update, Computers, c1psl boot-stall culprit identified 
          Reply  Tue Feb 28 01:28:52 2017, johannes, Update, Computers, c1psl un-bootable 
             Reply  Wed Mar 8 18:18:51 2017, johannes, Update, Computer Scripts / Programs, loss script 
                Reply  Thu Mar 9 22:28:11 2017, johannes, Update, Computer Scripts / Programs, loss script 
                   Reply  Fri Mar 10 11:37:25 2017, gautam, Update, Computer Scripts / Programs, loss script 
                      Reply  Fri Mar 10 19:48:56 2017, johannes, Update, Computer Scripts / Programs, loss script 
                         Reply  Sat Mar 11 20:11:58 2017, johannes, Update, Computer Scripts / Programs, loss script 
Entry  Thu Mar 9 15:25:12 2017, Koji, Update, General, IMC/XYarms aligned/locked 
    Reply  Thu Mar 9 17:26:43 2017, Steve, Update, General, attempted ETMY picture taking 
       Reply  Thu Mar 9 20:11:04 2017, Koji, Update, General, attempted ETMY picture taking P3090032.JPG
          Reply  Fri Mar 10 18:00:22 2017, Steve, Update, General, attempted ETMY picture taking P3100044.JPGP3090024.JPG
Entry  Thu Mar 9 20:38:19 2017, rana, Configuration, IOO, MC lock acquisition settings changed; no more HOM locks 
ELOG V3.1.3-