40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 299 of 335  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  1833   Wed Aug 5 09:48:05 2009 albertoUpdateLockingIFO Alignment


   
        
            
 2009-08-09_FSStransPD.png2009-08-09_FSreflPD.png 
  1832   Wed Aug 5 09:25:57 2009 AlbertoDAQComputersfb40m is upFB40m up and running again after restarting
the DAQ.
  
  1831   Wed Aug 5 07:33:04 2009 steveDAQComputersfb40m is down    
  1830   Tue Aug 4 23:03:56 2009 albertoUpdateLockingIFO AlignmentAfter the mini boot fest that Jenne did
today, I checked whether that fixed the overflow
issues we yesterday prevented the alignemnt
  
  1829   Tue Aug 4 17:51:25 2009 peteUpdateComputersRCG workKoji, Peter
 
We put a simple pendulum into the
  
  1828   Tue Aug 4 16:12:27 2009 robUpdateComputersmini boot fest


   
        
            
  
  1827   Tue Aug 4 15:48:25 2009 JenneUpdateComputersmini boot festLast night Rana noticed that the overflows
on the ITM and ETM coils were a crazy huge
number.  Today I rebooted c1dcuepics,
  
  1826   Tue Aug 4 13:40:17 2009 peteUpdateComputersRCG work - rateKoji, Pete
 
Yesterday we found that the channel
  
  1825   Tue Aug 4 11:54:20 2009 JenneUpdateIOOMC_trans readout on LOCK_MC screen now normalizedThe MC_trans QPD Pitch and Yaw readout
on the Lock_MC screen are now normalized
by the trans_sum. I used the method described
  
  1824   Tue Aug 4 11:45:29 2009 ZachUpdateCamerasGigE Phase CameraThe camera wasn't working because the router
has no built-in dhcp server.  We had
to manually start the server after rebooting
  
  1823   Mon Aug 3 22:54:53 2009 Jenne, Koji, ranaUpdateIOOMC_trans is now better, but not bestJenne, Koji,
Rana
 P8030099_copy.JPGP8030102_copy.JPG 
  1822   Mon Aug 3 18:56:59 2009 ZachUpdateCamerasGigE Phase CameraWhile aligning the optics, we tried to
start up the CCD.  Although nothing
should have changed since the last time I
  
  1821   Mon Aug 3 14:47:53 2009 JenneUpdateIOOMC locks againThe mode cleaner seems to be locking again. 
I've manually unlocked it a few times in
the past 20min, and most of the time it catches
  
  1820   Mon Aug 3 14:15:50 2009 JenneUpdateIOOWFS recenteredI am (was) able to get the mode cleaner
mostly locked, but because WFS2 wasn't centered,
the MC would drift, then lose lock. 
  
  1819   Mon Aug 3 13:47:42 2009 peteUpdateComputersRCG workAlex has firewalled megatron.  We
have started a framebuilder there and added
testpoints.  Now it is possible to take
  
  1818   Mon Aug 3 12:57:09 2009 AlbertoUpdatePSLMC unlocked


   
        
            
  
  1817   Mon Aug 3 01:08:20 2009 AlbertoUpdatePSLMC unlockedFriday afternoon the mode cleaner got unlocked.
Then some adjustment of the MC1 bias sliders
locked it again. The driftmon showed the
  
  1816   Fri Jul 31 11:04:42 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI put the flying-component circuit in a
box; a photo is attached. I also measured
the impedance; it looks exactly the same
 BoxPic.pngBoxPic2.png 
  1815   Fri Jul 31 09:52:38 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateI was able to make an impedance measurement
of the flying-component circuit using Koji's
 BuiltCkt2_Simplified_EOM.pngImpedanceAG4395A_with10pF.pngBuiltCkt2_Simplified_EOM_R.pngImpedanceAG4395A_withEOM.png 
  1814   Thu Jul 30 21:26:16 2009 ranaUpdateIOOMC Drumhead modeI used COMSOL 3.5a to do a FEA of one of the
MC flat mirrors. Should be close to the same
for all the mirrors.
 mc2drum.png 
  1813   Thu Jul 30 19:55:23 2009 KojiUpdateGeneralMultiply Resonant EOM Update


   
        
            
 imepedance.pngimpedance_meas.jpg 
  1812   Thu Jul 30 03:10:18 2009 robUpdateIOOMC tweaked furtherI tilted the periscope beam and aligned
the MC.  Now the spot at the Faraday
entrance is near the center of the aperture
  
  1811   Wed Jul 29 19:46:04 2009 rana, albertoUpdatePEMDents = Bad??[B]It looks like the MC2 chamber and/or stack
has been jarred and shifted. Please be careful
and use much less force and speed around
  
  1810   Wed Jul 29 19:41:58 2009 ChrisConfigurationGeneralEUCLID-setup configuration changeDavid and I were thinking about changing
the non-polarizing beam splitter in the EUCLID
setup from 50/50 to 33/66 (ref picture). 
 EUCLID.png 
  1809   Wed Jul 29 19:31:17 2009 ranaConfigurationComputerselog restartedJust now found it dead. Restarted it. Is
our elog backed up in the daily backups?
  
  1808   Wed Jul 29 14:56:44 2009 JenneUpdatePEMMiniEarthquakes due to constructionThe construction people next door seem
to be getting pretty excited about pounding
things lately.  At my desk the floor
  
  1807   Wed Jul 29 14:22:33 2009 ZachUpdateCamerasGigE Phase CameraThis week, Joe and I have been setting
up the laser and optics.  The mephisto
laser is emitting a very ugly beam that we
  
  1806   Wed Jul 29 13:15:35 2009 ClaraUpdatePEMDents = Bad??I was in the lab last night accelerometerizing
and noticed some dents on the tubes that
stick out horizontally from the MC2 optical
 small_dent.pngbig_dent1.pngbig_dent2.png 
  1805   Wed Jul 29 12:14:40 2009 peteUpdateComputersRCG workKoji, Pete 
Yesterday, Jay brought over the IO
box for megatron, and got it working. 
 TF090729_1.pngTF090729_1.png 
  1804   Wed Jul 29 12:00:49 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateFor the past couple of days I have been
trying to understand and perform Koji's
method for impedance measurement using
 ImpedanceTestingPhysicalSetup.pngImpResponses.pngImpedanceTestingSetup.pngImpedanceTestingCktDiagram.png1nF.png 
  1803   Wed Jul 29 11:58:57 2009 AlbertoUpdatePSLMC not lockingThis morning I found the Mode Cleaner unlocked.
I check the sliders for the mirrors
bias and they have not changed. Also the
  
  1802   Wed Jul 29 11:15:06 2009 steveBureaucracySAFETYKevin receives safety trainingKevin Vigue, our high school summer student
went through the 40m specific safety traning
yesterday.
  
  1801   Tue Jul 28 18:32:21 2009 KojiUpdateCDSRCG workPeter and Koji,

We are constructing a setup for the
  
  1800   Tue Jul 28 16:03:14 2009 ClaraUpdatePEMGuralp Seismometer cable pin diagramI mapped out the corresponding pins on
both ends of the Guralp seismometer cable.
Here is the diagram:
 guralp_pin_diagram.png 
  1799   Mon Jul 27 19:55:19 2009 KojiHowToIOOLens selection: plano-convex? or bi-convex?Q. When should we use plano-convex lenses,
and when should we use bi-convex?
As I had the same question from Jenne
  
  1798   Mon Jul 27 17:48:44 2009 JenneUpdateoplevsETMY oplev is still down for the countETMY oplev is still out of order. 
Hopefully I'll get it under control by tomorrow. 
  
  1797   Mon Jul 27 14:43:34 2009 ChrisUpdate PhotodetectorsI found two ThorLabs PDA55 Si photodetectors
that says detect visible light from DC to
10MHz that I'm going to use from now on. 
  
  1796   Mon Jul 27 14:12:14 2009 ranaSummarySUSTM Coil Noise SpectraRob noticed that the ITMY DAC channels were
saturating occassionally. Looking at the
spectrum we can see why.
 Coils.pdf 
  1795   Mon Jul 27 09:34:07 2009 steveSummaryIOOAligning the mode cleaner


   
        
            
 20dtrend.jpg 
  1794   Sun Jul 26 16:05:17 2009 AlbertoUpdatePSLAligning the mode cleaner


   
        
            
  
  1793   Sun Jul 26 13:19:54 2009 ranaUpdatePSLAligning the mode cleanerI set the MC back to its good alignment
(June 21st) using this
procedure. The trend of the OSEM values
 Untitled.png 
  1792   Sat Jul 25 19:04:01 2009 KojiUpdatePSLAligning the beam to the Faraday


   
        
            
 MC2_Cam.jpg 
  1791   Sat Jul 25 16:04:32 2009 robUpdatePSLAligning the beam to the Faraday


   
        
            
  
  1790   Sat Jul 25 13:49:28 2009 KojiUpdateGeneralMultiply Resonant EOM Update


   
        
            
  
  1789   Sat Jul 25 13:34:58 2009 KojiUpdateGeneralWeek 5/6 Update


   
        
            
  
  1788   Fri Jul 24 21:02:46 2009 AlbertoUpdatePSLAligning the beam to the FaradayThis afternoon I kept working on the alignment
of the beam so that it matches at the same
the PSL periscope, the Mode Cleaner and the
  
  1787   Fri Jul 24 17:47:52 2009 StephanieUpdateGeneralMultiply Resonant EOM UpdateAfter speaking with Rana and realizing
that it would be better to use smaller inductances
in the flying-component circuit (and after
 BuiltCkt2_Picture_Simplified.pngBuiltCkt2_Simplified.pngSimplified.png 
  1786   Fri Jul 24 17:20:48 2009 JenneUpdateoplevsETMY oplev is iffyETMY oplev is currently a work in progress. 
The HeNe beam is hitting the photodiode,
but the spot size there is pretty much the
  
  1785   Fri Jul 24 11:04:11 2009 AlbertoConfigurationComputerselog restartedThis morning I found the elog down. I restarted
it using the procedure in the wiki.
  
  1784   Thu Jul 23 20:30:23 2009 AlbertoUpdatePSLBeam aligned to the FaradyAfter yesterday's changes in the MC cavity
state today it was necessary to optimize
the alignment to the Faraday.
  
ELOG V3.1.3-