  10795   Sat Dec 13 00:35:11 2014 ranaUpdateElectronicsXend QPD whitening board modified 
 16 bit. There aren't any 14-bit
ADCs anywhere in LIGO. The aLIGO suspensions
  
  10800   Mon Dec 15 22:40:09 2014 ranaSummaryPSLPMC restored Found that the PMC gain has been
set to 5.3 dB instead of 10 dB since 9 AM
this morning, with no elog entry.
 SadToastFace.jpg 
  10828   Mon Dec 22 15:11:08 2014 ranaUpdateIOOMC Error Spectrache tristezza  
What we want is to have the high
  
  10842   Wed Dec 24 08:25:05 2014 ranaConfigurationIOOnotes on MC locking I've updated the scripts for the
MC auto locking. Due to some permissions
issues or general SVN messiness, most of
  
  10844   Fri Dec 26 18:20:42 2014 ranaUpdateComputer Scripts / ProgramsFSS Slow servo thresh change

    

       
            
  
  10846   Mon Dec 29 21:30:25 2014 ranaUpdateGeneralrecovery
    Control room is at +66 F. Brrrr.

   Alignment of input beam into the IMC
was wacky; locked on HOM.
    Re-aligned
  
  10847   Tue Dec 30 00:46:05 2014 ranaUpdateIOOInvestigations into the mad PCDRIVEKoji and I noticed that there was a comb*
of peaks in the MC and FSS at harmonics of
~37 kHz. Today I saw that this shows up (at
 MC_ERR.pdfplotFSSerr.ipynb.xzMC_ERRcomp.pdf 
  10848   Tue Dec 30 17:26:23 2014 ranaUpdatePSLRelaxation Osc and the NPRO Noise eaterI wonder if the variable bump around 100
kHz can be something about the NPRO and if
the bump we see is the closed loop response
 NE_Mephisto.png 
  10849   Tue Dec 30 20:35:59 2014 ranaSummaryPSLPMC Tune Up
    Calibrated the Phase Adjust
slider for the PMC RF Modulation; did this
by putting the LO and RF Mod out on the TDS
 17.pngPMCcal.ipynb.xzPMC_Osc_Cal.pdf 
  10851   Sun Jan 4 22:08:46 2015 ranaUpdateIOOMC loop characterizations: PZT/EOM crossover * PMC + MC were unlocked when I came
in.
* I fiddled around some more with
 MC_OLGs.pdfMC_xover.pdf 
  10874   Wed Jan 7 21:13:35 2015 ranaUpdateGeneralinane LSCoffsets script removed

    

       
            
  
  10899   Wed Jan 14 02:11:07 2015 ranaSummaryTreasure2-loop Algebra LoopologyI show here
the matrix formalism to calculate analytically
the loop TF relationships for the IMC w/
 FSSloop.pdfFSSloop.png 
  10949   Wed Jan 28 14:19:02 2015 ranaUpdateLSCTransitioned DARM to AS55QWhy AS55/(TRX + TRY) instead of just TRX?
Isn't (TRX+TRY) controlled by CARM?
  
  10988   Sun Feb 8 21:54:50 2015 ranaSummaryPSLISS AOM driver checkThis is good
news. It means that the driver probably won't
limit the response of the loop - I expect
  
  10998   Wed Feb 11 00:07:54 2015 ranaUpdateLSCLock Loss plotHere is a lock loss from around 11 PM tonight.
Might be due to poor PRC signals.  
 1107673198.png1107673198.png 
  11002   Wed Feb 11 16:49:41 2015 ranaUpdateelogELOGD restartedNo elog
response from outside and no elogd process
  
  11008   Thu Feb 12 01:00:18 2015 ranaUpdateLSCRFPD spectraThe nonlinearity in the LSC detection chain
(cf T050268)
comes from the
  
  11009   Thu Feb 12 01:43:09 2015 ranaUpdateLSCNew Locking Paradigm - LSC model changesWith the  TF.gif 
  11018   Thu Feb 12 23:40:12 2015 ranaUpdateIOOBounce / Roll stopband filters added to MC ASC filter banks   59.png 
  11020   Fri Feb 13 03:28:34 2015 ranaUpdateLSCNew Locking Paradigm - Loop-gebraNot
so fast!

In the drawing,
the FF path should actually be summed in
  
  11025   Fri Feb 13 18:56:44 2015 ranaUpdateElectronicsSecond QPD Whitening Switch enabledDepends on the plots of the whitening I
guess; if its low freq sat, then we lower
the light level with ND filters. If its happening
  
  11034   Sun Feb 15 20:55:48 2015 ranaSummaryLSC[ELOG LIST] 3f modulation cancellationI wonder if DRMI can be locked on 3f using
this lower 55 MHz modulation depth. It seems
that PRMI should be unaffected, but that
  
  11040   Mon Feb 16 21:52:51 2015 ranaHowToTreasurebig Dataviewer windowsFollowing this
entry, I have made the same change in
the controls account on rossa:
 bigDV.png 
  11057   Mon Feb 23 08:06:59 2015 ranaUpdateASCQPD frontend code unifiedMight have to also get the OL screens that
go with this new code to see, but the calibrations
don't go into the matrix, but rather
  
  11067   Wed Feb 25 14:18:28 2015 ranaUpdateLSCDelay line re-installed, measurements round 2The Schnupp asymmetry is definitely not
an important parameter (no need for Koji
to explode). It only serves to give us a
  
  11071   Wed Feb 25 23:48:57 2015 ranaUpdateLSCsome thoughts
Comparing just the 2 cases with
locking on 33, it seems that the 55 MHz gain
has changed by 14 dB instead of the 10 dB
  
  11081   Fri Feb 27 01:59:57 2015 ranaHowToLSCiPython Notebook for LSC Sensing MatrixI
have adapted one of Evan's python scripts
 Plots_1109056456.pdfRadar_1109056456.pdf 
  11096   Wed Mar 4 00:50:36 2015 ranaBureaucracyTreasureTransitioned DARM to AS55Q, some other workJust
in case there was some confusion, the champagne
on my desk is not to be opened
  
  11103   Thu Mar 5 19:13:17 2015 ranaUpdateCDSmxStream all restart at ~7:10 pm    
  11106   Fri Mar 6 00:59:13 2015 ranaSummaryIOOMC alignment not drifting; PSL beam is driftingIn the attached plot you can see that the
MC REFL fluctuations started getting larger
on Feb 24 just after midnight. Its been bad
 MCdrfit.png 
  11107   Fri Mar 6 02:10:35 2015 ranaUpdateLSCArm length remeasurementThis has been done before:

http://nodus.ligo.caltech.edu:8080/40m/6938

Arm length measurements and g-factor
  
  11112   Fri Mar 6 19:54:15 2015 ranaSummaryIOOMC alignment not drifting; PSL beam is driftingMC Refl
alignment follow up: the alignment from last
 Untitled.png 
  11121   Sun Mar 8 13:51:41 2015 ranaUpdateLSCError signal blending for CARM/DARM transitionsAccording
to the official rules, we only need 8 seconds
  
  11140   Fri Mar 13 14:11:59 2015 ranaUpdateLSC6+ CARM->REFL transitions, 1 DARM->AS transitionSince the DARM_OUT signal is only 500 counts_peak,
I don't see why AS55 whitening needs
to be switched on.
  
  11141   Fri Mar 13 23:49:28 2015 ranaUpdatePSLRelaxation Osc and the NPRO Noise eaterAnother thought about the mystery PCDRIVE
noise: we've been thinking that it could
be some slow death inside the NPRO, but it
  
  11142   Sat Mar 14 00:12:18 2015 ranaUpdateSUSOplevs huh?The oplev situation still seems unresolved
- notice this DTT. I guess there are still
inconsistencies in the screens / models etc.
 burp.png 
  11155   Sun Mar 22 13:53:44 2015 ranaUpdateSUSITMX alignment jumpsSo, was there real shifting in the ITMX
alignment as seen in the DV trend or just
mis-diagnosis from the ETMX violin mode?
  
  11161   Mon Mar 23 19:30:36 2015 ranaUpdateComputer Scripts / Programsrsync frames to LDAS clusterThe rsync job to sync our frames over to
the cluster has been on a 20 MB/s BW limit
for awhile now.
  
  11202   Sat Apr 4 17:54:03 2015 ranaUpdateModern ControlPreliminary PRMI angular Wiener resultsThis
is a very cool result. I'm surprised
  
  11204   Mon Apr 6 13:23:40 2015 ranaUpdatePEMjackhammering at ETMXUnfortunately, this kind of trend plot
is not detailed enough to know if something
has gone bad in a quantitative way. But at
  
  11228   Mon Apr 20 21:26:46 2015 ranaUpdateElectronicsLow noise pre-amps: returned+1 to both Evan and Zach for prompt info
and +2 to you for getting more stuff than
you started looking for. -2 karma to
  
  11231   Tue Apr 21 15:03:27 2015 ranaUpdateOptical Levers1103P noise measurementIt doesn't work with the lens in there,
but it seems pretty close. Please leave it
as is and I'll play with it after 5 today.
  
  11232   Tue Apr 21 21:46:34 2015 ranaUpdateOptical Levers1103P noise measurementTo test what the inherent angular noise
of the HeNe 1103P laser is, we're testing
it on a table pointing into the BS OL QPD
 oplev1103P.pngL1-ISI_SUS_ODC_FC496F_SPECTRUM-1113523216-86400.png 
  11237   Wed Apr 22 17:04:11 2015 ranaUpdateElectronicsMC REFL PD back from the deadJust randomly found this old entry from
3 years ago. We should
  
  11240   Thu Apr 23 21:05:23 2015 ranaUpdateComputer Scripts / ProgramsCDSutils upgrade undoneQ: please update this Wiki
page with the go-back procedure:
  
  11244   Fri Apr 24 18:13:36 2015 ranaUpdateGeneraltorque for 1/4-20For 1/4-20 bolts made of 18-8 Stainless
Steel, the recommended torque varies
from 65-100 inch-pounds, depending upon the
  
  11246   Fri Apr 24 23:40:15 2015 ranaUpdateSUSPRM and BS oplev laser replacedRecently, Steve replaced the HeNe which
was sourcing the BS & PRM OL. After replacement,
 BSOL.pdf 
  11247   Sat Apr 25 00:20:16 2015 ranaUpdateCDSmegatron python autoMC cronUpgraded python on megatron. Added lines
to the crontab to run autoMX.py. Edited crontab
to have a PYTHONPATH so that it can run .py
  
  11250   Sat Apr 25 22:17:49 2015 ranaUpdateCDSMXstream restart script working (beta)Since python from crontab seemed intractable, I replaced autoMX.py   
  11251   Sun Apr 26 00:08:56 2015 ranaHowToelogTroubles with putting plots in external locationsIf it all possible, don't use links
to your home directory. Its not robust. It
would be like if you clicked on your Google