40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 297 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  11342   Mon Jun 1 20:05:36 2015 ranaUpdateCDSRCG Upgrade Imminent

  
  11360   Mon Jun 15 20:36:48 2015 ranaUpdateIOOIOO QPDs centredafter re-aligning the beam into the PMC,
I touched up the steering mirros into the
IOO QPDs so that the beams are now centered
 Untitled.png 
  11367   Sun Jun 21 13:21:03 2015 ranaUpdatePEMWilcoxon Accelerometer Huddle TestTo improve our sensor
noise estimate, the ACC cables should
be clamped using a rubber pad and a big dog
  
  11370   Mon Jun 22 14:53:37 2015 ranaSummaryLSCX/Y green beat mode overlap measurement redone
Why is there a factor of 20 power
difference? Some of it is the IR laser power
difference, but I thought that was just a
  
  11383   Tue Jun 30 05:47:38 2015 ranaUpdateLSCUse BALUNs


  
  11519   Thu Aug 20 11:09:10 2015 ranaUpdateIOOsome points about seismic FF
When plotting the subtraction performance,
we mainly care about the 0.5 - 10 Hz band,
so we care about the RMS in this band. Don't
  
  11538   Fri Aug 28 19:05:53 2015 ranaUpdateIOOIMC TweakWell, green looks better than blue, but
it makes the PCDRIVE go high, which means
its starting to saturate the EOM drive. So
  
  11539   Fri Aug 28 20:15:49 2015 ranaUpdateIOOMC2 -> MCL Actuator TF


  
  11540   Fri Aug 28 20:20:26 2015 ranaUpdatePEMGur interface box cableTo help find out if Steve really melted
the inside of our precious seismometer, lets
hook it up using the handheld seismo wand
  
  11542   Sun Aug 30 00:03:13 2015 ranaUpdateIOOMCL Wiener Feedforward Final ResultsSomehow it seems like the ELOG makes all
of the thumbnails way too big by default.
Did we get some sneaky upgrade recently?
  
  11545   Sun Aug 30 13:31:48 2015 ranaUpdateIOOMCL Wiener Feedforward Final ResultsI'm not totally sure, but by eyeball,
this seems like the best online MCL reduction
we've ever had. Nice work.
  
  11560   Wed Sep 2 23:50:00 2015 ranaUpdatePSLPMC LO dyingLet's order a pair of 35.5 MHz Wenzel
for this guy and package like Rich has done
for the WB low noise oscillators.
 PMCLO.png 
  11561   Thu Sep 3 00:14:09 2015 ranaConfigurationIOOIMC fast gain change for lock acqThe IMC often was making that scratchy
noise when first catching lock and sometimes
breaking. Thinking of the crappy crossover
  
  11562   Thu Sep 3 00:29:45 2015 ranaUpdateASCASS X not workingran the ON script several times and it
kept pulling it away from good alignment,
even when TRX was > 0.9.
  
  11564   Thu Sep 3 02:12:08 2015 ranaUpdateCDSSimulink Webview updatedBack in 2011, JoeB wrote
some entries on how to automatically
update the Simulink webview stuff.
  
  11565   Thu Sep 3 02:30:46 2015 ranaUpdateCDSc1cal time reduced by deleting LSC sensing matrixI experimented with removing somethings
here and there to reduce the c1cal runtime.
Eventually I deleted the LSC Sensing Matrix
  
  11567   Thu Sep 3 13:25:40 2015 ranaUpdateCDSSimulink Webview updatedadded the cron script for this to megatron
to run at 8:44 AM each morning. Here's
the new MegaCron attached :-()-
 crontab_150903.rtf 
  11569   Thu Sep 3 19:52:24 2015 ranaSummarySUSSUS drift monitorSince Andrey's SUS Drift mon screen
back in 2007, we've had several versions
which used different schemes and programming
 07.png 
  11570   Fri Sep 4 00:58:29 2015 ranaUpdateCDSsoldering the Generic Pentek interface boardQ and Ignacio were taking a second look
at the Pentek interface board which we're
using to acquire the POP QPD, ALS trans,
  
  11578   Fri Sep 4 20:06:23 2015 ranaUpdateLSCDRMI locked on 1F and 3FNice going. I think the LLO / LHO scheme
is to acquire on 1F and then cdsutils avg
to get the 3F offsets. The thinking is that
  
  11580   Mon Sep 7 16:30:56 2015 ranaHowToComputer Scripts / Programsincrease of window border size on RossaFrustrated by the single pixel width of
the windows and how hard that makes it to
drag things around, I explored StackExchange:
  
  11581   Mon Sep 7 18:25:16 2015 ranaConfigurationIOOAOM stage is readyThe new stage missed the right height by
~2 mm. 
  
  11582   Mon Sep 7 19:46:46 2015 ranaUpdatePEMSeismic BLRMS filtersAs it turned out, the "STS" BLRMS
filters were all a mess, so I fixed them
up today:
 T240_150907.png 
  11583   Tue Sep 8 20:30:44 2015 ranaUpdateIOOMC WFS relief re-commissionedI converted our MC WFS relief from CSH
to BASH today. I also added 'wait'
commands and 'echo' commands so that
 WFSrelief.png 
  11585   Wed Sep 9 11:33:58 2015 ranaUpdateSummary PagesSummary Page updates
Made most plots in IOO tab only
plot when MC_TRANS > 10000 using Eve's
MC_LOCK state definition.
added
  
  11588   Thu Sep 10 01:09:20 2015 ranaUpdateLSCMoved LSC sensing matrix notch frequenciesWe looked at the DRMI noise spectrum and
chose new excitation frequencies such that
the lines are lower in frequency than before
 NewLSCnotches.png 
  11592   Sun Sep 13 13:26:00 2015 ranaUpdateIOOLast Wiener MCL subtractionsWhen making the Wiener filter OFF/ON comparisons,
we want to use the median PSD estimates,
not the mean (which is what pwelch gives
  
  11595   Mon Sep 14 21:42:00 2015 ranaUpdateIOOMC Wiener + SummaryI turned on the MCF FF in the OAF today
(we need to fix the labeling of the 'ON'
buttons on the RHS of the screen). The performance
 mcf.pdf 
  11597   Tue Sep 15 01:14:10 2015 ranaSummaryLSCneed to check LSC Whitening switch logic ... againTonight we noticed that the REFL_DC signal
has gone bipolar, even though the whitening
gain is 0 dB and the whitening filter is
  
  11598   Tue Sep 15 15:01:23 2015 ranaSummaryLSCdisabling the LSC AA filters + mod to whiteningWhile investigating the BIO situation with
the LSC machine and the iscaux2 processor
last night, we wondered if maybe the Anti-Aliasing
  
  11607   Wed Sep 16 23:07:06 2015 ranaUpdateElectronicsLSC Whitening board: LP filters added, pictures takenI added the 0.1 uF and 47 nF caps
that I mentioned so that we can now bypass
the AA filters for these channels. (mistakenly
 20150916_221210.jpgout.pdf 
  11616   Fri Sep 18 08:03:53 2015 ranaUpdateLSCRF micky mouse - dodgy DIN connector blocks fixedSteve and I turned on the box this morning
so that the IMC would lock again.

For future reference, remember
  
  11617   Fri Sep 18 08:04:09 2015 ranaUpdateLSCRF micky mouse - dodgy DIN connector blocks fixedSteve and I turned on the box this morning
so that the IMC would lock again.

For future reference, remember
  
  11618   Fri Sep 18 09:06:26 2015 ranaFrogsComputer Scripts / Programsremote data access: volume 1, InfernoTrying to download some data using matlab
today, I found that my ole mDV stuff doesn't
work because its MEX files were built for
  
  11622   Fri Sep 18 19:15:35 2015 ranaUpdateLSCFast ALS troubles - Noise at 36kHzOne the Wiki (https://wiki-40m.ligo.caltech.edu/40mHomePage),
we have a Mech Resonance page for mechanical
frequencies and a PEM page where we want
  
  11623   Fri Sep 18 19:19:49 2015 ranaFrogsComputer Scripts / Programsremote data access: volume 1, InfernoNDS2 restarted after hours long upgrade
process; testing has begun. Let's try
to get some long stretches of MC locked with
  
  11624   Mon Sep 21 00:51:36 2015 ranaUpdateGeneralop340m, autoburt cron =? megatronI modified the perl script which does our
hourly autoburt so that it can run on megatron
instead of op340m (old Solaris machine).
  
  11631   Tue Sep 22 02:11:17 2015 ranaSummaryComputer Scripts / ProgramsFrequency counting algorithmI was going to suggest using a software
PLL, but perhaps averaging gives the same
result. The same ADC signal can be fed to
  
  11646   Fri Sep 25 19:06:13 2015 ranaUpdateSUSETMX IS driftingI don't see any evidence of it getting
more stable. It seems there was a big step
in January, but the problem we were talking
  
  11649   Tue Sep 29 18:03:11 2015 ranaUpdateLSCuse LISOUse LISO - see what it tells you. I would
think that you should make a differential
RC filter to get the right behavior. (e.g.
 Screen_Shot_2015-09-29_at_5.55.34_PM.png 
  11675   Thu Oct 8 21:35:49 2015 ranaUpdateLSCDRFPMI ProgressGive us a lockloss or other kind of time
series plot so we can bask in the glory.
  
  11688   Wed Oct 14 15:59:06 2015 ranaUpdateComputer Scripts / Programsnodus web apache simlinks too softNone of the links here seem to work. I
forgot what the story is with our special
apache redirect 
  
  11696   Sat Oct 17 18:55:07 2015 ranaUpdateLSCDRFPMI Locked for 20 sec in addition
to Koji's words I feel like we should
  
  11711   Fri Oct 23 21:58:10 2015 ranaUpdateSUSMC2 F2P mis-tunedThe OSEMs cannot be used for coil balancing
above ~10 Hz. The main coupling path from
OSEM drive to sensor is not through the mirror
  
  11752   Wed Nov 11 14:06:09 2015 ranaUpdateSUSETMX oplev servo disabledHow many volts does it take to pitch the
ETM by 5 urad?
  
  11774   Tue Nov 17 15:59:23 2015 ranaUpdateSUSITMX UL calmed?Although this noise is bad, we have always
had these kind of humps around the bounce
mode. Our interpretation in the past was
  
  11784   Wed Nov 18 20:49:05 2015 ranaUpdateComputer Scripts / Programsnodus boot getting fullcontrols@nodus|~ > df -h
Filesystem        
          Size  Used
  
  11787   Wed Nov 18 23:40:01 2015 ranaUpdateOptical LeversCalibration of oplevs for ITMY/ETMYOMG. Please try to use larger fonts and
PDF so that we can read the plots.

  
  11796   Sun Nov 22 07:09:01 2015 ranaUpdateIOOIMC fixOn the demod board there is a 10 dB attenuator
(AT1), which lowers the level to -10 dBm
before the ERA-5. Then it should be 10 dBm
  
  11807   Wed Nov 25 04:24:21 2015 ranaUpdateIOOLO level check for the IMC demod boardHmmm. Very non-standard demod. From the
photo, looks like someone did some surgery
with the attenuators (AT1, AT2, AT3) in the
  
ELOG V3.1.3-