  14874   Thu Sep 12 12:42:31 2019 aaronUpdateIOOWFS measurements[rika, aaron]

At Seiji and Gautam's suggestion,
we added an additional RF photodiode (NewFocus
 WFS2_TFs.pdfD755499D-9FDF-4E2B-BFC1-016B459DD35D.jpeg 
  14875   Fri Sep 13 10:36:03 2019 aaronUpdateIOOWFS measurements[rika, aaron]

We are at it again. Rika is setting
up the TF measurement, I'm looking into
 TF-.pngWFS2_TFs.pdf 
  14876   Fri Sep 13 10:53:40 2019 aaronUpdateIOOWFS loop measurementsI'm scripting the WFS sensing matrix
measurements. I haven't really scripted
DTT before, so I'm trying to find documentation
  
  14877   Fri Sep 13 13:03:35 2019 KojiSummaryCDSDIN 96pin to DSUB37 adapter (single) ready for useThe PCB board of the adapter for DIN 96pin
to DSUB37 conversion (single DSUB version)
was delivered yesterday and I quickly soldered
 P_20190912_192109.jpg 
  14878   Mon Sep 16 05:08:04 2019 ranaUpdateIOOWFS loop measurementsnot need to use DTT. I'm attaching
some half-finished notebooks that give the
gist.
 LSCsensingMatrix.ipynbASCsensingMatrix.ipynb 
  14879   Mon Sep 16 09:11:37 2019 gautamSummaryCDSDIN 96pin to DSUB37 adapter (single) ready for useI installed 6 of these
in 1Y2. Three were for PD INTF #1-3, and
I used three more for the AS110, REFL11,
  
  14880   Mon Sep 16 11:55:58 2019 rikaUpdateIOOWFS loop measurements[rika, aaron]

We aligned optics of WFS as it
was. Now auto-locker is working to lock MC.
  
  14881   Mon Sep 16 12:00:16 2019 aaronHowToGeneralMoved some immovable opticsWhen I put away the lenses we had used
for measuring the RF transfer functions of
the QPD heads, I saw that I'd removed
  
  14882   Mon Sep 16 12:38:59 2019 aaronUpdateIOOWFS measurementsI wanted to make a zero model of this circuit
to get a handle on the results. I couldn't
import zero on pianosa, and I tried pip installing
  
  14883   Mon Sep 16 17:53:16 2019 aaronUpdateCamerasMC2 trans camera (?) rotatedWe noticed last week that the MC2 trans
camera has pitch and yaw swapped; I rotated
what I thought is the correct camera by 90
 47D6ED9C-BF21-4D6E-9947-284FE4A336F4.jpeg 
  14884   Mon Sep 16 19:29:24 2019 KojiUpdateCamerasMC2 trans camera (?) rotatedThe left one is analog and 90deg rotated.

See also: This
issue tracker
  
  14885   Mon Sep 16 20:22:19 2019 gautamSummaryCDSUpdate on the Acromag status
Jordan (new Engineer) and Chub
neatened out the cabling at 1Y2/1Y3 today.
After their work, I plugged in all the Dsubs
 acromagChecklist.pdf 
  14886   Tue Sep 17 09:41:48 2019 gautamUpdateIOOWFS loop measurementsLet's
not worry about C1LSC until the c1iscaux
  
  14887   Tue Sep 17 10:34:48 2019 aaronUpdateIOOWFS loop measurementsI'm using the notebooks from rana as
a starting point, and making a script to
measure and fill the WFS sensing matrix.
  
  14888   Tue Sep 17 10:47:44 2019 rikaUpdateIOOWFS loop measurements[aaron, rika]

Once stop the auto-locker and realigned
to make beam to get into QPD again.
 MC2.pdf 
  14889   Tue Sep 17 14:01:46 2019 gautamUpdateCDSdaqd fw deadFor some reason, the daqd_fw service was
dead on FB. This meant that no frames were
being written since Aug 23, which probably
  
  14890   Tue Sep 17 14:43:59 2019 gautamHowToCDSFinal bit bug of the BIO CDS module Came across this while looking up the BIO
situation at 1Y2. For reference, the fix
Koji mentions can be seen in the attached
 Screen_Shot_2019-09-17_at_2.44.41_PM.png 
  14891   Tue Sep 17 21:34:07 2019 gautamUpdateCDSdaqd fw dead no moreSummary:


Frames seem to
be written again.
 RTFEstatus.png 
  14892   Tue Sep 17 23:43:34 2019 KojiSummaryCDSAcromag logic checkerFor the investigation of the latch logic
issue for the CARM CM board, I have made
the LED logic checkers with DB breakout boards.
 digital_checker.pdfIMG_8914.JPG 
  14893   Tue Sep 17 23:46:21 2019 KojiUpdateCDSLatch Enable Logic[Koji Gautam]

We continued to check the latch
logic. Today we found that latch.py didn't
 Screenshot_from_2019-09-17_23-39-35.png 
  14895   Wed Sep 18 12:40:09 2019 gautamUpdateCDSFast BIO Mapping at 1Y2INCORRECT
INFO IN THIS ELOG HAS BEEN REMOVED. SEE THIS
  
  14896   Wed Sep 18 14:45:52 2019 rikaUpdateIOOWFS loop measurements[aaron, rika]

Gettng TFs

In the data
we got yesterday, we can see some filter's
 Screenshot_from_2019-09-18_18-15-34.png 
  14897   Wed Sep 18 15:27:45 2019 gautamUpdateIOOTT cables need to be remadeSummary:

The custom ribbon cables piping
the coil driver board outputs to the eLIGO
 IMG_7945.JPG 
  14898   Thu Sep 19 09:39:30 2019 gautamUpdateIOOTT cables need to be remadeWhile debugging this problem, c1lsc models
crashed. I ran the reboot script this morning
to bring the models back. There was a 0x4000
 CDSoverview.png 
  14899   Thu Sep 19 11:26:18 2019 gautamUpdateIOOTT cables DON'T need to be remadeFalse
alarm - the mistake
was mine. Looking at the schematic
  
  14900   Thu Sep 19 15:59:29 2019 aaronHowToCDSHow to save c1iooNew DIMM cards have arrived. I stored them
in the digital cabinet along y arm.
  
  14901   Thu Sep 19 21:23:51 2019 gautamUpdateCDSFast BIO splicing re-implemented at 1Y2[KA,
GV]
 1Y2_FAST_BIO_WIRING_MAP.pdfIMG_7949.JPGREFL165.pdf 
  14902   Fri Sep 20 11:39:04 2019 gautamUpdateOptical LeversETMX Oplev HeNe DeadWhile working on recovering interferometer
alignment, I noticed that the ETMX Oplev
SUM channel reported 0 counts. 
 ETMX_OLdead.png 
  14903   Fri Sep 20 12:55:02 2019 gautamUpdateCDSc1iscaux testingI was hoping that the dark / electronics
noise level on the LSC photodiodes would
be sufficient for me to test the whitening
  
  14904   Fri Sep 20 18:28:34 2019 gautamUpdateLSCY arm locking attemptI tried to lock the Y arm cavity length
to the PSL frequency using POY11_I as an
error signal. Even though I think the cavity
 POYlocking.png 
  14905   Mon Sep 23 10:49:34 2019 ranaUpdateCDSc1iscaux testing
I'd say permanently enable
AA and AI. There's no reason to turn
these off for usual channels. We can always
  
  14906   Wed Sep 25 20:10:13 2019 KojiUpdateCDSc1iscaux testing== Test Status ==
[none]
Whitening gain switching test
 testDetectMons_190925.pngtestIPPOS_190925.png 
  14907   Thu Sep 26 17:56:28 2019 KojiUpdateCDSsome rebootingYesterday (Sep 25) evening: I had to reboot
c1psl, c1iool0, and c1aux to recover nominal
IMC locking
  
  14908   Thu Sep 26 20:09:40 2019 KojiUpdateCDSc1iscaux testing== Test Status ==

[done]
Whitening gain switching test =>
 Wht1.pdfWht2.pdfWht3.pdfWht4.pdflock.png 
  14909   Fri Sep 27 15:59:53 2019 gautamUpdateCDSc1iscaux testingI reset the normalization for both arms on
Jul 9 2019.
  
  14910   Sun Sep 29 15:58:19 2019 gautamUpdateLSCPOX locking attemptSummary:

There is no visible PDH error signal
on the POX11 channels. As a result, I am
 POXlockAttempt.png 
  14911   Sun Sep 29 16:08:25 2019 gautamUpdateOptical LeversETMX Oplev HeNe replacedTo facilitate POX locking investigations,
I replaced this HeNe today with one of the
spares Chub/Steve had acquired some time
 OLRIN_20190929.pdf 
  14912   Mon Sep 30 11:20:43 2019 gautamUpdateCDSc1iscaux testing - CM board code updatedDATED, SEE   CMsoftTest.png 
  14913   Mon Sep 30 11:42:36 2019 aaronUpdateComputerscontrol rm wkstns shutdownI booted Rossa in rescue mode; though I
see no errors on bootup, I still see the
same error ("a problem has occurred")
  
  14914   Mon Sep 30 13:20:55 2019 aaronUpdateIOOshot noise measurementI wanted to measure the RF transimpedance
of the WFS heads, as outlined above.

Summary: Measurement is not done.
  
  14915   Mon Sep 30 14:16:43 2019 gautamUpdateLSCPOX PD checkout - solvedI confirmed that there is light incident
on the POX photodiode. So the problem must
lie downstream in the demod / whitening /
  
  14916   Mon Sep 30 15:51:59 2019 gautamUpdateCDSc1iscaux - some adminI did the following:


symlinked 
  
  14917   Mon Sep 30 17:04:30 2019 gautamUpdateCDSSome path changesI made some model changes to c1lsc. To
propagate the changes, I tried the usual
rtcds make sequence. But I got an error about
  
  14918   Mon Sep 30 18:20:26 2019 gautamUpdateALSALS OOL noise - a first lookAttachment #1 shows a
first look at the IR ALS noise after my re-coupling
 ALS_OOL_20190930.pdf 
  14919   Tue Oct 1 18:35:12 2019 gautamUpdateGeneralBeam centering campaign
With TRX and TRY maximized using
ASS, I centered the Oplev spots on the respective
QPDs for the four test masses and the BS.
  
  14920   Tue Oct 1 21:19:51 2019 gautamUpdateLSCPRMI locked on carrierSummary:

The
 PRMIlocked.png 
  14921   Wed Oct 2 01:11:40 2019 KojiUpdateCDSc1iscaux testingI worked on more troubleshooting
of the whitening filters Tuesday afternoon

== Test Status ==
 8x 
  14922   Wed Oct 2 10:40:07 2019 gautamUpdateCDSc1oaf model restartedThis morning, I restarted the c1oaf
model on the 
 c1oafRestart.png 
  14923   Wed Oct 2 10:50:20 2019 gautamUpdateCDSAnaconda updatedThe anaconda distribution used by the control
room workstations is actually installed on
the shared drive (/cvs/cds/ligo/apps/anaconda/)
  
  14924   Wed Oct 2 11:52:16 2019 gautamUpdateLSCPRMI Oplev loop checkoutI measured the OLTF of both the PRM Oplev
loops. Nothing odd sticks out as odd to me
in this measurement - there seems to be ~40
 PRM_OLTF.pdf 
ELOG V3.1.3-