40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 294 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  9857   Fri Apr 25 23:08:57 2014 ranaSummaryIOOMC2_TRANS QPD Servo re-re-engaged againWe turned on the MC2_TRANS paths for both
PIT/YAW tonight.
  
  9871   Mon Apr 28 20:31:38 2014 ranaSummaryIOOMC2_TRANS QPD Servo trendThis is a 4-day trend. I don't see any
difference here which is significant. My
guess is that the MC_TRANS servo gain is
 Untitled.png 
  9884   Wed Apr 30 21:16:42 2014 ranaUpdateLSCMC2 Strad   bettsreplica.jpgMC_Y_vio.pdfMC2_vio.pdf 
  9885   Wed Apr 30 21:31:25 2014 ranaHowToIOOMystery Alignment againLooks like there was some mysterious MC
alignment shift around 5:30 PM today, but
no elog.....?? Now things are drifting much
  
  9886   Wed Apr 30 21:57:07 2014 ranaSummaryIOOMC2_TRANS QPD Servo now on for real   dolphin.pngMC2_QPD_trend.png 
  9894   Thu May 1 17:00:05 2014 ranaUpdateLSCYarm locking with CM board I think that's about halfway there.
Since this needs to be a precise comparison,
we cannot use so many approximations.
  
  9896   Fri May 2 01:01:28 2014 ranaUpdateCDSc1ioo dolphin fiber nicely routedThis C1IOO business seems to be wiping
out the MC2_TRANS QPD servo settings each
day. 
  
  9897   Fri May 2 01:58:52 2014 ranaConfigurationComputer Scripts / ProgramsupdateDB configured to index NFS during CRON dailyI wanted
to use locate to find some files today, but
  
  9899   Fri May 2 03:51:29 2014 ranaUpdateLSCfarther into CMRana, Q
After some more matlab loopology
(see Qlog), we turned on the AO path successfully.
 MCkicked.png 
  9913   Tue May 6 03:17:15 2014 ranaUpdateLSCfarther into CMYes,
we still need to do these things, day team.
  
  9923   Wed May 7 17:10:59 2014 ranaUpdateCDScdsutils updated to version 226 This upgrade from Jamie has given
us the new apps (avg, servo, and trigservo).
We should figure out if there's a way to
  
  9924   Wed May 7 22:47:33 2014 ranaUpdateCDScdsutils updated to version 226: not working on pianosa or rossa controls@rossa:~ 0$ cdsutils
read C1:LSC-DARM_GAIN
Traceback (most recent call last):
  
  9929   Thu May 8 02:03:51 2014 ranaUpdateISSISS: fuse was blown, repaired, loop back onBack in November, Nic and Evan turned on
an SR560 based ISS. It uses the PMC TRANS
PD as the error signal and makes an AC coupled
 ISS.pdf 
  9934   Fri May 9 01:36:28 2014 ranaSummarySUSOptical Lever QPD Sum trends: they're almost all too weak We want there to be ~16000 cts of
signal per quadrant on the optical levers.
I think that most of the QPDs have been modified
 OLtrend.png 
  9940   Mon May 12 10:42:01 2014 ranaUpdateSUSsome Arm maintenanceI ran the ASS/ADS for the arms because
the X-arm was way out. There was also some
problem with its locking due to bad ramps
  
  9942   Mon May 12 22:42:19 2014 ranaSummarySUSOptical Lever QPD Sum trends: they're almost all too weakFor some reason or another, I decided that
we should see if the optical lever servos
were injecting too much noise into the test
 OL-FB.pngarms_140512.pdf 
  9944   Tue May 13 00:46:58 2014 ranaHowToPSLPMC relockingThe PMC runs out of range sometimes due
to the daily temperature swing. The voltage
swings up after sunset and then starts to
  
  9949   Tue May 13 17:45:21 2014 ranaUpdateCDS/frames space cleared up, daqd stabilized 
 Late last night we were getting
some problems with DAQD again. Turned out
  
  9955   Thu May 15 01:42:07 2014 ranaUpdateCDS/frames space cleared up, daqd stabilized Script seems to be working now:
nodus:~>df -h | grep
frames
  
  9960   Fri May 16 00:25:53 2014 ranaUpdatePSLPMC realign Tonight I noticed that the drop in
PMC transmission was ~1V, more than the usual
of ~0.5V from the daily drift.
  
  9969   Sun May 18 17:57:54 2014 ranaUpdateLSCETMX transients due to unseated bias cable The daytime crew had noticed that
there were some ETMX angular shifts happening
without any control or intention.
 ETMXbiasCableSeated.pdf 
  9975   Tue May 20 15:54:39 2014 ranaSummarySUSETMX oplev qpd board This QPD circuit (D980325-C1 )
uses the nice OP497 Quad FET opamp as the
transimpedance amplifier. It has a low enough
  
  10039   Sat Jun 14 18:43:15 2014 ranaUpdateIOOMC Autolocker upgrades Somehow the caget/caput commands
are really slow. I'm not sure if this is
new behavior or not, but after changing values,
  
  10043   Mon Jun 16 15:32:12 2014 ranaSummaryIOORingdown recap  
To do this better:
1) Just step the analog input
  
  10052   Tue Jun 17 19:39:29 2014 ranaUpdateComputer Scripts / Programsautolocker confusionI renamed the Autolocker and described
it in the elog from this weekend. To run
it, you have to run it from the scripts/MC/
  
  10056   Wed Jun 18 13:29:48 2014 ranaUpdateComputer Scripts / Programsautolocker confusion 
 Moral is wrong.
AutoLocker was working fine last
  
  10057   Wed Jun 18 13:39:01 2014 ranaUpdateCDScdsutils reverted to version 238 
 After some email consult with
Jamie, I got cdsutils working again by reverting
  
  10074   Thu Jun 19 16:49:15 2014 ranaUpdateComputer Scripts / Programsautolocker running again  We've noticed that the caget/caput
and cdsutils take a long time to return the
command prompt. The following two ping commands
  
  10084   Fri Jun 20 19:07:44 2014 ranaUpdateComputer Scripts / Programsop340m DNSI had forgotten to fix the DNS setup
on op340m and so our slow, perl, PID loops
for the laser were not running well (and
  
  10147   Mon Jul 7 22:07:29 2014 ranaUpdateElectronicsRF cables reroutedThis Red Ladder movement also probably
included some bumping of the MC2 stack (
 Untitled.pdf 
  10149   Mon Jul 7 23:19:55 2014 ranaUpdatePSLPMC ringdown setup

    

       
            
  
  10160   Wed Jul 9 00:59:09 2014 ranaUpdatePSLPMC local oscillator is going wonky

    

       
            
 PMC_RFslider.pdf 
  10167   Wed Jul 9 19:53:34 2014 ranaUpdatePSLPMC LO monitor trend (5 years)   LODET.png 
  10172   Thu Jul 10 01:02:13 2014 ranaUpdatePSLmore PMC scienceIncreased gain
and SNR in PMC LO monitor circuit.
 PMCloCal.pdf 
  10209   Wed Jul 16 01:18:02 2014 ranaSummaryLSCPython Wavelet peak finding for dramatic ALS - Red Resonance finding speedupNew script called scripts/ALS/findRedResonance.py
finds the IR resonance in less than 20 seconds.

    Do a ~2 FSR scan of the
 findRedResonance.pdf 
  10225   Thu Jul 17 01:24:35 2014 ranaUpdateIOOMC / EOM Stability Mystery Solved!MC loop is near
unstable. Common gain reduced. Needs more
 MC_OLG.pdf 
  10366   Mon Aug 11 23:50:38 2014 ranaConfigurationWikiDokuWikis are back up

    

       
            
  
  10375   Wed Aug 13 13:08:24 2014 ranaUpdateIMCCalculation for the input mode cleanerCan you please give us some more details
on how this design was decided upon? What
were the design considerations?
  
  10379   Wed Aug 13 22:01:57 2014 ranaUpdateIMCCalculation for the input mode cleanerNic,
Andres, and I discussed some more about the
MC WFS project today. We want
  
  10380   Wed Aug 13 23:08:17 2014 ranaUpdateIOOFSS box TFsAs EQ pointed out recently, we're injecting
into the FSS error point just after an RF
pi filter, but before the VGA. We wondered
 FSScomm.pdf 
  10381   Wed Aug 13 23:58:49 2014 ranaHowToComputer Scripts / ProgramsHP8591E spectrum analyzer remote scan

    

       
            
 HP8591E_View.pdf 
  10391   Thu Aug 14 19:23:25 2014 ranaHowToIOOHow do I set the FSS offset to make the PZT voltage start at the right place? When the IMC locks, we want the FAST
OUT of the TTFSS box to be close to zero
volts. We also want the control signal from
  
  10393   Thu Aug 14 20:52:36 2014 ranaUpdateWikiViolin Mode table added to WikiMech
Resonance Wiki
I've updated the wiki by trawling
  
  10397   Thu Aug 14 23:19:49 2014 ranaSummaryLSCETM Violin fundamental filters moved to LSC We used to do violin mode and test
mass body mode notches in the SUS-LSC filter
modules. Now we want them balanced in the
 01.png03.png 
  10421   Thu Aug 21 22:10:52 2014 ranaSummaryComputer Scripts / Programsnetwork movements To help development of the data visualization
project, we've assigned the .101 and .102
IP to DataVis. This is being used by the
  
  10438   Fri Aug 29 17:28:07 2014 ranaUpdateGreen LockinguPDH Box Checkup 
  
  10443   Wed Sep 3 00:17:22 2014 ranaUpdateGreen LockinguPDH Box CheckupWhat monitor point is being plotted here?
Or is it a scope probe output?
If this saturation is in the uPDH-X
  
  10445   Wed Sep 3 14:07:18 2014 ranaConfigurationGeneralnetgpibdata is working again now

    

       
            
  
  10455   Fri Sep 5 00:56:00 2014 ranaSummaryOptical LeversITM OLs recentered: violations foundI re-centered the ITMX & ITMY Optical
lever beams today since they were off. First
I aligned the beam into the vacuum so that
  
  10456   Fri Sep 5 03:36:00 2014 ranaUpdateComputer Scripts / Programsmartian wireless tweak I changed the Martian wireless router
to use channel 10 instead of something random
(as it was). Using the Android app 'Wifi
  
ELOG V3.1.3-