  14012   Sun Jun 24 20:02:07 2018 gautamUpdateSUSSome notes about coil driver noiseSummary:

For a series resistance of 4.5
kohm, we are suffering from the noise-gain
 CoilDriverSchematic.pdfD010001_2k_fastOnly_2.25k.pdfD010001_4k_fastOnly_4.5k.pdf 
  14013   Sun Jun 24 23:13:46 2018 johannesUpdateGeneralAUX beam alignment issuesAt some point we want to change the AUX
injection on the AS table to interfere less
with the normal interferometer path, and
 AS_AUX_SETUP.pdf 
  14016   Mon Jun 25 22:27:57 2018 shrutiUpdatePEMSeismometer temp control - heater circuitAfter removing all the clamping screws
from the heater circuit board, I soldered
the wire connecting IRF630 to the output
  
  14017   Tue Jun 26 10:06:39 2018 keerthanaUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands(Jon, Keerthana, Sandrine)

I am attaching the plots of the
Reflected and transmitted AUX beam. In the
 TRANS.pdfREFL.pdf 
  14018   Tue Jun 26 10:50:14 2018 poojaUpdateCamerasBeam spot tracking using OpenCVAim: To track the motion of beam spot in
simulated video.

I simulated a video that moves
 cv2_track_fig.pdf 
  14019   Tue Jun 26 16:28:00 2018 gautamUpdateSUSCoil driver protoboard characterizationI wanted to investigate my coil driver
noise measurement technique under more controlled
circumstances, so I spent yesterday setting
 IMG_7060.JPGETMXstitchced.pdfETMXfullSpan.pdfPSRR.pdf 
  14021   Tue Jun 26 17:54:59 2018 poojaUpdateCamerasDeveloping neural networksAim:  To find a model that trains
the simulated data of Gaussian beam spot
moving in a vertical direction by the application
 NN_noise_diag.zip 
  14022   Tue Jun 26 20:59:36 2018 aaronUpdateOMCprep for vent in a couple weeksI checked out the elog from the vent in
October 2016 when the OMC was removed from
the path. In the vent in a couple weeks,
  
  14023   Tue Jun 26 22:06:33 2018 ranaUpdateComputersrossa: SL7.3 upgrade continues: DTT is backI used the following commands to
get diaggui to run on rossa/SL7:

controls@rossa|lib64>
  
  14024   Wed Jun 27 18:12:04 2018 gautamUpdateElectronicsCoil driver dewhiteningSummary:

I've been thinking about what
we need to do to the de-whitening boards
 DeWhiteningSketch.pdf 
  14025   Wed Jun 27 19:05:20 2018 ranaUpdateComputersrossa: SL7.3 upgrade continues: DTT is backUNELOGGED: someone has changed
Pianosa from Ubuntu/Dumbian into SL7. Might
be hackers.
  
  14027   Wed Jun 27 21:18:00 2018 gautamUpdateCDSLab maintenance scripts from NODUS---->MEGATRONI moved the N2 check script and the disk
usage checking script from the (sudo) crontab
of 
  
  14028   Thu Jun 28 08:09:51 2018 SteveUpdateCDS vacuum pneumatic N2 pressureThe fardest I can go back on channel C1:
Vac_N2pres is  320 days

C1:Vac-CC1_Hornet Presuure gauge
 320d_N2.png 
  14029   Thu Jun 28 10:28:27 2018 ranaUpdateCDS vacuum pneumatic N2 pressurewe disabled logging the N2 Pressure to
a text file, since it was filling up disk
space. Now it just sends an email to our
  
  14030   Thu Jun 28 11:05:48 2018 shrutiUpdatePEMSeismometer temp control equipmentEarlier today I cleared up most of the
equipment at the X end near the seismometer
to make the area walkable. 
  
  14031   Thu Jun 28 13:12:20 2018 SteveUpdatesafetysurf safety trainingShruti and Sandrine received 40m specific
basic safety training this morning.

  
  14032   Thu Jun 28 16:48:27 2018 gautamUpdateSUSSOS cage towers For the upcoming vent, we'd like to
rotate the SOS towers to correct for the
large YAW bias voltages used for DC alignment
  
  14034   Mon Jul 2 09:01:11 2018 SteveUpdateSUSITMY_UL sensorThis bad connection is coming back




 ITMY_ULcripingback.png 
  14035   Tue Jul 3 11:59:10 2018 JonUpdateAUXAUX Carrier Scan of Y-Arm CavityI made the first successful AUX laser scan
of a 40m cavity last night.

Attachment #1 shows the measured
 yarm_carrier_trans.pdfAG4395A_02-07-2018_185504.txt 
  14036   Wed Jul 4 19:11:49 2018 JonUpdateAUXMore Testing of AUX-Laser Mode ScanningMore progress on the AUX-laser cavity scans.

Changes to the Setup


For
scans, the Agilent is now being used as a
 yarm_trans_70uW.pdfprc_trans_9mW.pdfyarm_carrier_trans_70uW.tar.gzprc_carrier_trans_9mW.tar.gz 
  14037   Wed Jul 4 20:48:32 2018 poojaUpdateCamerasMedm screen for GigE(Gautam, Pooja)

Aim: To develop medm screen for
GigE.
 sitemap.pngGigE_macros.pngCUST_CAMERA.png 
  14038   Thu Jul 5 10:15:30 2018 gautamUpdateSUSPRM watchdog trippedPRM watchdog was tripped around 7:15am
PT today morning. I restored it.
 PRM_watchdogTrip.png 
  14039   Thu Jul 5 17:33:36 2018 keerthana, sandrineUpdateelogLights not working
N/S ARM FL.
N/S ARM
INC.


These two lights inside
the 40m-lab are not working.
  
  14040   Thu Jul 5 17:58:04 2018 keerthana, sandrineUpdateelog (Analisa, Sandrine, Keerthana)

Today Annalisa helped us to understand
the new set up used to make the frequency
 setup1.jpgsetup2.jpg 
  14045   Sun Jul 8 22:27:25 2018 keerthanaUpdate AUX diagram(Analisa, Keerthana, Sandrine)

So far we tried four different
techniques to scan the AUX laser. They are,
 PLL-single_demodulation.pdfPLL-double_demodulation.pdf 
  14046   Mon Jul 9 12:36:32 2018 poojaUpdateGeneralProjector light bulb blown outProjector light bulb blown out today.   
  14048   Tue Jul 10 14:20:09 2018 steveUpdateGeneralprojector light bulb replacedBulb replaced at day 110  We have
now spare now.

 
  
  14051   Wed Jul 11 15:57:00 2018 aaronUpdateOMCReviving OMC electronicsGautam showed me the electronics racks
for the OMC PZTs and DAQ. I'm in the
process of chasing down what channels we
  
  14052   Wed Jul 11 16:23:21 2018 aaronUpdateOMCCoordination of the Output Mode-cleaner Mirror Insertion Expedition (COMMIE)I started this document on my own with
notes as I was tracing the beam path through
the output optics, as well as some notes
  
  14053   Wed Jul 11 16:50:34 2018 poojaUpdateCamerasUpdate in developing neural networksAim: To develop a neural
network that resolves mirror motion from
 graphs.pdf 
  14055   Thu Jul 12 11:13:39 2018 gautamUpdateGeneralOMC revivalAaron and I are going to do the checkout
of the OMC electronics outside vacuum today.
At some point, we will also want to run a
  
  14056   Thu Jul 12 12:26:39 2018 aaronUpdateGeneralOMC revivalWe found a diagram describing the DC Readout
wiring
scheme on the wiki page for DC
  
  14057   Thu Jul 12 14:06:39 2018 keerthanaUpdateelogFinesse and Analytical solution - ComparisonI tried to compare the cavity scan data
we get from the Finesse simulation and that
we expect from the Analytical solution. The
 finesse_cavity.pngAnalytical1.pdfFinesse_Analytical.pdfDifference.pdf 
  14058   Thu Jul 12 15:15:47 2018 SandrineUpdate Beat Note Measurements for Cavity Scans(Gautam, Sandrine)

We calculated the expected power
of the beat note for Annalisa's Y arm
  
  14059   Thu Jul 12 16:18:22 2018 SteveUpdateVACVent preparationsWe are getting ready to vent.

 
 before_Vent.pngbefore_Vent_cond.png 
  14060   Thu Jul 12 21:16:25 2018 aaronUpdateOMCChecking OMC ElectronicsIn preparation for tomorrow's vent,
I'm checking some of the OMC-related
electronics we plan to use.
  
  14061   Thu Jul 12 23:59:14 2018 gautamUpdateGeneralVent objectives and prepVent
objectives:
  
  14063   Fri Jul 13 02:52:11 2018 gautamUpdateGeneralVent objectives and prep[KA,
GV]
 preVentStatus.png 
  14064   Fri Jul 13 10:54:55 2018 aaronUpdateVACVent 80[aaron, steve]

Steve gave me a venting tutorial.
I'll record this in probably a bit more
 vent80wtiptilts.png 
  14066   Fri Jul 13 16:26:52 2018 SteveUpdateVACVent 80 is completing...Steve and Aaron,

6 hrs vent is reaching equlibrium
to room air. It took 3 and a half instrument
 @atm.pngvent80_7h.pngventregN2&Air_c.jpg 
  14067   Fri Jul 13 17:13:45 2018 KojiUpdateGeneralVent objectives and prepNotice:
I removed these 75Ohm video cables.
 P_20180713_020603.jpg 
  14068   Fri Jul 13 18:01:13 2018 gautamUpdateGeneralLow power MCAfter getting the go ahead from Steve,
I removed the physical beam block on the
PSL table, sent the beam into the IFO, and
  
  14070   Fri Jul 13 23:23:49 2018 poojaUpdateCamerasUpdate in developing neural networksAim: To develop a neural
network that resolves mirror motion from
 nn_simulation_2_nodes4_lr0p00001_beta1_0p8_beta2_0p85.pdfnn_simulation_2_nodes8_lr0p00001_beta1_0p8_beta2_0p85.pdf 
  14072   Sat Jul 14 16:04:34 2018 aaronUpdateOMCChecking OMC ElectronicsNext check is the DCPD/OMMT Satellite
Box

I traced a cable from the
OMC electrical feedthrough flanges to find
 Screenshot_2018-07-14_17.53.40.pngScreenshot_2018-07-14_17.57.17.png 
  14074   Mon Jul 16 18:12:00 2018 KojiUpdateVACAdding a manual gate valve between TP1 and V1/VM2[Steve Koji]

We are in the process of adding
a manual gate valve between TP1 (Osaka Maglev)
 P_20180716_155413.jpgP_20180716_155645.jpgP_20180716_155738.jpgP_20180716_162307.jpgP_20180716_172000.jpg 
  14075   Tue Jul 17 01:07:40 2018 gautamUpdateSUSETMY EQ stopsFor the heater setup on EY table, I EQ-stopped
ETMY. Only
  
  14076   Tue Jul 17 12:46:28 2018 ranaUpdateGeneralsome notes from yesterdayFor the EY, instead of balancing the table,
I just moved the weight approximately so
that the ETMY OSEMS were at half light, but
  
  14081   Wed Jul 18 03:14:48 2018 AnnalisaUpdateGeneralVent 80 recovery[Gautam, Johannes, Koji, Annalisa]

Tonight we increased the power
of the PSL laser and we achieved the lock
  
  14084   Wed Jul 18 23:43:50 2018 KojiUpdateGeneralVent 80 recoveryIs the reflector too close to the beam
and causing clipping?

 IMG_5868.JPGIMG_5382.JPG 
  14089   Thu Jul 19 18:09:17 2018 poojaUpdateCamerasUpdate in developing neural networksAim: To develop a neural
network that resolves mirror motion from
 nn_simulation_mlt_sine_nodes4_lr0p00001_beta1_0p8_beta2_0p85_marked.pdfnn_simulation_2_nodes4_target-1to1_marked.pdf 
ELOG V3.1.3-