40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 291 of 341  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  13958   Wed Jun 13 23:23:44 2018 johannesUpdateCDSEX wiring confusionIt's true.

I went through the wiring of the
c1auxex crate today to disentangle the pin
 c1auxex_channels.pdfXEND_slow_wiring.pdf 
  13959   Thu Jun 14 00:40:42 2018 gautamUpdateLSCPRCL loop shape anomalydon't use IN_1/IN_2: recall pizza meeting
from a few weeks back: use IN1/EXC + Al-Gebra

  
  13960   Thu Jun 14 00:46:09 2018 ranaUpdateIOOWFS HEAD SW confusionits painful, but you and I should probably
take these out, bypass the switches
and use them with fixed gain;
  
  13961   Thu Jun 14 10:41:00 2018 gautamUpdateCDSEX wiring confusionDo we really have 2 free ADC channels at
EX now? I was under the impression we had
ZERO free, which is why we wanted to put
  
  13962   Thu Jun 14 13:29:51 2018 gautamUpdateGeneralPSL shutter closed, all optics misaligned[jon, gautam]

Jon is doing some characterization
of the AUX laser setup for which he wanted
  
  13963   Thu Jun 14 15:21:58 2018 gautamUpdateComputer Scripts / Programs/cvs/cds Backup in dangerI think this is because /cvs/cds is getting
too big. lsblk reveals:

  
  13964   Thu Jun 14 15:24:32 2018 SteveUpdatePEM ADC DAC In Line Test Boards are inWe have 6 of these boards now in cabinet
E7

 ADC_DAC_in_(1).JPG 
  13965   Thu Jun 14 15:31:18 2018 johannesUpdateCDSEX wiring confusionBad wording, sorry. Should have been channels
in excess of ETMX controls. I'll add
the others to the list as well.
 XEND_slow_wiring.pdfc1auxex_channels.pdf 
  13966   Thu Jun 14 18:09:24 2018 gautamUpdateLSCReliable and repeatable 1f DRMI lockingI finally analyzed the sensing measurement
I ran on Tuesday evening. Sensing responses
for the DRMI DOFs seems consistent with what
 DRMI1f_June14.pdf 
  13967   Thu Jun 14 19:30:12 2018 gautamUpdateGeneralIFO alignment restoredAll optics have been re-aligned. Jon/Johannes
will elog about the work today.
  
  13968   Thu Jun 14 22:45:05 2018 johannesUpdateGeneralAUX beam SRC alignment[Jon, Gautam, Johannes]

Jon spent some time trying to align
the AUX beam to the SRC today, I got to the
  
  13969   Fri Jun 15 00:53:21 2018 gautamUpdateLSCCalibrated MICH spectrumUsing the numbers from the sensing measurement,
I calibrated the measured in-loop MICH spectrum
from Tuesday night into free-running displacement
 C1NB_disp_40m_MICH_NB_2018-06-14.pdf 
  13971   Fri Jun 15 09:14:42 2018 SteveUpdateGeneralOplev sumsOplev sums of 240 days.




 opSums.png 
  13972   Fri Jun 15 09:51:55 2018 poojaUpdateCamerasDeveloping neural networkAim : To develop a neural network on simulated
data.

I developed a python code that
 nn_1.pdfnn_2.pdf 
  13973   Fri Jun 15 14:22:05 2018 gautamUpdateALSBeatMouth PDFR measurementI did the measurement with the BeatMouth
open today. Main changes:


Directly pipe the RF output
 BeatMouthPDFR.pdfBeatMouth_PDFRdata.tgz 
  13974   Sat Jun 16 00:26:48 2018 gautamUpdateGeneralPRC modescan attempt[Jon, Gautam, Johannes]

We did the following today:


Dither align arms such
  
  13975   Sat Jun 16 01:25:29 2018 KojiUpdateGeneralPRC modescan attemptThe PRC FSR is, of course, very close to
twice of our f1 moudlation frequency (11MHz
x 2 = 22MHz) .
  
  13976   Sat Jun 16 20:57:59 2018 JonUpdateGeneralPRC modescan attemptHere's a Finesse modeling of what
we're expecting to observe with this
test. It uses Gautam's base
 40M_SRMI_AM_annotated.pdf40M_DRMI_AM.pdf 
  13977   Sun Jun 17 14:20:35 2018 KojiUpdateGeneralChiara new USB 4TB DIskI have connected a 4TB disk to chiara via
a USB-SATA adapter. This disk has been recognized
as /dev/sde. A GUID Partition Table (GPT),
  
  13978   Mon Jun 18 10:34:45 2018 johannesUpdateComputer Scripts / Programsrunning comsol job on optimusI'm running a comsol job on optimus
in a tmux session named cryocavs. Should
be done in less than 24 hours, judging by
  
  13980   Mon Jun 18 12:07:03 2018 KojiUpdateGeneralChiara new USB 4TB DIskThe initial local backup with rsync was
done. Now
the new 4TB disk is (supposed to be) automatically
  
  13981   Mon Jun 18 14:32:42 2018 gautamUpdatePSLOptics on AS tableYesterday, I moved the following optics:


Lens in front of AS110
PD.
BS splitting light between
  
  13982   Mon Jun 18 15:59:17 2018 johannesUpdatePSLOptics on AS table


Quote:


  
  13983   Mon Jun 18 16:57:54 2018 KojiUpdatePSLOptics on AS tableOf course, many (but no all) of the optics
were custom-ordered back in ~2000.
  
  13984   Mon Jun 18 19:47:02 2018 gautamUpdateGeneralMICH actuator calibrationSummary:

The actuator (pendulum) gains for
the Beam Splitter and the two ITMs were measured
 AS55cal_process.pdfAS55cal.pdfMICH_act_calib.pdf 
  13985   Tue Jun 19 00:19:00 2018 gautamUpdateASCPOP status checkMotivation:


I want to use the QPD at
POP, calibrate it into physical units, and
  
  13986   Tue Jun 19 14:08:37 2018 poojaUpdateCamerasCCD calibration using LED1050EAim: To measure the optical power from
led using a powermeter.

Yesterday Gautam drilled a larger
  
  13987   Tue Jun 19 18:56:55 2018 JonUpdateGeneralAUX beam alignment issuesNot much progress today with the AUX cavity
scans. I've determined there still are
some alignment issues.
  
  13988   Tue Jun 19 23:27:27 2018 gautamUpdateSUSETMX coil driver work in AM tomorrowPer discussion today eve, barring objections,   
  13989   Wed Jun 20 00:57:04 2018 johannesUpdateGeneralAUX beam alignment issuesWe did swap a lens as discussed in elog 13968,
but they both had f=100mm specified, the
difference being one was AR-coated for 1064
 as110_rf_30MHz.pdfyend_rf_30MHz.pdf 
  13990   Wed Jun 20 09:16:56 2018 SteveUpdatePEMdusty labYou should wipe off the table cover before
you take it off next time.

It is important to turn up the
 AP.JPGITMY.JPGITMX.JPGSP.JPG 
  13991   Wed Jun 20 20:39:36 2018 poojaUpdateCamerasCCD calibration using LED1050E 




  
  13992   Thu Jun 21 00:14:01 2018 gautamUpdateSUSETMX coil driver outI finished the re-soldering work today,
and have measured the coil driver noise pre-Mods
and post-Mods. Analysis tomorrow. I am holding
  
  13993   Thu Jun 21 03:13:37 2018 gautamUpdateSUSETMX coil driver noiseI decided to take a quick look at the data.
Changes made to the ETMX coil driver board:


Fast path series resistances:
 ETMXsticthced.pdfETMXFullSpan.pdfETMXCoilDriver.fil.zip 
  13994   Thu Jun 21 09:33:02 2018 JonUpdate AUX Mode Scans of YARM, PRC cavities[Jon, Keerthana, Sandrina]

Yesterday we carried out preliminary
proof-of-concept measurements using
 YARM_AUX_RF-offset_scan.pdftemp_broadband_refl33.pdf 
  13995   Thu Jun 21 13:24:00 2018 keerthanaUpdateelogThe cavity scan data of June 20(Jon, Keerthana, Sandrine)

We tried to align the AUX and PSL
laser yesterday. We collected the data from
 AS110_Beat.pdfYEND_Beat.pdf 
  13998   Thu Jun 21 15:32:05 2018 gautamUpdateElectronicsEX AA filter range change[steve, gautam]

I took this opportunity of EX downtime
to change the supply voltage for the AA unit
  
  13999   Thu Jun 21 18:25:57 2018 gautamUpdateSUSETMX coil driver re-installedInitial tests look promising. Local damping
works and I
even locked the X arm using POX,
  
  14000   Thu Jun 21 22:13:12 2018 gautamUpdateCDSpianosa upgradepianosa   
  14001   Thu Jun 21 23:59:12 2018 shrutiUpdatePEMSeismometer temp controlWe (Rana and I) are re-assembling the temperature
controls on the seismometer to attempt PID
control and then improve it using reinforcement
  
  14002   Fri Jun 22 00:06:13 2018 shrutiUpdateGeneralover-head fluorescent lights downTwo out of the four over-head fluorescent
lights in the X end of the interferometer
were flickering today.
  
  14003   Fri Jun 22 00:59:43 2018 gautamUpdateCDSpianosa functional, but NO DTTMEDM, EPICS and dataviewer seem to work,
but diaggui still doesn't work (it doesn't
work on Rossa either, same problem as reported
  
  14004   Fri Jun 22 08:50:33 2018 SteveUpdateSUSITMY_UL sensorWe may lost the UL magnet or LED  ITMY_UL.png 
  14005   Fri Jun 22 10:42:52 2018 poojaUpdate Developing neural networksAim: To find a model that trains the simulated
data of Gaussian beam spot moving in a vertical
direction by the application of a sinusoidal
 NN_fig.zip 
  14006   Fri Jun 22 14:18:04 2018 SteveUpdatePSLOptics on AS table 




  
  14007   Fri Jun 22 15:13:47 2018 gautamUpdateCDSDTT workingSeems like DTT also works now. The trick
seems to be to run 
 Screenshot_from_2018-06-22_15-12-37.png 
  14008   Fri Jun 22 15:22:39 2018 sudoUpdateCDSDTT working


Quote:


  
  14009   Fri Jun 22 18:30:21 2018 gautamUpdateSUSITMY_UL sensorI think if the magnet fell off, we would
see high DC signal, and not 0 as we do now.
I suspect satellite box or PD readout board/cabling.
  
  14010   Sat Jun 23 13:08:41 2018 JonUpdateAUXFirst Coherent AUX Scan of PRC Using AM Sidebands[Jon, Keerthana, Sandrine]

Thu.-Fri. we continued with PRC
scans using the AUX laser, but now the "scanned"
 IMG_2695.jpegIMG_2698.jpegIMG_2699.jpeg 
  14011   Sat Jun 23 20:54:35 2018 KojiUpdateAUXFirst Coherent AUX Scan of PRC Using AM SidebandsHow much was the osc freq of the marconi?
And then how much was the resulting freq
offset between PSL and AUX?
  
ELOG V3.1.3-