  6589   Mon Apr 30 22:41:34 2012 JenneUpdateSUSETMY oplev power supply dead

    

       
            
  
  6600   Thu May 3 21:13:48 2012 KojiSummarySUSITMX/PRM/BS OPLEV aligned[Jenne/Den/Koji]
We locked Xarm/Yarm and manually
alignmed ITMX/ITMY/BS/ETMX/ETMY/PZT1/PZT2.
  
  6617   Mon May 7 21:19:00 2012 JenneUpdateSUSETMX oplevI'm still not super happy with the low
power level of the ETMX oplev, so I went
to investigate.
 OpLevETMX_1100days.png 
  6620   Tue May 8 03:33:24 2012 JenneUpdateSUSNew misalign / restore scripts for IFO_ALIGN screenSince Den wasn't able to fix c1sus (make
it talk to the framebuilder) before he left
a few hours ago, I decided to do some housekeeping
  
  6643   Mon May 14 08:49:47 2012 steveUpdateSUSETMY damping restoredETMY sus damping restored.   
  6644   Tue May 15 08:44:55 2012 steveUpdateSUSETMX damping restoredETMX sus damping restored  ETMX_ETMYvar.png 
  6647   Wed May 16 14:06:49 2012 steveUpdateSUSTemperature rulesGuralp 1  is on the south side of
IOO chamber
 temprules.png 
  6649   Fri May 18 11:19:17 2012 steveUpdateSUSETMY oplev laser is dead 
 The typical sign of a dying
gas laser is that it glows for a few minutes
  
  6650   Fri May 18 15:25:15 2012 steveUpdateSUSAR coated lens swapped in at ETMX oplev

    

       
            
 ETMXoplevlensAR.png 
  6656   Tue May 22 08:03:01 2012 steveUpdateSUSETMY oplev gets new laser

    

       
            
  
  6680   Fri May 25 02:56:44 2012 DenUpdateSUSMC3 local dampingI've terminated input to AA filters and
measured signal to coils C1:SUS-MC3_??COIL_OUT.
 DSC_4305.JPGosem_noise.pngosem_coil.png 
  6681   Fri May 25 13:24:48 2012 DenUpdateSUSMC3AA IN -> COIL DRIVER IN transfer function
for MC3
 freq_resp.pngtest_dig.png 
  6706   Tue May 29 15:55:22 2012 steveUpdateSUSETMY oplev spot size reduced

    

       
            
 ETMYoplev.jpgIMG_1243.JPG 
  6710   Tue May 29 21:34:08 2012 JenneUpdateSUSETMY oplev spot size reduced

    

       
            
  
  6743   Fri Jun 1 14:56:08 2012 JamieUpdateSUSOplevs all different, messed upFor some reason the state of the oplevs
is completely different for almost every
suspension.  They have different sets
 oplevs.png 
  6744   Fri Jun 1 18:07:32 2012 steveUpdateSUSOplevs servo values

    

       
            
  
  6745   Fri Jun 1 19:48:54 2012 ranaUpdateSUSOplevs all different, messed up 
 Its a good question, but the
answer is yes. At some level all of the OL
  
  6752   Tue Jun 5 09:32:12 2012 steveUpdateSUSPRM oscillation What not to do:
The PRM oplev servo was left on and
it was driving this oscillation overnight.
 PRMosc.png 
  6764   Wed Jun 6 09:27:09 2012 steveUpdateSUSPRM damping restored

    

       
            
 PRMwhat.png 
  6766   Wed Jun 6 14:36:58 2012 steveUpdateSUSETMY oplev work finished

    

       
            
  
  6781   Thu Jun 7 08:12:20 2012 steveUpdateSUSPRM is still oscillating

    

       
            
 PRMoscil.png 
  6785   Thu Jun 7 13:18:42 2012 ranaUpdateSUSPRM is still oscillating  Set the PRM OL servo gains
to zero until someone can take care of this.
Turning off the buttons doesn't help anything
  
  6786   Thu Jun 7 13:25:37 2012 KojiUpdateSUSPRM is still oscillatingDone.
C1:SUS-PRM_OLPIT_GAIN 1.0 -> 0
C1:SUS-PRM_OLYAW_GAIN -0.7 -> 0
  
  6788   Thu Jun 7 18:46:13 2012 yutaUpdateSUSPRM oplev centeredPRM oplev beam was not hitting on the QPD
since Jun 1, so I centered it. I reverted
the oplev servo gains and now oplev servo
  
  6799   Tue Jun 12 02:07:42 2012 JenneUpdateSUSPRM oplevs left offYuta claims he fixed the PRM oplev by centering
it the other day, but no one has left it
on and watched it for a long while, to make
  
  6804   Tue Jun 12 16:33:32 2012 steveUpdateSUSPRM oplevs servo ON for confirmation


   
        
            
  
  6805   Tue Jun 12 17:04:55 2012 steveUpdateSUSPRM oplevs servo is still bad


   
        
            
 PRMolvstillosc.png 
  6814   Wed Jun 13 11:19:05 2012 steveUpdateSUSIDC receptacles clampedThe MC_ IDC 64 pin cables from sat. amplifiers
to junction-interface-board towards 
whitening - dewhitening at the back of rack
 IMG_1341.JPG 
  6952   Tue Jul 10 17:47:55 2012 yutaUpdateSUSPRM oplevs fixedI centetered PRM oplev, lowered gain and
PRM oplev servo is not oscillating any more.
It is OK for more than a softball
 PRMoplevpitOLTF.pngPRMoplevyawOLTF.pngPRMOplevSpectra20120710.png 
  6960   Wed Jul 11 13:36:58 2012 yutaUpdateSUSOSEM and oplev spectra of opticsBelow is angular spectra of every suspended
core optics.
As you can see, there's a peak at
 OLPITYAW.pngSUSPITYAW.png 
  6964   Wed Jul 11 16:19:08 2012 yutaUpdateSUSoplev servo phiologyI heard that Steve did great work on oplev
in Feb 2012.
Here's summary what happened to oplev
  
  6965   Thu Jul 12 02:12:42 2012 yutaUpdateSUSBS 3.3 Hz motionI tried to reduce BS 3.3 Hz motion with
local damping. 3.3 Hz probably comes from
the stack, but I want to reduce this because
 BSdam.pngBSOLSUSresonantgain.png 
  6967   Thu Jul 12 13:27:16 2012 yutaUpdateSUSmeasured OLTFs of PRMI optics' SUSPOSI measured openloop transfer functions
of PRM/BS/ITMX/ITMY SUSPOS servo.
They look great. They all have ~50
 PRMSUSPOSOLTF.pngBSSUSPOSOLTF.pngITMXSUSPOSOLTF.pngITMYSUSPOSOLTF.png 
  6968   Thu Jul 12 15:25:24 2012 JenneUpdateSUSClearing test pointsSomehow we got an excitation going on BS
OpLevs, and even though Yuta thought he might
have accidentally started it, he couldn't
  
  7005   Mon Jul 23 18:16:13 2012 JamieUpdateSUSDQ block added to sus_single_control library partsI have added a DQ block to the sus_single_control
library part.  This means that all sus
models will automatically generate DQ channels
  
  7071   Wed Aug 1 16:38:46 2012 steveUpdateSUSspare SRMU 03 optic movedSOS optics prepared to be hanged are moved
from the South Flow Bench to S15 Clean Cabinet.
SRMU 03 (1-25-2010) specification
 IMG_1464.JPGIMG_1465.JPGIMG_1466.JPG 
  7072   Wed Aug 1 17:04:22 2012 JenneUpdateSUSspare SRMU 03 optic moved

    

       
            
  
  7087   Mon Aug 6 07:59:33 2012 steveUpdateSUSPRM oplevs servo is still bad

    

       
            
 PRMeq.png 
  7091   Mon Aug 6 16:48:43 2012 steveUpdateSUSSRM oplev is clippingThe SRM oplev beam is clipping.   
  7098   Mon Aug 6 23:05:22 2012 JenneUpdateSUSPRM oplevs servo is fineThe PRM was pointing totally the wrong
way, so there was no light on the oplev PD. 
I restored the PRM, turned the gains back
  
  7106   Tue Aug 7 16:11:23 2012 steveUpdateSUSoptical table box wall proposal Sanwiched wall as shown: 1"
clear acrylic, 2 layers of 0.004" thick
"window tint", 1 layer of 
 IMG_1479.JPGIMG_1478.JPG 
  7107   Tue Aug 7 16:21:16 2012 ranaUpdateSUSoptical table box wall proposal

    

       
            
  
  7167   Mon Aug 13 23:06:08 2012 JenneUpdateSUSSimplant left onSimplant for ETMX was left on, so I didn't
have control of ETMX.  Not cool. 
  
  7233   Mon Aug 20 11:36:44 2012 SteveUpdateSUSETMX is not happyETMX has some periodic oscillation. It's
damping was found tripped this morning. 
  
  7235   Mon Aug 20 13:10:31 2012 jamie, jenneUpdateSUSETMX is not happy

    

       
            
  
  7242   Tue Aug 21 09:14:01 2012 SteveUpdateSUSoplevs centeredOplevs centered in flashing condition,
except PRM and SRM.  IP POS centered
also,
 OPLcentered.png 
  7282   Mon Aug 27 09:24:17 2012 SteveUpdateSUSEQ damage  It looks like we may lost 1 (or
3 )  magnets? Do not panic, it's not
for sure
 eqDamage.png 
  7283   Mon Aug 27 10:49:03 2012 KojiUpdateSUSEQ damageAfter shaking ITMX by the alignment bias
in yaw, it came back.
As ETMX seems to be largely misaligned
  
  7286   Mon Aug 27 15:49:46 2012 JenneUpdateSUSEQ damage

    

       
            
  
  7309   Wed Aug 29 17:09:57 2012 jamieUpdateSUSETMX OK, free swingingETMX appears to be fine.  It was stuck
to its OSEMs in the usual way.  I touched
it and it dislodged and is now swinging freely. 
 Screenshot.png 