  1785   Fri Jul 24 11:04:11 2009 AlbertoConfigurationComputerselog restarted

This morning I found the elog down. I restarted it using the procedure in the wiki.

  1809   Wed Jul 29 19:31:17 2009 ranaConfigurationComputerselog restarted

Just now found it dead. Restarted it. Is our elog backed up in the daily backups?

  1893   Wed Aug 12 15:02:33 2009 AlbertoConfigurationComputerselog restarted

In the last hour or so the elog crashed. I  have restarted it.

  1944   Tue Aug 25 21:26:12 2009 AlbertoUpdateComputerselog restarted

I just found the elog down and I restarted it.

  2106   Fri Oct 16 16:44:39 2009 Alberto, SanjitUpdateComputerselog restarted

This afternoon the elog crashed. We just restarted it.

  2567   Wed Feb 3 10:46:12 2010 AlbertoUpdateelogelog restarted

 Again, this morning Zach told me that the elog had crashed while he was trying to post an entry.

I just restarted it.

  2569   Thu Feb 4 00:59:52 2010 ranaUpdateelogelog restarted

 I restarted the ELOG on NODUS just now. Our attempt to set up error logging worked - it turns out ELOG was choking on the .ps file attachment.

So for the near future: NO MORE .PS files! Use PDF - move into the 20th century at least.

matlab can directly make either PNG or PDF files for you, you can also use various other conversion tools on the web.

Of course, it would be nice if nodus could handle .ps, but its a Solaris machine and I don't feel like debugging this. Eventually, we'll give him away and make the new nodus a Linux box, but that day is not today.

  2669   Fri Mar 12 13:52:18 2010 ZachUpdateelogelog restarted

 The elog was down and I ran the restart script.

  2758   Fri Apr 2 08:52:21 2010 AlbertoUpdateelogelog restarted

i just restarted the elog for the third time in the past 12 hours.

I checked the elog.log file to debug the problem. It doesn't contain eveidence of any particular cause, except for png/jpg file uploads happened last night.

I'm not sure we can blame Image Magic again because the last crash seems to be occurred just after an entry with e jpg picture was included in the body of the message. I think Image Magic is used only for previews of attachments like pdfs or ps.

Maybe we should totally disable image magic.

  2792   Mon Apr 12 17:48:32 2010 AidanUpdateComputer Scripts / Programselog restarted

 The elog crashed when I was uploading a photo just now. I logged into nodus and restarted it.

  2817   Tue Apr 20 13:00:52 2010 ZachUpdateelogelog restarted

 I restarted the elog with the restart script as it was down.

  2853   Wed Apr 28 08:55:19 2010 ZachUpdateelogelog restarted

 Restarted the elog with the script as it was down.

  2854   Wed Apr 28 09:21:16 2010 ZachUpdateelogelog restarted

And again.

Quote:

 Restarted the elog with the script as it was down.

 

  3390   Tue Aug 10 01:05:17 2010 ZachUpdateelogelog restarted

 Elog was down. Restarted with the script.

  3396   Wed Aug 11 02:44:37 2010 ZachUpdateelogelog restarted

You'll never guess what happened: the elog crashed!

I restarted it with the script. Yay.

  3401   Wed Aug 11 16:13:59 2010 JennaUpdateelogelog restarted

The elog crashed, so we restarted it again.

  3406   Thu Aug 12 11:39:27 2010 ZachUpdateelogelog restarted

with script

  3533   Tue Sep 7 14:42:02 2010 DmassConfigurationelogelog restarted

elog crashed on an upload. restarted and it worked fine with the same file.

  3537   Tue Sep 7 22:21:17 2010 AlbertoConfigurationComputerselog restarted
  3538   Tue Sep 7 22:21:47 2010 DmassConfigurationelogelog restarted

Quote:

elog crashed on an upload. restarted and it worked fine with the same file.

 Again. Resubmitted an old entry with just text changes. Elog hung for 5 min +.

  3567   Mon Sep 13 12:09:42 2010 kiwamuSummaryGeneralelog restarted

 Elog didn't respond, so I restarted it with the script.

Before killing the process somehow two elog daemons were running at the same time. I killed those two manually. 

  3613   Mon Sep 27 21:57:59 2010 ZachUpdateelogelog restarted

 took two runs of the script as usual

  4017   Mon Dec 6 22:43:19 2010 FrankConfigurationelogelog restarted

I restarted the elog because i changed the configuration for the cryo-elog.

Used the "start-elog.csh" script in /cvs/cds/caltech/elog/

  5348   Tue Sep 6 21:00:48 2011 ZachUpdateelogelog restarted

I restarted the elog with the script as it was not up when I tried to make a post. It was again unresponsive when I went to submit, but this time the script couldn't restart it. The log said it couldn't bind to 8080, which usually happens if the daemon is still running. I pkilled it, then reran the script, and it appears to be working.

  10817   Fri Dec 19 14:25:48 2014 diegoUpdateComputer Scripts / Programselog restarted

elog was not responding for unknown reasons, since the elogd process on nodus was alive; anyway, I restarted it. 

  3993   Tue Nov 30 11:44:36 2010 ZachUpdateelogelog restarted -- SCRIPT adapted for 2.8.0

 I have created an updated version of the "start-elog-nodus" script and put it in .../elog/elog-2.8.0. It seems to work fine.

  3382   Sat Aug 7 10:47:38 2010 KojiSummaryelogelog restarted / source of the trouble eliminated

Nancy notified me that the elog crashed. It was fixed.


I restarted elog, but it kept crashing. Some of the entries on Aug 6th caused the trouble.

I tried to refresh the pictures in entries 3376, 3377, 3378. Still it kept crashing.
I started to dig into the elog file itself. (/cvs/cds/caltech/elog/elog-2.7.5/logbooks/40m/100806a.log)

FInally I found that there was some invalid reply links in the entry 3379.

Date: Fri, 06 Aug 2010 19:29:59 -0700
Reply to: 3379
In reply to: 3379

The entry is refering this entry itself. That is weird. So I deleted the reply-to and in-reply-to lines.
Then elogd got happy.

In fact, 3379 was a dupulication of 3380, so I deleted this entry.

  4438   Thu Mar 24 13:56:05 2011 josephbUpdateelogelog restarted at 1:55pm

Restarted elog.

  16041   Fri Apr 16 11:31:00 2021 ranaUpdateelogelog stuck ~10 AM today

found it unresponsive. Restarted fine using procedure documented in wiki

  5750   Fri Oct 28 02:41:18 2011 SureshMetaphysicselogelog unresponsive: restarted

Elog did not respond despite running the /cvs/cds/caltech/elog/start-elog.csh  script two times.  

It worked the after the third restart. 
 

  7136   Thu Aug 9 12:55:15 2012 ZachUpdateelogelog was being a pain in the ass; I restarted it

The elog was not responding. I attempted to restart it by running .../start-elog.csh, but this didn't work (even after the usual ~2 times it needs).

Somehow pkill did not kill the daemon, so I kill -9'd it and that did the trick. I ran the start script once more and it came back online.

  3429   Tue Aug 17 09:06:08 2010 AlbertoUpdateelogelog was down

I just restarted the elog after I found it down a few minutes ago.

  7757   Wed Nov 28 17:40:28 2012 jamieOmnistructureComputerselog working again on firefox 17

Koji and I figured out what the problem is.  Apparently firefox 17.0 (specifically it's user-agent string) breaks fckeditor, which is the javascript toolbox the elog uses for the wysiwyg text editor.  See https://support.mozilla.org/en-US/questions/942438.

The suspect line was in elog/fckeditor/editor/js/fckeditorcode_gecko.js.  I hacked it up so that it stopped whatever crappy conditional user agent crap it was doing.  It seems to be working now.

Edit by Koji: In order to make this change work, I needed to clear the cache of firefox from Tool/Clear Recent History menu.

  510   Sun Jun 1 19:39:35 2008 tobinConfigurationComputerselog, etc
Phil Ehrens gave me a DVD of the 40m elog, apache, and (Jamie's) SVN archive.
I copied it to nodus:/home/controls/dvd-from-ehrens.  Once we get the elog
running on nodus, we can copy the datafile over again from dziban (so that
we don't lose any elog entries) and switch over.
  3475   Fri Aug 27 07:21:13 2010 AlastairUpdateGeneralelog...

 was down.  I restarted the version in the 2.7.5 folder.  It went down again almost immediately but stayed up after the second restart.

  12049   Sat Mar 26 18:28:24 2016 KojiUpdateelogelogd flakiness

Elogd have been restarted several times today because it died everytime I submit something.
Here is the copy of the log.


GET /OMC_Lab/255?cmd=loc&value=Submit HTTP/1.1
Returned 6 bytes
GET /40m/elog.rdf HTTP/1.1
Returned 17109 bytes
TCP connection #1 on socket 5 closed
POST /OMC_Lab/ HTTP/1.1
Returned 20 bytes
GET /OMC_Lab/255 HTTP/1.1
Returned 53721 bytes
GET /ckeditor/skins/moono/images/arrow.png HTTP/1.1
Returned 489 bytes
POST /OMC_Lab/ HTTP/1.1
*** buffer overflow detected ***: /export/home/elog/elog/elogd terminated
======= Backtrace: =========
/lib/x86_64-linux-gnu/libc.so.6(__fortify_fail+0x37)[0x7f1435639e57]
/lib/x86_64-linux-gnu/libc.so.6(+0x108d50)[0x7f1435638d50]
/lib/x86_64-linux-gnu/libc.so.6(+0x1081b9)[0x7f14356381b9]
/lib/x86_64-linux-gnu/libc.so.6(_IO_default_xsputn+0xdd)[0x7f14355ab0cd]
/lib/x86_64-linux-gnu/libc.so.6(_IO_vfprintf+0x25a8)[0x7f143557ac18]
/lib/x86_64-linux-gnu/libc.so.6(__vsprintf_chk+0x94)[0x7f1435638254]
/lib/x86_64-linux-gnu/libc.so.6(__sprintf_chk+0x7d)[0x7f143563819d]
/export/home/elog/elog/elogd[0x426405]
/export/home/elog/elog/elogd[0x473b7f]
/export/home/elog/elog/elogd[0x4abfb2]
/export/home/elog/elog/elogd[0x4ad7fb]
/export/home/elog/elog/elogd[0x4b0af5]
/export/home/elog/elog/elogd[0x4b1eb9]
/export/home/elog/elog/elogd[0x403568]
/lib/x86_64-linux-gnu/libc.so.6(__libc_start_main+0xed)[0x7f143555176d]
/export/home/elog/elog/elogd[0x404299]
======= Memory map: ========
00400000-004e6000 r-xp 00000000 fc:00 10361276                           /export/home/elog/elog-3.0.d/elogd
006e5000-006e6000 r--p 000e5000 fc:00 10361276                           /export/home/elog/elog-3.0.d/elogd
006e6000-007c6000 rw-p 000e6000 fc:00 10361276                           /export/home/elog/elog-3.0.d/elogd
007c6000-0173d000 rw-p 00000000 00:00 0
0214d000-02656000 rw-p 00000000 00:00 0                                  [heap]
7f14342f8000-7f143430d000 r-xp 00000000 fc:00 2883628                    /lib/x86_64-linux-gnu/libgcc_s.so.1
7f143430d000-7f143450c000 ---p 00015000 fc:00 2883628                    /lib/x86_64-linux-gnu/libgcc_s.so.1
7f143450c000-7f143450d000 r--p 00014000 fc:00 2883628                    /lib/x86_64-linux-gnu/libgcc_s.so.1
7f143450d000-7f143450e000 rw-p 00015000 fc:00 2883628                    /lib/x86_64-linux-gnu/libgcc_s.so.1
7f143450e000-7f14348cd000 rw-p 00000000 00:00 0
7f1434a34000-7f1434d39000 r--p 00000000 fc:00 530477                     /usr/lib/locale/locale-archive
7f1434d39000-7f1434d4f000 r-xp 00000000 fc:00 655527                     /usr/local/lib/libz.so.1.2.8
7f1434d4f000-7f1434f4e000 ---p 00016000 fc:00 655527                     /usr/local/lib/libz.so.1.2.8
7f1434f4e000-7f1434f4f000 r--p 00015000 fc:00 655527                     /usr/local/lib/libz.so.1.2.8
7f1434f4f000-7f1434f50000 rw-p 00016000 fc:00 655527                     /usr/local/lib/libz.so.1.2.8
7f1434f50000-7f1434f52000 r-xp 00000000 fc:00 2883655                    /lib/x86_64-linux-gnu/libdl-2.15.so
7f1434f52000-7f1435152000 ---p 00002000 fc:00 2883655                    /lib/x86_64-linux-gnu/libdl-2.15.so
7f1435152000-7f1435153000 r--p 00002000 fc:00 2883655                    /lib/x86_64-linux-gnu/libdl-2.15.so
7f1435153000-7f1435154000 rw-p 00003000 fc:00 2883655                    /lib/x86_64-linux-gnu/libdl-2.15.so
7f1435154000-7f1435307000 r-xp 00000000 fc:00 2883609                    /lib/x86_64-linux-gnu/libcrypto.so.1.0.0
7f1435307000-7f1435506000 ---p 001b3000 fc:00 2883609                    /lib/x86_64-linux-gnu/libcrypto.so.1.0.0
7f1435506000-7f1435521000 r--p 001b2000 fc:00 2883609                    /lib/x86_64-linux-gnu/libcrypto.so.1.0.0
7f1435521000-7f143552c000 rw-p 001cd000 fc:00 2883609                    /lib/x86_64-linux-gnu/libcrypto.so.1.0.0
7f143552c000-7f1435530000 rw-p 00000000 00:00 0
7f1435530000-7f14356e4000 r-xp 00000000 fc:00 2884139                    /lib/x86_64-linux-gnu/libc-2.15.so
7f14356e4000-7f14358e3000 ---p 001b4000 fc:00 2884139                    /lib/x86_64-linux-gnu/libc-2.15.so
7f14358e3000-7f14358e7000 r--p 001b3000 fc:00 2884139                    /lib/x86_64-linux-gnu/libc-2.15.so
7f14358e7000-7f14358e9000 rw-p 001b7000 fc:00 2884139                    /lib/x86_64-linux-gnu/libc-2.15.so
7f14358e9000-7f14358ee000 rw-p 00000000 00:00 0
7f14358ee000-7f1435943000 r-xp 00000000 fc:00 2884155                    /lib/x86_64-linux-gnu/libssl.so.1.0.0
7f1435943000-7f1435b42000 ---p 00055000 fc:00 2884155                    /lib/x86_64-linux-gnu/libssl.so.1.0.0
7f1435b42000-7f1435b45000 r--p 00054000 fc:00 2884155                    /lib/x86_64-linux-gnu/libssl.so.1.0.0
7f1435b45000-7f1435b4c000 rw-p 00057000 fc:00 2884155                    /lib/x86_64-linux-gnu/libssl.so.1.0.0
7f1435b4c000-7f1435b6e000 r-xp 00000000 fc:00 2884145                    /lib/x86_64-linux-gnu/ld-2.15.so
7f1435d57000-7f1435d5c000 rw-p 00000000 00:00 0
7f1435d6a000-7f1435d6e000 rw-p 00000000 00:00 0
7f1435d6e000-7f1435d6f000 r--p 00022000 fc:00 2884145                    /lib/x86_64-linux-gnu/ld-2.15.so
7f1435d6f000-7f1435d71000 rw-p 00023000 fc:00 2884145                    /lib/x86_64-linux-gnu/ld-2.15.so
7ffd85795000-7ffd85997000 rw-p 00000000 00:00 0                          [stack]
7ffd859b2000-7ffd859b4000 r-xp 00000000 00:00 0                          [vdso]
ffffffffff600000-ffffffffff601000 r-xp 00000000 00:00 0                  [vsyscall]
er_id"
Received unknown cookie "ajs_group_id"
Received unknown cookie "ajs_anonymous_id"
Received unknown cookie "__utma"
Received unknown cookie "_ga"
Received unknown cookie "__unam"
Received unknown cookie "__utma"
Received unknown cookie "tk_ni"
Received unknown cookie "ajs_user_id"
Received unknown cookie "ajs_group_id"
Received unknown cookie "ajs_anonymous_id"
Received unknown cookie "cache_disable"
Received unknown cookie "NO_CACHE"
Received unknown cookie "__utma"
Received unknown cookie "_ga"
Received unknown cookie "__unam"
Received unknown cookie "__utma"
Received unknown cookie "tk_ni"
Received unknown cookie "ajs_user_id"
Received unknown cookie "ajs_group_id"
Received unknown cookie "ajs_anonymous_id"
Received unknown cookie "__utma"
Received unknown cookie "_ga"
Received unknown cookie "__unam"
Received unknown cookie "__utma"
Received unknown cookie "tk_ni"
Received unknown cookie "ajs_user_id"
Received unknown cookie "ajs_group_id"
Received unknown cookie "ajs_anonymous_id"
Received unknown cookie "__utma"
Received unknown cookie "_ga"
Received unknown cookie "__unam"
Received unknown cookie "__utma"
Received unknown cookie "tk_ni"
Received unknown cookie "ajs_user_id"
Received unknown cookie "ajs_group_id"
Received unknown cookie "ajs_anonymous_id"
Received unknown cookie "__utma"
Received unknown cookie "_ga"
Received unknown cookie "__unam"
Received unknown cookie "__utma"
Received unknown cookie "tk_ni"
Received unknown cookie "ajs_user_id"
Received unknown cookie "ajs_group_id"
Received unknown cookie "ajs_anonymous_id"
  6001   Thu Nov 24 14:42:57 2011 KojiUpdateelogelogd gained an immunity to googlebot

I modified elogd.c as shown below in order not to allow to display all of the entries at once by specifying page number "0".

After this modification, elog seems to have survived 66 times of attacks by googlebots.

==============================

rossa:src>pwd
/cvs/cds/caltech/elog/elog-2.8.0/src

rossa:src>diff elogd.c_orig elogd.c
19912a19913,19917
>
>    /* KA */
>    if (page_n<1)
>      page_n = 1;
>

  6003   Thu Nov 24 15:48:27 2011 IllustratorUpdateelogelogd gained an immunity to googlebot

elog_mario.png

golden-monkey.jpeg

 

 

  4081   Tue Dec 21 08:26:08 2010 ranaUpdateelogelogd is getting killed by Suresh

Suresh killed the elogd again from India. This was the log file:

Accept-Charset: ISO-8859-1,utf-8;q=0.7,*;q=0.7
Keep-Alive: 115
Referer: http://www.ligo.caltech.edu/~ajw/40m_upgrade.html
Cookie: elmode=threaded; __utma=65601905.411937803.1291369887.1291369887.1291369887.1; __utmz=65601905.1291369887.1.1.utmcsr=(direct)|utmccn=(direct)|utmcmd=(none); SITESERVER=ID=4981c5fd42ae53c9c9e0980f2072be4f
Via: 1.1 sfire5.du.ac.in:3128 (squid/2.6.STABLE6)
X-Forwarded-For: 10.11.1.120
Cache-Control: max-age=259200
Connection: keep-alive

Stop killing our elog!

  4085   Wed Dec 22 06:50:19 2010 ranaUpdateelogelogd is getting killed by Suresh

After another elog crash, I've blacklisted the domain that Suresh is using by editing the apache httpd.conf. Let's see what happens now.

  4091   Thu Dec 23 03:15:11 2010 KojiUpdateelogelogd is getting killed by Suresh

ELOG has crashed and I restarted it.

Actually the filtering is not effective so far as elog is not using apache but has its own web server inside.
So this just block the access to port 30889 (=SVN, Dokuwiki, etc).

Quote:

After another elog crash, I've blacklisted the domain that Suresh is using by editing the apache httpd.conf. Let's see what happens now.

 

  1319   Wed Feb 18 15:31:38 2009 steveBureaucracySAFETYemergency back-up lights checked
All 13 exit and  emergency back-up lights and their batteries were checked.
Two of  the batteries were replaced.
  4286   Mon Feb 14 11:23:24 2011 steveUpdateSAFETYenclosure door upgrade

The #3 enclosure door was removed for the carpenter shop this morning. They will make 5 full size doors with window on each.

TEMPORARY aluminum sheet is clamped into its place. This sheet should not be removed till new doors arrive.

The inside Formica color will be changed from white to black to reduce the green scattering.

Attachment 1: P1070418.JPG
P1070418.JPG
  5897   Tue Nov 15 16:16:34 2011 steveUpdatePSLenclosure interlocks are working on all sliding doors

Ben and Sam came over to fix one of  the east side  sliding  door sensor that had to be moved from the inside  to outside on the enclosure.

We turned off the 2w Innolight for 20minutes. The power is back on, the  PMC and MC locked itself immediately.

  8571   Tue May 14 14:24:56 2013 SteveUpdate40m Upgradingenclosure removal

 

 I'm planning to remove the ETMY optical table enclosure and move it over to CES Shop 8am Thursday morning.

We'll install spring loaded lathes, hooks and quick release pins.

The bridge will be reinforced with steel plate to support release pins on posts.

There will be an other cut out for cable feedtrough as it is shown on elog #8472

Let me know if this timing does not fit your work.

  8685   Thu Jun 6 09:58:13 2013 SteveUpdateendtable upgradeenclosure to chamber connection

 

 Thin wall connector from McMCarr#55275K25 was tested in 150 mW, 1 mm beam size of 1064 nm  overnight. It did not show any degradation.

Super-Compressible Duct for Air

Hose is made from 0.005" thick, double-ply metalized polyester with a fabric-enclosed steel wire support. 

Atm2, Enclosure viewport adaptor is shown in place of the viewport.

Soft gaskit -   durumeter hardness 10A - McMCarr#9010K51 was added on the 10" od sufaces of conflat and viewport adaptor to insure being air tight.

The duct connector clamped with soft braided elastic " Velstrech" brand loop.

 

Attachment 1: thinwallconnector.jpg
thinwallconnector.jpg
Attachment 2: 06061301.PDF
06061301.PDF 06061301.PDF
  8606   Tue May 21 17:03:45 2013 SteveUpdateendtable upgradeenclosure tops are sealed

Quote:

 

 I'm planning to remove the ETMY optical table enclosure and move it over to CES Shop 8am Thursday morning.

We'll install spring loaded lathes, hooks and quick release pins.

The bridge will be reinforced with steel plate to support release pins on posts.

There will be an other cut out for cable feedtrough as it is shown on elog #8472

Let me know if this timing does not fit your work.

 The bridge support posts were shimmed today. Surgical tubing 402R - o - rings were glued togeather with " instant krazy glue "

Atm2  Carey CH-3540 latches are compressed ~2.5 mm in the clamped position.

Atm3 is showing the captured quick release pin in the steel reinforced bridge that is supported by the post. It works great. The post screw is sealed by o-ring. The quick-pin is sealed by an epoxy attached copper cap.

Atm4 Enclosure is on it's back. Bottom o-ring can be seen. The hole reinforced bridge structure is visible.

Now I'm working on the window connection to the chamber. I'm very close leak checking this box.

In case of leaking around the top tubing seals we have two options:

a, cut down on the cover rim by 0.040"  or b, increase tubing diameter

Attachment 1: ETMYoptable.jpg
ETMYoptable.jpg
Attachment 2: surgtubclamps.jpg
surgtubclamps.jpg
Attachment 3: quickrelease.jpg
quickrelease.jpg
Attachment 4: reinforcbridge.jpg
reinforcbridge.jpg
  4496   Thu Apr 7 11:38:56 2011 steveUpdatePSLenclosure windows on the east side of the PSL

The PSL enclosure now have 4 windows on each side. The bottom rail guides on the east side will be replaced by  one  U-channel for smoother, more gentle sliding.

Door position indicator- interlock switches are not wired yet.

Attachment 1: P1070538.JPG
P1070538.JPG
  3065   Fri Jun 11 11:54:42 2010 kiwamuUpdateGreen Lockingend PDH with thermal feedback

A thermal feedback was installed to the end PDH locking and it works well. There are no saturations 

As I said the feedback signal was sometimes saturated at the sum-amp because the drive signal going to the laser PZT was large at low frequency (below 1Hz).

So I made a passive low pass filter which filters the signal controlling the temperature of the laser crystal, and put it before the temperature drive input.

Now the amount of the feedback signal got reduced when it is locked, and there are no saturations. It's very good.


(thermal property of the crystal) 

According to the specification sheet for the 1W Innolight, the thermal properties of the crystal are:

  Response coefficient : 3GHz/K 

  Temperature control coefficient : 1K/V

  Thermal response bandwidth: 1Hz 

 

(filter circuit and actuator response)

In order to feedback the signal blow 1Hz, a low pass fiter is needed. 

The attachment:1 shows the filter circuit I made.

Since I found that the drive input had an input impedance of 100kOhm, so I put relatively big resistors to have a moderate gain.

The expected actuator responses are also attached.

The blue curve represents the response of the PZT, the green is the thermal response including the low pass filter and the red curve is the total response composed of both the responses.

I assume that the PZT response is 1MHz/V according to Mott's measurement.

Also I assume that the thermal response intrinsically has two poles at 1Hz according to the specification listed above.

In the total response, there is a little gain reduction around 2Hz due to the cancelation of each other, but it still looks okay.

 

Attachment 1: LPF.png
LPF.png
Attachment 2: thermal_feedback.png
thermal_feedback.png
  3066   Fri Jun 11 13:32:28 2010 KojiUpdateGreen Lockingend PDH with thermal feedback

GJ!

Quote:

A thermal feedback was installed to the end PDH locking and it works well. There are no saturations 

As I said the feedback signal was sometimes saturated at the sum-amp because the drive signal going to the laser PZT was large at low frequency (below 1Hz).

So I made a passive low pass filter which filters the signal controlling the temperature of the laser crystal, and put it before the temperature drive input.

Now the amount of the feedback signal got reduced when it is locked, and there are no saturations. It's very good.

 