    Reply  Fri Mar 9 11:02:56 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
[H1]Too Many Fast Changing EPICS in New Conlog[/H1]
I have been monitoring the new conlog, and it already has far too many rows.
    Reply  Fri Mar 9 15:48:56 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
[SIZE=1]
I decided to make a backup of the database and then delete it and make a new database:
[code] 
    Reply  Fri Mar 9 16:28:10 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
I created a page on the wiki for the new EPICS log (conlog):
https://wiki-40m.ligo.caltech.edu/aLIGO%20EPICs%20log%20%28conlog%29
    Reply  Mon Jul 23 07:39:55 2012, Ryan Fisher, Summary, Computer Scripts / Programs, Alterations to base epics install for installing aLIGO conlog: 
Note:  The Conlog install instructions that I started from were located here:
https://awiki.ligo-wa.caltech.edu/aLIGO/Conlog
Entry  Wed Feb 27 14:59:01 2013, Evan, Update, , Altered MC demodulation phase Q_and_I_before.epsQ_and_I_after.eps
 I took out a short (~12 cm) SMA cable from the "LO input" path into the MC demod board in an attempt to maximize the power in Q and minimize
the power in I. The path might benefit from being shortened a little more, but it's hard to tell since I is noisy. (In the attached plots, channel 1 is
Q and channel 2 is I.)
    Reply  Mon Apr 15 22:39:10 2019, gautam, Update, Frequency noise measurement, Alternate setup with PSL pickoff 
[anjali, gautam]

just main points, anajli is going to fill out the details.

To rule out mode-matching as the reason for non-ideal output from the MZ, I suggested using the setup
Entry  Thu Feb 16 13:29:38 2017, gautam, Summary, General, Alternative Calibration Scheme AltCal.pdf
Summary:

Craig and I have been trying to put together a Simulink diagram of the proposed alternative calibration scheme. Each time I talk the idea over
with someone, I convince myself it makes sense, but then I try and explain it to someone else and get more confused. Probably I am not even thinking
    Reply  Thu Feb 16 21:55:47 2017, rana, Summary, General, Alternative Calibration Scheme 
Question for Craig: What does the SNR of our lines have to be? IF we're only trying to calibrate the actuator in the audio band over long time scales,
it seems we could get by with more frequency noise. Assuming we want a 1% calibration at 50-500 Hz, what is the requirement on the frequency noise PSD
curve?
    Reply  Tue Feb 21 13:51:35 2017, Craig, Summary, General, Alternative Calibration Scheme 
We get SNR in two ways: the amplitude of applied force and the integration time.  So we are limited in two ways: stability of the lock to applied
forces and time of locklosses / calibration fluctuations.

At the sites, you probably know that we blow our spectrum out of the water with the calibration lines, with SNRs of about 100 on the scale of
    Reply  Wed Feb 22 10:16:54 2017, rana, Summary, General, Alternative Calibration Scheme 
OK, but the questions still stands: "Assuming we want a 1% calibration at 50-500 Hz, what is the requirement on the frequency noise PSD curve?"




    Reply  Mon Feb 8 15:36:37 2016, gautam, Update, Green Locking, Alternative mode-matching scheme Modematch_alternative.pdf
I looked in the optics cabinet to see what lenses we have available, and re-ran the mode-matching calculation to see if we could find a better solution
- I'm attaching a plot for what looks like a good candidate (optimized mode-matching efficiency for the X mode is 100%, and for the Y mode,
it is 97.98%), though it does involve switching "L1", which is currently a 175mm efl lens, for a 125mm efl lens. I've also indicated
Entry  Tue Nov 23 22:45:59 2010, kiwamu, Update, Computers, Altium 
I installed and activated Altium, a PCB design software, on the Windows machine
M2.
With Altium I am going to design the triple resonant circuit for the
Entry  Sun Apr 12 19:31:43 2009, rana, Summary, Electronics, Amphony 2500 Headphones 
We bought the Amphony 2500 Digital Wireless headphones recently. The other cheapo headphones we have are OK for control room use, but have a lot of noise
and are, therefore, not useful for noise hunting.
Entry  Sun Mar 17 21:06:17 2019, Anjali, Update, ALS, Amplifier characterisation Gain_measurement.pdfAmplifier_gain.pdfnoise_measurement.pdfnoise_characterisation.pdf
The goal was to characterise the new amplifier (AP1053). For a practice, I did the characterisation of the old amplifier.This test is similar to that
reported in Elog ID 13602.


Attachment #1 shows the schematic of the setup for gain characterisation and Attachment #2 shows the results of gain characterisation. 
The
Entry  Sat May 24 22:56:57 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path 
I just realized that I forgot to elog this, but yesterday afternoon I bypassed the amplifier in the BeatX path, and now the X beatnote is about -27dBm. 
Arms lock nicely with ALS.
    Reply  Mon May 26 07:59:23 2014, Koji, Update, Electronics, Amplifier removed from BeatX path 
And the out-of-loop level of the ALSX compared with the previous measurement is ...?


    
        
            Quote:
        
        
            
    Reply  Tue May 27 11:58:45 2014, Jenne, Update, Electronics, Amplifier removed from BeatX path ALS_outofloop_27May2013.pdf
Sorry, I had been in a hurry when I worked on this last week, and again when I wrote the elog, but I wanted to at least put in a note for any weekend
workers.
The ALS beatnote setups need alignment on the PSL table.  However, even at very low RF beat frequency, the X beatnote now at low frequencies
Entry  Tue Aug 9 16:00:58 2011, Jenny, Update, PSL, Amplitude response of PZT AMresponsePZT.pngAMresponsePZT.png

The top plot shows a sweep from 10 kHz to 5 MHz of the ratio of the voltage output of the PD detecting power from the NPRO laser beam and the RF
    Reply  Mon Jul 6 17:41:19 2020, gautam, Update, LSC, An LSC puzzler LSCsignals.jpg
Last Tuesday evening, while attempting the PRFPMI locking, I noticed a strange feature in the LSC signals, which is shown in Attachment #1 (the PDF exported by dataviewer is 14MB so I upload the jpeg instead).
As best as I can tell, the REFL33 and POP22 channels show an abrupt jump in the signal levels, while the other channels do not. POP110 shows a slight jump
    Reply  Tue Jun 24 16:52:43 2014, Nichin, Update, Electronics, An RF cable re-installed 


    
        
            Quote:
        
        
            

            [Nichin, Eric G]
Entry  Tue Nov 4 19:17:53 2014, ericq, Update, Computer Scripts / Programs, Anaconda + CDSutils 
I've fallen down the rabbit hole of trying to reconcile our desire for newer versions of the Numpy and Scipy python packages with the use of our handy
cdsutils tools. 

I've set up an installation of Anaconda python in /ligo/apps/anaconda. Installing pyepics, nds2, and cdsutils was straightforward,
    Reply  Sat Nov 8 11:31:51 2014, rana, Update, Computer Scripts / Programs, Anaconda + CDSutils 


    
        
            Quote:
        
        
            

           I've fallen down the rabbit hole of trying to reconcile our desire for newer versions of the Numpy and Scipy python packages with the use
Entry  Wed Oct 2 10:50:20 2019, gautam, Update, CDS, Anaconda updated 
The anaconda distribution used by the control room workstations is actually installed on the shared drive (/cvs/cds/ligo/apps/anaconda/) for consistency
reasons. The version was 4.5.11. I ran the following commands to update it today. Now it is version 4.7.12.

conda update conda
    Reply  Sat Feb 5 23:03:04 2011, rana, koji, Summary, Electronics, Analog Frequency Discriminator: splitter + mixer + long cable mixer.pdfUntitled.pngfsm.png
This diagram shows the setup of the analog
Mixer-Frequency Discriminator (MFD).
The idea is similar to the one of the Schnupp Asymmetry for our Michelson
    Reply  Sun Feb 6 02:29:28 2011, rana, Update, Electronics, Analog MFD: longer cable mfd18.png
I swapped over to a 3x longer cable (old 65 ft. Pasternak cable from ancient 40m days). The old one was 6m, the new one is 18.2 m. It was already coiled
up so I put it into a tupperware box to shield it somewhat from the HVAC wind.
The noise went down nearly proportional to the length (after I recalibrated the DAQ channel for the ~3x higher phase->voltage gain). With this
Entry  Tue Apr 15 02:19:54 2014, Jenne, Update, LSC, Analog phasing of REFL11 and REFL55 
[Jenne, EricQ]
I told Koji that I wanted to play with the common mode servo this evening, and he pointed out that we only get the signals after the digital demod
phase angle in the digital system (obviously).  So, if I want to use either REFL11 or REFL55 for my CARM signal, I want to do something in analog-land
    Reply  Tue Apr 15 02:26:45 2014, ericq, Update, LSC, Analog phasing of REFL11 and REFL55 
For future reference:
As we were poking around with the common mode servo in an FPMI configuration, we locked CARM/DARM with ALS as in recent ELOGs.
MICH was locked on ASDC: ASDC -> MICH = 10.0 in the DCPD DoF Matrix (I couldn't easily get AS55Q working, ASDC worked quickly and good enough)
    Reply  Tue Apr 15 08:55:57 2014, Koji, Update, LSC, Analog phasing of REFL11 and REFL55 
I have never used such a long cable for RF phase adjustment. The speed of the signal is 2e8 m/s and the frequency is ~10e6 Hz. 
This means that the wavelength is only about 20m. How could you end up with ~100meters? 
The convenient way to remember the cable delay is "1m, 1MHz, 2deg". This gives us ~1.5m for 11MHz and 34deg.
Entry  Wed Dec 12 18:27:07 2018, Jon, Omnistructure, Upgrade, Analog signals, A/D Acromag added to vacuum system 
There turned out to be a few analog signals for the vacuum system after all. The TP2/3 foreline pressure gauges were never part of the digital system,
but we wanted to add them, as some of the interlock conditions should be predicated on their readings. Each gauge connects to an old Granville-Phillips
375 controller which only has an analog output. Interfacing these signals with the new system required installing an Acromag XT1221 8-channel
Entry  Fri Mar 29 19:23:49 2013, Gabriele, Jenne, Frogs, LSC, Analog whitening filter of REFL55 not switching 
We discovered that the analog whitening filter of the REFL55_I board is not switching when we operate the button on the user interface. We checked with
the Stanford analyzer that the transfer function always correspond to the whitening on.
The digital one is actually switching. We decided to keep the digital de-whitening on to compensate for the analog one. Otherwise we get a very
    Reply  Fri Mar 29 19:58:24 2013, Gabriele, Jenne, Frogs, LSC, Analog whitening filter of REFL55 not switching 


    
        
            Quote:
        
        
            

           We discovered that the analog whitening filter of the REFL55_I board is not switching when we operate the button on the user interface. We
Entry  Wed Jun 25 19:29:19 2014, Akhil, Update, Electronics, Analog-to-Digital Converter IMG_1496.png
 I have been trying to use an ADC with the Raspberry Pi to be able to measure the phase difference between FC input and output signals.I had a hard
time interfacing the ADC  with the Pi (setup attached) even after trying to debug the issue for last two days. So I and Eriq Q performed a system
reboot on the Pi and tried all the possible ways for the Pi to detect the ADC but we were not able to. At the end we decided to order another IC(Microchip
Entry  Tue Feb 2 13:14:09 2010, Koji, HowTo, IOO, Anatomy of New Focus Resonant EOM 
Joe let me use the resonant EOM for GigE phase camera for a while.
Then, I immediately started to open it :)
it uses the MiniCIrcuits T5-1T transformer and a TOKO RCL variable inductor.
Entry  Mon Dec 3 19:44:58 2007, Accelerometers on new mounts, Configuration, PEM, Andrey DSC_0194.JPGDSC_0195.JPGDSC_0196.JPG

I (Andrey) continued today working with new accelerometer mounting. (see entry #151 about my Friday work).
Entry  Thu Nov 1 19:55:03 2007, Andrey Rodionov, Bureaucracy, Photos, Andrey's photo DSC_0055.JPG
 
Entry  Tue Jun 3 12:33:36 2008, Andrey, Update, Cameras, Andrey, Josephb 

Continuing our work with cameras,
Entry  Thu Nov 1 19:55:59 2007, Andrey Rodionov, Bureaucracy, Photos, Andrey, Tobin, Robert - photo DSC_0092.JPG
 
Entry  Mon Jul 22 03:10:41 2013, rana, Summary, lore, Angel of the Y End Table? asdasd.jpg
 Trying to take an image or movie of the ETMY Transmon cam, we got instead this attached image.
I think it is just some scattered green light, but others in the control room think that it is a message from somewhere or someone...
    Reply  Mon Jul 22 06:58:17 2013, Lisa, Summary, lore, Angel of the Y End Table? image.jpg


    
        
            Quote:
        
        
            

            Trying to take an image or movie of the ETMY Transmon cam, we got instead this attached image.
Entry  Tue Apr 7 04:21:45 2015, ericq, Update, ASC, Angular Control during Locking 
[J, Q]

Alignment is making it tough for locks to last more than 10 minutes. Many (but not all) locklosses correlate with some optic drifting away, and
taking all of the light with it. The other locklosses are the quick ones that seem to pop up out of nowhere; we haven't made any headway on these.
Entry  Thu May 6 16:13:39 2021, Anchal, Summary, IMC, Angular actuation calibration for IMC mirrors IMC_Ang_Act_Cal_Kakeru_Tests.pdf
Here's my first attempt at doing angular actuation calibration for IMC mirrors using the method descibed in /users/OLD/kakeru/oplev_calibration/oplev.pdf
by Kakeru Takahashi. The key is to see how much is the cavity mode misaligned from the input mode of beam as the mirrors are moved along PIT or YAW.

There two possible kinds of mismatch:
Entry  Thu Apr 25 03:35:28 2013, Jenne, Update, Locking, Angular motion does not explain RIN RIN_estimation_from_angular_motion.nb.zip
Den made a nice elog about the PRMI RIN that we see a few weeks ago:  8464.  The
RIN that we're seeing is typically about ~30%.  The question at hand is: what is causing this power fluctuation, and more specifically,
is it the angular motion of the mirrors?
Entry  Wed Aug 27 10:55:35 2008, Yoichi, HowTo, Computers, Annoying behavior of the touch pads of the lab. laptops is fixed 
I was sick of the stupid touch pad behavior of the lab. laptops, i.e. firefox goes back and forth in the history when the cursor is moved.
It was caused by firefox mis-interpreting the horizontal scroll signal as back/forward command.
I stopped it by going to about:config in firefox and set mousewheel.horizscroll.withnokey.action to 0 and 
    Reply  Wed Jun 6 10:44:52 2018, gautam, Update, VAC, Annulus pressure channels added to frames AnsPressureLogged.png
[steve, gautam]

We added the following channels to C0EDCU.ini and restarted the daqd processes. Channels seem to have been added successfully, we will check
trend writing later today. Motivation is to have a long term record of annulus pressure (even though we are not currently pumping on the annulus).
Entry  Mon Aug 3 18:19:09 2015, Jessica, Update, General, Anodization of front panels accounted for redo_conduct1X.pngredo_conduct1Y.png
Previously, I had gotten the same results for the conductive and the isolated front panels. Today, I sanded off the anodized part on the back of the
conductive front panel. I checked afterwards with a mulitmeter to ensure that it was indeed conductive through all the SMA connectors. 

I drove a frequency of 29.359 Hz through the X Arm cable and 29.3592 Hz through the Y Arm cable, giving a difference of 200 Hz. Previously, there
Entry  Wed Jul 17 20:12:26 2019, Kruthi, Update, Cameras, Another GigE in place of analog camera zoomed_out_gige.pngosems_mc2.pngMC2.pdf
I've taken the MC2 analog camera
down and put another GigE (unit 151) in its place. This is just temporary and I'll put the analog camera back once I finish the MC2 loss map calibration. I'm using a 25mm focal
Entry  Fri Jul 5 20:57:04 2019, Koji, Update, SUS, Another M7.1 EQ Screenshot_from_2019-07-05_21-03-06.png
[Kruthi, Koji]

Koji came to the lab to align the IMC/IFO, but found the mirrors are dancing around. Kruthi told me that there was M7.1 EQ at Ridgecrest.
Looks like there are aftershocks of this EQ going on. So we need to wait for an hour to start the alignment work.
    Reply  Fri Jul 5 21:53:10 2019, Koji, Update, SUS, Another M7.1 EQ 
- ITM unstuck now
- IMC briefly locked at TEM00

A series of aftershocks came. I could unstick ITMX by turning on the damping during one of the aftershocks.
    Reply  Fri Jul 5 22:21:13 2019, Koji, Update, SUS, Another M7.1 EQ Screenshot_from_2019-07-05_22-19-57.png
In fact, ETMX was not stuck until the M7.1 EQ today. After that it got stuck, but during the after shocks, all the OSEMs occasionally showed full swing
of the light levels. So I believe the magnets are OK.
Entry  Fri Jun 27 18:03:46 2008, Jenne, Update, Electronics, Another bad cable in the MC servo 
Eric was helping me to measure the response of the LO input on the MC's Demod board, and when we disconnected the end of the cable between the demod board
and the delay line phase shifter for the 29.5MHz oscillator, we noticed that the phase shifter's end of the cable was loose, like the connector wasn't
fully connected. When we checked it by wiggling the connector, the SMA end fell off.  I made a new SMA end for the cable, and reinstalled the cable.  The