  6517   Tue Apr 10 23:56:44 2012 ranaUpdateComputersSensorayNow that Mike has got the Sensoray working,
Jenne/Suresh should grab some new images
of the ETM cage as Keiko did so that we can
  
  6523   Wed Apr 11 22:48:39 2012 ranaUpdateEnvironmentBLRMS   seis_blrms.png 
  6567   Wed Apr 25 18:59:47 2012 ranaUpdatePEMBlue Bird Pre-AmplifierUsually R is for resistors and D is for
diodes. Do you think from the schematic that
we should put diodes into the R slots? 
  
  6585   Mon Apr 30 18:46:34 2012 ranaUpdateComputersmegatronLast week I found that megatron was still
off after the power outage. Apparently, the
power recovery checklist had not been followed
  
  6694   Sun May 27 17:19:27 2012 ranaSummaryloreStrawberries We have placed some sweet giant strawberries
in the fridge; free for eating for anyone
working in the lab today or tomorrow:
 20120527_145826.jpg 
  6719   Wed May 30 20:12:15 2012 ranaUpdateIOOMC beam spot oscillationThis is a common occurrence when diagnostic
scripts are written without the ability to
handle exceptions (e.g. ctrl-c, terminal
  
  6745   Fri Jun 1 19:48:54 2012 ranaUpdateSUSOplevs all different, messed up 
 Its a good question, but the
answer is yes. At some level all of the OL
  
  6785   Thu Jun 7 13:18:42 2012 ranaUpdateSUSPRM is still oscillating  Set the PRM OL servo gains
to zero until someone can take care of this.
Turning off the buttons doesn't help anything
  
  6811   Wed Jun 13 02:24:02 2012 ranaUpdateGreen Lockingmy first modescan (sort of) That sounds goofy.
With the delay line technique,
you can get a linear signal over 50 MHz with
  
  6813   Wed Jun 13 11:10:56 2012 ranaUpdateGreen Lockingmy first modescan (sort of)You can easily calculate whether or not
the coarse readout will work by thinking
about the scan resolution you need given
  
  6839   Wed Jun 20 18:00:10 2012 ranaSummaryPSLsummaries Nice PSL summaries from LHO:
https://alog.ligo-wa.caltech.edu/aLOG/index.php?callRep=3187
  
  6877   Wed Jun 27 10:27:09 2012 ranaSummaryIOOhow to improve mode matching to armsThe MC waist is correct as is the arm RoCs.
Most likely the error is in the telescope
length or its distance from the MC. Jenne
  
  6888   Thu Jun 28 15:21:02 2012 ranaUpdateLockingPRMI work started, commissioning plan 
 Cycling the vacuum is easy.
Why not vent starting Thursday evening and
  
  6901   Mon Jul 2 00:41:13 2012 ranaSummaryGeneralclipping at BS, my plan 
 Start pumping on Monday before
Steve goes home.
  
  6976   Sun Jul 15 16:25:15 2012 ranaUpdateLSCPRMI LSC is making PRM motion worseAs   
  6993   Thu Jul 19 15:55:21 2012 ranaUpdateComputersused 'aptitude' to install software (TexLive) on rosalbaI used APTITUDE
to install texlive-full on rosalba so that
I could work on a paper. pdflatex was not
  
  6994   Fri Jul 20 11:59:27 2012 ranaUpdateComputer Scripts / ProgramsCONLOG not runningWE tried to use the new conlog today and
discovered that:
1) No one at the 40m uses conlog
  
  6995   Fri Jul 20 12:12:25 2012 ranaUpdatePSLPMC problems examinedJenne, Den, Rana
The PMC transmission has been varying
a lot and the MC seems unstable. Superstitious
 Untitled.png 
  7015   Mon Jul 23 21:54:48 2012 ranaUpdatePEMWeather Station Works!To get the code to run on c1pem1, we had
to move the old target back into the /cvs/cds/caltech/target/
directory.  It is in /cvs/cds/caltech/target/c1pem1/.
 Untitled.png 
  7034   Wed Jul 25 23:03:22 2012 ranaUpdatedigital noisenotch, lowpass filtersIf the problem is the precision in DTT,
then why would the noise change when the
corner frequency of the filter is changed?
  
  7039   Thu Jul 26 15:43:03 2012 ranaUpdateLSCmodelled ringdownYou cannot use the digital system for this.
You hook up a scope to the transmitted light
as well as the incoming light (after the
  
  7107   Tue Aug 7 16:21:16 2012 ranaUpdateSUSoptical table box wall proposal

    

       
            
  
  7110   Tue Aug 7 23:30:58 2012 ranaUpdateEnvironmentNearby EQ Just felt an EQ. Impulse moved some
vertical blinds by several mm.
Tue Aug 07 23:26:06 2012 
  
  7112   Tue Aug 7 23:33:44 2012 ranaUpdateSTACISMore noise dataLooks like you're just measuring the ADC
noise. You should add ADC noise to your plot.
To compare the geophones with the accelerometers,
  
  7126   Wed Aug 8 22:12:30 2012 ranaConfigurationIOOMC trans optics configured  The PDA255   
  7183   Tue Aug 14 21:01:51 2012 ranaUpdatePEMBLRMS   Screenshot-Untitled_Window.png 
  7187   Wed Aug 15 04:03:55 2012 ranaSummaryLSCY-Arm Locking0) Did a bunch of alignment to get beams
roughly centered on ETMY and ITMY and maximize
power. Adjusted the aperture and focus on
 yArmNoise_120815.pngyarm.pdf 
  7219   Fri Aug 17 14:45:51 2012 ranaUpdateCamerasvideo cameras in the dark The problem with the glow on the
ETMY face is due to the red light being scattered
off of the optical table from the HeNe laser
  
  7238   Tue Aug 21 00:02:05 2012 ranaSummaryComputer Scripts / ProgramsGDS/DTT bug: 10 digit GPS times not accepted I've noticed that we're experiencing this
bug which was previously seen at
  
  7239   Tue Aug 21 00:35:25 2012 ranaSummaryIOOVisibilities and ChromeMC and PMC vis:  Untitled.pdf 
  7257   Thu Aug 23 15:35:33 2012 ranaUpdate IMC Ringdown 
 It is HIGHLY unlikely
that the IMC mirrors are having any effect
  
  7258   Thu Aug 23 15:42:48 2012 ranaUpdateSTACISSTACIS signal box made 
 I found this
entry in the old 40m ilog which
 vsanni-1107222997.pdf 
  7263   Thu Aug 23 22:21:13 2012 ranaConfigurationIOOMCL turned back onI turned on some filters and gain in the
SUS-MC2_MCL filter bank tonight so as suppress
the seismic noise influence on MC_F. This
 mcl-screen.pngmcf-noise.pdf 
  7371   Mon Sep 10 19:04:32 2012 ranaUpdateGeneralplan On Friday, Koji and I adjusted the
beam pointing into the DRMI using the PZT
yaw and found that the beam inside the DRMI
  
  7382   Fri Sep 14 00:33:31 2012 ranaUpdatePSLPMC alignment - mystery in reflected powerThe PMC reflection made it seem that the
beam going into it was misaligned. I went
to the table and aligned the input beam to
 pmcr.jpge.pnga.png 
  7385   Fri Sep 14 01:18:51 2012 ranaUpdateCOC2 Layout ChangesAfter looking
at the in-vacuum layout I think we should
  
  7389   Fri Sep 14 18:15:43 2012 ranaUpdateASCFirst In Vac Picture 
 Looks good. Any way that you
can tell in an unambiguous way, where the
  
  7396   Mon Sep 17 07:57:58 2012 ranaUpdatePEMBS and AS tables for REFL change 
 This was in response to my
suggestion to move the REFL beam path to
  
  7400   Mon Sep 17 23:58:01 2012 ranaUpdateGeneralLast of In-vac mirror photos taken My hope is that the DRMI flashes
will be bright enough to see on the PO beams.
IF we get 10 mW through the Faraday, you
  
  7414   Wed Sep 19 23:17:25 2012 ranaConfigurationPSLAOM installationMannasa and Unni and I looked at the
RF driver for the AOM. It was fine.
With the ALC input left unconnected,
  
  7435   Mon Sep 24 20:28:13 2012 ranaSummaryelogrestarted elog: was unresponsive    
  7436   Mon Sep 24 23:45:39 2012 ranaUpdateGeneralPOP in-vac optics aligned, POY beam coming out of vac  What was the reasoning / resolution
of the POP forward/backward beam? Are we
going to have the right beam for DRMI locking?
  
  7459   Mon Oct 1 19:21:03 2012 ranaConfigurationPEMchanged PEM DQ channelsChanged the list of channels to be written
to frames from having the IN1 suffix to OUT.
Now we can load the calibration of the channel
  
  7489   Fri Oct 5 04:34:31 2012 ranaUpdateSUSHow about the slow machines?

    

       
            
  
  7499   Mon Oct 8 09:51:30 2012 ranaUpdateModern Controlstate estimation 
 I guess that the estimated
state has the same low pass filter, effectively,
  
  7507   Mon Oct 8 22:07:46 2012 ranaUpdateSUSDoors on, ready to pump

    

       
            
 20120921_200637.jpg 
  7515   Wed Oct 10 02:15:14 2012 ranaUpdateLSC11 MHz reconnected to EOM Absolutely hokey. What are
our requirements for this RFPD? What
are the power levels and SNR that we want
  
  7516   Wed Oct 10 02:20:34 2012 ranaUpdateSUSOptical Lever QPD mods Since we upgraded the CDS system,
I guess our ADC ranges have gone up but we
never did anything to the OLs to match the
 C1-CORE_OPTICS_SUM_DATA_ALL_TIME_0-1033801216-86400.png 
  7581   Fri Oct 19 16:24:39 2012 ranaUpdateLockingAlignment is really bad?? 
 VENT
  
  7588   Mon Oct 22 11:26:12 2012 ranaUpdateSUS PITCH damping needed 
Too bad - I thought it would at least
give a little damping. Since we want the
  
ELOG V3.1.3-