40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 288 of 341  Not logged in ELOG logo
ID Date Author Type Category Subject Text Attachments
  2690   Sun Mar 21 20:08:20 2010 kiwamu, ranaUpdatePSLEOM wasit sizeWe
are going to set the waist size to 0.1 mm for
 waist.pngwaist.py.zip 
  2689   Sun Mar 21 19:25:29 2010 ranaUpdatePEMGuralp2 centered againFrom this morning, now in calibrated units,
and with the Güralp self noise spec
from the Güralp manual.
 huddlez.png 
  2688   Sat Mar 20 18:34:19 2010 kiwamuSummaryElectronicsRE:advantege of our triple resonant EOMYes, I found it.
Their advantage is that their circuit
is isolated at DC because of the input capacitor.
  
  2687   Fri Mar 19 23:03:41 2010 ranaUpdatePEMGuralp2 centered againI went and double-checked and aligned the
styrofoam cooler at ~5:00 UTC. It was fine,
but we really need a better huddling box.
 huddlez.png 
  2686   Fri Mar 19 21:15:33 2010 ranaUpdatePEMGuralp2 centered againThis trend of the last 200 days shows that
GUR2 has been bad forever...until now anyways.
 Untitled.png 
  2685   Fri Mar 19 18:00:14 2010 jenneUpdatePEMGuralp2 centered again[Jenne, Sanjit]
It looks like Steve used a GND-12V
supply to power the Guralp through the little
  
  2684   Thu Mar 18 21:42:26 2010 KojiUpdateABSLPLL reconstructedI checked the setup further more.

    I replaced the PD from
NewFocus 1GHz one to Thorlabs PDA255.
  
  2683   Thu Mar 18 19:00:04 2010 KojiSummaryElectronicsadvantege of our triple resonant EOMDid you find what is the merit of their
impedance matching technique?

  
  2682   Thu Mar 18 15:33:17 2010 kiwamuSummaryElectronicsadvantege of our triple resonant EOMIn
this LVC meeting I discussed about triple
resonant EOMs with Volker who was a main
 electrode.png 
  2681   Thu Mar 18 13:40:35 2010 KojiUpdateABSLPLL reconstructedWe use the current PLL just now, but the
renewal of the components are not immediate
as it will take some time. Even so we need
  
  2680   Thu Mar 18 12:27:56 2010 AlbertoUpdateABSLPLL reconstructed


   
        
            
  
  2679   Thu Mar 18 10:46:51 2010 KojiUpdateABSLPLL reconstructedLast night (Mar 17) I checked the PLL
setup as Mott have had some difficulty to
get a clean lock of the PLL setting.
  
  2678   Thu Mar 18 08:49:51 2010 steveUpdatePEMGuralp2 centered again ? 
Someone adjusted the Guralp2 mass
position last night??
 grlp2xadj.jpg 
  2677   Tue Mar 16 09:37:30 2010 steveUpdateSUSeq 4.4 seen by oplevs and osemsThe oplev plots clearly show the alignment
effect of this eq.
 opleveq4.4.jpgeq4.4.jpgopleveq4.4d3.jpg 
  2676   Tue Mar 16 05:10:39 2010 kojiUpdateEnvironmentEarthquake, Mag 4.4 Some of the suspensions got watchdog tripped
-> enabled -> damped.
The MC mirrors got slightly misaligned.
 100316_MC_SUS.png 
  2675   Tue Mar 16 04:22:02 2010 JenneUpdateEnvironmentEarthquake, Mag 4.4 Earthquake Details

    

       
            Magnitude
 EQ_16Mar2010.png 
  2674   Mon Mar 15 16:39:36 2010 steveUpdatePEMGuralp2 centered

    
        
 grlp2ffst.jpg 
  2673   Mon Mar 15 09:43:47 2010 steveUpdatePEMmore sandblasting todayDo not open IFO vacuum envelope today!
They are sandblasting again at CES
  
  2672   Sat Mar 13 22:16:03 2010 ranaUpdateWienerFilteringGuralp Huddle Test softwareI used some recent better data to try for
better Z subtraction.
Dmass helped me understand that sqrt(1-Coherence)
 guralpznoise.png 
  2671   Sat Mar 13 21:30:22 2010 ranaUpdatePEMStyrofoam Cooler on the Seismos   Untitled.png 
  2670   Fri Mar 12 17:08:22 2010 steveConfigurationVACbg-RGAscan at d18RGA scan of rga-region only at day 18  
This is the back ground of the rga with some
calibration gas.
 bg-d18_20100312scan.png 
  2669   Fri Mar 12 13:52:18 2010 ZachUpdateelogelog restarted The elog was down and I ran the restart
script.
  
  2668   Thu Mar 11 17:51:04 2010 KojiUpdateSUSRecent status of SOSsJenne, Koji
Recent status of SOSs:
  
  2667   Thu Mar 11 15:24:51 2010 steveMetaphysicsEnvironmentIFO was well protected

    
        
  
  2666   Wed Mar 10 15:02:58 2010 ranaUpdatePEMStyrofoam Cooler on the SeismosThis is the spectra and coherence from
a quiet time last night. I've lowered the
Guralp cal by a factor of 2 to account for
 Seismic-Ref_100310.pngUntitled.gif 
  2665   Tue Mar 9 12:06:53 2010 rana, JenneUpdatePEMStyrofoam Cooler on the SeismosLooks like the GUR2_X signal is bad. Jenne
says that we need to center it mechanically
before the signals will become useful again.
  
  2664   Tue Mar 9 09:32:31 2010 KojiSummaryGeneralWideband measurement of Fast PZT responseI have measured a wideband response
of the fast PZT in the LWE NPRO 700mW in
the Alberto's setup.
 PZT_response.png 
  2663   Tue Mar 9 09:04:20 2010 steveUpdatePEMkeep vacuum chamber closedThey are sandblasting at CES: our particle
counts are very high. DO NOT OPEN CHAMBER!
 sandblasting.jpg 
  2662   Mon Mar 8 18:15:27 2010 ranaUpdatePEMStyrofoam Cooler on the SeismosI put Jenne's
cooler over the seismometers
 SeismometersHuddled.jpg 
  2661   Sun Mar 7 23:05:39 2010 ranaUpdatePEMSeismic witnesses near MC1 tank moved

    
        
 seis.png 
  2660   Sun Mar 7 07:01:21 2010 ranaUpdateWienerFilteringGuralp Huddle Test softwareWe need to do a new huddle test of the
Guralps for the Wiener filtering paper. The
last test had miserable results.
 huddlez.png 
  2659   Fri Mar 5 18:04:56 2010 ranaUpdateSUSused OSEMs are magneticThe OSEM LEDs and PDs from Honeywell have
always had some ferromagnetic material in
them. These are the same OSEMs we had since
  
  2658   Fri Mar 5 11:21:18 2010 steveUpdateSUSused OSEMs are magnetic


   
        
            
  
  2657   Thu Mar 4 22:07:21 2010 ranaUpdate40m Upgrading11MHz PD not yet designedUse 10 Ohms for the resistance - I have
never seen a diode with 25 Ohms.
p.s. PDFs can be joined together
  
  2656   Thu Mar 4 19:53:56 2010 AlbertoUpdate40m Upgrading11MHz PD designed adjusted for diode's resistance; 55 MHz RFPD designedAfter
reading this study done
 6x 
  2655   Thu Mar 4 08:43:35 2010 AlbertoUpdate40m Upgrading11 MHz RFPD elctronics


   
        
            
 rfpd11_v2.fil 
  2654   Thu Mar 4 02:25:14 2010 JenneUpdateCOCFurther details on the magnet story, and SRM guiderod glued[Koji, Jenne]
First, the easy story:  
  
  2653   Wed Mar 3 18:32:25 2010 AlbertoUpdate40m Upgrading11 MHz RFPD elctronics** Please
add LISO file w/ component values.
 
 rfpd11_v2_TF.pdfrfpd11_v2_Noise.pdf 
  2652   Wed Mar 3 02:57:29 2010 JenneUpdateSUSITMX hung


   
        
            
  
  2651   Tue Mar 2 23:11:43 2010 KojiUpdateSUSITMX hungJenne and Koji
We successfully hung ITMX on the
SOS. Side magnet is ~2mm off from the center
  
  2650   Tue Mar 2 12:20:54 2010 kiwamuUpdatePSLstray beamIn order to block stray beams, I have
put some beam dumps and razor blades on the
PSL  table.
  
  2649   Mon Mar 1 22:38:12 2010 ranaUpdateComputersRC sensitivity to RINThe overnight triangle wave I ran on the
AOM drive turns out to have produced no signal
in the FAST feedback to the PZT.
 Untitled.png 
  2648   Mon Mar 1 11:21:50 2010 steveConfigurationVACvacuum contoller is back to normal


   
        
            
  
  2647   Mon Mar 1 08:49:37 2010 steveBureaucracySAFETYsafety auditThe 40m safety audit will be at Wednesday
afternoon, March 3
Please participate getting our lab
  
  2646   Sun Feb 28 23:47:52 2010 ranaUpdateComputersrosalbaSince Rosalba wanted to update ~500
packages, I let it do it. This, of course,
stopped the X server from running. I downloaded
  
  2645   Sun Feb 28 16:45:05 2010 ranaSummaryGeneralPower ON Recovery
    Turned ON the RAID above linux1.

   Hooked up a monitor and keyboard and
then turned ON linux1.
    After
  
  2644   Fri Feb 26 15:32:13 2010 steveConfigurationVACpreparation for power outage: vacuum all offThere is a planned power outage tomorrow,
Saturday from 7am till midnight.
I vented all annulies and switched
 ventd3.jpg 
  2643   Fri Feb 26 11:48:36 2010 KojiUpdateGeneralMC incident beam shiftLast night I worked on the MC incident
beam such that we can hit the center of the
MC mirrors.
  
  2642   Fri Feb 26 01:00:07 2010 JenneUpdateCOCSuspension ProgressThis is going to be a laundry list of the
mile markers achieved so far:
* Guiderod and wire standoff glued
  
  2641   Thu Feb 25 19:59:50 2010 KojiConfigurationSUSITMX OSEMsKoji, Steve
ITMX OSEM CONFIGURATION
 
 osem_config_ITMX.png 
ELOG V3.1.3-