40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 288 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  4160   Fri Jan 14 20:39:20 2011 ranaUpdateCDSUpdated some DAQ channel namesI like this activateDAQ script, but someone   
  4162   Mon Jan 17 04:10:10 2011 ranaConfigurationComputersNTPD restarted on c1dcuepics (to fix the MEDM screen times)I installed NTPD on Megatron (its Ubuntu,
so different from the CentOS workstations).
Here's the terminal cap to show that its
  
  4164   Mon Jan 17 20:13:38 2011 ranaUpdateElectronicsPOX_11 Optical TFI used 50 mA to drive the laser diode.
The light is split 50/50 between the DUT
(Device Under Test) and the New Focus 1611
 A.TIF 
  4180   Thu Jan 20 22:17:12 2011 ranaSummaryLSCFPMI Displacement NoiseI found this old plot in an old elog entry
of Osamu's (original
link).
 osamu-1140657006.pdf 
  4185   Fri Jan 21 23:17:54 2011 ranaHowToDAQDAQ Wiki FailureThe DAQ Wiki pages say to use port 8088
for restarting the Frame Builder. I tried
this to no avail.
  
  4186   Fri Jan 21 23:55:25 2011 ranaConfigurationLSCPhase Noise Measurement filterWe've set up a beat note measurement between
the VCO driver and the Marconi (see Suresh's
elog).
 a.gif 
  4192   Mon Jan 24 09:33:08 2011 ranaUpdateGreen LockingX arm locked !Very cool.
But the PLL seems very fishy to me.
The ZP-3MH needs 13 dBm to operate correctly.
  
  4216   Thu Jan 27 23:21:50 2011 ranaSummaryGreen LockingDigital Frequency DiscriminatorThat's some pretty fast work! I
thought we would be taking up to a week to
get that happening. I wonder what's the right
  
  4226   Sat Jan 29 03:13:44 2011 ranaUpdateWienerFilteringImprovement in H1 Wiener FF prediction by using weights and taps(Jenne, Rana)
Tonight we noticed that there
were significant improvements to be had in
 darmweight.pngdarm3000.png 
  4252   Fri Feb 4 18:58:19 2011 ranaUpdateComputersTemporarily removed cronjob for rsync.backup

    
        
  
  4255   Sun Feb 6 02:29:28 2011 ranaUpdateElectronicsAnalog MFD: longer cableI swapped over to a 3x longer cable (old
65 ft. Pasternak cable from ancient 40m days).
The old one was 6m, the new one is 18.2 m.
 mfd18.png 
  4258   Mon Feb 7 21:23:11 2011 ranaConfigurationPSLPSL FSS Temperature Sensor Interface box removedI noticed that the RMTEMP channel was spiking
myteriously when Kiwamu opened the PSL door.
We found out that the LEMO connectors would
 P2070555-1.JPG 
  4276   Sat Feb 12 23:22:21 2011 ranaUpdateElectronicsREFL11 Photodiode replaced375 mW is way too much light. We must never
put more than 100 mW on any of these diodes.
We don't want to blow up more diodes like
  
  4282   Mon Feb 14 01:19:18 2011 ranaUpdateCDSToday's CDS problemsThis is just a listing of  CDS problems
I still notice today:

    
    MC2-MCL
  
  4292   Mon Feb 14 21:59:35 2011 ranaUpdateCDSUpdated some DAQ channel namesAlthough Joe and Kiwamu claim
that they have inserted the correct DAQ names
for the OPLEVs (e.g. PERROR and YERROR) back
  
  4293   Mon Feb 14 23:29:04 2011 ranaSummarySUSETMX Fitlers moved aroundAll of the SUS used to have only 1 filter
module for SIDE. They now have 3 filter modules
for SIDE just like the other DOFs.
  
  4304   Tue Feb 15 21:45:08 2011 ranaUpdateIOOThe MC TRANS StoryI forgot
to elog that last night I touched
up the MC2_TRANS QPD setup
 a.png 
  4309   Wed Feb 16 23:54:34 2011 ranaUpdateCDSToday's CDS problems
    ETMX cannot load his filter
coefficients. Even if I change the file,
the load button doesn't work. I tried changing
  
  4318   Thu Feb 17 23:11:40 2011 ranaUpdateElectronicsVCO Frequency Noise Measurement with the MFDThis is the 140 ft. MFD measurement of
the VCO phase noise. It is open loop
and so should be a good measurement. The
 vco.png 
  4319   Thu Feb 17 23:41:46 2011 ranaFrogsDAQFrames Directory got the wrong name: Data unreachableDTT stopped working for recent data. An
'ls' in the frames/full/ directory reveals:
drwxr-xr-x 2 controls controls
  
  4329   Sat Feb 19 01:58:20 2011 ranaSummaryElectronicsLow Noise BJT Pre-AmpFrank put his low noise preamp info here.
I suggest that we build these (using
  
  4333   Mon Feb 21 17:29:57 2011 ranaSummaryIOOMyterious data loss: FB needs investigationLooks like there was a mysterious loss
of data overnight; since there's nothing
in the elog I assume that its some kind of
 Untitled.png 
  4363   Sun Feb 27 13:09:56 2011 ranaUpdateGreen Lockingsidebands on beatnoteWhen Koji and I were massaging the MC,
we noticed that the oscillations were at
48.5 kHz. They were pretty huge and are probably
  
  4375   Thu Mar 3 20:30:03 2011 ranaSummaryPSLPMC Sweeps @ different input power levels to measure the FinesseIts been well
noted in the past that sweeping the PMC
at high power leads to a distortion of the
  
  4400   Thu Mar 10 14:30:53 2011 ranaUpdateGreen LockingIntensity noise limits the beatnote sensitivityThere are 3 standard techniques to
reduce this effect:
1) Stabilize the end laser by sensing
  
  4403   Thu Mar 10 21:45:34 2011 ranaUpdateGreen LockingIntensity stabilization loop using beatnote DC.Ridiculous
and hacky. Digital stabilization removed
as well as the old "leave a pile of
  
  4408   Sun Mar 13 04:00:53 2011 ranaUpdateCDSETMY Sim workI did some work on the ETMY   
  4450   Mon Mar 28 18:13:32 2011 ranaUpdateGreen Lockinga mixer schoolUsing 2 dBm for a Level 7 mixer is so bogus,
that I will dismantle this as soon as I come
over.
  
  4453   Mon Mar 28 22:56:14 2011 ranaUpdatePSLNew PMC Base Riser DesignIts going to need some kind of way to locate
the PMC on the top. In the previous design,
we had the 3 balls to decouple the body from
  
  4507   Mon Apr 11 09:49:53 2011 ranaUpdateElectronicsNew Green PD test1 Ooh. Can you explain the purpose
of the resistors which are connected to the
(+) inputs? It looks like some real electronics
  
  4514   Mon Apr 11 23:35:02 2011 ranaUpdateRF SystemInstalled low pass filters in the demod boardsI am a little concerned about using these
low pass filters so close to the band edge.
Recall that there is no on-board preamp for
  
  4537   Sat Apr 16 02:00:14 2011 ranaUpdateLSC11MHz demod board : 90 degree splitterOne way to avoid some of the bad stuff
in there is to take the 1 dBm input and amplify
it to ~21 dBm before splitting and sending
  
  4559   Fri Apr 22 10:28:22 2011 ranaUpdateRF SystemRF Source HarmonicsYou should be able to resolve the other harmonics
by [B][COLOR=blue]decreasing the IF BW or
RBW[/COLOR][/B] on the analyzer. Even though
  
  4568   Tue Apr 26 01:20:02 2011 ranaUpdateElectronicsPOX_11 debuggingThe performance plots for   
  4569   Tue Apr 26 22:03:49 2011 ranaUpdateElectronicsPOX_11 debuggingI used the Jenne AM laser to tune up the
PD (used to be POX_11 but now is called REFL_11).
In addition to the notch at 22 MHz, I have
 MM7.png 
  4576   Wed Apr 27 21:08:08 2011 ranaUpdateLSCAS11I worked
on AS_11 today. Its ready for its noise /
 AS11.png 
  4589   Fri Apr 29 13:58:36 2011 ranaUpdateLSCY arm locked : details

    
        
  
  4620   Tue May 3 18:46:06 2011 ranaUpdateIOOMC Locking not workingI found that the MC autolocker was OFF.
Kiwamu says he turned it off because its
slow. Suresh says that he has some feelings
 Untitled.pngUntitled.png 
  4647   Thu May 5 18:38:01 2011 ranaSummaryCDSSub-system TRAMP adjustmentsI think
that the gain ramping time (_TRAMP) should
  
  4661   Sun May 8 17:29:01 2011 ranaUpdateIOOMC beam spot centeringIt seems like the best option would be
to make the MCASS just adjust the SUS biases
and center the beams on the suspended optics.
  
  4662   Sun May 8 22:59:40 2011 ranaUpdatePSLPSL reference cavity temperature box modificationsI looked at the PSL temperature box. It
started out as D980400-B-C. Then it was revised
by Peter King as per the LHO mods E020247.
  
  4672   Mon May 9 20:30:20 2011 ranaUpdatePSLPSL reference cavity temperature box modificationsI re-installed the box (@ ~8:15) after
reflowing some of the solder joints. I will
observe it over night and then remove the
 Untitled.png 
  4681   Tue May 10 20:57:05 2011 ranaUpdatePSLPSL reference cavity temperature box modifications : after 24 hours still OK

    
        
 Untitled.png 
  4693   Wed May 11 21:58:30 2011 ranaUpdateSUSETMX_OPLEV : He-Ne replaced

    
        
  
  4702   Thu May 12 10:27:02 2011 ranaUpdateRF Systeminstallation of RF splitters in Demod boards

    

       
            
  
  4705   Thu May 12 22:54:20 2011 ranaUpdateDAQInput Beam Naming change (no more IP) We decided to rename the Input Beam
channels (while keeping temporary backwards
compatible aliases) as:
  
  4707   Thu May 12 23:41:47 2011 ranaUpdateCDSMEDM Snapshots not workingLooks like 2 different MEDM Snapshot
functiions (at least) are broken.
The regular update of the screens
  
  4718   Sun May 15 03:58:19 2011 ranaUpdateCDSdiagonalization of MC input matrixThere has been some input matrix diagonalization
in the past by
Yuta and Kiwamu, but I find the automation
 mc1.png 
  4725   Mon May 16 11:14:36 2011 ranaUpdateIOOwiring diagram for IP-POSJust FYI, the 3113 is a 12-bit ADC, so
we won't get very good resolution out of
these. We should get one of those purple
  
  4743   Wed May 18 22:11:31 2011 ranaConfigurationLSCNew digital lockin added to LSC model/screen   Untitled.png 
ELOG V3.1.3-