40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 285 of 341  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  2287   Tue Nov 17 21:21:30 2009 robUpdateSUSETMY UL OSEMHad been disconnected for about two weeks. 
I found a partially seated 4-pin LEMO cable
coming from the OSEM PD interface board. 
  
  2290   Wed Nov 18 11:27:33 2009 Koji, josephbConfigurationSUSETMY suspension conencted to megatron ADC/DAC

    
        
  
  2291   Wed Nov 18 12:33:30 2009 Koji, josephbConfigurationSUSETMY suspension conencted to megatron ADC/DACHurraaaah!
We've got the damping of the suspension.
The Oplev loops has also worked!
The
 Untitled.png 
  2293   Wed Nov 18 16:24:25 2009 peteConfigurationSUSETMY suspension conencted to megatron ADC/DAC/cvs/cds/caltech/target/fb/daqd -c daqdrc
This starts the FB.
Now the dataviewer and DTT work!
  
  2307   Fri Nov 20 11:32:48 2009 HaixingUpdateSUSMagnetic levitationI added an integrator to increase
the gain at low frequencies (below 5 Hz).
In addition, I increased
 IntDiff.PNGS8007340.jpgS8007333.jpg 
  2309   Fri Nov 20 16:18:56 2009 robConfigurationSUSwatchdog rampdownI've changed the watchdog rampdown script
so it brings the SUS watchdogs to 220, instead
of the 150 it previously targeted. 
  
  2313   Mon Nov 23 11:03:00 2009 steveUpdateSUSjackhammer special well under control


   
        
            
 dig10d.pngP1050740.JPG 
  2331   Wed Nov 25 12:28:22 2009 JenneUpdateSUSMC2 trippedJust felt a big "kerplunk" type
ground-shaking, presumably from all the antics
next door.  MC2's watchdog tripped as
  
  2363   Tue Dec 8 03:53:49 2009 kiwamuUpdateSUSFree swinging spectra of ETMX In this night, I checked the free swinging
spectra of ETMX to make sure nothing wrong
with ETMX by the wiping.
 ETMX_air.png 
  2368   Tue Dec 8 23:13:32 2009 kiwamuUpdateSUSfree swinging spectra of ETMY and ITMXThe free swinging spectra of ETMY and ITMX
were taken after today's wiping, in order
to check the test masses.
 SUS-ETMY.pngSUS-ITMX.png 
  2369   Wed Dec 9 00:23:28 2009 KojiUpdateSUSfree swinging spectra of ETMY and ITMXWhere
is the plot for the trend?
It
  
  2372   Wed Dec 9 17:51:03 2009 kiwamuUpdateSUSwatchdogsPlease do not touch
the watchdogs for all SUSs except for MCs,
  
  2374   Wed Dec 9 21:09:28 2009 kiwamuUpdateSUSRe: free swinging spectra of ETMY and ITMXOkay, now the data are attached. At that
time I just wanted to say like the follower.
- - -
 Pitch-Yaw_modes.png 
  2375   Thu Dec 10 00:46:15 2009 KojiUpdateSUSRe: free swinging spectra of ETMY and ITMXWell, I get the point now. It could
be either seismic or change in the suspension
Q.
  
  2391   Thu Dec 10 17:13:36 2009 kiwamuUpdateSUSFree swiging spectra under the atmospheric pressureThe free swinging spectra of ITMs, ETMs,
BS, PRM and SRM were measured last night
in order to make sure that nothing wrong
 summary_freeswing.pdf 
  2405   Sun Dec 13 17:43:10 2009 kiwamuUpdateSUSfree swinging spectra (vacuum)The free swinging spectra of ITMs, ETMs,
BS, PRM and SRM were measured under the vacuum-condition.
The attachment are measured spectra.
 summary_FreeSwinging_vacuum.pdf 
  2433   Sun Dec 20 14:34:24 2009 KojiUpdateSUSETMY watchdog tripped Sunday 5:00AM localIt seemed that the ETMY watchdog tripped
early Sunday morning.
The reason is not known. I just looked
 Y.png 
  2457   Mon Dec 28 12:35:57 2009 JenneUpdateSUSMC2 is having a bad dayMC2 is having a bad day, and I'm not yet
sure why.  It's to do with the damping
though.  When the damping is off, after
  
  2458   Mon Dec 28 12:45:55 2009 KojiUpdateSUSMC2 is having a bad dayThe MCL path of MC2 was in a strange state
as the filters were activated as if it is
in lock even though we had no lock. So I
  
  2494   Sun Jan 10 13:32:09 2010 HaixingUpdateSUStransfer function measurement of the quadrant maglev circuit I have assembled the circuit and the
control box for the quadrant magnetic
levitation yesterday. The final setup
 6x 
  2495   Sun Jan 10 15:47:26 2010 KojiUpdateSUStransfer function measurement of the quadrant maglev circuit 1. Why do all of the BNCs have no GND connection?
Each should have the individual cables to
the ground. Each signal line and the corresponding
  
  2497   Sun Jan 10 16:50:34 2010 HaixingUpdateSUStransfer function measurement of the quadrant maglev circuit

    
        
  
  2498   Sun Jan 10 17:15:25 2010 KojiUpdateSUStransfer function measurement of the quadrant maglev circuit 1. Yes. That is the bad. You should eventually
replace the BNCs to the isolated ones.
2. OK. I like to emphasize again
  
  2510   Tue Jan 12 13:24:50 2010 HaixingUpdateSUSQuadrant Magnetic LevitationI have tried to make the quadrant magnetic
levitation work but unfortunately I did
not succeed. During the experiment, I
 schmematic.png 
  2574   Fri Feb 5 14:31:46 2010 JenneUpdateSUS2 SOS towers assembled[Jenne, Kiwamu]
The 2 SOS towers for the ITMs have
been assembled, and are on the flow bench
 DSC_1156.JPG 
  2641   Thu Feb 25 19:59:50 2010 KojiConfigurationSUSITMX OSEMsKoji, Steve
ITMX OSEM CONFIGURATION
 
 osem_config_ITMX.png 
  2651   Tue Mar 2 23:11:43 2010 KojiUpdateSUSITMX hungJenne and Koji
We successfully hung ITMX on the
SOS. Side magnet is ~2mm off from the center
  
  2652   Wed Mar 3 02:57:29 2010 JenneUpdateSUSITMX hung


   
        
            
  
  2658   Fri Mar 5 11:21:18 2010 steveUpdateSUSused OSEMs are magnetic


   
        
            
  
  2659   Fri Mar 5 18:04:56 2010 ranaUpdateSUSused OSEMs are magneticThe OSEM LEDs and PDs from Honeywell have
always had some ferromagnetic material in
them. These are the same OSEMs we had since
  
  2668   Thu Mar 11 17:51:04 2010 KojiUpdateSUSRecent status of SOSsJenne, Koji
Recent status of SOSs:
  
  2677   Tue Mar 16 09:37:30 2010 steveUpdateSUSeq 4.4 seen by oplevs and osemsThe oplev plots clearly show the alignment
effect of this eq.
 opleveq4.4.jpgeq4.4.jpgopleveq4.4d3.jpg 
  2717   Sat Mar 27 16:23:10 2010 KojiUpdateSUSanother SRM sidemagnet gluedKiwamu and Koji
Last night we have released PRM from
the gluing fixture. All of the six magnets
  
  2730   Mon Mar 29 18:41:34 2010 KojiConfigurationSUSStarted to build TTsSteve and Koji
WE started to build 5 TTs. 4 of them
are used in the recycling cavities. One is
 IMG_2348.jpg 
  2731   Mon Mar 29 18:50:14 2010 KojiUpdateSUSPRM sidemagnet gluedPRM was released from the fixuture without
any trouble. This was the last magnet gluing
until ETMs are delivered.
 StatusTable.png 
  2753   Thu Apr 1 17:35:24 2010 KojiUpdateSUSWorking on ITMX/YSteve and Koji
- We removed old ITMX/Y from the
chambers. Now they are temporarily placed
 IMG_2353.jpg 
  2766   Mon Apr 5 09:48:57 2010 KojiUpdateSUSITMs placed on the tables in the chambersSteve and Koji (Friday, Apr 02)
Summary
Intsallation of ITMs are going on.
  
  2769   Mon Apr 5 11:39:41 2010 steveUpdateSUSITM-south installation


   
        
            
  
  2773   Mon Apr 5 14:10:06 2010 steveUpdateSUSsus damping restored

    
        
  
  2777   Tue Apr 6 22:54:34 2010 KojiUpdateSUSITMY (south) alignedKiwamu and Koji
ITMY
(south) was aligned
 IMG_2362.jpg 
  2796   Mon Apr 12 22:51:31 2010 KojiUpdateSUSITMX installed and alignedKoji
ITMX
was aligned
 IMG_2381.jpg 
  2800   Tue Apr 13 20:02:02 2010 KojiUpdateSUSBS chamber opened, PRM/SRM SOS removed from the tableBob, Steve, and Koji
We
opened North heavy door of the BS chamber
 IMG_2384.jpg 
  2813   Tue Apr 20 08:00:52 2010 steveUpdateSUSETMY damping restoredETMY sus damping was restored   
  2848   Mon Apr 26 21:12:53 2010 KojiUpdateSUSPRM/SRM standoffs gluedKiwamu and Koji
The PRM/SRM were balanced with the
standoffs. We glued them to the mirror.
  
  2862   Fri Apr 30 23:16:51 2010 KojiUpdateSUSSRM/PRM ready for bakingKiwamu and Koji
- Checked the SRM/PRM balancing after
the gluing.
  
  2863   Sun May 2 13:04:51 2010 KojiSummarySUSCoil Actuator Balancing and Spot PositionI liked to know quantitatively where the
spot is on a mirror.

With an interferometer and A2L
 coil_balance.png 
  2865   Sun May 2 15:38:12 2010 ranaSummarySUSCoil Actuator Balancing and Spot Position 
Oh, but it gets even better: in order
to trust the A2L script in this regard you
  
  2866   Sun May 2 16:52:44 2010 KojiSummarySUSCoil Actuator Balancing and Spot PositionYes, of course. But so far I am trusting
that the coils are inheretly balanced.
Probably you are talking about the
  
  2867   Sun May 2 17:16:43 2010 KojiUpdateSUSHow to steer the incident beam to the MC?Deviations of the MC spot from the center
of the mirrors were measured.
MC1H = +0.29 mm
 steering.png 
  2868   Mon May 3 00:36:49 2010 KojiUpdateSUSHow to steer the incident beam to the MC?Actually, I tried some tweaks of the input
steering to get the  beam being more centered
on the MC mirrors on Saturday evening.
  
ELOG V3.1.3-