ID Date Author Type Categoryup Subject Text Attachments
  10885   Fri Jan 9 19:18:51 2015 JenneUpdatePSLPMC realignedA few hours ago I tweaked up the alignment
to the PMC.  It was really bad in pitch,
and the transmission was down to about 0.711.
  
  10909   Thu Jan 15 19:01:30 2015 ericqUpdatePSLPMC realignedPMC realigned again... The transmission
was down to 0.70, and the MC was having a
hard time trying to autolock.
  
  10913   Fri Jan 16 18:09:09 2015 JenneUpdatePSLPMC autolocker not running?Have we been running the PMC autolocker
lately?  I can't remember, and I
also can't find where it might be running. 
 PMCfuzz.pdf 
  10950   Wed Jan 28 17:32:26 2015 KojiUpdatePSLPMC alignedPMC aligned.

PMC Trans increased from 0.740
to 0.782
  
  10986   Sat Feb 7 13:34:11 2015 KojiSummaryPSLISS AOM driver checkI wanted to check the status of the ISS.
The AOM driver response was measured on Friday
night.
 AOM_drive.pdfAOM_response.pdf 
  10988   Sun Feb 8 21:54:50 2015 ranaSummaryPSLISS AOM driver checkThis is good
news. It means that the driver probably won't
limit the response of the loop - I expect
  
  11127   Tue Mar 10 14:47:05 2015 manasaUpdatePSLPMC relockedPMC was locked in a bad state. FSS slow
actuator adjust was at ~ -0.7 and PZT voltage
at ~45.
  
  11141   Fri Mar 13 23:49:28 2015 ranaUpdatePSLRelaxation Osc and the NPRO Noise eaterAnother thought about the mystery PCDRIVE
noise: we've been thinking that it could
be some slow death inside the NPRO, but it
  
  11373   Wed Jun 24 08:05:43 2015 SteveUpdatePSLlaser turned onThe laser went off around 11am yesterday.
It was turned on
 laserWasOff.png 
  11560   Wed Sep 2 23:50:00 2015 ranaUpdatePSLPMC LO dyingLet's order a pair of 35.5 MHz Wenzel
for this guy and package like Rich has done
for the WB low noise oscillators.
 PMCLO.png 
  11739   Mon Nov 9 09:27:44 2015 SteveUpdatePSLMC is not happyI just turned off the PSL enclousure lights.
 
 ioo8d.png 
  11756   Thu Nov 12 09:41:02 2015 SteveUpdatePSLPMCThe PMC is not happy and the ITMX UL OSEM
is moving too much

 
 PMC_ITMX.png 
  11763   Fri Nov 13 22:32:54 2015 KojiSummaryPSLPMC LO degraded, usual ERA-5 replacement, LO recovered[Yutaro, Koji]

We found that the PMC LO level
was fluctuating in a strage way (it was not
 PMC_LO.pngIMG_2093.JPGIMG_2091.JPGIMG_2095.JPGIMG_2096.JPG 
  11765   Sun Nov 15 22:43:48 2015 KojiSummaryPSLPMC LO degraded, usual ERA-5 replacement, LO recoveredI think the IMC locking was somewhat improved.
Still it is not solid as long time before.

Before the PMC fix (attachment
 C1-MULTI_E6875C_TIMESERIES-1131408017-86400.pngC1-MULTI_E6875C_TIMESERIES-1131580817-86400.png 
  11768   Mon Nov 16 19:05:59 2015 KojiSummaryPSLPMC servo circuit review, follow up measurementsPMC follow up measurements have been done.
The servo circuit was reviewed.

Now the PMC, IMC, X/Y arms are
  
  11769   Mon Nov 16 21:32:49 2015 KojiSummaryPSLPMC servo circuit review, follow up measurementsThe result of the precise inspection
for the PMC servo board for the 40m was done.

The record, including the
  
  11775   Tue Nov 17 16:21:10 2015 KojiSummaryPSLPMC servo circuit review, follow up measurementsI'm still analyzing the open loop TF
data. Here I report some nominal settings
of the PMC servo
  
  11780   Wed Nov 18 16:51:58 2015 KojiSummaryPSLPMC servo calibrationSummary

The PMC servo error (MIX OUT MON
on the panel) and actuation (HV OUT MON)
 PMC_err_cal.pdf 
  11781   Wed Nov 18 16:53:17 2015 KojiSummaryPSLPMC PZT capacitanceThe PMC PZT capacitance was measured.
- Turn off the HV supplies. Disconnect
HV OUT cable.
  
  11782   Wed Nov 18 17:09:22 2015 KojiSummaryPSLPMC Servo analysisSummary

The PMC servo was analysed. OLTF
was measured and modeled by ZPK (Attachment
 PMC_OLTF.pdfPMC_DSP.pdf 
  11793   Fri Nov 20 15:44:12 2015 KojiSummaryPSLAdded 17.5kHz LPF to the PMC servoAs a final tune of the PMC servo, I've
added 1nF cap at the error signal amplification
stage. The diagram has been updated and uploaded
 PMC_OLTF.pdfPMC_noise_comparison.pdf 
  11900   Wed Dec 23 15:43:02 2015 ranaSummaryPSLPMC FSS IMC RF summing boxThe EOM upstream of the PMC is used as
the phase corrector for the FSS/IMC servo.
It is also used to apply the 35.5 MHz PDH
 PMCFSSsummingBox.png 
  12169   Fri Jun 10 18:16:59 2016 varunUpdatePSLRealignment of pre mode cleanerThe mode cleaner was misaligned probably
due to the earthquake (the drop in the
MC transmitted value slightly after utc 7:38:52
 pmctrans_mcsum_signals.png 
  12170   Mon Jun 13 09:08:17 2016 SteveUpdatePSLPMC slow driftThe PMC transmission slow degration or
it's input beam is not stable.

 
 PMCslowDrift.png 
  12192   Thu Jun 16 18:08:57 2016 JohannesUpdatePSLBefore the AOM installationThere was only one razor blade beam dump
labeled for atmospheric use left, but that's
all we need. Steve is working on restocking.
 IMG_20160615_154556392e.jpg 
  12196   Fri Jun 17 22:36:11 2016 JohannesUpdatePSLAOM installationSubham and I have placed the AOM back into
the setup right in front of the PMC.

Steps undertaken:
 aom_new_mount.jpgaom_beam_split.jpgaom_dump_IR.jpg 
  12198   Mon Jun 20 08:26:56 2016 SteveUpdatePSLAOM picturesGood job Johannes and Subham.

 
 AOMinplace.jpginplaceAOM.jpgAOMin.png 
  12573   Wed Oct 19 18:32:25 2016 rana, yinziUpdatePSLRefCav thermal control: heater is deadWe wanted to re-activate the Heater for
the reference cavity today to use it as a
testbed for PID autotuning and the new heater
  
  12627   Fri Nov 18 17:52:42 2016 gautamUpdatePSLFSS Slow control -> Python, WFS re-engaged[yinzi, craig, gautam]

Yinzi had translated the Perl PID
script used to implement the discrete-time
  
  12628   Sun Nov 20 23:53:38 2016 awadeUpdatePSLFSS Slow control -> Python, WFS re-engagedI made a very slighly updated version of
Yinzi's script that pulls the channel
names and actuator hardstop limits from
  
  12792   Thu Feb 2 18:32:51 2017 ranaSummaryPSLPMC alignmentRe-aligned the beam going into the PMC
today around 5 PM. I noticed that its all
in pitch and since I moved both of the mirrors
  
  12911   Mon Mar 27 20:41:21 2017 rana, gautamUpdatePSLPMC DAQ assay for feed-forward integrationWe are thinking to use the PMC signals
to help us in figuring out the feedback /
feedforward stuff and making it better.
 TEK00000.PNG20170327_194931.jpg20170327_204554.jpg 
  12916   Wed Mar 29 11:41:19 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationThe C1IOO frontend machine that resides
in 1X1/1X2 has 2 ADCs, ADC0 and ADC1. The
latter has 28 out of 32 channels unused at
 C1ALS_PSLnamespace.pngPMCcheckout.pdfD980352-A-40m_151119.pdf 
  12918   Thu Mar 30 00:16:09 2017 gautamUpdatePSLPSL NPRO PZT calibrationAs part of the ongoing effort to try and
calibrate the PMC DAQ channels into physical
units, I tried to get a calibration for the
  
  12920   Thu Mar 30 18:11:01 2017 ranaUpdatePSLPMC DAQ assay for feed-forward integrationWhat you have drawn looks good to me: the
cut should be between TP3 and pin3 of the
AD620. This should maintain the DC coupled
  
  12925   Mon Apr 3 17:25:13 2017 gautamUpdatePSLPSL NPRO PZT calibrationSummary:

By sweeping the laser frequency
and looking at the PMC PDH error signal,
 PDHerr.pdfNPROcalib.pdf 
  12926   Mon Apr 3 23:07:09 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationI made some changes to the DAQ path on
the PMC servo board, as per the plan posted
earlier in this thread. Summary of changes:
  
  12928   Tue Apr 4 17:27:58 2017 ranaUpdatePSLPSL NPRO PZT calibrationgood cal. I wonder if this data also gives
us a good measurement of the cavity pole
or if the photo-thermal self-locking effect
  
  12939   Tue Apr 11 00:38:37 2017 gautamUpdatePSLPMC demod moved off servo boardAs discussed at the Wednesday meeting last
week, I tried moving the demodulation of
the PMC error signal off the PMC servo board,
 PMC_Ctrl_spec.pdf 
  12940   Wed Apr 12 00:36:53 2017 gautamUpdatePSLPMC demod moved off servo boardHere is a more detailed comparison of the
spectra of the signals at the front panel
DAQ LEMO output, measured with the Agilent
 PMC_digitalSpec.pdfPMC_DAQ_spectra.pdf 
  12944   Tue Apr 18 01:01:03 2017 gautamUpdatePSLPMC OLTF measured, DAQ channels calibratedQuick entry, details to follow in the AM
tomorrow.


I calibrated the PMC DAQ
 PMCspectra_calibrated.pdfPMC_MEDMs.png 
  12945   Tue Apr 18 16:10:00 2017 gautamUpdatePSLPMC OLTF measured, DAQ channels calibratedHere are the details:


PMC OLTF:


the
procedure used was identical to what Koji
 PMC_OLTF_170418.pdf 
  12946   Tue Apr 18 23:37:15 2017 ranaUpdatePSLPMC OLTF measured, DAQ channels calibratedWhat's
the reasoning behind setting the the gain
  
  12947   Wed Apr 19 15:13:30 2017 gautamUpdatePSLPMC/MCL multicoherenceI used a one hour stretch of data from
last night to look at coherence between the
PMC control signal and MCL, to see if the
 PMC_MCL_multicoherence.pdf 
  13137   Mon Jul 24 12:00:21 2017 gautamUpdatePSLPSL NPRO mysteriously shut offSummary:

At around 10:30AM
 IMG_7454.JPG 
  13213   Wed Aug 16 14:57:01 2017 SteveUpdatePSLref Cavity heating blanket power supplyThe last entry I found relating to ref
cavity was
2011 Aug 19
 refCavPSheat.jpgrefCavTempSens.jpgrefTempSen_1X1.jpg 
  13223   Thu Aug 17 08:42:27 2017 SteveUpdatePSLPSL HEPAThe PSL HEPA was running noisy at 100V  
The bearing is wearing out. I turned it down
to 30V It is quiet there.
  
  13264   Mon Aug 28 23:22:56 2017 johannesUpdatePSLPSL table auxiliary NPROI moved the axuiliary NPRO to the PSL table
today and started setting up the optics.

The Faraday Isolator was showing
 aom_switching_zoomin.pngaom_switching_zoomout.pngaom_switching_mini_zoomin.pngaom_switching_mini_zoomout.png 
  13270   Tue Aug 29 20:04:09 2017 ranaUpdatePSLPSL table auxiliary NPROI don't understand why the 1st order
diffracted beam doesn't go to zero when
you shut off the drive. My guess is that
  
  13271   Tue Aug 29 21:36:59 2017 johannesUpdatePSLPSL table auxiliary NPRO


 isomet_mini_1st_zoomout.pngisomet_mini_0th_zoomout.png 