40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 282 of 341  Not logged in ELOG logo
    Reply  Tue Jan 23 16:02:05 2018, Steve, Configuration, SEI, load cells stacis3LoadCells.pngDSC00025.JPGDSC00026.JPG
Entry  Tue Feb 13 21:22:44 2018, Steve, Update, SEI, one load cells tested as_measured_102kg.jpgsensor.jpg1500lbs_load__cell.jpg
    Reply  Wed May 2 10:03:58 2018, Steve, HowTo, SEI, preparation of load cell measurement at ETMX 6x
    Reply  Thu May 3 09:56:42 2018, Steve, HowTo, SEI, preparation of load cell measurement at ETMX 
    Reply  Mon May 14 08:55:40 2018, Dennis Coyne, HowTo, SEI, preparation of load cell measurement at ETMX 
Entry  Mon Apr 18 14:52:47 2022, Ian MacMillan, Summary, SEI, Seismic Study of Buildings and Caltech Campus 7x
    Reply  Thu Apr 21 17:32:35 2022, Ian MacMillan, Summary, SEI, Seismic Study of Buildings and Caltech Campus IMG_1820.jpgScreen_Shot_2022-04-21_at_5.52.51_PM.png
Entry  Thu Jun 21 09:01:18 2012, steve, Update, STACIS, the resurrection of STACIS -surf IMG_1364.JPG
Entry  Wed Jun 27 14:18:30 2012, Yaakov , Summary, STACIS, First week summary 
Entry  Mon Jul 2 23:08:38 2012, Yaakov, Update, STACIS, Turning on STACIS geo_open.GIFgeo_closed.GIFgeo_closed.GIFSCRN0005.GIFstacy1.JPG
Entry  Tue Jul 3 18:58:14 2012, Yaakov, Update, STACIS, More transfer functions and netGPIB status geo_open_y.pnggeo_open_x.pngaccel_open_x.png
Entry  Wed Jul 11 14:27:29 2012, Yaakov, Summary, STACIS, Current STACIS Status geo_open_z.pnggeo_open_z2.pngambient_open_z.pngambient_closed_z_geoFeed.pngopenVclosed.GIF
Entry  Thu Jul 12 15:43:07 2012, Yaakov, Update, STACIS, New input point, using accelerometers for feedback new_input.JPGcBoard_tFunction.png
Entry  Wed Jul 18 13:53:34 2012, Yaakov, Update, STACIS, Weekly update flange.JPGreally_accelFeed.GIF
Entry  Wed Jul 25 12:00:21 2012, Yaakov, Update, STACIS, Weekly update 
Entry  Thu Jul 26 16:08:59 2012, Yaakov, Update, STACIS, Noise plot update stacy_noise.bmpstacy_noise.figfeedbacks.bmpfeedbacks.fig
Entry  Mon Jul 30 17:24:45 2012, Yaakov, Update, STACIS, Revised sensor noise plot; dead PZT sensor_noise.bmpsensor_noise.bmpsensor_noise.fig
Entry  Mon Jul 30 22:52:51 2012, Yaakov, Update, STACIS, Geophone calibration 7x
Entry  Tue Jul 31 15:24:53 2012, Yaakov, Update, STACIS, Open loop gains and block diagram z_OL.figz_OL.bmpx_OL.bmpstacis_block.bmpx_OL.fig
    Reply  Tue Jul 31 19:34:55 2012, Koji, Update, STACIS, Open loop gains and block diagram 
Entry  Wed Aug 1 11:54:59 2012, Yaakov, Summary, STACIS, Geophone calibration and open loop gains 08011201.pdf
Entry  Tue Aug 7 21:34:50 2012, Yaakov, Update, STACIS, More noise data budget.bmpbudget.fig
    Reply  Tue Aug 7 23:33:44 2012, rana, Update, STACIS, More noise data 
Entry  Wed Aug 8 11:47:52 2012, Yaakov, Summary, STACIS, Weekly summary budget_with_adc.pngbudget_with_adc.figpower_diagram.png
Entry  Fri Aug 10 18:11:55 2012, Yaakov, Update, STACIS, Corrected noise budget, plan for external actuation 6x
Entry  Mon Aug 13 21:47:30 2012, Yaakov, Update, STACIS, Two changes to STACIS noise budget noise_budget_8-13.bmpnoise_budget_8-13.bmpnoise_budget_8-13.fig
Entry  Wed Aug 15 11:40:15 2012, Yaakov, Summary, STACIS, Weekly Summary  
Entry  Thu Aug 16 20:18:39 2012, Yaakov, Update, STACIS, Input for feedforward/feedback in the STACIS 6x
Entry  Sun Aug 19 19:56:20 2012, Yaakov, Update, STACIS, STACIS signal box made SAM_0275.JPGSAM_0277.JPGSAM_0276.JPG
    Reply  Thu Aug 23 15:42:48 2012, rana, Update, STACIS, STACIS signal box made vsanni-1107222997.pdf
Entry  Wed Oct 31 08:33:54 2007, rana, Problem Fixed, SUS, Vent measurements 
Entry  Tue Nov 6 09:45:22 2007, steve, Summary, SUS, vent sus trend  ventsustrend.jpg
Entry  Tue Nov 6 15:37:34 2007, rob, Configuration, SUS, rampdown script 
Entry  Sun Nov 11 21:05:55 2007, rana, HowTo, SUS, MC Touching or not 
Entry  Mon Nov 26 10:17:31 2007, steve, Omnistructure, SUS, etmy sus damping restored etmyrms20d.jpgetmyrmseq.jpg
Entry  Wed Nov 28 17:15:26 2007, rana, Configuration, SUS, ETMY damping / watchdogs 
Entry  Fri Nov 30 19:29:14 2007, rana, Configuration, SUS, new screen 
Entry  Thu Dec 6 19:19:47 2007, Andrey, Configuration, SUS, Suspension damping Gain was restored 
Entry  Wed Dec 26 15:00:06 2007, rana, Update, SUS, ETMY tripping etm.png
    Reply  Wed Dec 26 15:12:48 2007, rana, Update, SUS, ETMY tripping 
    Reply  Thu Dec 27 13:08:04 2007, rana, Update, SUS, ETMY tripping Untitled.png
Entry  Thu Jan 3 08:53:55 2008, steve, Update, SUS, etmy vs etmx sus.jpg
Entry  Thu Jan 3 09:55:11 2008, steve, Update, SUS, etmy sus damping restored etmy12h.jpg
Entry  Fri Jan 4 08:42:03 2008, steve, Update, SUS, etmy trips again etmy20m.jpgetmy120s.jpgetmysenV.jpg
Entry  Mon Jan 7 09:01:39 2008, steve, Update, SUS, BS sus damping restored bssdl.jpg
Entry  Thu Jan 10 10:38:02 2008, steve, Update, SUS, etmy damping restored etmysus.jpgsustrend16d.jpg
Entry  Thu Jan 10 12:08:23 2008, steve, Update, SUS, why did the BS move? bshopped.jpg
Entry  Thu Jan 10 15:04:04 2008, steve, Update, SUS, illuminator light effect on BS position bssusilum.jpg
Entry  Mon Jan 14 14:41:09 2008, steve, Update, SUS, etmy sus damping restored & mz relocked etmysus&mzhvtrend.jpg
Entry  Wed Jan 16 18:24:41 2008, rana, Update, SUS, ETMY Watchdog A.pdf
ELOG V3.1.3-