  820   Mon Aug 11 00:58:31 2008 ranaUpdatePEM2 years of temperature trendThe PSL RMTEMP alarmed again because it says
the room temperature is 19.5 C. Steve said
in
 Untitled.png 
  821   Mon Aug 11 09:39:29 2008 ranaUpdatePEM2 years of temperature trendSteve and I went around and inspected and
then adjusted the thermostats and [FONT=Comic
Sans MS]humidostats[/FONT].
  
  867   Thu Aug 21 17:55:14 2008 ranaHowToIOOMC WFS DC OffsetsI ran the McWFS_dc_offsets script to trim
out the DC offsets on the MC WFS DC signals.
  
  868   Thu Aug 21 18:13:24 2008 ranaUpdateIOOMC WFS Control signals not responsible for lock lossesThis is a 4 hour, second-trend of the MC WFS
error and control signals.
 Untitled.png 
  881   Mon Aug 25 15:50:18 2008 ranaSummaryPEMRanger SS-1The manual for the Ranger SS-1 seismometer
can be found on line here:
[URL=ftp://ftp.kmi.com/pub/software_manuals/300190/300190nc.pdf]ftp://ftp.kmi.com/pub/software_manuals/300190/300190nc.pdf[/URL]
  
  883   Mon Aug 25 21:15:23 2008 ranaConfigurationLSCaux NPRO off[FONT=Comic Sans MS][COLOR=purple]Looks like
no one has used the Lightwave NPRO on the
AS table after Koji left, so I turned it
  
  884   Tue Aug 26 09:04:59 2008 ranaConfigurationPSLPMC Servo Board: Out for RepairsI've started modifying our PMC board to bring
it up to the 21st century - [B][COLOR=blue]leave
the screen alone[/COLOR][/B] or else you
  
  888   Tue Aug 26 18:19:16 2008 ranaOmnistructureElectronicsResistor Noise at the 40mAs Stefan points out in his recent ISS ilog
entries at LLO, Daniel [COLOR=darkgreen]Sigg
recently wrote a
 SEI-RN_RNM.pdf 
  893   Thu Aug 28 18:56:14 2008 ranaConfigurationPSLbeam block distortedThere was a beam block after the Mach Zender.
Who or what put this there?
  
  903   Fri Aug 29 17:39:25 2008 ranaConfigurationPSLPMC: ADC ChannelsThe attached PNG shows the PMC error and controls
signals with no calibration.
 mcf.png 
  904   Fri Aug 29 18:24:48 2008 ranaHowToPSLPMC: PZT CalibrationI calibrated the PMC PZT at DC by using 'trianglewave'
to drive the DC offset slider
and reading back PMC_PZT and PMC_TRANSPD_F
 pmc-pzt-cal.pdfmcf.png 
  906   Sat Aug 30 13:28:01 2008 ranaConfigurationPSLPMC: List of changesThis is a list of changes made to the PMC
board while we had it out for modifying the
notch:
  
  907   Mon Sep 1 04:34:00 2008 ranaUpdatePSLFSS loop transfer functionsI started from 6th item in Yoichi's todo list.

1) Increased the setpoint of the thermostat
 n.pdfFSSLO.PNGFSSLO-Spec.pngPC25.pngpc.pdf 
  909   Tue Sep 2 07:58:34 2008 ranaSummaryPSLFSS & PMC LO trends for 2 yearsThe attached plot is a 2 year minute trend
of the EPICS readback of the PMC & FSS LO
Monitors (FSS_LODET & PMC_LODET).
 psl-lo-trend.png 
  918   Thu Sep 4 00:38:14 2008 ranaUpdatePSLc1iovme power cycledEntry 663 has a plot of this using the PSL/FSS/SLOWscan
script. It shows that the SB's were ~8x smaller
than the carrier.
  
  925   Thu Sep 4 16:24:56 2008 ranaConfigurationComputersAttempt to increase gain for C1:PSL-ISS_INMONPD_F via 110B[quote]We were attempting to increase the
gain on the channel C1:PSL-ISS_INMONPD_F
in preparation to do a scan of the PMC at
  
  934   Fri Sep 5 15:09:50 2008 ranaUpdatePEMthermostate setting changed[quote]Some one changed the thermostat (old
control room ) setting behind 1Y6 from 73
to 79F
  
  967   Thu Sep 18 23:31:26 2008 ranaUpdatePSLISS: Saturating too often at nominal gainThe ISS has been saturating whenever the MC
relocks and puts the gain up to +8dB. I have
lowered the gain to +1 dB for now to stop
 FIRE_BLOWER.jpg 
  968   Fri Sep 19 00:06:54 2008 ranaUpdateIOOMC_F: Too much frequency noise around 100 HzWE noticed this excess again in MC_F. We tried
recentering the WFS, but no effect.
 mcf.png 
  969   Fri Sep 19 00:18:14 2008 ranaUpdateComputerssvn is old[CODE]linux2:mDV>ssh nodus
Password:
Last login: Fri Sep 19 00:11:44 2008 from
  
  970   Fri Sep 19 01:55:41 2008 ranaSummarySUSSUS Drift Screen UpdatedI wrote 2 matlab scripts to update the SUS
DRIFT screen:
 infection-3.pngsetsvals.msetHILO.m 
  976   Mon Sep 22 15:02:45 2008 ranaFrogsTreasureMantis found outside the 40m door at night   mantis.JPG 
  980   Mon Sep 22 21:30:06 2008 ranaConfigurationPSLbad FSSThe MC refl power was going up and the FSS
PC drive was so large that I had to turn
up the FSS
 DAQ.png 
  981   Mon Sep 22 21:54:05 2008 ranaUpdateASSNew Wiener result with x10 gain in ACCThe 2 attached PDF files show the performance
of the Wiener filter code on 2 hours of data
with a 4000 tap filter on 64 Hz data. All
 f.pdf 
  982   Mon Sep 22 22:24:19 2008 ranaConfigurationPSLbad FSS[quote]The MC refl power was going up and
the FSS PC drive was so large that I had
to turn up the FSS...[/quote]
  
  988   Wed Sep 24 19:13:06 2008 ranaConfigurationComputer Scripts / Programsupdatedb & locate: megatron & rosalbaI ran [I]updatedb[/I] as root today on megatron
and rosalba just before the meeting. 
It finished at ~14:10 on both machines so
  
  989   Thu Sep 25 02:35:21 2008 ranaSummaryPSLFAST is moving alotIt looks like the FAST signal has started
moving a lot - this is partly what inspired
us to tune the SLOW loop.
 Untitled.pngUntitled.png 
  990   Thu Sep 25 03:12:13 2008 ranaSummaryComputersconlog and linux1It would be nice to have conlog from outside.
Right now its on linux1 and so its unavailable.
To
  
  994   Thu Sep 25 17:14:31 2008 ranaConfigurationGeneralnew sitemap   vegemite.png 
  999   Fri Sep 26 16:13:57 2008 ranaUpdateIOOMC_L / MC_F crossoverWe were trying to understand why the FAST_F
signal had such large excursions (~1V ~ 5
MHz).
 mcx.png 
  1001   Fri Sep 26 19:08:43 2008 ranaConfigurationPSLRefcav Trans: PD + Camera + DumpsI went out to improve the Refcav trans path.

I removed all ND filters to get rid of the
  
  1003   Mon Sep 29 01:19:40 2008 ranaSummaryPSLLaser chiller running a little hotI looked at it some last night and my suspicion
was the ISS. Whenever the ISS switch came
on the FAST got a kick.
  
  1011   Wed Oct 1 00:24:54 2008 ranaUpdateLockinglast nightI had mistakenly left the MC boost off during
my FAST investigations. The script is now
restored.
  
  1012   Wed Oct 1 02:10:03 2008 ranaUpdateIOOMZ is going badHere's a 2 day trend of the MZ. You can see
that there is something bad with ERR - it
should really be going to zero.
 Untitled.pngUntitled.png 
  1013   Wed Oct 1 02:47:53 2008 ranaUpdatePSLPSL ERR & LODET: Too much offsetLooks like there is an anomolous mixer offset
correlated with the increase in the LO level.
This may be leading to crazy offset locking
 Untitled.png 
  1021   Thu Oct 2 18:56:19 2008 ranaSummarySUSResistivity of Suspension WireBob and Steve measured the resistance of the
suspension wire today:
  
  1049   Wed Oct 15 17:40:50 2008 ranaUpdatePSLPMC Offset adjustedI set the PMC servo input offset: closed the
MOPA shutter, zeroed the mixer output with
the offset slider, 
  
  1064   Tue Oct 21 17:52:30 2008 ranaSummaryPSLFSS Photo: early OctoberThis is a photo of the FSS board before Yoichi
did his surgery - it was taken with the D40
in macro mode, sitting on the big Gorilla
 fss.jpg 
  1088   Fri Oct 24 20:54:41 2008 ranaConfigurationComputerslinux2I have removed linux2 and its cables from
the control room and put it into 1Y3 along
with op340m.
  
  1091   Sun Oct 26 21:02:18 2008 ranaUpdateComputer Scripts / ProgramsSVN medm problemAs we've seen in the past a few times, there's
something wrong with the files in the [I]trunk/medm[/I]
area.
  
  1104   Sun Nov 2 20:21:58 2008 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegraI set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  1105   Sun Nov 2 20:44:58 2008 ranaUpdateASSWiener Filter performance over 5 hoursI took one 2 hour stretch of data to calculate
a MISO Wiener filter to subtract the Ranger
seismometer
 f.pngf1.png 
  1106   Sun Nov 2 21:37:22 2008 ranaUpdatePEMRanger recoveryThe ranger signal has been bad since around
11 AM on Oct 25 (last Saturday). There are
no elog
  
  1111   Mon Nov 3 22:35:40 2008 ranaUpdateASSWiener Filter performance over 5 hours[FONT=Comic Sans MS]To speed up the Wiener
filter work I defined a 256 Hz version of
the original 16kHz IOO-MC_L signal. The
 DAQ.pdf 
  1112   Tue Nov 4 00:47:53 2008 ranaUpdateASSWiener Filter performance over 5 hoursSame as before, but now with a working Ranger
seismometer.
 f2.pngf.png 
  1113   Tue Nov 4 01:03:01 2008 ranaSummaryPEMperiodic thump noise in MC1_ACC[B]There seems to be a periodic thump seen
by the MC1 Accelerometers as well as the
surrounding optics.[/B]
 Untitled.pngUntitled2.png 
  1119   Thu Nov 6 22:07:56 2008 ranaConfigurationComputersELOG compile on SolarisFrom the ELOG web pages:

Solaris:
  
  1122   Fri Nov 7 15:58:10 2008 ranaUpdatePEMAC is back onI'll bet Steve a dollar that it is mechanical.
The attached PDF compares all of the accelerometers
from right now.
 mc-acc.pdfmc-acc-quad.pdf 
  1137   Fri Nov 14 20:35:47 2008 ranaUpdatePSLReference cavity ring downTo make the DEI pulser make a fast pulse on
the EO shutter EOMs, we had to make sure:
  
  1147   Wed Nov 19 18:02:18 2008 ranaConfigurationElectronicsAll the Marconi Set to the Rubidium Frequency StandardNot sure what was going on before. I changed
the frequency counter to use an AC coupled
input, and had it average
  