40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 281 of 339  Not logged in ELOG logo
ID Date Author Typeup Category Subject Text Attachments
  13339   Thu Sep 28 10:33:46 2017 gautamUpdateCDS40m files backup situationAfter consulting with Jamie, we reached
the conclusion that the reason why the root
of FB1 is so huge is because of the way the
  
  13340   Thu Sep 28 11:13:32 2017 jamieUpdateCDS40m files backup situation 




  
  13342   Thu Sep 28 23:47:38 2017 gautamUpdateCDS40m files backup situationThe nodus
backup too is now complete - however,
  
  13343   Thu Sep 28 23:50:04 2017 gautamUpdateLSCDAC noise measurement (again)I
am running some more measurements of the
DAC noise, for which I've shut down
  
  13345   Fri Sep 29 11:07:16 2017 gautamUpdateCDS40m files backup situationThe FB1   
  13346   Fri Sep 29 11:16:52 2017 SteveUpdateALSY End table correctedThe first Faraday isolater rejected beam
path from the NPRO is fixed.

 
 ETMYf1.jpg 
  13347   Fri Sep 29 18:36:25 2017 gautamUpdateLSCDAC noise measurement (again)BS connections and damping restored.




  
  13348   Mon Oct 2 12:44:45 2017 johannesUpdateCamerasBasler 120gm calibrationDisclaimer: Wrong calibration
factors! See 
 calib_20170930_152.pdfcalib_20170930_153.pdf 
  13349   Mon Oct 2 18:08:10 2017 gautamUpdateCDSc1ioo DC errorsI was trying to set up a DAC channel to
interface with the AOM driver on the PSL
table.
 c1ioo_CDS_errors.png 
  13350   Mon Oct 2 18:50:55 2017 jamieUpdateCDSc1ioo DC errors


  
  13351   Mon Oct 2 19:03:49 2017 gautamUpdateCDS[Solved] c1ioo DC errorsThis did the trick - I simply ran

sudo
 CDSoverview.png 
  13353   Tue Oct 3 01:32:39 2017 gautamUpdateLSCLaser intensity noise coupling to MICH (simulated)GV Oct 6: This
coupling is probably not correct - Finesse
 MICH_intensityNoiseCoupling.pdfMICH_intensityNoiseASD.pdf 
  13355   Tue Oct 3 19:39:10 2017 gautamUpdateCDSslow machine bootfestEurocrate key turning reboots for c1susaux,   
  13356   Wed Oct 4 17:18:15 2017 gautamUpdateCDSFree DAC channels in c1lscThere are at least 5 free DAC channels
(4 if you discount the one channel from these
that I am hijacking) available in the 1Y2
  
  13357   Wed Oct 4 17:38:25 2017 gautamUpdateLSCFS725 for Marconi stabilizationI've located the Stanford Research
FS725 Rb reference unit. The question is
where to put it. This afternoon Steve and
  
  13359   Thu Oct 5 02:14:51 2017 gautamUpdateLSCMore DRMI coupling measurements - setupIn the end I decided to access the available
spare DAC channels via the C1ASS
 CB4709D0-3FA7-43E3-BC25-3CF4164E6C6A.jpeg 
  13360   Thu Oct 5 11:46:15 2017 gautamUpdateCDSslow machine bootfestMC Autolocker was umnhappy because c1iool0   
  13361   Thu Oct 5 13:58:26 2017 gautamUpdateCDS40m files backup situationThe 4TB HGST drives have arrived. I've
started the FB1 dd
  
  13362   Thu Oct 5 18:40:27 2017 gautamUpdateLSCFS725 for Marconi stabilization[steve, gautam]


We installed the FS725
on the shelf inside the PSL enclosure - see
 IMG_7617.JPGIMG_7619.JPGIMG_7618.JPG 
  13363   Fri Oct 6 00:25:45 2017 ranaUpdateLSCFS725 for Marconi stabilizationSteve,
can you please connect this fan to the rack
  
  13364   Fri Oct 6 12:46:17 2017 gautamUpdateCDS40m files backup situationLooks to have worked this time around.

  
  13366   Fri Oct 6 17:08:09 2017 SteveUpdateALSX End table beam traps correctedThere are no more double sided tape on
this table.

 
 c1.jpgc2.jpgc3.jpgc4.jpg 
  13367   Mon Oct 9 01:29:26 2017 gautamUpdateLSCDRMI Nosie Budget v3.0Summary:

I
spent this weekend doing a more careful investigation
of the DRMI noise.
 7x 
  13368   Mon Oct 9 11:55:01 2017 KojiUpdateLSCDRMI Nosie Budget v3.0My last characterization of the AS55 PD
was on Feb 2013. ELOG
8100
  
  13369   Mon Oct 9 22:18:34 2017 gautamUpdateLSCAS55Q Dark NoiseI measured the output voltage noise of
the Q output of the AS55 Demod Board with
the PSL shutter closed, using the SR785 (see
 AS55Q_dark.pdf 
  13370   Tue Oct 10 22:04:06 2017 ranaUpdateLSCAS55Q Dark Noisehow about calibrate the DC channels so
that you can just get the acutal power levels
from the trend data?
  
  13371   Wed Oct 11 10:29:43 2017 SteveUpdateElectronicsSR560 noise levelGautam and Steve,

All 3 show the same noise level
~80 nV / rt Hz at 1 kHz as shown. Batteries
 sr560.jpgsr560noise.jpg 
  13372   Wed Oct 11 14:42:03 2017 gautamUpdateLSCAS55Q Dark NoiseI keep adding traces to this plot, here
is the most complete one I have now. Looks
like the input noise to the D040179 (measured
 AS55Q_darkNoises.pdf 
  13373   Wed Oct 11 17:59:45 2017 ranaUpdateElectronicsSR560 noise levelthese are not the SR785 settings that you're
looking for

  
  13374   Wed Oct 11 19:31:32 2017 gautamUpdateLSCAS55Q Dark NoiseI tried replacing the AD797s on the daughter
board with OP27s, and saw no significant
improvement in the electronics noise of the
 AS55Q_darkNoises.pdf 
  13376   Thu Oct 12 01:50:11 2017 gautamUpdateLSCAS55Q Dark NoiseI worked on the daughter board a little
more in the evening. I have somehow managed
to make the dark noise ~25% worse [Attachment
 AS55_dark.png 
  13378   Thu Oct 12 12:17:28 2017 gautamUpdateLSCAS55Q Dark NoiseHere is the marked up schematic with the
board as it is stuffed. Annoyingly, there
is a capacitor (C1) which according to the
 D040179_AS55_40m.pdf 
  13379   Thu Oct 12 14:42:45 2017 gautamUpdateCDSslow machine bootfestSteve reported problems getting the X arm
locked. Alignment sliders were inaccessible.
Eurocrate key turning reboots for 
  
  13380   Fri Oct 13 12:26:12 2017 gautamUpdateLSCAS55Q Dark NoiseAttachment #1 -
Measured / modelled noises for AS55 demod
board. I've plotted quadrature sum of
 AS55_DemodNoises.pdf 
  13381   Mon Oct 16 12:13:38 2017 gautamUpdateCDSMegatron maintenanceWall StripTool traces showed that IMC has
not been locked for at least 8 hours when
I came in this morning. Going to the IMC
  
  13382   Mon Oct 16 16:01:04 2017 gautamUpdateLSCAS55Q Dark NoiseKoji suggested looking at the output of
the AS55 demod board on a fast oscilloscope
to look for differences in the two channel
 DemodBoardwOscope.pdfDemodBoardwOscope_ASD.pdf 
  13384   Tue Oct 17 19:31:53 2017 gautamUpdateLSCAS55Q Dark Noise[Koji, gautam]

We took a closer look at the AS55
demod board today. The procedure was to just
 D040179_TFs.pdfAS55_DemodNoises.pdf 
  13385   Tue Oct 17 23:07:52 2017 gautamUpdateCDSFEs unresponsiveWhile working on the IFO tonight, I noticed
that the blinky status lights on c1iscex
and c1iscey were frozen (but those on the
  
  13386   Wed Oct 18 01:41:32 2017 jamieUpdateCDSFEs unresponsive


  
  13387   Wed Oct 18 02:09:32 2017 gautamUpdateCDSFEs unresponsiveI was looking at the ASDC channel on dataviewer,
and toggling various settings like whitening
gain. At some point, the signal just froze.
  
  13388   Wed Oct 18 09:21:22 2017 jamieUpdateCDSFEs unresponsive


  
  13392   Wed Oct 18 17:34:09 2017 gautamUpdateSUSASDCSummary:

The signal path for the ASDC signal
is AS55
  
  13393   Wed Oct 18 19:17:42 2017 gautamUpdateGeneralPRC angular feedforwardLast night, I collected ~30mins of data
for the vertex seismometer channels and the
POP QPD PIT/YAW signals with the PRMI locked
 pop_feedforward_potential.pdf 
  13394   Wed Oct 18 23:11:53 2017 gautamUpdateCDSFEs unresponsiveThis happened again just now - it was roughly
this time when this happened last night as
well.
  
  13396   Fri Oct 20 16:30:17 2017 gautamUpdateCDSFB1 installed on shelves[steve, jamie, gautam]

The machine that now serves as
out Frame Builder, FB1, was sitting on top
  
  13397   Mon Oct 23 09:17:41 2017 SteveUpdatePEMants alartDo not leave organic trash or food boxes
in the 40m to attrack ants !
 ants.jpgants2.jpg 
  13398   Tue Oct 24 16:22:53 2017 gautamUpdateCDSToy DARM model setup in c1tst[alex, gautam]

Alex is going to have an undergrad
work on a calibration optimization project
 TOY_DARM.pngTOY_DARM_SIMULINK.png 
  13399   Tue Oct 24 16:43:11 2017 SteveUpdateCDSslow machine bootfest[ Gautam , Steve ]

c1susaux
  
  13402   Fri Oct 27 09:34:20 2017 SteveUpdatePEMearthquakesLompoc 4.3M and 3.7M Avalon

 
 recentEQs.png 
  13403   Fri Oct 27 10:14:11 2017 SteveUpdateVACRGA scan at day 372Valve configuration: Vacuum normal

Note: Tp2 running at 75Krpm 0.25A
26C has a  load high pitch sound today.
 RGA_scan_d372.png 
ELOG V3.1.3-