40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 27 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  17106   Thu Aug 25 16:39:31 2022 CiciUpdateGeneralI have learned the absolute basics of githubI have now added code/data to my github
repository. (it's the little victories)
  
  17107   Fri Aug 26 12:46:07 2022 CiciUpdateGeneralProgress on fitting PZT resonancesHere is an update of how fitting the resonances
is going - I've been modifying parameters
by hand and seeing the effect on the fit.
 PZT_fit.zipAUX_PZT_Actuator_narrow_fit_1.pdf 
  17112   Mon Aug 29 18:25:12 2022 CiciUpdateGeneralTaking finer measurements of the actuator transfer functionTook finer measurements of the x-arm aux
laser actuator tranfer function (10 kHz -
1 MHz, 1024 pts/decade) using the Moku.
 PZT_TF_fine.pngPZT_TF_fine_mag_stdev.pngATF_fine.zip 
  16993   Tue Jul 12 18:35:31 2022 Cici HannaSummaryGeneralFinding Zeros/Poles With VectfitAm still working on using vectfit to find
my zeros/poles of a transfer function - now
have a more specific project in mind, which
  
  17006   Fri Jul 15 16:20:16 2022 Cici HannaUpdateGeneralFinding UGFI have temporarily abandoned vectfit and
aaa since I've been pretty unsuccessful
with them and I don't need poles/zeroes
 UGF_4042.pngUGF_5650.pngTFSR785_29-06-2022_114042.txtTFSR785_29-06-2022_115650.txt 
  1692   Tue Jun 23 23:14:36 2009 ClaraConfigurationPEMAccelerometers relocatedBoth accelerometers have been moved in
an attempt to optimize their positions. The
MC1 accelerometer was moved from one green
  
  1696   Wed Jun 24 12:04:00 2009 ClaraUpdatePEMaccelerometer clarificationWhen I said "MC1/MC2 accelerometers,"
I meant the entire three-axis accelerometer
set at each point.
  
  1698   Wed Jun 24 12:09:24 2009 ClaraUpdatePEMWeek 1(ish)I spent the week reading up on filter algorithm
theory, particularly Wiener filtering. I
have also learned how to get data from specific
  
  1703   Thu Jun 25 21:00:30 2009 ClaraUpdatePEMMC1 Accelerator set moved again; new XLR cablesI moved the MC1 set of accelerators. Might
have bumped things. If things aren't working,
look around the MC1 chamber.
  
  1704   Fri Jun 26 15:22:28 2009 ClaraUpdatePEMXLR cables tested and labeledWe now have two 80-foot, female-to-female
XLR cables for our pretty new microphones,
one yellow and one purple. They have been
 NC3FXX-EMC.pdfCat11_p35.pdf 
  1707   Sat Jun 27 02:48:09 2009 ClaraUpdatePEMI moved accelerometers and made some pretty picturesI have been working on finding the best
spots to put the accelerometer sets in order
to best subtract out noise (seismometers
 6x 
  1708   Sat Jun 27 03:16:16 2009 ClaraUpdatePEMExciting microphone things!So, I'm double-posting, but I figured the
last post was long enough as it was, and
this is about something different. After
 mic_voltage_out.pngvoltage_dividers.pngvoltage_divider_sketch.png 
  1713   Thu Jul 2 05:27:12 2009 ClaraUpdatePEMVoltage Divider OopsI tested the voltage dividers and was getting
up to about 3V. I retested the mic w/o the
voltage divider in place, and, lo and behold,
 voltage_divider_diagram.png 
  1714   Thu Jul 2 06:31:35 2009 ClaraUpdatePEMFirst mic in place and connectedI clamped Bonnie (microphone) to the top
of a chamber near the vertex of the arms
and placed Clyde (pre-amp) on the table right
 bonnieandclyde.JPG 
  1715   Thu Jul 2 16:45:06 2009 ClaraUpdatePEMBonnie and Clyde are officially in operation! (Butch Cassidy and the Sundance Kid are in temp position)I hooked up Bonnie and Clyde last night
and tested it today. First I tried some loud
noises to make sure I could identify them
 bonnie_test_marked.pngbonnie_test2_marked.pngbonniebutch_2sbeat_marked.png 
  1718   Tue Jul 7 16:06:59 2009 ClaraUpdateComputer Scripts / ProgramsDTT synchronization errors, help would be appreciatedI am attempting to use the DTT program
to look at the coherence of the individual
accelerometer signals with the MC_L signal.
  
  1723   Wed Jul 8 12:36:15 2009 ClaraUpdatePEMCoherences and thingsAfter setting up the microphones last week,
I modified the Wiener filtering programs
so as to include the microphone signals.
 7x 
  1726   Wed Jul 8 19:42:37 2009 ClaraUpdatePEMBonnie moved to PSL, getting some coherence with the PMC_ERR channelIn her position overlooking whichever table
it is that is next to the PSL, Bonnie drummed
up some decent coherence with the PSL-PMC_ERR
 DSC_0567.JPGbonnie2_pmcerr.pdfbonnie_PSL.pdf 
  1728   Thu Jul 9 19:05:32 2009 ClaraUpdatePEMmore mic position changes; mics not picking up high frequenciesBonnie has been strung up on bungees in
the PSL so that her position/orientation
can be adjusted however we like. She is now
 6x 
  1744   Tue Jul 14 16:31:46 2009 ClaraUpdatePEMFrequency Response of Microphone (Bonnie)So, I actually took these measurements
last week, but I didn't get around to making
nice plots and things until now. I figured
 Bonnie_fres_regplot.pdfBonnie_fres_logplot.pdf 
  1757   Thu Jul 16 10:52:58 2009 ClaraUpdatePEMSingle Channel TRS-RNC CableI made and tested a female-to-female TRS(audio)-RNC
cable. It only has a single channel, so it
won't work for stereo speakers or anything,
  
  1760   Fri Jul 17 18:04:54 2009 ClaraUpdatePEMGuralp Box FailI've been trying for most of the week to
get noise measurements on the output of the
Guralp box as well as scross the AD640 chip.
 VERT2_missing_resistors.pngresistors_diagram.pngresistors_board.png 
  1767   Tue Jul 21 13:55:08 2009 ClaraUpdatePEMGuralp Box Success!There managed to be just enough 100 kOhm
resistors to stuff all the "2"
channels (VERT2, N/S2, E/W2) with the fancy
  
  1800   Tue Jul 28 16:03:14 2009 ClaraUpdatePEMGuralp Seismometer cable pin diagramI mapped out the corresponding pins on
both ends of the Guralp seismometer cable.
Here is the diagram:
 guralp_pin_diagram.png 
  1806   Wed Jul 29 13:15:35 2009 ClaraUpdatePEMDents = Bad??I was in the lab last night accelerometerizing
and noticed some dents on the tubes that
stick out horizontally from the MC2 optical
 small_dent.pngbig_dent1.pngbig_dent2.png 
  1859   Fri Aug 7 16:53:35 2009 ClaraUpdatePEMGuralp breakout box noise, finallyAfter many issues, I finally have some
Guralp box noise. I did not measure every
single channel with high resolution at the
 output_vallwr2_ns3_1.pngtp3gnd_vallwr2_ns3.png 
  1885   Tue Aug 11 02:15:20 2009 ClaraUpdatePEMGuralp breakout box circuit diagramWhile writing my progress report, I redrew
the Guralp breakout box circuit diagram with
all the changes marked. Since only one hard
 Guralp_circuit_whole.pngGuralp_circuit_broken.png 
  1900   Fri Aug 14 02:57:46 2009 ClaraUpdatePEMRedo of the Huddle TestI put all three seismometers and all six
accelerometers together in the foam box with
peanuts. Three of the accelerometers are
  
  1907   Fri Aug 14 18:33:02 2009 ClaraUpdate Record of Accelerometer and Seismometer MovementsRather than make a new elog post every
time I move something, I'm going to just
keep updating this Google spreadsheet, which
  
  1911   Sat Aug 15 18:35:14 2009 ClaraFrogsComputersHow far back is complete data really saved? (or, is the cake a lie?)I was told that, as of last weekend, we
now have the capability to save full data
for a month, whereas before it was something
  
  1913   Sat Aug 15 22:50:18 2009 ClaraUpdateLockingMode Cleaner is out of lock againIt was fine when I came in earlier today,
but I just got back from dinner, and it's
not good. I looked in dataviewer, and it
 MC_trans.png 
  1914   Sun Aug 16 04:33:11 2009 ClaraUpdateLockingMode Cleaner is out of lock again


   
        
            
  
  1918   Mon Aug 17 07:01:09 2009 ClaraUpdatePEMADC noisenessI shorted the inputs on three channels
and the outputs on three channels of the
Guralp box, and I did similar things with
  
  1866   Fri Aug 7 20:43:35 2009 Clara, Jenne, Rana, JanUpdatePEMTwo Guralps plugged in, prepped for huddle testBoth Guralps and the Ranger have been placed
in our nice new insulated foam box, complete
with packing peanuts, in the corner between
 Untitled.png 
  12750   Tue Jan 24 17:52:15 2017 CraigUpdateOptical LeversETMY Oplev HeNe is replacedSteve, Craig, Gautam

Today Steve replaced the ETMY He/Ne
sr P919645 OpLev laser with sr P947049 and
 6x 
  12842   Tue Feb 21 13:51:35 2017 CraigSummaryGeneralAlternative Calibration SchemeWe get SNR in two ways: the amplitude of
applied force and the integration time. 
So we are limited in two ways: stability
  
  7560   Tue Oct 16 17:13:23 2012 CzarinaSummaryGeneralvent stuff - 4 pathsI see 4+
possible paths for us to take, in terms of
a possible vent in the next few weeks:
  
  9855   Fri Apr 25 13:18:08 2014 Dark JamieUpdateLSClocking activity

    

       
            
 m10008_f1_bg.jpg 
  16897   Tue Jun 7 18:32:46 2022 DeekshaUpdateElectronicsNoise Budgeting ADC (of redpitaya)Made plots on i/p noise of redpitaya .
Need to reconsider sampling frequency (to
improve plot at lower freq)
 ch1_0.5V.pngch2_0.0V.png 
  16939   Wed Jun 22 17:04:06 2022 DeekshaSummaryElectronicsCharacterising the AUX control loop[Cici, Deekha]

Setup loop to measure transfer
function of control loop - the aim is
 after.jpegbefore.jpegfreq_response.png 
  16951   Mon Jun 27 13:39:40 2022 DeekshaUpdateElectronicsSetting up the MokuLab[Cici, Deeksha]

On Friday Cici and I set up the
Mokulab to take readings of our loop. The
 WhatsApp_Image_2022-06-24_at_5.21.28_PM.jpeg 
  16964   Thu Jun 30 17:19:55 2022 DeekshaSummaryElectronicsMeasured Transfer Functions of the Control Loop, Servo (OLTF); got Vectfit working [Cici, Deeksha]

We were able to greatly improve
the quality of our readings by changing the
 TFSR785_29-06-2022_114042.pdfTFSR785_29-06-2022_114650.pdfTF_OLG_vectfit.png 
  16974   Wed Jul 6 18:51:20 2022 DeekshaUpdateElectronicsMeasuring the Transfer Function of the PZTYesterday, we set up the loop to measure
the PZT of the transfer function - the MokuLab
sends an excitation (note - a swept sine
 pzt_transfer_fn.pngckt_diagram.jpegMokuPhaseMeterTFData_20220706_174753_TF_Data.txt 
  17031   Mon Jul 25 09:37:39 2022 DeekshaUpdateElectronicsUsing the DFD to measure PZT TFThe DFD was setup to measure the change
in beatnote when excited. A long long (128in)
cable goes from the SR785 near the DFD all
 ag4395.jpegdfd.jpeg 
  17035   Mon Jul 25 18:22:30 2022 DeekshaSummaryWikiMeasured the PZT TF Successfully Measured the PZT beatnote using the setup
mentioned in elog post 17031. Attached is
the data taken from 10kHz to 1MHz, decadewise
 6x 
  17036   Tue Jul 26 19:50:25 2022 DeekshaUpdateComputer Scripts / ProgramsVector fittingTrying to vectfit to the data taken from
the DFD previously but failing horribly.
I will update this post as soon as I get
 data.pngfit_attempt.png 
  17039   Wed Jul 27 14:39:04 2022 DeekshaUpdateElectronicsNew and improved PZT TF data from the DFDPaco and I messed around with the attenuation
of the scope and bandwidth of the IF. We
also replaced the BNC T's in the
 tf_data.pnglatest_data.zipdfd_-_new.drawio.png 
  5573   Thu Sep 29 00:16:35 2011 DenUpdateComputersSegmentation fault fixed.The OAF c-code crashed because of the segmentation
fault. We've created arrays of static variables
  
  5740   Tue Oct 25 21:49:13 2011 DenUpdateAdaptive FilteringAdaptive filter witness and EP SNR

    
      
 gur1_x.jpggur1_y.jpggur1_z.jpg 
  5777   Tue Nov 1 18:16:50 2011 DenUpdateAdaptive FilteringAdaptive filter witness and EP SNR

    

       
            
 translation_length.jpgtrans_tilt.jpgseismic_length.jpgfiltering.jpgtilt_filtering.jpg 
ELOG V3.1.3-