  1147   Wed Nov 19 18:02:18 2008 ranaConfigurationElectronicsAll the Marconi Set to the Rubidium Frequency StandardNot sure what was going on before. I changed
the frequency counter to use an AC coupled
input, and had it average
  
  1148   Wed Nov 19 18:12:35 2008 ranaConfigurationIOOnew channel for MC drum modesI set up the lockin to take the MC Demod Board's
Qmon signal, demodulate it at 27.5 kHz, and
put the output into a DAQ channel (I think
  
  1150   Fri Nov 21 16:03:50 2008 ranaHowToGeneralRecharging BatteriesI found some black & red "Ninja" alkaline
AA batteries in the battery charger. [COLOR=red]This
is dangerous.[/COLOR] Please
  
  1154   Fri Nov 21 19:47:26 2008 ranaUpdatePEMGuralp noise measurementand here's the spectra with them connected
- from the coherences, it looks like it needs
to be rotated by 90 deg.
 a.png 
  1156   Fri Nov 21 21:20:24 2008 ranaUpdatePEMGuralp noise measurementThis is the spectra and time series of the
Guralp channels along with the Ranger (MC2).
Looks like we could reduce the gain
 a.png 
  1157   Fri Nov 21 21:28:32 2008 ranaSummaryComputersc0daqawg restart[COLOR=green]A few minutes after restarting
fb0 for the Guralp channels, the DAQAWG lights
went red on the DAQ screens.[/COLOR]
  
  1159   Mon Nov 24 16:43:34 2008 ranaConfigurationComputersAlex and Jay took away some computers from the racksI was over at Wilson house and saw Jay and
Alex bring in 3 rackmount computers. One
was a Sun 4600 and
  
  1160   Mon Nov 24 17:14:44 2008 ranaUpdatePSLMach Zender trendsIt looks like the MZ has gotten less drifty
after the alignment on Friday.
 Untitled.png 
  1164   Thu Nov 27 22:56:42 2008 ranaConfigurationEnvironmenttemperature8-)  mc.png 
  1167   Tue Dec 2 19:18:10 2008 ranaSummaryPEMRanger SS-1In entry http://dziban.ligo.caltech.edu:40/40m/881
and a follow up from Jenne I put in the Ranger
calibration.
  
  1168   Tue Dec 2 19:51:32 2008 ranaUpdatePEMhalf-micron particle count is alarmingThe 0.5 micron dust monitor count is now pretty
high (36000). I wandered around the lab to
see if there was anything
 Untitled.pngdust.png 
  1171   Wed Dec 3 19:21:09 2008 ranaConfigurationPEMRanger moveI looked at the Ranger signals. [B]Somehow
it has a relative transfer function of 'f'
between it and the Guralp.[/B]
 c.pdfwsnb.pdf 
  1179   Fri Dec 5 09:29:59 2008 ranaUpdateIOOdrum modes observable without excitationNot sure what the y-scale is since there aren't
any y axis labels in the plot, but it seems
like we
  
  1180   Fri Dec 5 14:13:41 2008 ranaSummaryIOOMC trend for the last 4 days[COLOR=pink][SIZE=2][FONT=Comic Sans MS]The
MC has stayed locked for ~3 days! I just
broke it to reset the MZ.[/FONT][/SIZE][/COLOR]
 g.png 
  1183   Sun Dec 7 16:02:46 2008 ranaUpdateGeneralMag 5.1 EQ halfway to VegasThere was a [URL=http://earthquake.usgs.gov/eqcenter/recenteqsww/Quakes/ci14408052.php#details]Mag
5.1 EQ[/URL] Friday night at 8:18 PM.
 g.pngUntitled.png 
  1184   Sun Dec 7 16:12:53 2008 ranaUpdateDAQbooted awg[SIZE=3]because it was [COLOR=red]red[/COLOR][/SIZE]   
  1213   Fri Jan 2 17:20:44 2009 ranaSummaryComputer Scripts / Programs40m GWINCI have made a '40m' directory in the iscmodeling
CVS tree which allows one to run a 40m version
of GWINC.
 bench40.pdf 
  1217   Thu Jan 8 16:49:37 2009 ranaConfigurationloreHP 5550dtn (Grazia) set up on allegra[quote]I set up printing to grazia from allegra.
The CUPS interface was not as straightforward
as Tobin had made it seem in the Wiki. I
  
  1230   Thu Jan 15 22:30:32 2009 ranaConfigurationDMFDMF start scriptI tried to restart the DMF using the start_all
script: http://dziban.ligo.caltech.edu:40/40m/280
  
  1239   Mon Jan 19 18:21:41 2009 ranaUpdateComputersloadLIGOData a GUI for mDVThe tool is very nice; I looked at the seismic
trend for 16 days (attached). 
However, it gives some kind of error when
 a.png 
  1242   Wed Jan 21 22:53:08 2009 ranaUpdateLSCAS CCD centering and ASDD demod phaseJust my opinion, but I think all we want out
of the DD signals is something to control
the DRM
  
  1297   Thu Feb 12 14:39:07 2009 ranaSummaryGeneralSilicon Beam Dump testYesterday evening, Ken Mailand and I tested
the reflectivity of a piece of polished Silicon.
Since Silicon has such a high thermalconductivity
  
  1307   Mon Feb 16 00:43:46 2009 ranaUpdateComputersmedm directory wiped on nodus[COLOR=red][B]I accidentally did an 'rm -rf'
on the medm directory in nodus[/B][/COLOR],
instead of on my laptop as was intended.
  
  1312   Mon Feb 16 20:47:48 2009 ranaConfigurationIOOMode Cleaner WFS Loop Gain changeI found the MCWFS gain slider down at 0.012.
In this state the UGFs are probably around
10-30 mHz
 pmc-pzt-cal.pdfa.pdfolg.pdfmc2.pdf 
  1315   Mon Feb 16 23:09:52 2009 ranaUpdateElectronicsMC Servo Board offset gone bad!The attached plot shows that someone broke
the MC_SUM_MON channel around 10:30 AM this
past Wednesday the 11th. This is the EPICS
 mcoff.png 
  1320   Wed Feb 18 19:13:20 2009 ranaConfigurationComputersSVN & MEDM & old medm filesAllegra had a 2 year old version of SVN installed
and CentOS (yum) couldn't upgrade it, so
I did an 'svn remove subversion'
  
  1321   Wed Feb 18 21:03:22 2009 ranaUpdateCamerasETMY Camera work not elogged!The control room video is showing us a
false ETMY image. Who worked on the ETMY
camera or video today??!!
  
  1322   Wed Feb 18 21:10:21 2009 ranaUpdateIOOMC Drumhead mode lost againIn early December, Caryn and I noticed that
the MC Drumhead mode was visible at the Qmon
point of
  
  1357   Wed Mar 4 23:42:45 2009 ranaConfigurationPSLpsl db changeI made   
  1360   Thu Mar 5 02:24:19 2009 ranaConfigurationComputersyum.repos.dI added the following repos which
I found on allegra to megatron and then did
a 'yum install sshfs' on both machines:
  
  1370   Sun Mar 8 23:09:26 2009 ranaUpdateComputersNot even data retrieval workingAlthough getting the regular DAQ data works,
we can't get any testpoints.
  
  1371   Sun Mar 8 23:14:52 2009 ranaUpdateComputer Scripts / Programstdsdata doesn't workMatt logged in and rebuilt the
TDS stuff for us on Mafalda in /cvs/cds/caltech/apps/linux/tds_090304.
  
  1378   Mon Mar 9 19:27:16 2009 ranaConfigurationComputersMove of the CLIO Digital Controls test setupBecause of the network interference
we've had from the CLIO system for the past
3-4 days, I asked the guys to remove
  
  1379   Mon Mar 9 19:33:10 2009 ranaUpdateDMFseisBLRMS in temp conditionThe seisBLRMS has been running on megatron
via an open terminal ssh'd into there from
allegra with matlab running. This
 Untitled.png 
  1383   Wed Mar 11 01:16:40 2009 ranaSummaryIOOrogue trianglewave in the MC Servo offset sliderOn Monday
evening, I ran this command: trianglewave
C1:IOO-MC_REFL_OFFSET 0 4 120 600;ezcawrite
 Untitled.pngUntitled.pnga.png 
  1384   Wed Mar 11 04:33:57 2009 ranaConfigurationComputer Scripts / Programswild ndsproxy tclshexeThe ndsproxy tcl task on nodus was eating
up all the CPU and making the elog slow.
I killed it and restarted it.
  
  1397   Thu Mar 12 19:11:27 2009 ranaUpdateIOOMC drift is terribleKakeru, Rana, Yoichi

We used the [SIZE=4][COLOR=purple][B]SUS
  
  1405   Mon Mar 16 01:20:40 2009 ranaConfigurationIOOMCWFS noise filtered on the SUS-MC [SIZE=4][COLOR=darkgreen]Recently[/COLOR][/SIZE],
we noticed that the IOO-WFS system runs at
2048 Hz and sends its signals to the MC SUS
 xarm.png 
  1415   Sun Mar 22 22:39:24 2009 ranaSummaryLSCCalibration of the ITM and ETM ActuationI used the following procedure to calibrate
the ITMX actuation signal.
 free.png 
  1416   Sun Mar 22 22:47:58 2009 ranaUpdateDMFseisBLRMS compiled but still dyingLooks like seisBLRMS was restarted ~1 AM Friday
morning but only lasted for 5 hours. I just
restarted it on megatron;
  
  1417   Sun Mar 22 23:16:41 2009 ranaDAQComputer Scripts / Programstpman restartCould get testpoints but couldn't start excitations.
Restarted tpman on daqawg. Works now.
  
  1418   Mon Mar 23 15:50:44 2009 ranaConfigurationLSCfilters deleted, lsc rebootedThe LSC time had gone too high. I deleted
~20 filters and rebooted. CPU time came down
to 50 usec.
  
  1424   Tue Mar 24 23:23:05 2009 ranaUpdateLSCNew PO DCWe also found that the SPOB RF cable was going
through a splitter before going into the
SPOB demod board. The other
  
  1441   Mon Mar 30 09:07:22 2009 ranaUpdateSUSMC1 drift investigation continued[COLOR=chocolate]Maybe we can temporarily
just disconnect the bias and just use the
SUS sliders for bias if there's enough range?[/COLOR]
  
  1456   Mon Apr 6 21:50:43 2009 ranaUpdateLSCArm Locking via pushing MC2Inspired by our 'No Refcav' scheme here, I
was inspired to re-explore the idea of locking
the
 mc2-xarm.pdfUntitled.pngnohands.pdf 
  1460   Wed Apr 8 18:18:33 2009 ranaConfigurationComputersLSC code recompiled with a fix for denormalization problemBelow is the link to the anti-denormalization
technique that Rolf and Alex implemented
at the sites,
  
  1461   Wed Apr 8 18:46:50 2009 ranaConfigurationGeneralDMF, SVN, x2mc, and matlabWhile waiting for the installation of the
32-bit Matlab 2009a to finish, I tried updating
our seisBLRMS.m code.
  
  1467   Fri Apr 10 01:24:08 2009 ranaUpdateComputersallegra update (sort of)I
tried to play an .avi file on allegra. In
a normal universe this would be easy, but
  
  1468   Fri Apr 10 03:10:08 2009 ranaSummaryLockingLaser PM to REFL-DC transfer functions at multiple CARM offsetsI hereby award the previous rainbow transfer
functions the plot innovation of the month
award for its use of optical frequency to
  
  1475   Sun Apr 12 19:27:20 2009 ranaUpdatePSLPMC LO Calibration[quote]
3.8Vpp is about 16dBm. 
The mixer for the PMC demodulator is level
  
ELOG V3.1.3-