  11236   Wed Apr 22 14:56:18 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signal[Koji, Manasa]

Since the bandwidth of the fiber
PD is ~ 1GHz, we could design the frequency
  
  11270   Mon May 4 10:21:09 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signalAttached is the schematic of the analog
DFD and the plot showing the zero-crossing
for a delay line length of 27cm. The bandwidth
 DFD.pngDFD_resp.png 
  11272   Mon May 4 12:42:34 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signalKoji suggested that I make a cosine fit
for the curve instead of a linear
fit.
 DFD_cosfit.png 
  11280   Mon May 11 13:21:25 2015 manasaUpdateCDSc1lsp and c1sup not runningI found the c1lsp and
c1sup models not running anymore on c1lsc
  
  11281   Mon May 11 13:26:02 2015 manasaUpdateIMCMC_F calibrationThe last MC_F calibration was done by Ayaka
: Elog
7823
  
  11282   Mon May 11 14:08:19 2015 manasaUpdateCDSc1lsp and c1sup removed?I just found out that c1lsp and c1sup models
no more exist on the FE status medm screens.
I am assuming some changes were done to the
  
  11283   Mon May 11 15:15:12 2015 manasaUpdateGeneralRan ASS for armsArm powers had drifted to ~ 0.5 in transmission.

X and Y arms were locked and ASS'd
to bring the arm transmission powers to
  
  11286   Tue May 12 12:04:41 2015 manasaUpdateGeneralSome maintenance* Relocked IMC. I guess
it was stuck somewhere in the autlocker loop.
I disabled autolocker and locked it manually.
  
  11300   Mon May 18 14:46:20 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signalMeasuring the voltage noise
and frequency response of the Analog Delay-line
Frequency Discriminator (DFD)
 DFDnoise.pngDFDnoise_AC.pngFreqResp.pngDFD.zip 
  11309   Tue May 19 11:50:52 2015 manasaUpdatePEMNo noticeable effect from M4.0 earthquakeThere was an earthquake: M4.0
- 40km SSW of South Dos Palos, California 

No noticeable effects on the IFO.
  
  9409   Tue Nov 19 11:56:10 2013 manasa, jenne, ericQUpdateLSCPRM- OSEM side ccd camera is in place

    

       
            
  
  9156   Tue Sep 24 20:43:45 2013 masayukiSummarySUSoptical levers centeringI centered optical levers of ITMX,BS,ETMY.
I also change the position of optical levers
of ITMX, ETMY, ITMY, BS on Friday night(9/21),
 Screenshot-Untitled_Window.pngScreenshot-Untitled_Window-1.png 
  9183   Tue Oct 1 17:14:53 2013 masayukiUpdateGreen LockingALS servo filters modified 
 [Manasa, Masayuki]
 OLTF.pdffilter_change.pdf 
  9197   Thu Oct 3 10:29:03 2013 masayukiUpdateGreen LockingNew ALS autolocker flowchart 
 [Manasa, Masayuki]
We made a new flowchart of ALS autolocker.
 flowchart.pdf 
  9321   Thu Oct 31 00:06:45 2013 masayukiUpdateComputer Scripts / Programscds fft,tf,offsetsI
wrote the scripts for cdsutils.
1.
  
  2718   Sun Mar 28 17:28:26 2010 matt, kiwamuUpdateGreen Lockingfrequency discriminator for green PLLLast Friday, Matt made a frequency discriminator
circuit on a bread board in order
 6x 
  11257   Sun Apr 26 20:10:10 2015 max isiHowToGeneralSummary pagesI have set up new summary pages for the
40m: http://www.ligo.caltech.edu/~misi/summary/
This website shows plots (time series,
  
  11279   Mon May 11 12:17:19 2015 max isiHowToGeneralSummary pagesI have created a wiki page with introductory
info about the summary page configuration:
https://wiki-40m.ligo.caltech.edu/Daily summary
  
  384   Mon Mar 17 18:30:48 2008 mevansConfigurationPEMAdaptive FilteringIt seems that adaptive filtering can achieve
results similar to those of the MISO FIR
Wiener (entry 369).  The adaptive code simulates
 mcacc_adaptive.png 
  394   Sat Mar 22 22:39:02 2008 mevansSummaryCDSDirect Form 2 filters are badHere I show a comparison between the filter
algorithm currently used in LIGO (Direct
Form II), and an alternative algorithm designed
 low-noise_filtering.pnglow-noise_zoom.pngFiltRT.zip 
  395   Sun Mar 23 00:43:08 2008 mevansHowToGeneralOnline Adaptive FilteringI wrote a short document about the OAF running
on the ASS.  Since there is no BURT setup,
I put a script in /cvs/cds/caltech/scripts
 OnlineAdaptiveFilter.pdf 
  2728   Mon Mar 29 15:19:33 2010 mevansUpdateGreen Lockingfrequency discriminator for green PLLThanks for the great entry! 
In order to make this work for higher
frequencies, I would add  Hartmut's suggestion
  
  4442   Fri Mar 25 01:27:29 2011 mevansFrogsGreen Lockingdigital frequency countingToday we tried the Schmitt trigger DFD,
and while it works it does not improve the
noise performance.  At least part of
  
  6314   Fri Feb 24 16:10:48 2012 mikeUpdateComputersPyNDS and a PlotPower Spectral Density plot using PyNDS,
comparing 5 fast data channels for ETMX.
**EDIT** Script here:
 PSD_Comparison.png 
  3060   Wed Jun 9 19:47:08 2010 nancyUpdatePEMlead balls on concrete


   
        
            
  
  3081   Wed Jun 16 18:12:16 2010 nancyConfigurationComputers40MARSi added my laptop's mac address to teh
martian at port 13 today.
 
  
  3101   Wed Jun 23 11:31:12 2010 nancyUpdateWIKI-40M UpdateWeekly UpdateThis week I attended a whole lot of orientations,
lectures, and meetings related to SURF. Done
with general and laser safety training.
  
  3143   Wed Jun 30 11:39:20 2010 nancyUpdateWIKI-40M UpdateWeekly UpdateWednesday Morning E-log :
 
Most of the time through this week,
  
  3168   Wed Jul 7 12:45:00 2010 nancyUpdate Weekly UpdateWednesday after the meeting - Started report,
learnt mode cleaner locking from Kiwamu and
Rana, saw how to move optics on the tables
  
  3174   Wed Jul 7 22:58:08 2010 nancyUpdateIOOMC alignment values.Nancy and Koji:
This is what I and Koji measured
after aligning the MC in the afternoon.
  
  3182   Thu Jul 8 19:43:16 2010 nancyUpdateIOOWFS calculationsThe WFS error signals were recorded in
the order 
WFS1_PIT
  
  3183   Thu Jul 8 20:32:22 2010 nancyUpdateIOOMC alignment values.I and Koji were trying to lock the mode
cleaner for measuring the  beam power at
MC2 end. That is when we obtained the trans
  
  3184   Thu Jul 8 21:44:43 2010 nancyUpdateIOOWFS calculations 
I just found the singular values
and the condition number of the 4*4 matrix
  
  3197   Mon Jul 12 15:49:56 2010 nancyUpdateSUSCharacterisation of the QPDI and koji setup the measurement of the
QPD response to the pitch and yaw displacements
of the beam spot.
 fullyaw.jpgyaw_linear.jpgfullpitch.jpgpitch_linear.jpg 
  3198   Mon Jul 12 17:05:30 2010 nancyUpdateSUSCharacterisation of the QPD

    
        
 plot.pngplot.png 
  3208   Tue Jul 13 17:36:42 2010 nancyUpdateIOOWavefront Sensing Matrix ControlFor yesterday - July 12th.
Yesterday, I tried understanding
the MEDM and the Dataviewer screens for the
  
  3218   Wed Jul 14 12:31:11 2010 nancyUpdateGeneralWeekly UpdateSummary of this week's work  


Wednesday
- Aligned the mode cleaner with Koji, and
then measured the beam characteristics at
  
  3236   Fri Jul 16 15:39:27 2010 nancyUpdateIOOWavefront Sensors- switched offI tuned the gain of WFS to 0 last night
at about 3am.
I turned it back on now.
  
  3253   Tue Jul 20 18:29:43 2010 nancyUpdateIOOQPD installed behind the MC2 
Yesterday I installed teh QPD on
the table behind MC2, and observed teh signal
  
  3352   Tue Aug 3 03:15:06 2010 nancyUpdateIOOMC back to locked modeI turned the WFS gain to 0.02 back, and
the MC is locked, the data for the seismic
motion might be meaningful nowforth.
  
  3357   Wed Aug 4 11:10:28 2010 nancyUpdateIOOMode Cleaner WFSYesterday, I started twiddling with the
Mode Cleaner at about 2 pm.
  
  3358   Wed Aug 4 12:49:42 2010 nancyUpdateIOOMode Cleaner WFS

    
        
 6x 
  3365   Thu Aug 5 01:29:39 2010 nancyUpdateIOOMode Cleaner WFS 
I calculated the MC1&3 Vs WFS1&2
Output Matrix today from the above measurements
  
  3366   Thu Aug 5 11:48:52 2010 nancyUpdateIOOMode Cleaner WFS

    
        
  
  3387   Mon Aug 9 13:32:02 2010 nancyUpdateIOOMode Cleaner ASC E-log entry for
Friday - will attach more plots to this entry
 6x 
  3389   Mon Aug 9 21:50:50 2010 nancyUpdateIOOMode Cleaner ASC


   
        
            
  
  3417   Thu Aug 12 23:49:04 2010 nancyUpdateEnvironmentLaser chiller temp raisedSince the laser is off, Jenne and I rasied
the chiller-chiller (small AC in the Control
Room) set point temperature to 
  
  3419   Fri Aug 13 09:41:00 2010 nancyOmnistructureComputersCharger for dell laptop I have taken the charger for the
dark gray dell laptop from its station, and
have labelled the information there too.
  
  3244   Mon Jul 19 14:14:03 2010 nancy, kojiUpdateIOOQPD Response Transfer FunctionFriday night myself and Koji measured the
Transfer function of the QPD circuit at MC2
side using a chopper . Following was our
  
  3245   Mon Jul 19 14:16:01 2010 nancy, kojiUpdateIOOQPD Response Transfer Function

    
        
 QPDTF2.png 