  11782   Wed Nov 18 17:09:22 2015 KojiSummaryPSLPMC Servo analysisSummary

The PMC servo was analysed. OLTF
was measured and modeled by ZPK (Attachment
 PMC_OLTF.pdfPMC_DSP.pdf 
  11793   Fri Nov 20 15:44:12 2015 KojiSummaryPSLAdded 17.5kHz LPF to the PMC servoAs a final tune of the PMC servo, I've
added 1nF cap at the error signal amplification
stage. The diagram has been updated and uploaded
 PMC_OLTF.pdfPMC_noise_comparison.pdf 
  11900   Wed Dec 23 15:43:02 2015 ranaSummaryPSLPMC FSS IMC RF summing boxThe EOM upstream of the PMC is used as
the phase corrector for the FSS/IMC servo.
It is also used to apply the 35.5 MHz PDH
 PMCFSSsummingBox.png 
  12169   Fri Jun 10 18:16:59 2016 varunUpdatePSLRealignment of pre mode cleanerThe mode cleaner was misaligned probably
due to the earthquake (the drop in the
MC transmitted value slightly after utc 7:38:52
 pmctrans_mcsum_signals.png 
  12170   Mon Jun 13 09:08:17 2016 SteveUpdatePSLPMC slow driftThe PMC transmission slow degration or
it's input beam is not stable.

 
 PMCslowDrift.png 
  12192   Thu Jun 16 18:08:57 2016 JohannesUpdatePSLBefore the AOM installationThere was only one razor blade beam dump
labeled for atmospheric use left, but that's
all we need. Steve is working on restocking.
 IMG_20160615_154556392e.jpg 
  12196   Fri Jun 17 22:36:11 2016 JohannesUpdatePSLAOM installationSubham and I have placed the AOM back into
the setup right in front of the PMC.

Steps undertaken:
 aom_new_mount.jpgaom_beam_split.jpgaom_dump_IR.jpg 
  12198   Mon Jun 20 08:26:56 2016 SteveUpdatePSLAOM picturesGood job Johannes and Subham.

 
 AOMinplace.jpginplaceAOM.jpgAOMin.png 
  12573   Wed Oct 19 18:32:25 2016 rana, yinziUpdatePSLRefCav thermal control: heater is deadWe wanted to re-activate the Heater for
the reference cavity today to use it as a
testbed for PID autotuning and the new heater
  
  12627   Fri Nov 18 17:52:42 2016 gautamUpdatePSLFSS Slow control -> Python, WFS re-engaged[yinzi, craig, gautam]

Yinzi had translated the Perl PID
script used to implement the discrete-time
  
  12628   Sun Nov 20 23:53:38 2016 awadeUpdatePSLFSS Slow control -> Python, WFS re-engagedI made a very slighly updated version of
Yinzi's script that pulls the channel
names and actuator hardstop limits from
  
  12792   Thu Feb 2 18:32:51 2017 ranaSummaryPSLPMC alignmentRe-aligned the beam going into the PMC
today around 5 PM. I noticed that its all
in pitch and since I moved both of the mirrors
  
  12911   Mon Mar 27 20:41:21 2017 rana, gautamUpdatePSLPMC DAQ assay for feed-forward integrationWe are thinking to use the PMC signals
to help us in figuring out the feedback /
feedforward stuff and making it better.
 TEK00000.PNG20170327_194931.jpg20170327_204554.jpg 
  12916   Wed Mar 29 11:41:19 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationThe C1IOO frontend machine that resides
in 1X1/1X2 has 2 ADCs, ADC0 and ADC1. The
latter has 28 out of 32 channels unused at
 C1ALS_PSLnamespace.pngPMCcheckout.pdfD980352-A-40m_151119.pdf 
  12918   Thu Mar 30 00:16:09 2017 gautamUpdatePSLPSL NPRO PZT calibrationAs part of the ongoing effort to try and
calibrate the PMC DAQ channels into physical
units, I tried to get a calibration for the
  
  12920   Thu Mar 30 18:11:01 2017 ranaUpdatePSLPMC DAQ assay for feed-forward integrationWhat you have drawn looks good to me: the
cut should be between TP3 and pin3 of the
AD620. This should maintain the DC coupled
  
  12925   Mon Apr 3 17:25:13 2017 gautamUpdatePSLPSL NPRO PZT calibrationSummary:

By sweeping the laser frequency
and looking at the PMC PDH error signal,
 PDHerr.pdfNPROcalib.pdf 
  12926   Mon Apr 3 23:07:09 2017 gautamUpdatePSLPMC DAQ assay for feed-forward integrationI made some changes to the DAQ path on
the PMC servo board, as per the plan posted
earlier in this thread. Summary of changes:
  
  12928   Tue Apr 4 17:27:58 2017 ranaUpdatePSLPSL NPRO PZT calibrationgood cal. I wonder if this data also gives
us a good measurement of the cavity pole
or if the photo-thermal self-locking effect
  
  12939   Tue Apr 11 00:38:37 2017 gautamUpdatePSLPMC demod moved off servo boardAs discussed at the Wednesday meeting last
week, I tried moving the demodulation of
the PMC error signal off the PMC servo board,
 PMC_Ctrl_spec.pdf 
  12940   Wed Apr 12 00:36:53 2017 gautamUpdatePSLPMC demod moved off servo boardHere is a more detailed comparison of the
spectra of the signals at the front panel
DAQ LEMO output, measured with the Agilent
 PMC_digitalSpec.pdfPMC_DAQ_spectra.pdf 
  12944   Tue Apr 18 01:01:03 2017 gautamUpdatePSLPMC OLTF measured, DAQ channels calibratedQuick entry, details to follow in the AM
tomorrow.


I calibrated the PMC DAQ
 PMCspectra_calibrated.pdfPMC_MEDMs.png 
  12945   Tue Apr 18 16:10:00 2017 gautamUpdatePSLPMC OLTF measured, DAQ channels calibratedHere are the details:


PMC OLTF:


the
procedure used was identical to what Koji
 PMC_OLTF_170418.pdf 
  12946   Tue Apr 18 23:37:15 2017 ranaUpdatePSLPMC OLTF measured, DAQ channels calibratedWhat's
the reasoning behind setting the the gain
  
  12947   Wed Apr 19 15:13:30 2017 gautamUpdatePSLPMC/MCL multicoherenceI used a one hour stretch of data from
last night to look at coherence between the
PMC control signal and MCL, to see if the
 PMC_MCL_multicoherence.pdf 
  13137   Mon Jul 24 12:00:21 2017 gautamUpdatePSLPSL NPRO mysteriously shut offSummary:

At around 10:30AM
 IMG_7454.JPG 
  13213   Wed Aug 16 14:57:01 2017 SteveUpdatePSLref Cavity heating blanket power supplyThe last entry I found relating to ref
cavity was
2011 Aug 19
 refCavPSheat.jpgrefCavTempSens.jpgrefTempSen_1X1.jpg 
  13223   Thu Aug 17 08:42:27 2017 SteveUpdatePSLPSL HEPAThe PSL HEPA was running noisy at 100V  
The bearing is wearing out. I turned it down
to 30V It is quiet there.
  
  13264   Mon Aug 28 23:22:56 2017 johannesUpdatePSLPSL table auxiliary NPROI moved the axuiliary NPRO to the PSL table
today and started setting up the optics.

The Faraday Isolator was showing
 aom_switching_zoomin.pngaom_switching_zoomout.pngaom_switching_mini_zoomin.pngaom_switching_mini_zoomout.png 
  13270   Tue Aug 29 20:04:09 2017 ranaUpdatePSLPSL table auxiliary NPROI don't understand why the 1st order
diffracted beam doesn't go to zero when
you shut off the drive. My guess is that
  
  13271   Tue Aug 29 21:36:59 2017 johannesUpdatePSLPSL table auxiliary NPRO


 isomet_mini_1st_zoomout.pngisomet_mini_0th_zoomout.png 
  13278   Thu Aug 31 00:19:35 2017 rana[^r]UpdatePSLIMC/FSS FAST gainnominal changed from 22 to 23 dB to minimize
PC drive RMS

  
  13298   Tue Sep 5 23:13:44 2017 johannesUpdatePSLPSL table auxiliary NPROI used Gautam's mode measurement of
the auxiliary NPRO (w=127.3um,
z=82mm) for the spacing of the optics
 PSL_IR.pdfpsl_aux_laser.pdf 
  13301   Thu Sep 7 23:09:00 2017 johannesUpdatePSLPSL table auxiliary NPROI brought the DEI Pulser
unit and a suitable Pockels cell
over from Bridge today (I also found an identical
 3200-1113_200_switching_PD10A_zoomin.png3200-1113_200_switching_PD10A_zoomout.png 
  13306   Mon Sep 11 12:40:32 2017 johannesUpdatePSLPSL table auxiliary NPROI changed the PSL table auxiliary laser
setup to the 200 MHz AOM and put the light
back in the fiber. Coupling efficiency is
 psl_aux_laser2.svg.pngPSL_IR2.png 
  13457   Wed Nov 29 15:33:16 2017 ranaUpdatePSLPMC lockingPMC wasn't locking. Had to power down
c1psl. Did burt restore. Still not great.

I think many of the readbacks on
  
  13488   Mon Dec 18 20:37:18 2017 gautamUpdatePSLPMC MEDM cleanupThere are fewer lies on this screen now.
For reference, the details of the electronics
modifications made are in this
 PMC_revamped.png 
  13532   Thu Jan 11 14:47:11 2018 SteveUpdatePSLshelf work for tomorrowI have just received the scheduling of
the PSL self work for tomorrow. Gautam and
I agreed that if it is needed I will shut
  
  13538   Fri Jan 12 10:26:24 2018 SteveUpdatePSL PSL shelf work scheduleMeasurements for good fit were made. The
new shelf will be installed on next Tuesday
at 2pm
  
  13549   Tue Jan 16 11:05:51 2018 gautamUpdatePSL PSL shelf - AOM power connection interruptedWhile moving the RefCav to facilitate the
PSL shelf install, I
bumped the power cable to the AOM driver.
  
  13550   Tue Jan 16 16:18:47 2018 SteveUpdatePSLnew PSL shelf in place[ Johannes, Rana, Mark and Steve ]

On the second trial the shelf was
installed. Plastic cover removed. South end
 DSC00020.JPG 
  13551   Tue Jan 16 21:46:02 2018 gautamUpdatePSL PSL shelf - AOM power connection interruptedJohannes informed me that he touched up
the PMC REFL camera alignment. I am holding
off on re-soldering the AOM driver power
  
  13714   Wed Mar 28 17:28:58 2018 SteveUpdatePSLnoise eater on or offTill RIN measurement noise eater is off
on 2W laser. The inno 1W  has no noise
eater.
 inno2W.pnginno1W.png 
  13743   Mon Apr 9 23:49:50 2018 ranaUpdatePSLPSL chansI think we can scrap the 126MOPA channels
since they're associated with the Lightwave
NPRO and MOPA. We should add the channels
  
  13818   Sat May 5 20:30:21 2018 KojiUpdatePSLModulation depth measurement for the 3IFO aLIGO EOM and aftermathCaution:
Because of this work and my negligence, the
RF output of the main Marconi for the IFO
  
  13819   Sat May 5 22:32:07 2018 KojiUpdatePSLModulation depth measurement for the 3IFO aLIGO EOM The 3IFO EOM was formerly tuned as the
H2 EOM, so the resonant frequencies are different
from the nominal aLIGO ones.
  
  13842   Tue May 15 10:42:14 2018 KojiUpdatePSLModulation depth measurement for the 3IFO aLIGO EOM and aftermathThe marconi RF output was turned on and
thus the RF generator condition was restored
to the nominal state on Friday 11th.
  
  13900   Thu May 31 02:04:55 2018 johannesUpdatePSLAUX laser state of mindThe AUX laser is down to 5.4 mW output
power 
 IMG_20180530_220058190.jpg 
  13911   Sun Jun 3 22:48:59 2018 johannesUpdatePSLaux laser replacementI brought the NPRO from the Crackle experiment
over to the 40m Lab and set it up on the
PSL table to replace the slowly dying AUX
  
  13912   Mon Jun 4 02:52:52 2018 johannesUpdatePSLaux laser replacement> While the laser output is going strong,
the controller displays a power output of
only 10 mW, which makes me think that the
  
ELOG V3.1.3-