40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 274 of 344  Not logged in ELOG logo
    Reply  Tue Feb 3 16:43:48 2015, manasa, Update, General, RF amplifier for ALS 
I pulled out the RF amplifier box from the IOO rack again and added the new RF amplifiers for FOL. 

I replaced one of the decoupling capacitors of the ALS beat note RF amplifier ; the poloproylene capacitor with a
ceramic capacitor (0.1uF) .
    Reply  Wed Feb 4 21:05:24 2015, manasa, Update, General, RF amplifier for ALS RFampBox.png
The components of the RF amplifier box are in place. The RF amplifier box has been mounted on the IOO rack and the front panel connections have
been labeled. Attached is the photo of how things look in the inside for future reference.

Sometime in the next few days the box will be pulled out to replace the panel mount SMA barrels in the front with insulated ones.
    Reply  Wed Feb 4 21:09:43 2015, manasa, Update, General, X endtable work scheduled tomorrow 
The X end fiber setup will be put together tomorrow morning.
Let me know if there are any concerns.




    Reply  Thu Feb 5 15:21:25 2015, manasa, Update, General, X endtable work  
[EricG, Manasa]

We were at the X end today trying to couple AUX X light into the fiber. 

The proposed plan still did not give a good beampath. The last steering mirror before the fiber coupler was sticking out of the table enclosure.
Entry  Fri Feb 6 18:06:18 2015, manasa, Update, General, Fiber Optic module for FOL FOLfiberModule.png
I pulled out the Fiber Optic Module for FOL from the rack inside the PSL table enclosure and modified it. The beat PDs were moved into the box to
avoid breaking the fiber pigtail input to the PD.

The box has 3 input FC/APC connectors (PSL and AUX lasers) and 2 output FC/APC connectors (10% of the beatnote for the AUX
    Reply  Tue Feb 10 13:48:58 2015, manasa, Update, LSC, Probable cause for headaches last night 
I found the PSL enclosure open (about
a feet wide) on the north side this morning. I am assuming that whoever did the X beatnote
alignment last night forgot to close the door to the enclosure before locking attempts 
    Reply  Tue Feb 10 16:01:21 2015, manasa, Update, General, AUX X fiber coupled 72% AUXxTelescope.png
Plan C finally worked. We have 1.454mW of AUX X light at the PSL table (2mW
incident on the fiber coupler). 
Entry  Wed Feb 11 18:44:53 2015, manasa, Update, General, Optical fiber module 
I have moved the optical fiber module for FOL to the PSL table. It is setup on the optical table right now for testing.

Once tests are done, the box will move to the rack inside the PSL enclosure. 

While doing any beat note alignment, please
    Reply  Thu Feb 12 12:16:04 2015, manasa, Update, General, Fiber shielding 
[Steve, Manasa]

The fibers around the PSL table were shielded to avoid any tampering.
Entry  Thu Feb 12 12:23:21 2015, manasa, Update, General, Waking up the PDFR measurement system 
[EricG, Manasa]

We woke up the PDFR measurement setup that has been sleeping since summer. We ran a check for the laser module and the multiplexer module. We tried setting things up for measuring frequency response of AS55.
Entry  Wed Feb 25 11:01:05 2015, manasa, Update, Computer Scripts / Programs, New screen for FOL PID loop 
Created a new medm screen C1ALS_FOL_PID.adl for FOL PID loop
control in /medm/als/master/

This is not currently linked to
Entry  Thu Feb 26 10:56:34 2015, manasa, Update, General, Running cables 
[Steve, Manasa]

We ran power cables and sma cables for the FOL fiber module from the PSL table to the IOO rack.
    Reply  Thu Feb 26 16:37:21 2015, manasa, Frogs, LSC, RIP illegal power supply 
No more illegal power supply at the LSC rack 

The amplifiers are now being powered by the rack power supply through fuse blocks.
    Reply  Thu Feb 26 16:46:37 2015, manasa, Update, General, IOO rack power supply 
I shutdown the +/-15V and the +/-24V sorensons on the IOO rack to connect the FOL RF PDs to the rack power supply.

They were turned back ON after the work. PMC and MC were relocked.




    Reply  Thu Mar 5 11:18:28 2015, manasa, Update, General, RF amplifier box 
I pulled out the RF amplifier box from the IOO rack and swapped the amplifiers for FOL beat frequency amplification. The earlier gain of 62dB (ZFL500LN
+ ZFL500LN) was reduced to 40dB gain (ZFL500LN+ZFL2AD).

I also swapped one of the broken sma cables that was connecting the two amplifiers with a good one. Front ports of the module were
Entry  Thu Mar 5 12:27:27 2015, manasa, Update, General, FOL fiber box on the PSL table 
Working around the PSL table

I have put the FOL fiber box on the PSL table. The fibers carrying AUX and PSL light are
connected and the RFPDs have been powered up. I can see the beat frequency on the frequency counters; but for some reason Domenica (that brings the
    Reply  Fri Mar 6 14:29:59 2015, manasa, Update, General, FOL troubleshooting 
[EricQ, Manasa]

Domenica:
Since Domenica was not picking up an IP address and hence not responding to pings or ssh even after power
    Reply  Mon Mar 9 14:43:31 2015, manasa, Update, General, FOL troubleshooting FOL_trouble.pdfIMAG0341.jpgIMAG0342.jpg
Figuring out the problem with frequency counter readouts:





RF
amplifier box:
Entry  Tue Mar 10 14:47:05 2015, manasa, Update, PSL, PMC relocked 
PMC was locked in a bad state. FSS slow actuator adjust was at ~ -0.7 and PZT voltage at ~45.

So I set these right by moving the appropriate sliders and relocked it. FSS slow actuator adjust brought back to zero and PZT voltage ~115. PMC
trans after relock is 0.789.
    Reply  Tue Mar 10 17:48:07 2015, manasa, Update, General, FOL troubleshooting 
[Koji, Manasa]

This problem was solved by changing the Frequency Counter range settings.

Frequency counter automatic range setting has been modified and now the range can be manually set depending on the input frequency.
    Reply  Wed Mar 11 15:35:38 2015, manasa, Update, General, Waking up the PDFR measurement system 
I was around the 1Y1 rack today. Trials were done to get the PDFR of AS55.




Quote:



[EricG, Manasa]
    Reply  Thu Mar 19 14:37:17 2015, manasa, Configuration, IOO, IMC relocked 
The autolocker was struggling to lock the IMC. I disabled the autolocker and locked the IMC manually. It seems happy right now. 

With PMC trans at 0.717 counts, the IMC trans sum is ~15230.




Entry  Tue Mar 24 10:53:30 2015, manasa, Update, General, Scripts updated to the svn 
I found that the scripts in FOL and PDFR directories were not in the svn. These were added to the svn.
Entry  Tue Mar 24 15:22:12 2015, manasa, Update, Computer Scripts / Programs, New slow channels for FOL 
[Koji, Manasa]

I have created new slow channels for FOL. To do so, I have edited the fcreadout.db file in Domenica and the C0EDCU.ini file
Entry  Wed Apr 1 11:42:30 2015, manasa, Update, Computer Scripts / Programs, PID script in python 
Since none of us here are experts in pearl, I have put together a python script for a simple PID controller. This can be imported into
any main scripts that will run the actual PID loop. The script, PID.py,
exists in /scripts/general/
    Reply  Fri Apr 3 14:57:38 2015, manasa, Update, SUS, BS oplev BS_oplev_Apr3.png
The BS oplev has been misbehaving and kicking the optic from time to time since noon. The kicks are not strong enough to trip the watchdogs (current
watchdog max counts for the sensors is 135).

I took a look at the spectrum of the BS oplev error in pit and yaw with both loops enabled while the optic was stable. There is nothing alarmingly
    Reply  Wed Apr 8 21:10:55 2015, manasa, Update, General, Waking up the PDFR measurement system 
I was poking around with the PDFR hardware today.

I moved the Agilent which had its screen projected on the monitor. I have put it back...but please verify the settings before using it for tonight.
Entry  Wed Apr 22 11:48:30 2015, manasa, Summary, General, Delay line frequency discriminator for FOL error signal 
Since the Frequency counters have not been a reliable error signal for FOL PID loop, we will put together an analog delay line frequency dicriminator
as an alternative method to obtain the beat frequency.

The configuration will be similar to what was done in elog 4254 in the first
    Reply  Wed Apr 22 14:56:18 2015, manasa, Summary, General, Delay line frequency discriminator for FOL error signal 
[Koji, Manasa]

Since the bandwidth of the fiber PD is ~ 1GHz, we could design the frequency discriminator to have a wider bandwidth (~ 500MHz). The output from
the frequency discriminator could then be used to define the range setting of the frequency counter for readout or may be even error signal to
    Reply  Mon May 4 10:21:09 2015, manasa, Summary, General, Delay line frequency discriminator for FOL error signal DFD.pngDFD_resp.png
Attached is the schematic of the analog DFD and the plot showing the zero-crossing for a delay line length of 27cm. The bandwidth for the linear output
signal obtained roughly matches what is expected from the length difference (370MHz) .

We could use a smaller cable to further increase our bandwidth. I propose we use this analog DFD to determine the range at which the frequency
    Reply  Mon May 4 12:42:34 2015, manasa, Summary, General, Delay line frequency discriminator for FOL error signal DFD_cosfit.png
Koji suggested that I make a cosine fit for the curve instead of a linear fit.

I fit the data to  
Entry  Mon May 11 13:21:25 2015, manasa, Update, CDS, c1lsp and c1sup not running 
I found the c1lsp and c1sup models not running anymore on c1lsc (white blocks for status lights on medm).

To fix this, I ssh'd into c1lsc. c1lsc status did not show c1lsp and c1sup models running on it.
    Reply  Mon May 11 13:26:02 2015, manasa, Update, IMC, MC_F calibration 
The last MC_F calibration was done by Ayaka : Elog 7823




Quote:



And does anyone know
    Reply  Mon May 11 14:08:19 2015, manasa, Update, CDS, c1lsp and c1sup removed? 
I just found out that c1lsp and c1sup models no more exist on the FE status medm screens. I am assuming some changes were done to the models as well.

Earlier today, I was looking at some of the old medm screens running on Donatella that did not reflect this modification. 

Did I miss any elogs about this or was this change not elogged??
Entry  Mon May 11 15:15:12 2015, manasa, Update, General, Ran ASS for arms 
Arm powers had drifted to ~ 0.5 in transmission.

X and Y arms were locked and ASS'd to bring the arm transmission powers to ~1.
Entry  Tue May 12 12:04:41 2015, manasa, Update, General, Some maintenance 
* Relocked IMC. I guess it was stuck somewhere in the autlocker loop. I disabled autolocker and locked it manually. Autolocker has been
reenabled and seems to be running just fine.

* The X arm has been having trouble staying locked. There seemed to be some amount of gain peaking. I reduced
    Reply  Mon May 18 14:46:20 2015, manasa, Summary, General, Delay line frequency discriminator for FOL error signal DFDnoise.pngDFDnoise_AC.pngFreqResp.pngDFD.zip
Measuring the voltage noise and frequency response of the Analog Delay-line Frequency Discriminator (DFD)

The schematic and an actual photo of the setup is shown below. The setup was checked to be physically sturdy with no loose connections or moving
parts.
Entry  Tue May 19 11:50:52 2015, manasa, Update, PEM, No noticeable effect from M4.0 earthquake 
There was an earthquake: M4.0 - 40km SSW of South Dos Palos,
California 

No noticeable effects on the IFO. MC did not lose lock; however the arms did unlock.
    Reply  Tue Nov 19 11:56:10 2013, manasa, jenne, ericQ, Update, LSC, PRM- OSEM side ccd camera is in place 


    
        
            Quote:
        
        
            

           
            
                
           
Entry  Tue Sep 24 20:43:45 2013, masayuki, Summary, SUS, optical levers centering Screenshot-Untitled_Window.pngScreenshot-Untitled_Window-1.png
I centered optical levers of ITMX,BS,ETMY. I also change the position of optical levers of ITMX, ETMY, ITMY, BS on Friday night(9/21), of ITMX, ETMY,
BS on Monday night. Both are around 6:00 ~ 7:00.But centering on Monday was totally wrong, because I centered with not good IFO alignment.
The attachment is the 5 days trend of the opt lev of ITMX. First gap is alignment on Friday and Second gap is the alignment on Monday. Now I centered
    Reply  Tue Oct 1 17:14:53 2013, masayuki, Update, Green Locking, ALS servo filters modified OLTF.pdffilter_change.pdf
 
 [Manasa, Masayuki]
[revised at 10/1 pm 5:00]
    Reply  Thu Oct 3 10:29:03 2013, masayuki, Update, Green Locking, New ALS autolocker flowchart flowchart.pdf
 
 [Manasa, Masayuki]
We made a new flowchart of ALS autolocker. We added the additional step to find the beat note frequency. We have to find a way to read the PSL
Entry  Thu Oct 31 00:06:45 2013, masayuki, Update, Computer Scripts / Programs, cds fft,tf,offsets 
I wrote the scripts for cdsutils.
1. fft
usage: fft.py [-h] [-c N_CYCL] [-a N_AVG] freq channel [channel ...]
Entry  Sun Mar 28 17:28:26 2010, matt, kiwamu, Update, Green Locking, frequency discriminator for green PLL 6x
Last Friday, Matt made a frequency discriminator circuit on a bread board in order to test the idea
and study the noise level. I think it will work for phase lock acquisition of Green locking.
As a result a response of 100kHz/V and a noise level of 2uV/rtHz @ 10Hz are yielded. This corresponds to 0.2Hz/rtHz @ 10Hz.
Entry  Sun Apr 26 20:10:10 2015, max isi, HowTo, General, Summary pages 
I have set up new summary pages for the 40m: http://www.ligo.caltech.edu/~misi/summary/
This website shows plots (time series, spectra, spectrograms, Rayleigh statistics) of relevant channels and is updated with new data every 30 min.

The content and structure of the pages is determined by configuration files stored in nodus:/users/public_html/gwsumm-ini/ . The code looks at
    Reply  Mon May 11 12:17:19 2015, max isi, HowTo, General, Summary pages 
I have created a wiki page with introductory info about the summary page configuration: https://wiki-40m.ligo.caltech.edu/Daily summary help

We can also use that to collect tips for editing the configuration files, etc.




    Reply  Mon Mar 17 18:30:48 2008, mevans, Configuration, PEM, Adaptive Filtering mcacc_adaptive.png
It seems that adaptive filtering can achieve results similar to those of the MISO FIR Wiener (entry 369).  The adaptive code simulates real-time operation,
but uses the same data used by Rana for the Wiener filter.  I ran the adaptive filter over the data 100 times to ensure that it was well trained... maybe
too well.
Entry  Sat Mar 22 22:39:02 2008, mevans, Summary, CDS, Direct Form 2 filters are bad low-noise_filtering.pnglow-noise_zoom.pngFiltRT.zip
Here I show a comparison between the filter algorithm currently used in LIGO (Direct Form II), and an alternative algorithm designed to reduce numerical
noise.  The input signal is 
Entry  Sun Mar 23 00:43:08 2008, mevans, HowTo, General, Online Adaptive Filtering OnlineAdaptiveFilter.pdf
I wrote a short document about the OAF running on the ASS.  Since there is no BURT setup, I put a script in /cvs/cds/caltech/scripts to help with setting
initial parameters: upass.
    Reply  Mon Mar 29 15:19:33 2010, mevans, Update, Green Locking, frequency discriminator for green PLL 
Thanks for the great entry! 
In order to make this work for higher frequencies, I would add  Hartmut's suggestion of a frequency dividing input stage.  If we divide  the
input down by 100, the overall range will be about 200MHz, and the  noise will be about 20Hz/rtHz.  That might be good enough... but we can  hope
ELOG V3.1.3-