40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 273 of 341  Not logged in ELOG logo
Entry  Thu Feb 23 15:48:43 2017, johannes, Update, Computers, c1psl un-bootable scope_PDA520_ITM_aligned_ETM_misaligned.pngscope_PDA520_ITM_slightly_misaligned.pngpmc_trans_last10days.png
    Reply  Thu Feb 23 18:52:53 2017, rana, Update, Computers, c1psl un-bootable 
    Reply  Thu Feb 23 19:44:48 2017, johannes, Update, Computers, c1psl un-bootable slow_startup_logs.tar.gz
    Reply  Fri Feb 24 20:38:01 2017, johannes, Update, Computers, c1psl boot-stall culprit identified 
    Reply  Mon Feb 27 15:33:10 2017, Steve, Update, VAC, RGA scan at day 130 rgascan@130d.png
    Reply  Tue Feb 28 01:28:52 2017, johannes, Update, Computers, c1psl un-bootable 
    Reply  Tue Feb 28 08:04:48 2017, steve, Update, PEM, ETMX damping recovered ETMX.png
    Reply  Tue Feb 28 18:25:22 2017, rana, Update, PEM, ETMX damping recovered 
    Reply  Wed Mar 1 08:28:04 2017, Steve, Update, Optical Levers, oplev laser RIN RIN_1103P.pngRIN_HeNe.png
Entry  Wed Mar 1 16:00:41 2017, gautam, Update, Computer Scripts / Programs, Matlab R2016b installed 
    Reply  Wed Mar 1 17:25:28 2017, Steve, Update, LSC, MCREFL condition pictures IMG_3646.JPGmcRefl_1.jpgmcRefl_3.jpgmcRefl_5.jpg
    Reply  Wed Mar 1 21:15:40 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box RF_amp_(1).pdf
    Reply  Wed Mar 1 23:56:09 2017, gautam, Update, IMC, Front panel for 29.5 MHz amplifier box 
    Reply  Thu Mar 2 13:59:04 2017, Steve, Update, Optical Levers, oplev laser RIN 1103P@2d.png
    Reply  Thu Mar 2 17:58:45 2017, rana, Update, Optical Levers, oplev laser RIN 
    Reply  Thu Mar 2 20:32:18 2017, Lydia, Update, IMC, Front panel for 29.5 MHz amplifier box 
    Reply  Fri Mar 3 17:24:21 2017, Steve, Update, Optical Levers, oplev laser RIN 3march17.pdf
    Reply  Sun Mar 5 12:41:23 2017, gautam, Update, IMC, WFS servo-steppin WFS_stepping.pngWFS_comparisons.pdfWFSdigitalAA.pdf
    Reply  Mon Mar 6 09:12:59 2017, Steve, Update, safety, crane inspection 2017 inspection_2017.jpg
Entry  Mon Mar 6 14:47:49 2017, gautam, Update, Summary Pages, Code status check script modified 
Entry  Mon Mar 6 16:32:36 2017, Steve, Update, General, old NPRO  
    Reply  Wed Mar 8 15:28:37 2017, Steve, Update, Optical Levers, oplev laser RIN RIN.jpgRIN_1103P_rotated.pdf
    Reply  Wed Mar 8 18:18:51 2017, johannes, Update, Computer Scripts / Programs, loss script 
Entry  Thu Mar 9 15:25:12 2017, Koji, Update, General, IMC/XYarms aligned/locked 
    Reply  Thu Mar 9 17:26:43 2017, Steve, Update, General, attempted ETMY picture taking 
    Reply  Thu Mar 9 20:11:04 2017, Koji, Update, General, attempted ETMY picture taking P3090032.JPG
    Reply  Thu Mar 9 22:28:11 2017, johannes, Update, Computer Scripts / Programs, loss script 
    Reply  Fri Mar 10 11:37:25 2017, gautam, Update, Computer Scripts / Programs, loss script 
    Reply  Fri Mar 10 18:00:22 2017, Steve, Update, General, attempted ETMY picture taking P3100044.JPGP3090024.JPG
    Reply  Fri Mar 10 19:48:56 2017, johannes, Update, Computer Scripts / Programs, loss script 
    Reply  Sat Mar 11 20:11:58 2017, johannes, Update, Computer Scripts / Programs, loss script 
    Reply  Mon Mar 13 16:47:41 2017, Steve, Update, PEM, Y-arm air conditon belts replaced 
    Reply  Tue Mar 14 09:08:11 2017, Steve, Update, Optical Levers, ETMX HeNe is dead this_morning.png
Entry  Tue Mar 14 10:40:30 2017, Steve, Update, SUS, OSEM filters are in filters.jpg
    Reply  Tue Mar 14 10:56:33 2017, gautam, Update, COC, RC folding mirrors - coating optimization PR3_R_170313_1701.pdfPR3AR_123_Layers_170313_1701.pdfPR3AR_R_170313_1752.pdfPR3AR_123_Layers_170313_1752.pdf
    Reply  Tue Mar 14 15:05:18 2017, Steve, Update, Optical Levers, history of ETMX oplev laser ETMX_1103P_3y.png
    Reply  Thu Mar 16 08:22:16 2017, Steve, Update, SUS, ETMX damping  laser_power_glitch.png
    Reply  Fri Mar 17 10:47:16 2017, Steve, Update, Optical Levers, ETMX oplev laser replaced 
    Reply  Fri Mar 17 14:49:09 2017, gautam, Update, LSC, MCREFL condition pictures IMG_7219.JPGMCREFL_X.pdfMCREFL_Y.pdf
Entry  Mon Mar 20 11:18:58 2017, gautam, Update, CDS, No internet connectivity on control room machines 
    Reply  Mon Mar 20 14:39:44 2017, gautam, Update, CDS, No internet connectivity on control room machines 
    Reply  Mon Mar 20 17:12:08 2017, steve, Update, PEM, particle counter inside of PSL enclousure enclousure_partical_count.png
Entry  Tue Mar 21 15:13:44 2017, gautam, Update, IMC, IMC input beam mode matching IMG_7220.JPGIMC_ModeMatch.pdfsingleLensSensitivity.pdfsensitivity.pdfIMCmodeMatch.m
Entry  Tue Mar 21 21:21:58 2017, gautam, Update, IOO, WFS filter banks updated MCWFS_screen.png
    Reply  Tue Mar 21 21:59:48 2017, gautam, Update, IMC, IMC input beam mode matching IMG_3654.JPGIMG_3655.JPG
    Reply  Wed Mar 22 00:33:00 2017, gautam, Update, IMC, IMC length offset nulling offsetInvestigation.pdfoffset_summing_amp.pdf
    Reply  Wed Mar 22 16:58:25 2017, gautam, Update, IMC, WFS sensing matrix measurements 
    Reply  Thu Mar 23 01:44:53 2017, gautam, Update, IMC, WFS sensing matrix measurements IMC_WFS_segment_TF.pdfIMC_WFS_channels_TF.pdfTFsummary.pdfIMC_WFS_170322.xlsx.zip
    Reply  Thu Mar 23 08:43:11 2017, rana, Update, IMC, WFS sensing matrix measurements 
    Reply  Thu Mar 23 23:38:58 2017, gautam, Update, IMC, MC SUS damping gains stepped down 
ELOG V3.1.3-