40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 271 of 344  Not logged in ELOG logo
   +  Reply  Wed Nov 30 14:54:01 2016, Johannes, Update, CDS, Slow machine replacement 
   +  Reply  Wed Nov 30 17:08:56 2016, gautam, Update, LSC, Binary output breakout box removed 
   +  Reply  Thu Dec 1 02:19:13 2016, gautam, Update, LSC, Binary output breakout box restored MC1_glitch_fast.pngITMY_testerGlitch.pngITMYsatbox.pngULcomparison.pdf
   +  Reply  Thu Dec 1 08:02:57 2016, Steve, Update, LSC, glitching ITMY_UL_LL ITMY_UL_LL.png
Entry  Thu Dec 1 20:20:15 2016, gautam, Update, IMC, IMC loss measurement plan IMG_3471.JPG
   +  Reply  Fri Dec 2 10:57:08 2016, steve, Update, PEM, door seal replaced 1_year_PEM.png
   +  Reply  Fri Dec 2 11:56:42 2016, gautam, Update, LSC, MC1 LEMO jiggled IMG_3474.JPGMC1_LR_dead.png
   +  Reply  Fri Dec 2 16:21:12 2016, gautam, Update, General, repaired projector, new mixer arrived and installed 
   +  Reply  Fri Dec 2 16:40:29 2016, gautam, Update, IMC, 24V fuse pulled out 
   +  Reply  Fri Dec 2 18:02:37 2016, Koji, Update, IOO, IMC WFS Demod board measurement & analysis WFS_demod_noise_orig.pdfWFS_demod_noise_mod.pdf
   +  Reply  Sat Dec 3 13:27:35 2016, Koji, Update, IOO, IMC WFS Demod board measurement & analysis WFS_demod_noise.pdfdemod.pdf
   +  Reply  Mon Dec 5 01:58:16 2016, gautam, Update, IMC, IMC ringdowns IMCringdown.pdfIMCringdown_2.pdf
   +  Reply  Mon Dec 5 15:05:37 2016, gautam, Update, LSC, MC1 glitches are back Mc1glitches.png
   +  Reply  Mon Dec 5 15:55:25 2016, gautam, Update, IMC, IMC ringdowns 7x
   +  Reply  Mon Dec 5 19:29:52 2016, gautam, Update, IMC, IMC ringdowns REFLanomaly.pdf
   +  Reply  Tue Dec 6 00:43:41 2016, gautam, Update, IMC, more IMC ringdowns 
   +  Reply  Tue Dec 6 13:37:02 2016, Koji, Update, IOO, IMC WFS Demod board measurement & analysis demod.pdfWFS_error_noise.pdf
   +  Reply  Tue Dec 6 16:47:40 2016, Koji, Update, IOO, IMC WFS whitening filter investigation D990196-C.pdf
   +  Reply  Tue Dec 6 17:54:08 2016, Koji, Update, IOO, IMC WFS whitening filter investigation 34.png
   +  Reply  Tue Dec 6 22:41:49 2016, Koji, Update, IOO, IMC WFS whitening filter investigation 
   +  Reply  Wed Dec 7 11:52:48 2016, ericq, Update, IMC, Partial IMC ringdowns IMCpartial.pngIMCpartial.zip
   +  Reply  Thu Dec 8 07:56:05 2016, Steve, Update, PEM, EQ6.5m Northen CA eq6.5FerndaleCA.png16d_glitching-_trend.pngEQ6.5_&4.7mFerndaleCa.png
   +  Reply  Thu Dec 8 10:13:43 2016, Steve, Update, LSC, glitching ITMY_UL has a history glitching__ITMY-UL_2007.png
   +  Reply  Thu Dec 8 19:01:21 2016, rana, Update, IMC, Partial IMC ringdowns 
   +  Reply  Tue Dec 13 17:26:42 2016, Koji, Update, IOO, IMC WFS whitening filter investigation 
   +  Reply  Wed Dec 14 19:16:57 2016, Lydia, Update, CDS, Acromag Binary I/O testing 
   +  Reply  Thu Dec 15 03:46:19 2016, rana, Update, IOO, IMC WFS whitening filter investigation 
   +  Reply  Thu Dec 22 09:37:20 2016, Steve, Update, VAC, RGA scan at day 63 pd80-d63.pngpd80-580Hz-d63.png
   +  Reply  Thu Dec 29 10:24:56 2016, Steve, Update, PEM, EQ5.7mHawthorn NV eq5.7HawthorneNV.png
Entry  Thu Dec 29 21:48:32 2016, rana, Update, IOO, MC AutoLocker hung because c1iool0 asleep again 
   +  Reply  Fri Dec 30 10:27:46 2016, rana, Update, DetChar, summary pages dead again 
   +  Reply  Thu Jan 5 21:43:16 2017, rana, Update, DetChar, summary pages dead again 
Entry  Sun Jan 8 12:47:06 2017, rana, Update, General, Optical Layout in DCC 
   +  Reply  Mon Jan 9 09:18:47 2017, Steve, Update, PEM, power glitch MondayMorning.png
   +  Reply  Mon Jan 9 16:12:30 2017, Steve, Update, General, Optical Layout in DCC drawings_on_paper.jpg
   +  Reply  Tue Jan 10 14:24:09 2017, Steve, Update, VAC, RGA scan at day 82 pd80VNd82.png
   +  Reply  Tue Jan 10 16:20:11 2017, Steve, Update, CDS, power glitch......Raid is rebuilding rebuilding_in_progress.png
   +  Reply  Tue Jan 10 21:47:00 2017, rana, Update, CDS, power glitch 
   +  Reply  Tue Jan 10 22:55:43 2017, gautam, Update, CDS, power glitch - recovery steps 
   +  Reply  Wed Jan 11 16:35:03 2017, gautam, Update, CDS, power glitch - recovery progress powerGlitchRecoveryJan2017.png
Entry  Wed Jan 11 19:20:23 2017, Max Isi, Update, Summary Pages, December outage 
   +  Reply  Thu Jan 12 02:45:53 2017, Johannes, Update, General, Next armloss steps ass_illustration.pdf
   +  Reply  Thu Jan 12 17:31:51 2017, gautam, Update, CDS, DC errors DCerror.png
   +  Reply  Thu Jan 12 23:22:34 2017, rana, Update, Summary Pages, December outage 
   +  Reply  Fri Jan 13 08:54:32 2017, Johannes, Update, General, DC PD installed ASDCPD_up.jpgASDCPD_down.jpgscrambled_osci.jpg
   +  Reply  Fri Jan 13 10:53:03 2017, Steve, Update, PEM, doors are fixed 
   +  Reply  Fri Jan 13 14:18:28 2017, Steve, Update, PEM, air condition fixed PEM_120d.png
   +  Reply  Fri Jan 13 14:33:00 2017, MAX (not Rana), Update, Summary Pages, December outage 
   +  Reply  Fri Jan 13 21:41:23 2017, Koji, Update, CDS, DC errors 
Entry  Fri Jan 13 23:39:46 2017, gautam, Update, General, ETMX suspension electronics problems? 
ELOG V3.1.3-