  6311   Fri Feb 24 04:12:44 2012 kiwamuUpdateSUSfreeswing testThe following optics were kicked:
MC1
MC2 MC3 ETMX ETMY ITMX ITMY PRM SRM BS
Fri
Feb 24 04:11:15 PST 2012
1014120690
 
  
  6313   Fri Feb 24 15:01:31 2012 kiwamuUpdateLSCY arm + PRMI part IIThe figure below shows the time series
of the Y arm + PRMI trail.
 time_series.png 
  6317   Fri Feb 24 19:18:28 2012 kiwamuUpdateLSCY arm + PRMI : how they should look likeI
calculated how the DC signals should look
like in the Y arm PRMI configuration.
 expected_time_series.png 
  6319   Fri Feb 24 23:14:09 2012 kiwamuUpdateCDStdsavg went crazyI found that the LSCoffset script didn't
work today. The script is supposed to null
the electrical offsets in all the LSC channels.
  
  6320   Sat Feb 25 00:37:42 2012 kiwamuUpdateSUSoplev spectra during PRMI lockSomehow
the angular stability of the central part
have not been so great.
 oplev_PRMI.pdf 
  6321   Sat Feb 25 14:27:26 2012 kiwamuUpdateLSCglitches in the RFPD outputsLast
night I took a closer look at the LSC analog
signals to find which components are making
  
  6330   Tue Feb 28 12:00:54 2012 kiwamuUpdateLSCinstalled anti-whitening filtersI
found that none of the filter banks in the
LSC input signals have the precise anti-whitening
  
  6331   Tue Feb 28 15:48:32 2012 kiwamuUpdateLSCinstalled anti-whitening filtersI installed the rest of the precise
anti-whitening filters. Now all of the LSC
sensors have the right filters.
  
  6334   Tue Feb 28 16:39:25 2012 kiwamuUpdateLSCMICH and PRCL signals in a simulationI briefly ran a Optickle code to see
how the PRC macroscopic length screws up
the sensing matrix in the PRMI configuration.
 REFL11_PRMI.pngREFL55_PRMI.png 
  6336   Tue Feb 28 20:49:33 2012 kiwamuUpdateLSCinsalling OSAI am installing an OSA on the AP table
and it's ongoing.
I am leaving some stuff scattered
  
  6340   Wed Feb 29 04:23:14 2012 kiwamuUpdateLSCREFL OSA installedI
placed the OSA (Optical Spectrum Analyzer)
on the AP table and this OSA will monitor
  
  6350   Mon Mar 5 03:22:54 2012 kiwamuUpdatePSLPMC realignedI realigned the steering mirrors for the
PMC. The trans value went up from 0.79 to
0.83.
  
  6351   Mon Mar 5 03:50:49 2012 kiwamuUpdateIOOPZT1 PITCH railingPZT1
started railing in the pitch direction and
because of this TRY doesn't go more than
  
  6352   Mon Mar 5 05:39:36 2012 kiwamuUpdateLSCREFL OSA installedThe
OSA for the REFL beam is now fully functional.
 APtable.png 
  6353   Mon Mar 5 06:11:08 2012 kiwamuSummaryLSCplansPlans:

     DRMI (PRMI) + one arm
  
  6354   Mon Mar 5 13:11:06 2012 kiwamuUpdateLSCinstalled a long BNC cable for REFL OSAA
long BNC cable was installed and now the
REFL OSA signal is happily shown on an oscilloscope
  
  6355   Mon Mar 5 14:10:35 2012 kiwamuUpdateLSCpower budget on the AP tableI
checked the laser powers on the AP table
and confirmed that their powers are low enough
 power_budget.png 
  6357   Mon Mar 5 17:07:58 2012 kiwamuUpdateIOOrealigned MCI
have slightly shifted the MC beam pointing
to relax the PZT1 PITCH. As a result the
  
  6362   Tue Mar 6 01:35:03 2012 kiwamuUpdateLSCMICH characterization[Keiko / Kiwamu]
 Update on the MICH characterization:

    The OSAs weren't so great
  
  6369   Wed Mar 7 04:08:48 2012 kiwamuUpdateSUSBS SIDE gain was too lowThe
BS SIDE damping gain seemed too low. The
gain had been 5 while the rest of the suspensions
  
  6378   Wed Mar 7 19:10:06 2012 kiwamuUpdateLSCREFL OSA : how the signal look likeJust a quick report on the REFL OSA.

The attached plot below shows the
 OSArefl.png 
  6382   Wed Mar 7 22:04:05 2012 kiwamuUpdateLSCREFL OSA : how the signal look likeI was also wondering about the same thing,
comparing with what Mirko obtained before
with the same OSA ( 
  
  6386   Thu Mar 8 04:13:12 2012 kiwamuUpdateLSCupdate on the locking activity[Keiko / Kiwamu]
 Some updates on the locking
activity:
  
  6388   Thu Mar 8 23:37:03 2012 kiwamuUpdateIOOdither Y arm dither scriptI
disabled the feedback to the PZT1 PITCH in
the Y arm dithering scripts so that it won't
  
  6403   Tue Mar 13 07:04:55 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of timeThe
punch line is -- the sensing matrix still
looks strange in the PRMI configuration.
 PRCL.pngMICH.png 
  6405   Tue Mar 13 16:40:06 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of time: detailsHere
I describe the measurement of the sensing
matrix.
 lockins_MICH.png 
  6406   Tue Mar 13 16:56:19 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of timeNext steps:

    Compare the obtained sensing
matrix with an Optickle model. Particularly
  
  6407   Tue Mar 13 19:14:40 2012 kiwamuUpdateLSCNoise estimatino in the REFL33Q as a MICH sensor
A feasibility study of the REFL33Q as a MICH
sensor was coarsely performed from the point
 NB_REFL33.png 
  6409   Wed Mar 14 03:34:44 2012 kiwamuUpdateSUSAdjustment of BS suspension output matrix : coupling from SIDE to POS[Rana / Kiwamu]
 We put some elements in the
 Untitled.png 
  6410   Wed Mar 14 04:03:37 2012 kiwamuUpdateIOOPZT1 and associate extra worksAs the PZT1 has not been functional, I
have been aligning the Y arm to the input
beam instead of aligning the beam to the
  
  6411   Wed Mar 14 04:19:51 2012 kiwamuUpdateLSCREFL33Q for MICH control : not good I tried the REFL33Q for controlling
MICH in the PRMI configuration (#6407)
 Untitled.png 
  6414   Wed Mar 14 13:16:50 2012 kiwamuUpdateLSCA correction on Noise estimatino in the REFL33QA
correction on the previous elog about the
REFL33Q noise:
  
  6426   Fri Mar 16 16:03:03 2012 kiwamuUpdateIOOMC alignment servo : put some offsets in the TRANS QPD signalThe
MC alignment servo wasn't great in the last
1 hour or so as it kept disturbing the MC
  
  6436   Thu Mar 22 16:45:06 2012 kiwamuUpdateCDSc1scx and c1scy not properly runningIt
seems that neither c1scx nor c1scy is working
properly as their ADC counts are showing
  
  6437   Thu Mar 22 17:35:59 2012 kiwamuUpdateLockingmode profiles of the POP and POX beams : not bright enoughI tried to measure the beam profiles at
the POP and POX ports as Koji mentioned in
his entry (#6421).
  
  6440   Fri Mar 23 01:59:59 2012 kiwamuUpdateIOOREFL beam currently unavilable[Suresh / Kiwamu]
Currently
the REFL beam is bypassed by additional mirrors
  
  6444   Mon Mar 26 15:15:16 2012 kiwamuUpdateIOOexpected beam profile of PRM reflectionI have estimated how the mode profile
of the PRM reflection should be, as shown
in the plot blow.
 expected_edit.png 
  6445   Mon Mar 26 16:25:44 2012 kiwamuUpdateIOOexpected v.s. measured beam profile of PRM reflection[Suresh / Kiwamu]
 We did the 2nd round of
the PRM reflection mode scan on Friday.
 PRMreflection.pngDSC_4001_small.jpg 
  6446   Mon Mar 26 18:04:43 2012 kiwamuUpdateIOOmode scan at the REFL portFor those who are interested in the
actual data, I attache the actual data in
zip file together with a python plot code.
 mode_profile.pngREFLmodescan.zip 
  6450   Tue Mar 27 02:46:28 2012 kiwamuUpdateIOOREFL beam availableThe dump and some temporary mirrors
were removed and now the REFL beam is available
again.
  
  6471   Fri Mar 30 10:20:51 2012 kiwamuUpdateLSClocking last nightI was trying to make the DRMI lock more
robust.
Increasing the gains of the oplev
  
  6474   Sat Mar 31 08:01:07 2012 kiwamuUpdateLSCDRMI measurementI have measured the sensing matrix of the
DRMI although the lock still doesn't stay
for a long time.
  
  6488   Thu Apr 5 06:27:51 2012 kiwamuUpdateLSCAS110 sideband monitor installed[Jenne / Kiwamu]

 We
  
  6489   Thu Apr 5 07:19:16 2012 kiwamuUpdateLSCDRMI locking I
tried locking the DRMI to the signal-extraction
condition with the new trigger by AS110.
 DRMI_2012Apr4_edit.png 
  6506   Sat Apr 7 01:56:05 2012 kiwamuUpdateLSCOSA signal in DRMI conditionIt wasn't a dream or illusion -- I was
locking the DRMI to the right condition last
Wednesday (#6489).
 OSA.png 
  6508   Sat Apr 7 06:58:34 2012 kiwamuUpdateLSCDRMI lock : lost good alignmentSomehow I lost the good alignment, where
the lock can be frequently acquired and hence
I didn't go further ahead.
  
  6512   Mon Apr 9 18:18:14 2012 kiwamuUpdateLSCDRMI time seriesHere is a time series when the DRMI is
being locked.
You can see that the AS110 goes up
 time_series1.png 
  7534   Fri Oct 12 01:56:26 2012 kiwamuUpdateGeneralAlignment situation of interferometer [Koji / Kiwamu]
 We have realigned the interferometer
except the incident beam.
  
  8866   Thu Jul 18 01:10:00 2013 kiwamuUpdateGreen LockingALS Y performance with the new whitening filter 
  
  9051   Thu Aug 22 10:20:32 2013 kiwamuUpdateLSCDRMI Locked for 1+ minute!!!!!!Wonderful
! I like the video -- the spatial
  
ELOG V3.1.3-