10642
|
Mon Oct 27 22:19:17 2014 |
Jenne | Update | CDS | c1iscex restarted |
I'm not sure why, but c1iscex did not want to do an mxstream restart. It would complain at me that "* ERROR: mx_stream is already stopping. "
Koji suggested that I reboot the machine, so I did. I turned off the ETMX watchdog, and then did a remote reboot. Everything came back nicely, and the mx_stream process seems to be running. |
4020
|
Tue Dec 7 16:09:53 2010 |
josephb | Update | CDS | c1iscex status |
I swapped out the IO chassis which could only handle 3 PCIe cards with the another chassis which has space for 17, but which previously had timing issues. A new cable going between the timing slave and the rear board seems to have fixed the timing issues.
I'm hoping to get a replacement PCI extension board which can handle more than 3 cards this week from Rolf and then eventually put it in the Y-end rack. I'm also still waiting for a repaired Host interface board to come in for that as well.
At this point, RFM is working to c1iscex, but I'm still debugging the binary outputs to the analog filters. As of this time they are not working properly (turning the digital filters on and off seems to have no effect on the transfer function measured from an excitation in SUSPOS, all the way around to IN1 of the sensor inputs (but before measuring the digital fitlers). Ideally I should see a difference when I switch the digital filters on and off (since the analog ones should also switch on and off), but I do not. |
7963
|
Wed Jan 30 13:50:27 2013 |
Jenne | Update | Computers | c1iscex still down |
[Koji, Jenne]
We noticed that the iscex computer is still down, but the IOP is (was) running. When we sat down to look at it, c1x01 was 'breathing', had a non-zero CPU_METER time, and the error was 0x4000, which I've never seen before. The fb connection was still red though. Also, it is claiming that its sync source is 1pps, not TDS like it usually is.
Since things were different, Koji restarted the 2 other models running on iscex, with no resulting change. We then did a 'rtcds restart all', and the IOP is no longer breathing, and the error message has changed to 0xbad. The sync source is still 1pps.
Moral of the story: c1iscex is still down, but temporarily showed signs of life that we wanted to record. |
7970
|
Thu Jan 31 10:23:39 2013 |
Jamie | Update | Computers | c1iscex still down |
Quote: |
[Koji, Jenne]
We noticed that the iscex computer is still down, but the IOP is (was) running. When we sat down to look at it, c1x01 was 'breathing', had a non-zero CPU_METER time, and the error was 0x4000, which I've never seen before. The fb connection was still red though. Also, it is claiming that its sync source is 1pps, not TDS like it usually is.
Since things were different, Koji restarted the 2 other models running on iscex, with no resulting change. We then did a 'rtcds restart all', and the IOP is no longer breathing, and the error message has changed to 0xbad. The sync source is still 1pps.
Moral of the story: c1iscex is still down, but temporarily showed signs of life that we wanted to record.
|
There's definitely a timing issue with this machine. I looked at it a bit yesterday. I'll try to get to it by the end of the week. |
9433
|
Mon Dec 2 16:04:47 2013 |
Jamie | Update | CDS | c1iscex timing problem mysteriously disappears??? (thanksgiving miracle???) |
Quote: |
There is definitely a timing distribution malfunction at the c1iscex IO chassis. There is no timing link between the "Master Timer Sequencer D050239" at the 1X6 and the c1iscex IO chassis. Link lights at both ends are dead. No timing, no running models.
It does not appear to be a problem with the Master Timer Sequencer. I moved the c1iscey link to the J15 port on the sequencer and it worked fine. This means its either a problem with the fiber or the timing card in the IO chassis. The IO timing card is powered and does have what appear to be normal status lights on (except for the fiber link lights). It's getting what I think is the nominal 4V power. The connection to the IO chassis backplane board look ok. So maybe it's just a dead fiber issue?
I do not know what could have been the problem with c1auxex, or if it's related to the fast timing issue.
|
I just got over here from Downs, where I managed to convince Todd to let me borrow one of their three remaining timing slave boards for c1iscex. I walked down to the X end to replace the board only to discover that the link light on the existing timing board was back! c1iscex was not responding, so I hard rebooted the machine, and everything came up rosy (all green!):

To repeat, I DID NOTHING. The thing was working when I got here. I have no idea when it came back, or how, but it's at least working for the moment. I re-enabled the watchdog for ETMX SUS and it's now damped normally.
I'm going to hold on to the timing card for a couple of days, in case the failure comes back, but we'll need to return it to Downs soon, and probably think about getting some spare backups from Columbia. |
9434
|
Mon Dec 2 17:05:13 2013 |
Jenne | Update | CDS | c1iscex timing problem mysteriously disappears??? (thanksgiving miracle???) |
Steve was trying to do something to it this morning, but I'm not exactly clear on what it was. Maybe that helped? Steve, can you tell us what you were trying to do this morning? |
9435
|
Tue Dec 3 07:42:23 2013 |
Steve | Update | CDS | c1iscex timing problem mysteriously disappears??? (thanksgiving miracle???) |
Quote: |
Steve was trying to do something to it this morning, but I'm not exactly clear on what it was. Maybe that helped? Steve, can you tell us what you were trying to do this morning?
|
I was trying to repeat elog 9007 I did only get to line 2 of the Solution by Koji when Ottavia shut down, where I was working. This was all what I did. |
13079
|
Sun Jun 25 22:30:57 2017 |
gautam | Update | General | c1iscex timing troubles |
I saw that the CDS overview screen indicated problems with c1iscex (also ETMX was erratic). I took a closer look and thought it might be a timing issue - a walk to the X-end confirmed this, the 1pps status light on the timing slave card was no longer blinking.
I tried all versions of power cycling and debugging this problem known to me, including those suggested in this thread and from a more recent time. I am leaving things as it for the night, will look into this more tomorrow. I've also shutdown the ETMX watchdog for the time being. Looks like this has been down since 24Jun 8am UTC. |
Attachment 1: c1iscex_status.png
|
|
13081
|
Mon Jun 26 22:01:08 2017 |
Koji | Update | General | c1iscex timing troubles |
I tried a couple of things, but no fundamental improvement of the missing LED light on the timing board.
- The power supply cable to the timing board at c1iscex indicated +12.3V
- I swapped the timing fiber to the new one (orange) in the digital cabinet. It didn't help.
- I swapped the opto-electronic I/F for the timing fiber with the Y-end one. The X-end one worked at Y-end, and Y-end one didn't work at X-end.
- I suspected the timing board itself -> I brought a "spare" timing board from the digital cabinet and tried to swap the board. This didn't help.
Some ideas:
- Bring the X-end fiber to C1SUS or C1IOO to see if the fiber is OK or not.
- We checked the opto-electronic I/F is OK
- Try to swap the IO chassis with the Y-end one.
- If this helps, swap the timing board only to see this is the problem or not. |
13085
|
Wed Jun 28 20:15:46 2017 |
gautam | Update | General | c1iscex timing troubles |
[Koji, gautam]
Here is a summary of what we did today to fix the timing issue on c1iscex. The power supply to the timing card in the X end expansion chassis was to blame.
- We prepared the Y-end expansion chassis for transport to the X end. To do so, we disconnected the following from the expansion chassis
- Cables going to the ADC/DAC adaptor boards
- Dolphin connector
- BIO connector
- RFM fiber
- Timing fiber
- We then carried the expansion chassis to the X end electronics rack. There we repeated the above steps for the X-end expansion chassis
- We swapped the X and Y end expansion chassis in the X end electronics rack. Powering the unit, we immediately saw the green lights on the front of the timing card turn on, suggesting that the Y-end expansion chassis works fine at the X end as well (as it should). To further confirm that all was well, we were able to successfully start all the RT models on c1iscex without running into any timing issues.
- Next, we decided to verify if the spare timing card is functional. So we swapped out the timing card in the expansion chassis brought over to the X end from the Y end with the spare. In this test too, all worked as expected. So at this stage, we concluded that
- There was nothing wrong with the fiber bringing the timing signal to the X end
- The Y-end expansion chassis works fine
- The spare timing card works fine.
- Then we decided to try the original X-end expansion chassis timing card in the Y-end expansion chassis. This test too was successful - so there was nothing wrong with any of the timing card!
- Next, we decided to power the X-end timing chassis with its original timing card, which was just verified to work fine. Surprisingly, the indicator lights on the timing card did not turn on.
- The timing card has 3 external connections
- A 40 pin IDE connector
- Power
- Fiber carrying the timing signal
- We went back to the Y-end expansion chassis, and checked that the indicator lights on the timing card turned on even when the 40 pin IDE connector was left unconnected (so the timing card just gets power and the timing signal).
- We concluded that the power supply in the X end expansion chassis was to blame. Indeed, when Koji jiggled the connector around a little, the indicator lights came on!
- The connection was diagnosed to be somewhat flaky - it employs the screw-in variety of terminal blocks, and one of the connections was quite loose - Koji was able to pull the cable out of the slot applying a little pressure.
- I replaced the cabling (swapped the wires for thicker gauge, more flexible variety), and re-tightened the terminal block screws. The connection was reasonably secure even when I applied some force. A quick test verified that the timing card was functional when the unit was powered.
- We then replaced the X and Y-end expansion chassis (complete with their original timing cards, so the spare is back in the CDS cabinet), in the racks. The models started up again without complaint, and the CDS overview screen is now in a good state [Attachment #1]. The arms are locked and aligned for maximum transmission now.
- There was some additional difficulty in getting the 40-pin IDE connector in on the Y-end expansion chassis. Looked like we had bent some of the pins on the timing board while pulling this cable out. But Koji was able to fix this with a screw driver. Care should be taken when disconnecting this cable in the future!
There were a few more flaky things in the Expansion chassis - the IDE connectors don't have "keys" that fix the orientation they should go in, and the whole timing card assembly is kind of difficult and not exactly secure. But for now, things are back to normal it seems.
Wouldn't it be nice if this fix also eliminates the mystery ETMX glitching problem? After all, seems like this flaky power supply has been a problem for a number of years. Let's keep an eye out. |
Attachment 1: CDS_status_28Jun2017.png
|
|
11778
|
Wed Nov 18 10:10:53 2015 |
ericq | Update | CDS | c1iscey IO chassis missing brackets |
Steve and I inadvertently discovered that the c1iscey IO chassis doesn't have brackets to secure the cards where the ADC/DAC cables are connected, making them very easy to knock loose. All other IO chassis have these brackets. Pictures of c1iscey and c1lsc IO chassis to compare:
 
|
11789
|
Thu Nov 19 15:16:24 2015 |
ericq | Update | CDS | c1iscey IO chassis now has brackets |
[Steve, ericq]
Brackets for the c1iscey IO chassis cards have been installed. Now, I can't unseat the cards by wiggling the ADC or DAC cable.  |
4773
|
Tue May 31 15:45:37 2011 |
Jamie | Update | CDS | c1iscey IOchassis powered off for some reason. repowered. |
We found that both of the c1iscey models (c1x05 and c1scy) were unresponsive, and weren't coming back up even after reboot. We then found that the c1iscey IOchassis was actually powered off. Steve's accepts some sort of responsibility, since he was monkeying around down there for some reason. After powerup and reboot, everything is running again. |
5791
|
Wed Nov 2 21:49:59 2011 |
Katrin | Update | CDS | c1iscey computer died again |
while I was not doing anything on the machine. |
6002
|
Thu Nov 24 15:27:15 2011 |
kiwamu | Update | CDS | c1iscey hardware rebooted |
The c1iscey machine crashed around 1:00 AM last night and I did a hard-ware reboot by pressing a button on the front panel of the machine.
After the reboot its been running okay so far.
The crash happened after I pressed the "Diag Reset" button on the CDS status screen. |
2551
|
Thu Jan 28 09:14:51 2010 |
Alberto | Configuration | Computers | c1iscey, c1iscex, c1lsc, c1asc rebooted |
This morning the LSC scripts wheren't running properly. I had to reboot c1iscey, c1iscex, c1lsc, c1asc .
I burtrestored to Monday January 25 at 12:00. |
7550
|
Mon Oct 15 20:45:58 2012 |
jamie | Update | IOO | c1lsc DAC0 now connected to tip-tilt SOS DW boards |
The tip-tile SOS dewhite/AI boards are now connected to the digital system.

I put together a chassis for one of our space DAC -> IDC interface boards (maybe our last?). A new SCSI cable now runs from DAC0 in the c1lsc IO chassis in 1Y3, to the DAC interface chassis in 1Y2.
Two homemade ribbon cables go directly from the IDC outputs of the interface chassis to the 66 pin connectors on the backplane of the Eurocrate. They do not go through the cross-connects, cause cross-connects are stupid. They go to directly to the lower connectors for slots 1 and 3, which are the slots for the SOS DW/AI boards. I had to custom make these cables, or course, and it was only slightly tricky to get the correct pins to line up. I should probably document the cable pin outs.
- cable 0: IDC0 on interface chassis (DAC channels 0-7) ---> Eurocrate slot 0 (TT1/TT2)
- cable 1: IDC1 on interface chassis (DAC channels 8-15)---> Eurocrate slot 2 (TT3/TT4)
As reported in a previous log in this thread, I added control logic to the c1ass front-end model for the tip-tilts. I extended it to include TT_CONTROL (model part) for TT3 and TT4 as well, so we're now using all channels of DAC0 in c1lsc for TT control.
I tested all channels by stepping through values in EPICS and reading the monitor and SMA outputs of the DW/AI boards. The channels all line up correctly. A full 32k count output of a DAC channel results in 10V output of the DW/AI boards. All channels checked out, with a full +-10V swing on their output with a full +-32k count swing of the DAC outputs.
We're using SN 1 and 2 of the SOS DW/AI boards (seriously!)
The output channels look ok, and not too noisy.
Tomorrow I'll get new SMA cables to connect the DW/AI outputs to the coil driver boards, and I'll start testing the coil driver outputs.
As a reminder: https://wiki-40m.ligo.caltech.edu/Suspensions/Tip_Tilts_IO
|
7553
|
Tue Oct 16 00:08:26 2012 |
Den | Update | IOO | c1lsc DAC0 now connected to tip-tilt SOS DW boards |
Quote: |
Tomorrow I'll get new SMA cables to connect the DW/AI outputs to the coil driver boards, and I'll start testing the coil driver outputs.
|
I've found a nice 16 twisted pair cable ~25m long and decided to use it as a port from 1Y3 to clean room cable instead of buying a new long one. I've added a break out board to the coil driver end to monitor outputs.

|
7561
|
Tue Oct 16 20:40:06 2012 |
Den | Update | IOO | c1lsc DAC0 now connected to tip-tilt SOS DW boards |
Full cable path from coil driver to osem input is now ready. I've tested Ch1-4 of the left AI and left coil driver. 15 pin outputs and monitors show voltage that we expect. I've checked voltage on the other side of the cable in the clean room, it is correct. We are ready to test the coils. We need to bake osem cables asap. Hopefully, Bob will start this job tomorrow.

|
12309
|
Mon Jul 18 18:44:52 2016 |
varun | Update | CDS | c1lsc FE recovered |
c1lsc FE is up and running.
Details:
2) The machine was manually rebooted.
3) c1daf was recompiled and installed, with the problematic piece of code removed.
4) NTP timing was adjusted.
5) Frame Builder was restarted.
6) All models on c1lsc machine were restarted.
Attachment 1 shows the CDS status after the recovery. I wont be trying to run frequency warping immediately, I will first finish implementing the other harmless modules first. |
Attachment 1: CDS_status160718.png
|
|
12303
|
Thu Jul 14 23:38:59 2016 |
varun | Update | CDS | c1lsc FE unresponsive |
Today, at around 10:30, c1lsc machine froze and stopped responding to ping and ssh after I compiled and restarted c1daf. I think it is due to a large array in one of my codes. The daqd.log file shows the following:
..................................................................
CA.Client.Exception...............................................
Warning: "Virtual circuit unresponsive"
Context: "c1lsc.martian.113.168.192.in-addr.arpa:5064"
Source File: ../tcpiiu.cpp line 945
Current Time: Thu Jul 14 2016 22:27:42.102649102
..................................................................
I think the c1lsc FE may need a hard reboot. |
12304
|
Fri Jul 15 12:21:28 2016 |
varun | Update | CDS | c1lsc FE unresponsive |
c1lsc is up and running, Eric did a manual reboot today.
Quote: |
Today, at around 10:30, c1lsc machine froze and stopped responding to ping and ssh after I compiled and restarted c1daf. I think it is due to a large array in one of my codes. The daqd.log file shows the following:
..................................................................
CA.Client.Exception...............................................
Warning: "Virtual circuit unresponsive"
Context: "c1lsc.martian.113.168.192.in-addr.arpa:5064"
Source File: ../tcpiiu.cpp line 945
Current Time: Thu Jul 14 2016 22:27:42.102649102
..................................................................
I think the c1lsc FE may need a hard reboot.
|
|
5610
|
Tue Oct 4 07:51:36 2011 |
steve | Update | CDS | c1lsc and c1sus are still down |
c1lsc and c1sus are still down. Only ETMX and ETMY are damped |
5607
|
Mon Oct 3 20:47:51 2011 |
kiwamu | Update | CDS | c1lsc and c1sus didn't run |
[Mirko / Jenne / Kiwamu]
Just a quick update. All the realtime processes on the c1lsc and c1sus machine didn't run at all.
Somehow the c1xxxfe.ko kernel module, where xxx is x04, x02, lsc, ass, sus, mcs, pem and rfm failed to be insmod.
The timing indicators on the c1lsc and c1sus machine are saying NO SYNC.
- According to log files (target/c1lsc/logs/log.txt)
insmod: error inserting '/opt/rtcds/caltech/c1/target/c1lsc/bin/c1lscfe.ko': -1 Unknown symbol in module
- dmesg on c1lsc (c1sus also dumps the same error message):
[ 45.831507] DXH Adapter 0 : sci_map_segment - Failed to map segment - error=0x40000d01
[ 45.833006] c1x04: DIS segment mapping status 1073745153
DXH dapter is a part of the Dolphine connections.
When a realtime codes is waking up, the code checks the Dolphin connections.
The checking procedure is defined by dolphin.c (/src/fe/doplhin.c).
According to a printk sentence in dolphin.c the second error message listed above will return status "0" if everything is fine.
The first error above is an error vector from a special dolphin's function called sci_map_segment, which is called in dolphin.c.
So something failed in this sci_map_segment function and is preventing the realtime code from waking up.
Note that sci_map_segment is defined in genif.h and genif.c which reside in /opt/srcdis/src/IRM_DSX/drv/src. |
5608
|
Mon Oct 3 21:20:30 2011 |
Jenne | Update | CDS | c1lsc and c1sus didn't run |
[Jenne, Mirko, Kiwamu, Koji, and Jamie by phone]
We just got off the phone with Jamie. In addition to all the stuff that Kiwamu mentioned, Mirko reverted the c1oaf model and C-code to stuff that was working successfully on Friday (using "svn export, rev # 1134) since that's what we were working on when all hell broke loose.
We did a few rounds of "sudo shutdown -h now" on c1lsc and c1sus machines, and pulled the power cords out.
We also switched the c1ioo and c1lsc 1PPS fibers in the fanout chassis, to see if that would fix the problem. Nope. c1ioo is still fine, and c1lsc is still not fine.
Still getting "No Sync".
We're going to call in Alex in the morning, if we can't figure it out soon. |
5611
|
Tue Oct 4 10:35:08 2011 |
Mirko | Update | CDS | c1lsc and c1sus running again |
[Alex, Mirko]
Alex fixed the computers this morning. It was in fact a dolphin problem:
Hi Jenne, figured it out. Even though dxadmin said the Dolphin net was fine, it wasn't. Something happeneed to DIS networkmanager and I had to restart it. It is running on fb:
controls@fb ~ $ ps -e | grep dis 12280 ? 00:00:00 dis_networkmgr
controls@fb ~ $ sudo /etc/init.d/dis_networkmgr restart
Once the restart was done both c1lsc and c1sus nodes were configured correctly, they printed the usual "node 12 is OK" "node 8 is OK" messages into the dmesg and was able to run /etc/start_fes.sh on lsc and sus to load all the FEs. Alex
Some lights on c1lsc were still red: C1:DAQ-FBO_C1SYS_SYS and the smaller red light left of it. Restarted the fb. Didn't help. Restarted c1lsc, all green now.
Restored autoburt from Oct 3. 19:07 on c1lsc and c1sus.
|
4706
|
Thu May 12 23:12:40 2011 |
kiwamu | Update | CDS | c1lsc crashed |
This is my third time to crash a real-time machine. This time I crashed c1lsc.
I physically rebooted c1lsc machine by pushing the power button and it came back and now running fine.
(what I did)
The story is almost the same as the last two times (1st time, 2nd time).
I edited c1lsc.ini file using daqconfig and then shutdown daqd running fb.
Some indicators for c1lsc on the C1_FE_STATUS screen became red. So I hit the 'DAQ reload' button on the C1LSC_GDS_TP screen.
Then c1lsc died and didn't respond to ping. |
13942
|
Mon Jun 11 18:49:06 2018 |
gautam | Update | CDS | c1lsc dead again |
Why is this happening so frequently now? Last few lines of error log:
[ 575.099793] c1oaf: DAQ EPICS: Int = 199 Flt = 706 Filters = 9878 Total = 10783 Fast = 113
[ 575.099793] c1oaf: DAQ EPICS: Number of Filter Module Xfers = 11 last = 98
[ 575.099793] c1oaf: crc length epics = 43132
[ 575.099793] c1oaf: xfer sizes = 128 788 100988 100988
[240629.686307] c1daf: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1cal: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1ass: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1oaf: ADC TIMEOUT 0 43039 31 43103
[240629.686307] c1lsc: ADC TIMEOUT 0 43039 31 43103
[240630.684493] c1x04: timeout 0 1000000
[240631.684938] c1x04: timeout 1 1000000
[240631.684938] c1x04: exiting from fe_code()
I fixed it by running the reboot script. |
Attachment 1: 36.png
|
|
1348
|
Tue Mar 3 10:39:07 2009 |
Alberto | Update | LSC | c1lsc discontinued functioning |
The c1lsc has been unstable since last night. Its status on the DAQ screen was oscillating from green to red every minute.
Yesterday, I power recycled it. That brought it back but the MC got unclocked and the autolocker could not get engaged. I think it's because the power recycling also turned c1iscaux2 off which occupies the same rack crate.
Killing the autolocker on op340 e restarting didn't work. So I rebooted also c1dcuepis and burt-restored almost all snapshot files. To do that, as usual, I had to edit the snapshot files of c1dcuepics to move the quotes from the last line.
After that I restarted the autolocker that time it worked.
This morning c1lsc was again in the same unstable status as yesterday. This time I just reset it (no power recycling) and then I restarted it. It worked and now everything seems to be fine. |
8366
|
Thu Mar 28 10:44:30 2013 |
Manasa | Update | Computers | c1lsc down |
c1lsc was down this morning.
I restarted fb and c1lsc based on elog
Everything but c1oaf came back. I tried to restart c1oaf individually; but it didn't work.
Before:

After:

|
14133
|
Sun Aug 5 13:28:43 2018 |
gautam | Update | CDS | c1lsc flaky |
Since the lab-wide computer shutdown last Wednesday, all the realtime models running on c1lsc have been flaky. The error is always the same:
[58477.149254] c1cal: ADC TIMEOUT 0 10963 19 11027
[58477.149254] c1daf: ADC TIMEOUT 0 10963 19 11027
[58477.149254] c1ass: ADC TIMEOUT 0 10963 19 11027
[58477.149254] c1oaf: ADC TIMEOUT 0 10963 19 11027
[58477.149254] c1lsc: ADC TIMEOUT 0 10963 19 11027
[58478.148001] c1x04: timeout 0 1000000
[58479.148017] c1x04: timeout 1 1000000
[58479.148017] c1x04: exiting from fe_code()
This has happened at least 4 times since Wednesday. The reboot script makes recovery easier, but doing it once in 2 days is getting annoying, especially since we are running many things (e.g. ASS) in custom configurations which have to be reloaded each time. I wonder why the problem persists even though I've power-cycled the expansion chassis? I want to try and do some IFO characterization today so I'm going to run the reboot script again but I'll get in touch with J Hanks to see if he has any insight (I don't think there are any logfiles on the FEs anyways that I'll wipe out by doing a reboot). I wonder if this problem is connected to DuoTone? But if so, why is c1lsc the only FE with this problem? c1sus also does not have the DuoTone system set up correctly...
The last time this happened, the problem apparently fixed itself so I still don't have any insight as to what is causing the problem in the first place . Maybe I'll try disabling c1oaf since that's the configuration we've been running in for a few weeks. |
4015
|
Mon Dec 6 16:49:43 2010 |
josephb | Update | CDS | c1lsc halfway to working |
C1LSC Status:
The c1lsc computer is running Gentoo off of the fb server. It has been connected to the DAQ network and is handling mx_streams properly (so we're not flooding the network error messages like we used to with c1iscex). It is using the old c1lsc ip address (192.168.113.62). It can ssh'd into.
However, it is not talking properly to the IO chassis. The IO chassis turns on when the computer turns on, but the host interface board in the IO chassis only has 2 red lights on (as opposed to many green lights on the host interface boards in the c1sus, c1ioo, and c1iscex IO chassis). The c1lsc IO processor (called c1x04) doesn't see any ADCs, DACs, or Binary cards. The timing slave is receiving 1PPS and is locked to it, but because the chassis isn't communicating, c1x04 is running off the computer's internal clock, causing it to be several seconds off.
Need to investigate why the computer and chassis are not talking to each other.
General Status:
The c1sus and c1ioo computers are not talking properly to the frame builder. A reboot of c1iscex fixed the same problem earlier, however, as Kiwamu and Suresh are working in the vacuum, I'm leaving those computers alone for the moment, but a reboot and burt restore probably should be done later today for c1sus and c1ioo
Current CDS status:
MC damp |
dataviewer |
diaggui |
AWG |
c1ioo |
c1sus |
c1iscex |
RFM |
Dolphin RFM |
Sim.Plant |
Frame builder |
TDS |
|
|
|
|
|
|
|
|
|
|
|
|
|
7577
|
Fri Oct 19 00:55:35 2012 |
Jenne | Update | Computers | c1lsc is down (at least all of the models) |
When Evan and I were dithering the BS and ITMY (see his elog), I noticed that c1lsc was acting weird. the IOP was the only one with the blinky heartbeat. The IOP was all green lights, but all the other models had red for the fb connection, as well as the rightmost indicator (I don't know what that one is for). I logged on to c1lsc and ran 'rtcds restart all'. The script didn't get anywhere beyond saying it was beginning to stop the 1st model (sup, the bottom one on the lsc list). Then all of the cpus went white. I can still ping c1lsc, but I can't ssh to it.
I'm not sure what to do here Jamie. Heelp. |
8367
|
Thu Mar 28 12:50:52 2013 |
Jenne | Update | Computers | c1lsc is fine |
Manasa told me that she did things in a different order than her old elog.
She had
(1) ssh'ed to c1lsc and did a remote shutdown / restart,
(2) restarted fb,
(3) restarted the mxstream on c1lsc,
(4) restarted each model individually in some order that I forgot to ask.
However, with the situation as in her "before" screenshot, all that needed to be done was restart the mxstream process on c1lsc.
Anyhow, when I looked at the OAF model, it was complaining of "no sync", so I restarted the model, and it came back up fine. All is well again. |
7580
|
Fri Oct 19 12:45:12 2012 |
Den | Update | CDS | c1lsc is up after reboot |
|
6243
|
Fri Feb 3 10:48:24 2012 |
Den | Update | Computers | c1lsc kernel |
This morning I killed again c1lsc kernel with the new realization of fxlms algorithm. It works fine with gcc compiler during the tests. However, smth forbidden for the kernel is going on. I'll spend some more time on investigatin it. Interesting thing is that I did not even pressed "On" at the OAF MEDM screen to make the code running. c1lsc suspended even before. May be there is some function-name mismatch.
After c1lsc suspention I recomiled back non-working code and rebooted c1lsc. c1sus is also bad after c1lsc reboot as they communicate. I killed x04, lsc, ass, oaf models on the c1lsc computer and sus, mcs, rfm, pem on the c1sus computer. Then I restarted x02 model and restored its burt snapshot from 08:07. After I started all models back and restored their burt snapshots from 08:07. Then I diag reset all started models.
Before starting new fxlms code I've shutted down all the optics so that possible c1lsc suspention would not make them crazy. After reboot I turned the coils back. Everything seems to work fine. |
6249
|
Fri Feb 3 17:29:28 2012 |
Den | Update | Computers | c1lsc kernel |
The reason I've killed the c1lsc kernel was the following - when the code starts to run, it initializes some parameters and this takes ~0.2 msec per dof. Now, the old code did nothing with a DOF if C1:OAF-ADAPT_???_ONOFF == OFF. My code still initialized the parameters but then does nothing because no witness channels are given. But it spends 8*0.2 = 1.6 msec for initializing all 8 dof. As the code is called with frequency 2k, this was the reason for crashing. Now I've corrected my code, it compiles, runs and does not kill c1lsc. However, the old code would also kill the kernel if all DOF are filtered. So, when we'll use all 8 DOF, we'll have to split variable initialization.
But this is not the biggest problem. C1OAF model must be corrected, because, as for now, all 8 DOF call the same ADAPT_XFCODE function. As this function uses static variables, they will be all messed up by different DOF signals. |
4749
|
Thu May 19 16:46:20 2011 |
kiwamu | Update | LSC | c1lsc model : input channels rearanged |
According to Suresh's LSC rack design I rearranged the input channels of the c1lsc model such that the analog signals and the ADC channels are nicely matched.
Also I updated the c1lsc model in the svn with a help from Joe. The picture below is a screen shot of the input channels in the model file after I edited it.

|
14146
|
Wed Aug 8 23:03:42 2018 |
gautam | Update | CDS | c1lsc model started |
As part of this slow but systematic debugging, I am turning on the c1lsc model overnight to see if the model crashes return. |
11809
|
Wed Nov 25 14:46:53 2015 |
gautam | Update | CDS | c1lsc models restarted |
I noticed that all the models running on C1LSC had crashed when I came in earlier today. I restarted all of them by ssh-ing into C1LSC and running rtcds restart all. The models seem to be running fine now. |
8335
|
Mon Mar 25 11:42:45 2013 |
Jamie | Update | Computers | c1lsc mx_stream ok |
I'm not exactly sure what the problem was here, but I think it had to do with a stuck mx_stream process that wasn't being killed properly. I manually killed the process and it seemed to come up fine after that. The regular restart mechanisms should work now.
No idea what caused the process to hang in the first place, although I know the newer RCG (2.6) is supposed to address some of these mx_stream issues. |
8334
|
Mon Mar 25 09:52:22 2013 |
Jenne | Update | Computers | c1lsc mxstream won't restart |
Most of the front ends' mx streams weren't running, so I did the old mxstreamrestart on all machines (see elog 6574....the dmesg on c1lsc right now, at the top, has similar messages). Usually this mxstream restart works flawlessly, but today c1lsc isn't working. Usually to the right side of the terminal window I get an [ok] when things work. For the lsc machine today, I get [!!] instead.
After having learned from recent lessons, I'm waiting to hear from Jamie. |
1235
|
Fri Jan 16 18:33:54 2009 |
Yoichi | Summary | Computers | c1lsc rebooted to fix 16Hz glitches |
Kakeru, Yoichi
There were 16Hz harmonics in the PD3 and PD4 channels even when there is no light falling on it.
Actually, even when the connection to the ADC was removed, the 16Hz noise was still there.
Rob suggested that this might be digital problem, because data is sent to the daq computer very 1/16 of a second.
We restarted c1lsc and the problem went away. |
4124
|
Fri Jan 7 12:01:39 2011 |
Osamu | Update | Computers | c1lsc running |
I got a new adapter board for expansion chassis from CDS and exchanged the existing adapter board which was laid on the floor around ETMX to new one.
Then I connected the chassis to c1lcs, c1lsc seems to be running now. I will return the old board to CDS since Rolf says he wants to return it to manufacture.
I found an interface box from ADC to D-SUB37pin and a cable to connect them.
I needed to make cables to connect the interface box to existing LSC whitening filters that has a 37 pin female D-SUB connector on one end and a 40pin female flat connector on the other end. We should use shielded cables for them, but unfortunately CDS did not have right one. Temporarily I made one cable for 1-8ch using a ribbon twist cable like Joe did.
I found a saturation at ch5 of ADC0 on c1lsc. I did not check carefully but it seemed to come from the LSC whitening board. Input of ch5 of the whitening board was not terminated and had a huge output voltage, but also ch6 was not terminated and had no big output. I guess something wrong on the LSC whitening board. Needs to be checked. Anyway I unplugged the small ribbon cable between the whitening board and the next LSC AA filter board.
Finally I realized that fiber connection of RFM did not exist. What I saw was the fiber cable of Dolphin. We need a RFM PCIe interface board, and a long fiber cable between c1lsc and RFM hub. |
6716
|
Wed May 30 18:08:40 2012 |
Jamie | Update | LSC | c1lsc: add error point pick-offs, moved ctrl pick-offs after feedforward |
I made some modifications to the c1lsc model in order to extract both the error and control signals.
I added pick-offs for the error signals right before IFO DOF filter modules. These are then sent with GOTOs to outputs.
I also modified things on the control side. The OAF stuff was picking off control signals before feedforward in/outs. After discussing with Jenne we decided that it would make sense for the OAF to be looking at the control signals after feedforward. It also makes sense to define the control signal after the feedforward. These control signals are then sent with GOTOs to another set of outputs.
Finally, I moved the triggers to after the control signal pickoffs, and right before the output matrix. The final chain looks like (see attachment):
input matrix --> power norm --> ERR pickoff --> DOF filters --> FF out --> FF in --> CTRL pickoff --> trigger --> output matrix
The error pickoff outputs in the top level of the model are left terminated for the moment. Eventually I will be hooking these into the new c1cal calibration model.
The model was recompiled, installed, and restarted. Everything came up fine. |
Attachment 1: LSCchain.png
|
|
6734
|
Thu May 31 22:13:08 2012 |
Jamie | Update | CDS | c1lsc: added remaining SHMEM senders for ERR and CTRL, c1oaf model updated appropriately |
All the ERR and CTRL outputs in c1lsc now go to SHMEM senders. I renamed the the CTRL output SHMEM senders to be more generic, since they aren't specifically for OAF anymore. See attached image from c1lsc.
c1oaf was updated so that SHMEM receivers pointed to the newly renamed senders.
c1lsc and c1oaf were rebuilt, installed, and restarted and are now running. |
Attachment 1: lsc-shmem-out.png
|
|
11280
|
Mon May 11 13:21:25 2015 |
manasa | Update | CDS | c1lsp and c1sup not running |
I found the c1lsp and c1sup models not running anymore on c1lsc (white blocks for status lights on medm).
To fix this, I ssh'd into c1lsc. c1lsc status did not show c1lsp and c1sup models running on it.
I tried the usual rtcds restart <model name> for both and that returned error "Cannot start/stop model 'c1XXX' on host c1lsc".
I also tried rtcds restart all on c1lsc, but that has NOT brought back the models alive.
Does anyone know how I can fix this??
c1sup runs some the suspension controls. So I am afraid that the drift and frequent unlocking of the arms we see might be related to this.
P.S. We might also want to add the FE status channels to the summary pages. |
11282
|
Mon May 11 14:08:19 2015 |
manasa | Update | CDS | c1lsp and c1sup removed? |
I just found out that c1lsp and c1sup models no more exist on the FE status medm screens. I am assuming some changes were done to the models as well.
Earlier today, I was looking at some of the old medm screens running on Donatella that did not reflect this modification.
Did I miss any elogs about this or was this change not elogged??
Quote: |
I found the c1lsp and c1sup models not running anymore on c1lsc (white blocks for status lights on medm).
To fix this, I ssh'd into c1lsc. c1lsc status did not show c1lsp and c1sup models running on it.
I tried the usual rtcds restart <model name> for both and that returned error "Cannot start/stop model 'c1XXX' on host c1lsc".
I also tried rtcds restart all on c1lsc, but that has NOT brought back the models alive.
Does anyone know how I can fix this??
c1sup runs some the suspension controls. So I am afraid that the drift and frequent unlocking of the arms we see might be related to this.
P.S. We might also want to add the FE status channels to the summary pages.
|
|
11285
|
Tue May 12 08:51:08 2015 |
ericq | Update | CDS | c1lsp and c1sup removed? |
Quote: |
was this change not elogged??
|
This is my sin.
Back in Febuary (around the 25th) I modified c1sus.mdl , removing the simulated plant connections we weren't using from c1lsp and c1sup . This was included in the model's svn log, but not elogged. 
The models don't start with the rtcds restart shortcut, because I removed them from the c1lsc line in FB:/diskless/root/etc/rtsystab (or c1lsc:/etc/rtsystab ). There is a commented out line in there that can be uncommented to restore them to the list of models c1lsc is allowed to run.
However, I wouldn't suspect that the models not running should affect the suspension drift, since the connections from them to c1sus have been removed. If we still have trends from early February, we could look and see if the drift was happening before I made this change. |
13639
|
Fri Feb 16 22:15:30 2018 |
gautam | Update | General | c1mcs model restarted |
c1mcs had died for some reason. Looking at dmesg, I see:
[769312.996875] c1mcsepics[1140]: segfault at 7f5000000012 ip 00007f50ea8ded8f sp 00007f50e9f53a10 error 4 in libc-2.19.so[7f50ea865000+1a1000]
None of the other EPICS processes died. Not sure what to make of this. I was at the PSL table working, and had closed the PSL shutter to avoid MC autolocker trying to keep the MC locked while I was mucking about, but this shouldn't have had any effect on an EPICS process?
Anyway, I just logged into c1sus, stopped and restarted the model. IMC locks fine now. |