40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 271 of 341  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  10834   Tue Dec 23 13:18:37 2014 manasaUpdateGeneralX end AUX laser fiber setup

    

       
            
  
  10867   Wed Jan 7 12:15:17 2015 manasaUpdateGeneralNew RF cablesI was
working around the PSL table this morning.
1. I have fibers running from
  
  10873   Wed Jan 7 19:49:09 2015 manasaUpdateGeneralX end space issuesI have attached a photo of the ETMX table.
The path of the 1064nm light rejected after
the doubler and the green light are indicated
 ETMXspace.png 
  10883   Fri Jan 9 14:01:17 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nmI
worked around the PSL table today.

The Y+PSL output from the optical
  
  10884   Fri Jan 9 14:13:02 2015 manasaUpdateGeneralALS noise at ~30HzBefore starting to move things around the
PSL table, I measured the ALS out of loop noise
 ALSYoutLoop.pngLSC_TRY.png 
  10893   Tue Jan 13 10:28:02 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nm


  
  10895   Tue Jan 13 14:01:20 2015 manasaUpdateGeneralAUX Y + PSL beat note at 1064nm: needs work


  
  10918   Sat Jan 17 15:07:28 2015 manasaUpdateGeneralBeat note frequency discrepancyI
was around the PSL table and the X end table
today.
  
  10919   Mon Jan 19 11:03:32 2015 manasaUpdateGeneralRF connections to adderRF connections to the beat note adder on
the IOO rack have been undone and it
should be good to proceed with any locking
  
  10954   Thu Jan 29 09:50:47 2015 manasaUpdateElectronicsIOO rack amplifier panelThe RF amplifier panel on the IOO rack
(Attachment 1) will be used to also hold
the RF amplfiers for the frequency counters.
 panel_front.jpgpanel_back.jpg 
  10955   Thu Jan 29 10:14:21 2015 manasaUpdateGeneralX end space issuesIt is certain that we have space issues
at the X end that has been preventing us
from sticking in a lens to couple light into
 photo.pngdrawing.png 
  10956   Thu Jan 29 11:59:48 2015 manasaUpdateGeneralBeat note frequency discrepancyBelow is the set of plots comparing measurements
for the green and IR beat notes frequencies.
The measurements were made on the spectrum
 Freq_compare1.pngFreq_compare2.png 
  10957   Thu Jan 29 16:14:10 2015 manasaUpdateGeneralUpdated to do list for FOLSince there will be some work that supposedly
will involve moving stuff on the table and
racks; here is the updated to-do list for
 FOLtodolist1.png 
  10958   Thu Jan 29 17:20:58 2015 manasaConfigurationIOOX Trans Table less crazy but not enough yet[Koji, Manasa]

We cleared up some optics
and optomechanics at the X end table that
  
  10961   Fri Jan 30 11:37:20 2015 manasaFrogsTreasureSP table madness endsSP table has been a mess because Q and
I had let our SURF leave without cleaning
up.
 before_after.jpgsort.jpg 
  10964   Mon Feb 2 16:58:56 2015 manasaUpdateGeneralRF amplifier for ALSToday I was around the IOO rack.

I shutdown the power to the beat
PDs on the PSL table and disconnected the
 ALSXY_outLoop.png 
  10970   Tue Feb 3 16:43:48 2015 manasaUpdateGeneralRF amplifier for ALSI pulled out the RF amplifier box from
the IOO rack again and added the new
RF amplifiers for FOL. 
  
  10977   Wed Feb 4 21:05:24 2015 manasaUpdateGeneralRF amplifier for ALSThe components of the RF amplifier
box are in place. The RF amplifier box has
been mounted on the IOO rack and the front
 RFampBox.png 
  10978   Wed Feb 4 21:09:43 2015 manasaUpdateGeneralX endtable work scheduled tomorrowThe X end fiber setup will be put together
tomorrow morning.
  
  10981   Thu Feb 5 15:21:25 2015 manasaUpdateGeneralX endtable work [EricG, Manasa]

We were at the X end today trying
to couple AUX X light into the fiber. 
  
  10985   Fri Feb 6 18:06:18 2015 manasaUpdateGeneralFiber Optic module for FOLI pulled out the Fiber Optic Module for
FOL from the rack inside the PSL table enclosure
and modified it. The beat PDs were moved
 FOLfiberModule.png 
  10995   Tue Feb 10 13:48:58 2015 manasaUpdateLSCProbable cause for headaches last nightI
found the PSL enclosure open (about
  
  10996   Tue Feb 10 16:01:21 2015 manasaUpdateGeneralAUX X fiber coupled 72%Plan
C finally worked. We have
 AUXxTelescope.png 
  11006   Wed Feb 11 18:44:53 2015 manasaUpdateGeneralOptical fiber moduleI have moved the optical fiber
module for FOL to the PSL table. It is setup
on the optical table right now for testing.
  
  11013   Thu Feb 12 12:16:04 2015 manasaUpdateGeneralFiber shielding[Steve, Manasa]

The fibers around the PSL table
were shielded to avoid any tampering.
  
  11014   Thu Feb 12 12:23:21 2015 manasaUpdateGeneralWaking up the PDFR measurement system[EricG, Manasa]

We woke up the PDFR measurement
setup that has been sleeping since summer.
  
  11065   Wed Feb 25 11:01:05 2015 manasaUpdateComputer Scripts / ProgramsNew screen for FOL PID loopCreated a new medm screen C1ALS_FOL_PID.adl for
FOL PID loop control in 
  
  11075   Thu Feb 26 10:56:34 2015 manasaUpdateGeneralRunning cables[Steve, Manasa]

We ran power cables and sma cables
for the FOL fiber module from the PSL table
  
  11078   Thu Feb 26 16:37:21 2015 manasaFrogsLSCRIP illegal power supplyNo more illegal power supply at the LSC
rack 
  
  11079   Thu Feb 26 16:46:37 2015 manasaUpdateGeneralIOO rack power supplyI shutdown the +/-15V and the +/-24V sorensons
on the IOO rack to connect the FOL RF PDs
to the rack power supply.
  
  11101   Thu Mar 5 11:18:28 2015 manasaUpdateGeneralRF amplifier boxI pulled out the RF amplifier box from
the IOO rack and swapped the amplifiers
for FOL beat frequency amplification. The
  
  11102   Thu Mar 5 12:27:27 2015 manasaUpdateGeneralFOL fiber box on the PSL tableWorking
around the PSL table

I have put the FOL
  
  11110   Fri Mar 6 14:29:59 2015 manasaUpdateGeneralFOL troubleshooting[EricQ, Manasa]

Domenica:
Since Domenica
  
  11123   Mon Mar 9 14:43:31 2015 manasaUpdateGeneralFOL troubleshootingFiguring out the problem with
frequency counter readouts:

 FOL_trouble.pdfIMAG0341.jpgIMAG0342.jpg 
  11127   Tue Mar 10 14:47:05 2015 manasaUpdatePSLPMC relockedPMC was locked in a bad state. FSS slow
actuator adjust was at ~ -0.7 and PZT voltage
at ~45.
  
  11128   Tue Mar 10 17:48:07 2015 manasaUpdateGeneralFOL troubleshooting[Koji, Manasa]

This problem was solved by changing
the Frequency Counter range settings.
  
  11132   Wed Mar 11 15:35:38 2015 manasaUpdateGeneralWaking up the PDFR measurement systemI was around the 1Y1 rack today. Trials
were done to get the PDFR of AS55.

  
  11145   Thu Mar 19 14:37:17 2015 manasaConfigurationIOOIMC relockedThe autolocker was struggling to lock the
IMC. I disabled the autolocker and locked the
IMC manually. It seems happy right now. 
  
  11164   Tue Mar 24 10:53:30 2015 manasaUpdateGeneralScripts updated to the svnI found that the scripts in FOL and PDFR
directories were not in the svn. These were
added to the svn.
  
  11166   Tue Mar 24 15:22:12 2015 manasaUpdateComputer Scripts / ProgramsNew slow channels for FOL[Koji, Manasa]

I have created
new slow channels for FOL.
  
  11189   Wed Apr 1 11:42:30 2015 manasaUpdateComputer Scripts / ProgramsPID script in pythonSince none of us here are experts in pearl,
I have put together a python script
for a simple PID controller. This
  
  11199   Fri Apr 3 14:57:38 2015 manasaUpdateSUSBS oplevThe BS oplev has been misbehaving and kicking
the optic from time to time since noon. The
kicks are not strong enough to trip the watchdogs
 BS_oplev_Apr3.png 
  11209   Wed Apr 8 21:10:55 2015 manasaUpdateGeneralWaking up the PDFR measurement systemI was poking around with the PDFR hardware today.

I moved the Agilent which had its
screen projected on the monitor. I have put
  
  11235   Wed Apr 22 11:48:30 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signalSince the Frequency counters have not been
a reliable error signal for FOL PID loop,
we will put together an analog delay line
  
  11236   Wed Apr 22 14:56:18 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signal[Koji, Manasa]

Since the bandwidth of the fiber
PD is ~ 1GHz, we could design the frequency
  
  11270   Mon May 4 10:21:09 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signalAttached is the schematic of the analog
DFD and the plot showing the zero-crossing
for a delay line length of 27cm. The bandwidth
 DFD.pngDFD_resp.png 
  11272   Mon May 4 12:42:34 2015 manasaSummaryGeneralDelay line frequency discriminator for FOL error signalKoji suggested that I make a cosine fit
for the curve instead of a linear
fit.
 DFD_cosfit.png 
  11280   Mon May 11 13:21:25 2015 manasaUpdateCDSc1lsp and c1sup not runningI found the c1lsp and
c1sup models not running anymore on c1lsc
  
  11281   Mon May 11 13:26:02 2015 manasaUpdateIMCMC_F calibrationThe last MC_F calibration was done by Ayaka
: Elog
7823
  
  11282   Mon May 11 14:08:19 2015 manasaUpdateCDSc1lsp and c1sup removed?I just found out that c1lsp and c1sup models
no more exist on the FE status medm screens.
I am assuming some changes were done to the
  
ELOG V3.1.3-