  12656   Fri Dec 2 10:57:08 2016 steveUpdatePEM door seal replacedThe south end door leaky weather seals
replaced.

The aim is here to get some overpressure
 1_year_PEM.png 
  12657   Fri Dec 2 11:56:42 2016 gautamUpdateLSCMC1 LEMO jiggledI noticed 2 periods of frequent IMC locklosses
on the StripTool trace, and so checked the
MC1 PD readout channels to see if there were
 IMG_3474.JPGMC1_LR_dead.png 
  12659   Fri Dec 2 16:21:12 2016 gautamUpdateGeneralrepaired projector, new mixer arrived and installedThe most recent power outage took out our
projector and mixer. The projector was sent
for repair while we ordered a new mixer.
  
  12660   Fri Dec 2 16:40:29 2016 gautamUpdateIMC24V fuse pulled outI've pulled out the 24V fuse block
which supplies power to the AOM RF driver.
The way things are set up on the PSL table,
  
  12661   Fri Dec 2 18:02:37 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisELOG of the Wednesday work.

It turned out that the IMC WFS
demod boards have the PCB board that has
 WFS_demod_noise_orig.pdfWFS_demod_noise_mod.pdf 
  12662   Sat Dec 3 13:27:35 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisELOG of the work on Thursday

Gautam suggested looking at the
preamplifier noise by shorting the input
 WFS_demod_noise.pdfdemod.pdf 
  12663   Mon Dec 5 01:58:16 2016 gautamUpdateIMCIMC ringdownsOver the weekend, I worked a bit on getting
these ringdowns going. I will post a more
detailed elog tomorrow but here is a quick
 IMCringdown.pdfIMCringdown_2.pdf 
  12664   Mon Dec 5 15:05:37 2016 gautamUpdateLSCMC1 glitches are backFor no apparent reason, the MC1 glitches
are back. Nothing has been touched near the
PD whitening chassis today, and the trend
 Mc1glitches.png 
  12665   Mon Dec 5 15:55:25 2016 gautamUpdateIMCIMC ringdownsAs promised, here is the more detailed
elog.


Part
 7x 
  12666   Mon Dec 5 19:29:52 2016 gautamUpdateIMCIMC ringdownsThe MC1 suspension troubles vanished as
they came - but the IMC was remaining locked
stably so I decided to do another round of
 REFLanomaly.pdf 
  12667   Tue Dec 6 00:43:41 2016 gautamUpdateIMCmore IMC ringdownsIn an effor to see if I could narrow down
the cause of the 100kHz ringing seen in the
reflected PD signal, I tried a few things.
  
  12668   Tue Dec 6 13:37:02 2016 KojiUpdateIOOIMC WFS Demod board measurement & analysisI have implemented the modification to
the demod boards (Attachment 1).
Now, I am looking at the noise in
 demod.pdfWFS_error_noise.pdf 
  12669   Tue Dec 6 16:47:40 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
whitening board saids it is Rev B, but the
actual component values are more like Rev.
 D990196-C.pdf 
  12670   Tue Dec 6 17:54:08 2016 KojiUpdateIOOIMC WFS whitening filter investigationThe
input resistor 909Ohm of AD602 was shorted.
I've confirmed that the gain (= attenuation
 34.png 
  12671   Tue Dec 6 22:41:49 2016 KojiUpdateIOOIMC WFS whitening filter investigationI have implemented the same modification
(shorting the input resistor of AD602) to
the two whitening boards.
  
  12672   Wed Dec 7 11:52:48 2016 ericqUpdateIMCPartial IMC ringdownsThe transients are likely due to doppler
interference due to the input laser frequency
sloshing due to errant control signals after
 IMCpartial.pngIMCpartial.zip 
  12673   Thu Dec 8 07:56:05 2016 SteveUpdatePEMEQ6.5m Northen CANo damage. ITMY is glitching, so it has
not been damped.

 
 eq6.5FerndaleCA.png16d_glitching-_trend.pngEQ6.5_&4.7mFerndaleCa.png 
  12674   Thu Dec 8 10:13:43 2016 SteveUpdateLSCglitching ITMY_UL has a history 

 
 glitching__ITMY-UL_2007.png 
  12675   Thu Dec 8 19:01:21 2016 ranaUpdateIMCPartial IMC ringdownsMach Zucker on howto do Ringdowns:  https://dcc.ligo.org/LIGO-T900007   
  12676   Tue Dec 13 17:26:42 2016 KojiUpdateIOOIMC WFS whitening filter investigationRana pointed out that this modification
(removal of 900Ohm) leave the input impedance
as low as 100Ohm.
  
  12677   Wed Dec 14 19:16:57 2016 LydiaUpdateCDSAcromag Binary I/O testingI looked into converting the QPD whitening
switches for the X end to Acromag.


To test this out and be
  
  12678   Thu Dec 15 03:46:19 2016 ranaUpdateIOOIMC WFS whitening filter investigationhttps://dcc.ligo.org/LIGO-D1400414

As it turns out, its not so old
as I thought. Jenne and I reworked these
  
  12681   Thu Dec 22 09:37:20 2016 SteveUpdateVACRGA scan at day 63Valve configuration: vacuum normal

RGA head temp: 43.5 C

Vac envelope temp: 23 C
 pd80-d63.pngpd80-580Hz-d63.png 
  12687   Thu Dec 29 10:24:56 2016 SteveUpdatePEMEQ5.7mHawthorn NVSus damping restored.

 
 eq5.7HawthorneNV.png 
  12691   Thu Dec 29 21:48:32 2016 ranaUpdateIOOMC AutoLocker hung because c1iool0 asleep againMC unlocked, Autolocker waiting for c1iool0
EPICS channels to respond. c1iool0 was responding
to ping, but not to telnet. Keyed the crate
  
  12692   Fri Dec 30 10:27:46 2016 ranaUpdateDetCharsummary pages dead againDead again.
No outputs for the past month. We really
need a cron job to check this out
  
  12693   Thu Jan 5 21:43:16 2017 ranaUpdateDetCharsummary pages dead againMax tells us that soem conf files were
bad and that he did something and now some
pages are being made. But the PEM and MEDM
  
  12695   Sun Jan 8 12:47:06 2017 ranaUpdateGeneralOptical Layout in DCCManasa pointed me to the CAD drawings in
the 40m SVN and I've now uploaded them
to the 40m
  
  12696   Mon Jan 9 09:18:47 2017 SteveUpdatePEMpower glitchThere was a power glitch last night around
1:15am

The vacuum was not effected.
 MondayMorning.png 
  12697   Mon Jan 9 16:12:30 2017 SteveUpdateGeneralOptical Layout in DCCCaltech Facilities promissed to email the
40m facility drawings in Cad format.

I organized the old of optical
 drawings_on_paper.jpg 
  12698   Tue Jan 10 14:24:09 2017 SteveUpdateVACRGA scan at day 82Valve configuration: vacuum normal

Vacuum envelope: 23C

Rga head: 44C
 pd80VNd82.png 
  12699   Tue Jan 10 16:20:11 2017 SteveUpdateCDSpower glitch......Raid is rebuildingJamie started the fm40m Raid rebuilding.
It has been beeping since the power outage.

Summary pages have no reading since
 rebuilding_in_progress.png 
  12700   Tue Jan 10 21:47:00 2017 ranaUpdateCDSpower glitchDoes "done" mean they are OK
or they are somehow damaged? Do
you mean the workstations or the front end
  
  12701   Tue Jan 10 22:55:43 2017 gautamUpdateCDSpower glitch - recovery stepsHere
is a link to an elog with the steps I had
to follow the last time there was a similar
  
  12702   Wed Jan 11 16:35:03 2017 gautamUpdateCDSpower glitch - recovery progress[lydia, ericq, gautam]

We set about following the instructions
linked in the previous elog. A few notes/remarks:
 powerGlitchRecoveryJan2017.png 
  12703   Wed Jan 11 19:20:23 2017 Max IsiUpdateSummary PagesDecember outageThe summary pages were not successfully
generated for a long period of time at the
end of 2016 due to syntax errors in the PEM
  
  12704   Thu Jan 12 02:45:53 2017 JohannesUpdateGeneralNext armloss stepsAs stated in elog
12618, using an oscilloscope to average
the reflected powers and thus circumventing
 ass_illustration.pdf 
  12708   Thu Jan 12 17:31:51 2017 gautamUpdateCDSDC errorsThe IFO is more or less back to an operational
state. Some details:


The IMC mirror excess motion
 DCerror.png 
  12709   Thu Jan 12 23:22:34 2017 ranaUpdateSummary PagesDecember outagePages still not working: PEM and MEDM blank.


Committed existing MEDM
grabbing scripts to SVN. Ran the cron job
  
  12710   Fri Jan 13 08:54:32 2017 JohannesUpdateGeneralDC PD installedI installed a DC PD (Thorlabs PDA 520)
in the beam path to AS55. I placed a 2"
 ASDCPD_up.jpgASDCPD_down.jpgscrambled_osci.jpg 
  12711   Fri Jan 13 10:53:03 2017 SteveUpdatePEMdoors are fixedControl room to outside door was
realigned. 

  
  12712   Fri Jan 13 14:18:28 2017 SteveUpdatePEMair condition fixedThe old control room AC  has been
stick in heating mode for
about 2 months. It's thermostate
 PEM_120d.png 
  12713   Fri Jan 13 14:33:00 2017 MAX (not Rana)UpdateSummary PagesDecember outagePEM config file was also lacking a section
named "summary", which is necessary
for all parent tabs; this has now been solved.
  
  12715   Fri Jan 13 21:41:23 2017 KojiUpdateCDSDC errorsI think I fixed the DC error issue

1. I added the leap second
(leapsecond ?) entry for 2016/12/31, 23:60:00
  
  12716   Fri Jan 13 23:39:46 2017 gautamUpdateGeneralETMX suspension electronics problems?[Koji,gautam]

After Koji's leap second fix,
we were playing around with the X arm locking.
  
  12718   Sat Jan 14 12:12:03 2017 ranaUpdateDAQminute trends missingDid we turn off minute trend writing in
one of the recent FrameBuilder debug sessions?
Seems we only have second trends in 2016.
  
  12719   Sat Jan 14 12:36:57 2017 ericqUpdateDAQminute trends missingYes, writing minute trends causes hourly
FB crashes in the current state of things.
The "raw" minute trending is turned
  
  12722   Mon Jan 16 18:54:01 2017 ranaUpdateSUSBS: whitening re-engagedFound that the BS whitening was off. Gautam
says that "it has always been that way"
and "there's nothing in the elog
 BSwhite.pdf 
  12725   Mon Jan 16 23:25:07 2017 gautamUpdateSUSMC1 SUS electronics investigation[rana,gautam]

Summary:


 20170116_231625.pngIMG_7175.JPGIMG_7174.JPG 
  12726   Tue Jan 17 20:39:30 2017 ranaUpdateComputer Scripts / Programsnodus web apache simlinks too softI tried to follow these instructions today
to make the Simulink Webview accessible:

controls@nodus|public_html
  
ELOG V3.1.3-