40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 270 of 344  Not logged in ELOG logo
ID Date Authorup Type Category Subject Text Attachments
  6405   Tue Mar 13 16:40:06 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of time: detailsHere
I describe the measurement of the sensing
matrix.
 lockins_MICH.png 
  6406   Tue Mar 13 16:56:19 2012 kiwamuUpdateLSCevolution of the sensing matrix in PRMI as a function of timeNext steps:

    Compare the obtained sensing
matrix with an Optickle model. Particularly
  
  6407   Tue Mar 13 19:14:40 2012 kiwamuUpdateLSCNoise estimatino in the REFL33Q as a MICH sensor
A feasibility study of the REFL33Q as a MICH
sensor was coarsely performed from the point
 NB_REFL33.png 
  6409   Wed Mar 14 03:34:44 2012 kiwamuUpdateSUSAdjustment of BS suspension output matrix : coupling from SIDE to POS[Rana / Kiwamu]
 We put some elements in the
 Untitled.png 
  6410   Wed Mar 14 04:03:37 2012 kiwamuUpdateIOOPZT1 and associate extra worksAs the PZT1 has not been functional, I
have been aligning the Y arm to the input
beam instead of aligning the beam to the
  
  6411   Wed Mar 14 04:19:51 2012 kiwamuUpdateLSCREFL33Q for MICH control : not good I tried the REFL33Q for controlling
MICH in the PRMI configuration (#6407)
 Untitled.png 
  6414   Wed Mar 14 13:16:50 2012 kiwamuUpdateLSCA correction on Noise estimatino in the REFL33QA
correction on the previous elog about the
REFL33Q noise:
  
  6426   Fri Mar 16 16:03:03 2012 kiwamuUpdateIOOMC alignment servo : put some offsets in the TRANS QPD signalThe
MC alignment servo wasn't great in the last
1 hour or so as it kept disturbing the MC
  
  6436   Thu Mar 22 16:45:06 2012 kiwamuUpdateCDSc1scx and c1scy not properly runningIt
seems that neither c1scx nor c1scy is working
properly as their ADC counts are showing
  
  6437   Thu Mar 22 17:35:59 2012 kiwamuUpdateLockingmode profiles of the POP and POX beams : not bright enoughI tried to measure the beam profiles at
the POP and POX ports as Koji mentioned in
his entry (#6421).
  
  6440   Fri Mar 23 01:59:59 2012 kiwamuUpdateIOOREFL beam currently unavilable[Suresh / Kiwamu]
Currently
the REFL beam is bypassed by additional mirrors
  
  6444   Mon Mar 26 15:15:16 2012 kiwamuUpdateIOOexpected beam profile of PRM reflectionI have estimated how the mode profile
of the PRM reflection should be, as shown
in the plot blow.
 expected_edit.png 
  6445   Mon Mar 26 16:25:44 2012 kiwamuUpdateIOOexpected v.s. measured beam profile of PRM reflection[Suresh / Kiwamu]
 We did the 2nd round of
the PRM reflection mode scan on Friday.
 PRMreflection.pngDSC_4001_small.jpg 
  6446   Mon Mar 26 18:04:43 2012 kiwamuUpdateIOOmode scan at the REFL portFor those who are interested in the
actual data, I attache the actual data in
zip file together with a python plot code.
 mode_profile.pngREFLmodescan.zip 
  6450   Tue Mar 27 02:46:28 2012 kiwamuUpdateIOOREFL beam availableThe dump and some temporary mirrors
were removed and now the REFL beam is available
again.
  
  6471   Fri Mar 30 10:20:51 2012 kiwamuUpdateLSClocking last nightI was trying to make the DRMI lock more
robust.
Increasing the gains of the oplev
  
  6474   Sat Mar 31 08:01:07 2012 kiwamuUpdateLSCDRMI measurementI have measured the sensing matrix of the
DRMI although the lock still doesn't stay
for a long time.
  
  6488   Thu Apr 5 06:27:51 2012 kiwamuUpdateLSCAS110 sideband monitor installed[Jenne / Kiwamu]

 We
  
  6489   Thu Apr 5 07:19:16 2012 kiwamuUpdateLSCDRMI locking I
tried locking the DRMI to the signal-extraction
condition with the new trigger by AS110.
 DRMI_2012Apr4_edit.png 
  6506   Sat Apr 7 01:56:05 2012 kiwamuUpdateLSCOSA signal in DRMI conditionIt wasn't a dream or illusion -- I was
locking the DRMI to the right condition last
Wednesday (#6489).
 OSA.png 
  6508   Sat Apr 7 06:58:34 2012 kiwamuUpdateLSCDRMI lock : lost good alignmentSomehow I lost the good alignment, where
the lock can be frequently acquired and hence
I didn't go further ahead.
  
  6512   Mon Apr 9 18:18:14 2012 kiwamuUpdateLSCDRMI time seriesHere is a time series when the DRMI is
being locked.
You can see that the AS110 goes up
 time_series1.png 
  7534   Fri Oct 12 01:56:26 2012 kiwamuUpdateGeneralAlignment situation of interferometer [Koji / Kiwamu]
 We have realigned the interferometer
except the incident beam.
  
  8866   Thu Jul 18 01:10:00 2013 kiwamuUpdateGreen LockingALS Y performance with the new whitening filter 
  
  9051   Thu Aug 22 10:20:32 2013 kiwamuUpdateLSCDRMI Locked for 1+ minute!!!!!!Wonderful
! I like the video -- the spatial
  
  2631   Tue Feb 23 13:37:04 2010 kiwamu and steveConfigurationVACventing the 40m vac envelopeKiwamu and Steve have started venting
the 40m vacuum envelope.
Preparation:
  
  2636   Tue Feb 23 19:07:43 2010 kiwamu and steveConfigurationVACvent is completed

    
        
 vent2010feb23.jpg 
  2444   Tue Dec 22 11:23:51 2009 kiwamu, SteveUpdateIOOMC relockedIn this morning I found MC unlocked.
Steve restored the watchdogs before
I found that.
  
  2707   Wed Mar 24 04:22:51 2010 kiwamu, mattUpdateGreen Lockingtwo NPRO PLL Now some pedestals, mirrors and lenses
are left on the PSL table, since we are on
the middle way to construct a PLL setup which
  
  2712   Wed Mar 24 15:59:59 2010 kiwamu, mattUpdateGreen Lockingleave PLL lockedMatt checked it in this morning and he
found it's been locked during the night.
 
  
  2706   Wed Mar 24 03:58:18 2010 kiwamu, matt, kojiUpdateGreen Lockingleave PLL lockedWe are leaving the PLL as it is locked
in order to see the long term stability.
And we will check the results in early morning
 DSC_1402.JPG 
  2714   Thu Mar 25 17:29:48 2010 kiwamu, mottUpdateGreen LockingPLL two NPROsIn this afternoon, Mott and I tried to
find a beat note between two NPROs which
are going to be set onto each end table for
  
  2462   Mon Dec 28 23:56:44 2009 kiwamu, ranaUpdateComputersadd the HILO drift channels to the burtThe HIGH and LOW channels are added into
the burt request file "/target/c1losepics/autoBurt.req".
These values are used to colorize
 Screenshot_DRIFTMON.png 
  2690   Sun Mar 21 20:08:20 2010 kiwamu, ranaUpdatePSLEOM wasit sizeWe
are going to set the waist size to 0.1 mm for
 waist.pngwaist.py.zip 
  2464   Tue Dec 29 04:28:27 2009 kiwamu, rana, haixingUpdateCamerasNew Video Switch InstalledWe have installed the new   
  2538   Thu Jan 21 11:08:30 2010 kiwamu, steveUpdateVACDry Pump replacement This morning I and Steve replaced 
the dry fore pump of TP3, which is located
under the y-arm.
 DSCN0428.JPG 
  5261   Thu Aug 18 10:17:04 2011 kiwamu, steveUpdateSUSoplevs reestablished at VertexKiwamu and Steve, from yesterday
PRM and BS oplev paths were relaid
after setting 1/2 OSEM voltages. The incident
  
  2676   Tue Mar 16 05:10:39 2010 kojiUpdateEnvironmentEarthquake, Mag 4.4 Some of the suspensions got watchdog tripped
-> enabled -> damped.
The MC mirrors got slightly misaligned.
 100316_MC_SUS.png 
  2894   Fri May 7 11:21:49 2010 kojiUpdate40m UpgradingNew improved design for the 11MHz photodiodeHow much is the width?

  
  3577   Wed Sep 15 16:00:26 2010 koji, steveUpdateMOPA We removed the Lightwave MOPA Controller
from 1X1 (south)  It was a real painfully
messy job to pull out the umbilical.
  
  3578   Wed Sep 15 16:12:35 2010 koji, steveUpdateMOPAMOPA Controller is taken out of the PSL rackWe removed the Lightwave MOPA Controller,
PA#102, NPRO206 power supply to make room
for the IOO chassy at 1X1 (south) rack.
 P1060843.JPG 
  3604   Fri Sep 24 00:56:35 2010 koji, taraUpdateElectronicstesting TTFSSWe
found that a transistor was broken from yesterday
spark too. We partially fixed TTFSS, and
  
  3607   Fri Sep 24 23:47:10 2010 koji, taraUpdateElectronicstesting TTFSS  Q3, a PZT2222A transistor,
on D0901846 is replaced by a GE-82. However,
the board is still not fully function.
  
  3617   Tue Sep 28 21:11:52 2010 koji, taraUpdateElectronicsFixing the new TTFSSWe
found a small PCB defect which is an excess
copper shorting circuit on the daughter board,
 before.jpgafter.jpgbefore.jpgafter.jpg 
  4777   Wed Jun 1 13:33:22 2011 koji, taraUpdateElectronicsTTFSS #7 We replaced GE81 by PZT2907A (PNP transistor)
in TTFSS #7, it's working fine.
  Last time I broke Q4 transistor,
 q4.png 
  3596   Thu Sep 23 02:23:04 2010 koji,taraSummaryElectronicsTesting new TTFSS I tested the new table top
frequency stabilization system(TTFSS), 
  
  7952   Tue Jan 29 10:59:37 2013 lazy personFrogsGeneralbetter plan 
 I propose we work around this
problem with giant
  
  4752   Fri May 20 01:02:50 2011 loose connection hunterUpdateSUSloose connection on ETMY rackThe
UL signal of the shadow sensor on ETMY went
to zero this evening. 
 ETMY_loose.png 
  3701   Tue Oct 12 23:35:12 2010 mafaldaUpdateComputerscelan-installed CentOS 5.5 on mafalda


   
        
            
  
  8769   Thu Jun 27 17:49:17 2013 manasaUpdateGreen Lockingc1als model edited

    

       
            
 ALS_PHASEcalib.pngBEATX_FINE.png 
ELOG V3.1.3-