40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 267 of 341  Not logged in ELOG logo
ID Dateup Author Type Category Subject Text Attachments
  13392   Wed Oct 18 17:34:09 2017 gautamUpdateSUSASDCSummary:

The signal path for the ASDC signal
is AS55
  
  13393   Wed Oct 18 19:17:42 2017 gautamUpdateGeneralPRC angular feedforwardLast night, I collected ~30mins of data
for the vertex seismometer channels and the
POP QPD PIT/YAW signals with the PRMI locked
 pop_feedforward_potential.pdf 
  13394   Wed Oct 18 23:11:53 2017 gautamUpdateCDSFEs unresponsiveThis happened again just now - it was roughly
this time when this happened last night as
well.
  
  13395   Thu Oct 19 15:42:03 2017 jamieSummaryLSCMICH/PRCL reconstruction neural network running on c1lscGabriele's
PRCL/MICH reconstruction neural network is
now running on c1lsc. 
 NN.pngC1DNN_GDS.pngC1DNN_CPU_METER.png 
  13396   Fri Oct 20 16:30:17 2017 gautamUpdateCDSFB1 installed on shelves[steve, jamie, gautam]

The machine that now serves as
out Frame Builder, FB1, was sitting on top
  
  13397   Mon Oct 23 09:17:41 2017 SteveUpdatePEMants alartDo not leave organic trash or food boxes
in the 40m to attrack ants !
 ants.jpgants2.jpg 
  13398   Tue Oct 24 16:22:53 2017 gautamUpdateCDSToy DARM model setup in c1tst[alex, gautam]

Alex is going to have an undergrad
work on a calibration optimization project
 TOY_DARM.pngTOY_DARM_SIMULINK.png 
  13399   Tue Oct 24 16:43:11 2017 SteveUpdateCDSslow machine bootfest[ Gautam , Steve ]

c1susaux
  
  13400   Tue Oct 24 20:14:21 2017 jamieSummaryLSCfurther testing of c1dnn integration; plugged in to DAQIn order to try to isolate CPU6 for the
c1dnn neural network reconstruction model,
I set the CPUAffinity in /etc/systemd/system.conf
 NN.pngc1dnn_out.png 
  13401   Wed Oct 25 09:32:14 2017 GabrieleSummaryLSCfurther testing of c1dnn integration; plugged in to DAQ


  
  13402   Fri Oct 27 09:34:20 2017 SteveUpdatePEMearthquakesLompoc 4.3M and 3.7M Avalon

 
 recentEQs.png 
  13403   Fri Oct 27 10:14:11 2017 SteveUpdateVACRGA scan at day 372Valve configuration: Vacuum normal

Note: Tp2 running at 75Krpm 0.25A
26C has a  load high pitch sound today.
 RGA_scan_d372.png 
  13404   Sat Oct 28 00:36:26 2017 gautamUpdateCDS40m files backup situation - ddrescueNone of the 3 dd backups I made were bootable
- at boot, selecting the drive put me into
grub rescue mode, which seemed to suggest
 415E2F09-3962-432C-B901-DBCB5CE1F6B6.jpegBFF8F8B5-1836-4188-BDF1-DDC0F5B45B41.jpeg 
  13405   Sun Oct 29 16:40:17 2017 ranaSummaryComputersdisk cleanupBacked up all the wikis. Theyr'e in
wiki_backups/*.tar.xz (because xz -9e gives
better compression than gzip or bzip2)
  
  13406   Mon Oct 30 08:08:06 2017 SteveUpdatesafetysafety trainingUdit Kahndelwal received 40m specific basic
safety traning on Friday, Oct. 27
  
  13407   Mon Oct 30 10:09:41 2017 SteveUpdateVACTP2 failed IFO pressure 1.2e-5 Torr at 9:30am




 tp2failed.pngifo_1.0E-5_Torrit.pngtp2failed2dago.png4days.png 
  13408   Mon Oct 30 11:15:02 2017 gautamUpdateCDSslow machine bootfest + vacuum snafuEurocrate key turning reboots today morning
for c1psl
  
  13409   Mon Nov 6 09:09:43 2017 SteveUpdateVACsetting up new TP2 turboOur new Agilent Technology TwisTorr
84FS AG rack controller ( English Manual
pages 195-297 )  RS232/485, product
  
  13410   Mon Nov 6 11:15:43 2017 gautamUpdateCDSslow machine bootfest + IFO re-alignmentEurocrate key turning reboots today morning
for
  
  13411   Mon Nov 6 18:22:48 2017 jamieSummaryLSCcurrent procedure for running c1dnn codeThis is the current procedure to start
the c1dnn model:

  
  13412   Tue Nov 7 17:45:05 2017 gautamUpdateLSCDRMI Nosie Budget v3.1Some days ago, I had tried to measure the
SRCL->MICH and PRCL->MICH cross couplings
using broadband noise injected between 120-180
 SRCL_MICH_whitenoise_tf.pdfPRCL_MICH_whitenoise_tf.pdfMICH_aux.pdfC1NB_disp_40m_MICH_NB_2017-10-08.pdf 
  13413   Tue Nov 7 22:56:21 2017 gautamUpdateLSCDRMI locking recoveredI hadn't re-locked the DRMI after the
work on the AS55 demod board. Tonight, I
was able to recover the DRMI locking with
 DRMI_7Nov20178.png 
  13414   Wed Nov 8 00:28:16 2017 gautamUpdateLSCLaser intensity coupling measurement attemptI tried measuring the coupling of PSL intensity
noise by driving some broadband noise bandpassed
between 80-300Hz using the spare DAC channel
 PSL_RIN.pdf 
  13415   Wed Nov 8 09:37:45 2017 ranaUpdateLSCDRMI Nosie Budget v3.1why no oplev trace in the NB ?




  
  13416   Wed Nov 8 09:59:12 2017 gautamUpdateLSCDRMI Nosie Budget v3.1The Oplev trace is missing for now, as
I have not re-measured the A2L coupling since
modifying the Oplev loop shape (specifically
  
  13417   Wed Nov 8 12:19:55 2017 gautamUpdateSUScoil driver series resistanceWe've been talking about increasing
the series resistance for the coil driver
path for the test masses. One consequence
 vthresh.pdf 
  13418   Wed Nov 8 14:28:35 2017 gautamUpdateGeneralMC1 glitches returnThere hasn't been a big glitch that
misaligns MC1 by so much that the autolocker
can't lock for at least 3 months, seems
 MC1_glitchy.png6AFDA67D-79B1-469C-A58A-9EC5F8F01D32.jpeg 
  13419   Wed Nov 8 16:39:24 2017 KiraUpdatePEMADC noise measurementGautam and I measured the noise of the
ADC for channels 17, 18, and 19. We plan
to use those channels for measuring the noise
 ADC-fit.pngIMG_20171108_162532.jpgIMG_20171108_162556.jpg 
  13420   Wed Nov 8 17:04:21 2017 gautamUpdateCDSgds-2.17.15 [not] installedI wanted to use the foton.py utility for
my NB tool, and I remember Chris telling
me that it was shipping as standard with
  
  13421   Thu Nov 9 10:51:37 2017 gautamSummaryLSCcurrent procedure for compiling and installing c1dnn codeJamie pointed out that the compile and
install instructions are different for c1dnn:

  
  13422   Thu Nov 9 15:33:08 2017 johannesUpdateCDSrevisiting Acromag


  
  13423   Fri Nov 10 08:52:21 2017 SteveUpdateVACTP3 drypump replacedPSL shutter closed at 6e-6 Torr-it    

   The foreline pressure
of the drypump is 850 mTorr at 8,446 hrs
  
  13424   Fri Nov 10 13:46:26 2017 SteveUpdatePEMM3.1 local earthquakeBOOM
SHAKA-LAKA
 3.1M_local_EQ.png 
  13425   Fri Nov 10 18:57:41 2017 ranaSummaryElectronicsIthaca 1201 vs. SR560I characterized the black
Ithaca 1201 pre-amp that we had sitting
in the racks. It works fine and the input
 Ithaca1201.pdf 
  13426   Tue Nov 14 08:54:37 2017 SteveUpdateIOOMC1 glitching   MC1_glitching.png 
  13427   Tue Nov 14 16:02:43 2017 KiraSummaryPEMseismometer can testingI made a model for our seismometer can
using actual data so that we know approximately
what the time constant should be when we
 time_const.png 
  13428   Wed Nov 15 01:37:07 2017 gautamUpdateLSCDRMI low freq. nosie improvedPianosa
just crashed and ate my elog, along with
 C1NB_disp_40m_MICH_NB_2017-11-15.pdfOL_A2L_couplings.pdf 
  13429   Thu Nov 16 00:14:47 2017 Udit KhandelwalUpdateSUSSOS Sapphire Prism designSummary:


SOS solidworks model is
nearly complete

Having trouble
  
  13430   Thu Nov 16 00:45:39 2017 gautamUpdateSUSSOS Sapphire Prism design 




  
  13431   Thu Nov 16 00:53:26 2017 gautamUpdateLSCDRMI noise sub-budgetsI've incorporated the functionality
to generate sub-budgets for the various grouped
traces in the NBs (e.g. the "A2L"
 C1NB_a2l_40m_MICH_NB_2017-11-15.pdfC1NB_aux_40m_MICH_NB_2017-11-15.pdf 
  13432   Thu Nov 16 13:57:01 2017 gautamUpdateOptical LeversOptical lever noiseI disabled the OL loops for ITMX, ITMY
and BS at GPStime 1194897655 to come up with
an Oplev noise budget. OL spots were reasonably
 VertexOLnoise.pdfITMYvsSRM.pdf 
  13433   Thu Nov 16 15:43:01 2017 ranaUpdateOptical LeversOptical lever noiseI bet the calibration
is out of date; probably we replaced the
  
  13434   Fri Nov 17 16:31:11 2017 aaronOmnistructureComputersAcromag wired upAcromag
Wireup Update

I
finished wiring up the Acromags to replace
 AcromagWiringMaps.pdf 
  13435   Fri Nov 17 17:10:53 2017 ranaOmnistructureComputersAcromag wired upExactly: you'll have to list explicitly
what functions those channels had so that
we know what we're losing before we make
  
  13436   Tue Nov 21 11:21:26 2017 gautamUpdateCDSRFM network downI noticed yesterday evening that I wasn't
able to engage the single arm locking servos
- turned out that they weren't getting
 RFMerrors.png 
  13437   Tue Nov 21 11:37:29 2017 gautamUpdateOptical LeversBS OL calibration updatedI calibrated the BS oplev PIT and YAW error
signals as follows:


Locked X-arm, ran dither
 OL_calib_BS_PERROR.pdfOL_calib_BS_YERROR.pdfVertexOLnoise_updated.pdf 
  13438   Tue Nov 21 16:00:05 2017 KiraUpdatePEMseismometer can testingI performed a test with the can last week
with one layer of insulation to see how well
it worked. First, I soldered two heaters
 cooling_fit.pngIMG_20171121_164835.jpg 
  13439   Tue Nov 21 16:28:23 2017 gautamUpdateOptical LeversBS OL calibration updatedThe numbers I have from the fitting don't
agree very well with the OSEM readouts. Attachment
#1 shows the Oplev pitch and yaw channels,
 BS_oplev_sweep.png 
  13440   Tue Nov 21 17:51:01 2017 KojiConfigurationComputersnodus post OS migration adminThe post OS migration admin for nodusa
bout apache, elogd, svn, iptables, etc can
be found in https://wiki-40m.ligo.caltech.edu/NodusUpgradeNov2017
  
  13441   Tue Nov 21 23:04:12 2017 gautamUpdateOptical LeversOplev "noise budget"Per our discussions in the meetings over
the last week, I've tried to put together
a simple Oplev noise budget. The only two
 vertexOL_noises.pdf 
ELOG V3.1.3-