40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 265 of 341  Not logged in ELOG logo
ID Date Author Type Categoryup Subject Text Attachments
  3042   Thu Jun 3 00:47:17 2010 KevinUpdatePSL2W Beam Profile of Second Reflected Beam[Koji, Kevin]

The profile of the Innolight 2W was
 profile_2nd.png 
  3109   Wed Jun 23 18:05:00 2010 KojiConfigurationPSLFSS SLOWDC should be ~-4.0FSS SLOWDC slider is at around 0.

Please someone relock this at ~-4.0 to exploit
 C1PSL_FSS.png 
  3110   Wed Jun 23 23:08:30 2010 ranaConfigurationPSLFSS SLOWDC should be ~-4.0 
  
  3163   Wed Jul 7 00:15:29 2010 tara,RanaSummaryPSLpower spectral density from RefCav transmitted beam I measured
the RC transmitted light signals here at
the 40m. I made all connections through
 RIN_rftrans.pngtara.png 
  3164   Wed Jul 7 10:42:29 2010 KojiSummaryPSLpower spectral density from RefCav transmitted beam How do you calibrate this to Hz/rtHz?

  
  3189   Fri Jul 9 20:16:19 2010 ranaSummaryPSLThings I did to the PSL today: Refcav, PMC, cameras, etc.I re-aligned the beam into the PMC. I got
basically no improvement. So I instead changed
the .LOW setting so that PMCTRANS would no
  
  3190   Sun Jul 11 20:11:48 2010 ranaSummaryPSLRC trend after the insulation removal   rc.png 
  3196   Mon Jul 12 14:22:36 2010 JenneSummaryPSLThings I did to the PSL today: Refcav, PMC, cameras, etc.


   
        
            
  
  3210   Tue Jul 13 21:04:49 2010 tara,ranaSummaryPSLTransfer function of FSS servo I
measured FSS's open loop transfer function.
 TF_FSS_ser.png 
  3232   Thu Jul 15 19:27:04 2010 ranaSummaryPSLRC trend after the insulation removal   Untitled.pnga.pngb.png 
  3240   Fri Jul 16 20:25:52 2010 MeganUpdatePSLReference Cavity InsulationRana and I
1) took the temperature sensors off
the reference cavity;
 DSC_2271.JPGDSC_2266.JPG 
  3241   Fri Jul 16 23:53:27 2010 RanaUpdatePSLReference Cavity InsulationFrom the trend, it seems that the Reference
Cavity's temperature servo is working fine
with the new copper foil. I was unable to
  
  3260   Wed Jul 21 15:43:38 2010 MeganSummaryPSLCopper Layer Thickness on the Reference CavityUsing the equation for thermal resistance
Rthermal = L/(k*A)
where k is the thermal conductivity
  
  3268   Thu Jul 22 14:07:20 2010 kiwamuUpdatePSLPSL front end machineIt
looks like something wrong happened around
the PSL front end.  One
 PSL-PMC2010-07-22.png 
  3269   Thu Jul 22 15:59:29 2010 AlbertoUpdatePSLPSL front end machine


   
        
            
  
  3270   Thu Jul 22 18:18:54 2010 AlbertoUpdatePSLProblem Solved


   
        
            
  
  3271   Fri Jul 23 00:13:11 2010 ranaUpdatePSLProblem NOT REALLY SolvedSo...who was working around the PSL rack
this morning and afternoon? Looks like there was
  
  3272   Fri Jul 23 08:15:59 2010 steveUpdatePSLref cavity ion pumpThe ref cavity ion pump was running at
7.7kV instead of 5kV
This Digitel SPC-1 20 l/s ion pump
  
  3280   Fri Jul 23 16:02:16 2010 RanaUpdatePSLReference Cavity InsulationThis is the trend so far with the copper
foil wrapping. According to Megan's calculation,
we need ~1 mm of foil and the thickness of
 Untitled.png 
  3282   Fri Jul 23 21:14:29 2010 RanaUpdatePSLReference Cavity InsulationI wrapped another ~3 layers onto there.
It occurs to me now that we could just get
some 2mm thick copper plates made to fit
  
  3346   Sun Aug 1 21:40:27 2010 ranaSummaryPSLFSS: SLOWDC responseI bet you thought that the NPRO slow actuator
response could be well represented by a pole
at ~0.1 Hz? Well, that's just what they want
 Untitled.png 
  3364   Thu Aug 5 00:17:41 2010 KojiUpdatePSLPSL preparation workWe start the work on the cables at around
the PSL table.
  
  3369   Thu Aug 5 17:59:23 2010 KojiUpdatePSLCable removal from the control room[Alberto, Kiwamu, and Koji]
We removed the BNC cables from the
control room. 
 IMG_2684.jpg 
  3370   Thu Aug 5 22:36:11 2010 KojiUpdatePSLPSL preparation workPSL preparation work

  
  3371   Fri Aug 6 08:09:15 2010 steveUpdatePSLPSL preparation work


   
        
            
  
  3381   Fri Aug 6 20:00:03 2010 KojiUpdatePSLPSL preparation workPSL preparation work report
Aug 6th
10am-5pm: (Steve
 PSL_cable_map.pdf 
  3383   Sat Aug 7 11:07:44 2010 KojiConfigurationPSLMC kept locked / PMC control gain reduced to +13dBJenne asked us to keep th MC locked
and let the seismometers happy through this
weekend.
  
  3391   Tue Aug 10 05:56:07 2010 KojiUpdatePSLPSL Table Lifting PreparationWork
on Aug 9th
Steve, Jenne,
Koji, Alberto, Aidan, Jan, Sharmila, Katherine
From
 IMG_2686.jpgIMG_2691.jpgIMG_2692.jpgIMG_2711.jpg 
  3451   Fri Aug 20 17:46:30 2010 ranaUpdatePSL40m PSL Upgrade Layout v0.3http://lhocds.ligo-wa.caltech.edu:8000/40m/PSL/LayoutUpgrade
P-pol = purple
S-pol = red
  
  3463   Tue Aug 24 12:03:57 2010 ranaUpdatePSLPSL Upgrade: Mode Matching from PMC to IMCI used the free software called 'ABCD'
for Mac to construct this mode matching solution
for going from the PMC to the IMC.
 40mPSL.pngScreen_shot_2010-08-24_at_6.07.43_PM.png 
  3469   Wed Aug 25 15:32:52 2010 ranaUpdatePSLPSL Upgrade: Mode Matching from PMC to IMCIn a manner similar to the now classic
'Mode Matching from PMC to  IMC' entry, I
have calculated the lenses and positions
 40mPSL.pngScreen_shot_2010-08-25_at_6.26.23_PM.png 
  3470   Wed Aug 25 15:42:01 2010 JenneUpdatePSLPSL Upgrade: Mode Matching from PMC to IMCThoughts on where to take the pickoff for
the SHG for the PSL-green?  We discussed
today at the meeting the possibility of putting
  
  3482   Fri Aug 27 22:09:37 2010 JenneUpdatePSLThe beginnings of the new PSL[Rana, Jenne]
Like
 phoenix.jpg 
  3483   Sat Aug 28 01:02:31 2010 ranaUpdatePSLThe beginnings of the new PSLIn fact, many of the mounts need
to be adapted to 4": the beefy
steering mirrors going into the PMC, the
  
  3487   Mon Aug 30 13:57:25 2010 KojiSummaryPSLPSL table vibrational performance after the upgradeJenne and Koji
Last week Jenne has put the accelerometers
on and under the PSL table immediately after
 PEM_100830_SPE.pdfPEM_100830.pdf 
  3488   Mon Aug 30 18:22:00 2010 ranaSummaryPSLPSL Enclosure is UNSTABLEThe lifting and resetting of the
BLUE PSL enclosure has made it unstable somehow.
When I push on it a little it rocks
  
  3491   Mon Aug 30 23:21:36 2010 ranaHowToPSL2W NPRO Mount designed with emachineshop.com softwareTo test out this website - emachineshop.com,
Jenne and I are designing some of the mounts
for the new beam height.
 LaserMount.png 
  3500   Tue Aug 31 19:46:00 2010 ranaUpdatePSLPSL upgrade update
    Steve is handling the mount
height increase for the PMC and RC steering
mirrors, as well as a mount (non-steerable)
  
  3502   Wed Sep 1 08:28:43 2010 KojiUpdatePSLPSL upgrade update


   
        
            
  
  3503   Wed Sep 1 08:36:59 2010 KojiHowToPSL2W NPRO Mount designed with emachineshop.com software1. I can not see whether the attaching
surface is flat or not.
It should have ~1mm step to avoid
  
  3511   Thu Sep 2 01:44:13 2010 JenneUpdatePSLPSL beam hitting the PMC![Rana, Jenne]
More PSL progress. 
The new laser was raised to a 4 inch
  
  3519   Fri Sep 3 06:55:42 2010 ranaUpdatePSLPSL beam hitting the PMC!NPRO
Koji and I inspected and photographed
the laser after opening up its case. I then
  
  3523   Fri Sep 3 23:42:34 2010 JenneUpdatePSLPSL update of the dayRana and I were poking around on the PSL
table today, getting a few more items raised
to the correct height.
  
  3525   Mon Sep 6 01:46:58 2010 ranaUpdatePSLPSL update of the dayTo bypass the polarizer issue, I just used
cubes. One I took from the FSS-Refcav path
and the other from the power control part
  
  3542   Wed Sep 8 00:01:07 2010 rana, valeraUpdatePSLPMC updateWe ran the cables for the PMC: The RF cable
for the 35.5 MHz drive was cheap and so we
swapped the 29.5 MHz cable for it.
  
  3543   Wed Sep 8 09:50:13 2010 ranaUpdatePSLPSL updateAlso, Kiwamu has modified the layout drawing
to add the green PLL stuff. This has collapsed
the reference cavity's wave function placing
  
  3544   Wed Sep 8 11:46:53 2010 kiwamuUpdatePSLupdate of the layoutI put some
green stuff on the layout drawing.
 40mPSL.png 
  3548   Thu Sep 9 05:58:04 2010 kiwamuUpdatePSLmode matching from PMC to IMC I started mode matching of the
beam going to IMC. The work is still going
on.
  
  3556   Fri Sep 10 02:35:30 2010 rana, kiwamu, valera, taraConfigurationPSLupdateOver the last couple nights we got the
beam into the FSS path and all the way to
the IMC and out onto the AP table.
 40mPSL.pdf 
  3558   Sat Sep 11 22:42:07 2010 valeraUpdatePSLPSL update- The PMC REFL PD was moved from the temporary
location to the one called for by the PSL
layout (picture attached). The leakage beams
 DSC_2502.JPGDSC_2505.JPG 
ELOG V3.1.3-