40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 264 of 344  Not logged in ELOG logo
ID Date Author Type Categorydown Subject Text Attachments
  15246   Wed Mar 4 11:10:47 2020 YehonathanUpdateComputersAllegra revivalAllegra had no network cable and no mouse.
We found Allegra'snetwork cable (black)
and connected it.
  
  15276   Fri Mar 13 20:00:50 2020 JonUpdateComputersLoopback monitoring for slow machinesSummary

Today
I finished implementing loopback monitors
of the up/down state of the slow controls
 Screen_Shot_2020-03-13_at_7.59.55_PM.png 
  15447   Wed Jul 1 18:16:09 2020 gautamUpdateComputersrossa re-re-revivalIn an effort to make a second usable workstation,
I did the following (remotely) on rossa today
(not necessarily in this order, I wasn't
 MCacc.pdf 
  15449   Sun Jul 5 16:14:41 2020 ranaUpdateComputersrossa re-re-revivalmaybe we should make a "dd" copy
of pianosa in case rossa has issues
and someone destroys pianosa by accidentally
  
  15451   Sun Jul 5 18:39:57 2020 ranaUpdateComputersrossa: printerI did

sudo usermod -a -G
  
  15452   Mon Jul 6 00:37:28 2020 gautamUpdateComputersrossa: lib symlinkThis is strange - I was definitely able
to launch medm when I was working on this
machine remotely on Friday. But now, there
  
  15454   Mon Jul 6 12:43:02 2020 ranaUpdateComputersrossa: lib symlinkyes, I rebooted yesterday to fix the 'steaking
white lines' problem in the video/display

maybe we're supposed to edit
  
  15455   Mon Jul 6 12:51:41 2020 gautamUpdateComputersrossa: resolvconf installedIndeed, this is now fixed by following
instructions from here.
I rebooted rossa at ~1250 PDT and confirmed
  
  15460   Wed Jul 8 22:50:33 2020 gautamUpdateComputersrossa: more symlinksI wanted to try using rossa as my locking
workstation today. However, a few problems
became quickly evident. Basically, any of
  
  15463   Thu Jul 9 16:16:20 2020 gautamUpdateComputersrossa: graphics driver issues?I noticed these streaky lines again today
(but they were not a problem last night).
It is annoying if we have to reboot this
  
  15469   Sat Jul 11 00:10:22 2020 gautamUpdateComputersrossa: more developmental workAfter some consultation with Erik von Reis
at LHO, this workstation is progressing towards
being usable
  
  15473   Mon Jul 13 11:33:18 2020 ranaUpdateComputersrossa: more developmental workI too, would prefer py3 for everything,
but aren't all the cdsutils / gaurdian
things still python2?
  
  15475   Mon Jul 13 12:37:05 2020 gautamUpdateComputersrossa: more developmental workIn fact, all these utilities are now available
in python3. There may be some bugs (e.g.
this),
  
  15921   Mon Mar 15 20:40:01 2021 ranaConfigurationComputersinstalled QTgrace on donatella for dataviewerI installed QTgrace using yum on donatella. Both Grace and  cutiegrace.png 
  15928   Wed Mar 17 09:05:01 2021 Paco, AnchalConfigurationComputers40m Control Room Changes
Switched positions of allegra and
donatella.
While doing so, the
hdmi cable previously used by donatella snapped.
  
  15945   Fri Mar 19 15:26:19 2021 AidanUpdateComputersActivated MATLAB license on megatronActivated MATLAB license on megatron   
  15946   Fri Mar 19 15:31:56 2021 AidanUpdateComputersActivated MATLAB license on donatellaActivated MATLAB license on donatella   
  15955   Tue Mar 23 09:16:42 2021 Paco, AnchalUpdateComputersPower cycled C1PSL; restored C1PSLSo actually, it was the C1PSL channels
that had died. We did the following to get
them back:
 MCWFS1and2PITYAW.pdfMCWFS1and2PITYAW_Zoomed.pdf 
  16027   Wed Apr 14 13:16:20 2021 AnchalConfigurationComputers40m Control Room Changes
I have confirmed that the old two
monitors' backlighting is not working.
One can see the impression of the display
  
  16249   Fri Jul 16 16:26:50 2021 gautamUpdateComputersDocker installed on nodusI wanted to try hosting some docker images
on a "private" server, so I installed
Docker on nodus following the instructions
  
  16287   Mon Aug 23 10:17:21 2021 PacoSummaryComputerssystem reboot glitch[paco]

At 09:34 PST I noted a glitch in
the controls room as the machines went down
  
  16307   Thu Sep 2 17:53:15 2021 PacoSummaryComputerschiara down, vac interlock tripped[paco, koji, tega, ian]

Today in the morning the name server
/ network file system running in chiara failed.
  
  16312   Thu Sep 2 21:21:14 2021 KojiSummaryComputersVacuum recovery 2Attachment 1:
We are pumping the main volume with
TP2. Once P1a reached the pressure ~2.2mtorr,
 Screenshot_2021-09-02_21-20-24.pngScreenshot_2021-09-02_21-20-48.png 
  16313   Thu Sep 2 21:49:03 2021 PacoSummaryComputerschiara down, vac interlock tripped[tega, paco]

We found the files that took excess
space in the chiara filesystem (see Attachment
 2021-09-02_21-51-15.png 
  16314   Fri Sep 3 02:03:15 2021 TegaSummaryComputersStrip down large error filesAlso deleted the ~50GB error files from
ldas to prevent rsync from copying them
to nodus again. With the new update to GWsumm,
  
  16346   Mon Sep 20 15:23:08 2021 YehonathanUpdateComputersWifi internet fixedOver the weekend and today, the wifi was
acting bad with frequent disconnections and
no internet access. I tried to log into the
  
  16348   Mon Sep 20 15:42:44 2021 Ian MacMillanSummaryComputersQuantization Code SummaryThis post serves as a summary and description
of code
to run to test the impacts of quantization
 472px-Typical_State_Space_model.svg.pngBiquad_filter_DF-IIx.svg.pngSS-IIR-TF.pdf 
  16350   Mon Sep 20 21:56:07 2021 KojiUpdateComputersWifi internet fixedUg, factory resets... Caltech IMSS announced
that there was an intermittent network service
due to maintenance between Sept 19 and 20.
  
  16355   Wed Sep 22 14:22:35 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryNow that we have a model of how the SS
and IIR filters work we can get to the problem
of how to measure the quantization noise
 IIR64-bitnoisespectrum.pdf 
  16360   Mon Sep 27 12:12:15 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI have not been able to figure out a way
to make the system that Aaron and I talked
about. I'm not even sure it is possible
  
  16361   Mon Sep 27 16:03:15 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI have coded up the procedure in the previous
post: The result does not look like what
I would expect. 
 DeltaNoiseSpectrum.pdf 
  16362   Mon Sep 27 17:04:43 2021 ranaSummaryComputersQuantization Noise Calculation SummaryI suggest that you


change the corner frequency
to 10 Hz as I suggested last week. This filter,
  
  16366   Thu Sep 30 11:46:33 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryFirst and foremost I have the updated bode
plot with the mode moved to 10 Hz. See Attachment
1. Note that the comparison measurement is
 SS-IIR-Bode.pdfPSD_32bit.pdfPSD_64bit.pdf 
  16481   Wed Nov 24 11:02:23 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI added mpmath
to the quantization noise code. mpmath allows
me to specify the precision that I am using
 PSD_IIR_all.pdf 
  16482   Wed Nov 24 13:44:19 2021 ranaSummaryComputersQuantization Noise Calculation SummaryThis looks great. I think what we want
to see mainly is just the noise in the 32
bit IIR filtering subtracted from the 64
  
  16492   Tue Dec 7 10:55:25 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation Summary[Ian, Tega]

Tega and I have gone through the
IIR
 DF2_TS.pdfBIQ_TS.pdfScreen_Shot_2021-12-07_at_11.47.57_AM.pngPSD_COMP_BIQ_DF2.pdfPSD_COMP_SS_DF2.pdf 
  16498   Fri Dec 10 13:02:47 2021 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI am trying to replicate the simulation
done by Matt Evans in his
presentation  (see Attachment
 G0900928-v1_(dragged).pdfPSD_COMP_BIQ_DF2.pdfInput_PSD.pdfInput_Filter.pdfQuantizationN.zip 
  16507   Wed Dec 15 13:57:59 2021 PacoUpdateComputersupgraded ubuntu on zita[Paco]

Upgraded zita's ubuntu and
restarted the striptool script.
  
  16650   Mon Feb 7 16:14:37 2022 TegaUpdateComputersrealtime system reboot problemI was looking into plotting temperature
sensor data trend and why we currently do
not have frame data written to file (on /frames)
  
  16656   Thu Feb 10 14:39:31 2022 KojiSummaryComputersNetwork security issue resolved[Mike P / Koji / Tega / Anchal]

IMSS/LIGO IT notified us that "ILOM
ports" of one of our hosts on the "114"
 PXL_20220210_220816955.jpgPXL_20220210_220827167.jpg 
  16836   Mon May 9 15:32:14 2022 Ian MacMillanSummaryComputersQuantization Noise Calculation SummaryI made the first pass at a tool to measure
the quantization noise of specific filters
in the 40m system. The code for which can
 SUS-ETMX_SUSYAW3_0.0.pdfLowNoiseBiquad2.pdfquant_noise_floor.pdf 
  16881   Fri May 27 17:46:48 2022 PacoSummaryComputersCDS upgrade visit, downfall and rise of c1lsc models[Paco, Anchal-remote, Yuta, JC]

Sometime around noon today, right
after cds upgrade planning tour, c1lsc FE
  
  16991   Tue Jul 12 13:59:12 2022 ranaSummaryComputersprocess monitoring: MonitI've installed Monit
on megatron and nodus just now, and will
set it up to monitor some of our common processes.
  
  17058   Thu Aug 4 19:01:59 2022 TegaUpdateComputersFront-end machine in supermicro boxesKoji and JC looked around the lab today
and found some supermicro boxes which I was
told to look into to see if they have any
 IMG_20220804_184444473.jpgIMG_20220804_191658206.jpgIMG_20220804_185336240.jpgIMG_20220804_185023002.jpg 
  17066   Mon Aug 8 17:16:51 2022 TegaUpdateComputersFront-end machine setupAdded 3 FE machines - c1ioo, c1lsc, c1sus
-  to the teststand following the instructions
in elog15947.
 IMG_20220808_170349717.jpg 
  17074   Wed Aug 10 20:51:14 2022 TegaUpdateComputersCDS upgrade Front-end machine setupHere is a summary of what needs doing following
the chat with Jamie today.

 
 IMG_20220810_171002928.jpgIMG_20220810_171019633.jpg 
  17083   Tue Aug 16 18:22:59 2022 TegaUpdateComputersc1teststand rack mounting for CDS upgrade[Tega, Yuta]

I keep getting confused about the
purpose of the teststand. The view I am adopting
 IMG_20220816_180157132.jpgIMG_20220816_175125874.jpg 
  17088   Wed Aug 17 11:10:51 2022 ranaUpdateComputersc1teststand rack mounting for CDS upgradewe want to be able to run SimPlant on the
teststand, test our new controls algorithms,
test watchdogs, and any other software upgrades.
  
  17098   Mon Aug 22 19:02:15 2022 TegaUpdateComputersc1teststand rack mounting for CDS upgrade II[Tega, JC]

Moved the rack to the location
of the test stand just behind 1X7 and plan
 IMG_20220822_185437763.jpgIMG_20220822_131340214.jpgc1bhd.jpegc1lsc.jpeg 
  17100   Tue Aug 23 22:30:24 2022 TegaUpdateComputersc1teststand OS upgrade - I[JC, Tega, Chris]

After moving the test stand front-ends,
chiara (name server) and fb1 (boot server)
  
ELOG V3.1.3-