ID Date Author Typeup Category Subject Text Attachments
  12274   Fri Jul 8 14:03:26 2016 ericqUpdateGeneralETMX removed from suspensionETMX is currently in the clean room, the
barrel is the tiniest bit submerged in acetone
that will remove a guide rod, standoff, and
 zoom.jpg 
  12275   Fri Jul 8 15:44:07 2016 PrafulUpdateElectronicsReplacing DIMM on OptimusOptimus' memory errors are back so
I found the exact DIMM model needed to replace:
http://www.ebay.com/itm/Lot-of-10-Samsung-4GB-2Rx4-PC2-5300P-555-12-L0-M393T5160QZA-CE6-ECC-Memory-/201604698112?hash=item2ef0939000:g:EgEAAOSwqBJXWFZh
  
  12276   Fri Jul 8 16:33:26 2016 ericqUpdateGeneralETMX removed from suspensionThe magnet, guide rod, and standoff came
off without too much force. However, some
epoxy residue remains on the barrel. I didn't
  
  12277   Fri Jul 8 19:33:16 2016 PrafulUpdateComputer Scripts / ProgramsMEDM Tab on Summary PagesA new MEDM tab has been added to the summary
pages (https://nodus.ligo.caltech.edu:30889/detcharsummary/day/20160708/medm/),
although some of the screens are not updated
  
  12278   Fri Jul 8 20:44:09 2016 KojiUpdateGeneralETMX removed from suspensionIn the evening, I went into the clean room
to check how it goes.

-
 6x 
  12279   Fri Jul 8 21:02:09 2016 KojiUpdateComputer Scripts / ProgramsMEDM Tab on Summary PagesVery nice!

Some of the screens are up-to-date,
and some are not. Are the errors associated
  
  12280   Fri Jul 8 21:15:03 2016 PrafulUpdateComputer Scripts / ProgramsMEDM Tab on Summary PagesThanks! Yes, only the screens that are
not updated when the script is executed show
this error. I'll try to keep debugging
  
  12281   Fri Jul 8 21:22:38 2016 gautamUpdateGeneralVent progress - ETMX SUS Coil driver electronics investigationWhile ETMX is out, I'm leaving
the larger amplitude excitations to the coils
on over the weekend, in case any electronic
  
  12282   Fri Jul 8 22:26:03 2016 varunUpdateCDSDAFI Update: Changes in LSC modelI have added the control signals DARM_CTRL,
MICH_CTRL, PRCL_CTRL, SRCL_CTRL, CARM_CTRL,
XARM_CTRL, YARM_CTRL, MC_CTRL to the
 lsc.pnglsctodaf.pnglsctodaf1.png 
  12283   Sun Jul 10 15:38:01 2016 ericqUpdateGeneralETMX in guiderod/standoff gluing fixtureI was hoping to glue a standoff and guide
rod today, but some problems have reared
their heads. Story follows:
 6x 
  12284   Sun Jul 10 15:54:23 2016 ericqUpdateCDSAll models restartedFor some reason, all of the non-IOP models
on the vertex frontends had crashed.

To get all of the bits green, I
  
  12285   Sun Jul 10 17:33:00 2016 ericqUpdateGeneralVent progressIt took a little time, but I relocked the
IMC and realigned to the point where the
PRC is flashing, visible on REFL and AS,
  
  12286   Sun Jul 10 18:20:39 2016 ranaUpdateElectronicsAntialiasing Filter UpdateComments on the schematic:


Only the instrumentation
amp should be made up of the ADA4004. Not
  
  12287   Sun Jul 10 20:08:44 2016 varunUpdateCDSDAFI Update: Changes in LSC and PEM modelsI have added the PEM signals mentioned
in the previous elog as DAF inputs through
PCIE IPC, and compiled and restarted the
 pemtodaf.pngpemindaf.png 
  12289   Mon Jul 11 15:13:22 2016 gautamUpdateGeneralVent progress: in-date First Contact procuredI have obtained 2x100cc bottles of in-date
first contact from Garilynn (use before date
is 09/14/2016) for cleaning of our test-masses.
 image.jpeg 
  12290   Tue Jul 12 09:18:12 2016 ericqUpdateGeneralSlippery substance mysteryI found a note on Steve's desk that R.
Abbott left yesterday afternoon about an
unidentified slippery substance being present
  
  12291   Tue Jul 12 09:35:51 2016 JohannesUpdateGeneralSlippery substance mysteryI've noticed the spot that Rich means
before, too. I think you only notice this
when you're wearing the shoe covers,
  
  12292   Tue Jul 12 16:08:00 2016 ericqUpdateGeneralETMX ruby guided gluing[ericq, Koji]

We have positioned and applied
epoxy to one ruby standoff on ETMX, for overnight
  
  12293   Tue Jul 12 18:13:19 2016 KojiUpdateVACN2 bottle replacedGautam, Koji

We replaced the right N2 bottle
as it was empty.
  
  12294   Tue Jul 12 20:16:15 2016 LydiaUpdateGeneralITMX dustLooked at ITMX. Johannes and I both saw
a fairly large speck of dust near the center
of the HR side. We tried to take some photos
  
  12295   Tue Jul 12 23:51:16 2016 JohannesUpdateGeneralVent progress - ETMY inspectionOn Monday I inspected ETMY, and found nothing
really remarkable. There was only little
dust on the HR side, and nothing visible
 IMG_2679.JPGIMG_2673.JPG 
  12296   Wed Jul 13 00:01:38 2016 JohannesUpdateGeneralITMX dustWe ran out of illuminator juice, and short-term
charging couldn't restore enough battery
life to continue the work. We should be able
  
  12297   Wed Jul 13 00:38:25 2016 JohannesUpdateGeneralVent progress - ETMY attempted repositioning[Lydia, Johannes]

We attempted to move the ETMY suspension
near the access port in preparation for the
  
  12298   Wed Jul 13 03:16:47 2016 KojiUpdateGeneralITMX dustMulticolor flash light:

- It seems that the usb port charging
doesn't work.
  
  12299   Wed Jul 13 15:35:56 2016 LydiaUpdateGeneralVent Progress - ETMY repositioned and removed[Lydia, Johannes]

Took
photos to document the original OSEM orientation
  
  12300   Wed Jul 13 21:13:51 2016 KojiUpdateGeneralETMX guide rod gluing / ETMY Magnet gluing[Eric, Koji]


ETMX: The Al guide
rod has been glued on the mirror.
ETMY:
 13x 
  12301   Thu Jul 14 01:00:33 2016 KojiUpdateGeneralETMX ruby guided gluingToday I took the picture of the glued ruby
stand-off. The groove has not been invaded
by the epoxy!
 ruby.jpg 
  12302   Thu Jul 14 22:29:57 2016 ericq UpdateGeneralETMX guide rod gluing / ETMY Magnet gluingThe pickle puckers came off ETMY cleanly  ETMY now rests   
  12303   Thu Jul 14 23:38:59 2016 varunUpdateCDSc1lsc FE unresponsiveToday, at around 10:30, c1lsc machine froze
and stopped responding to ping and ssh after
I compiled and restarted c1daf. I think it
  
  12304   Fri Jul 15 12:21:28 2016 varunUpdateCDSc1lsc FE unresponsivec1lsc is up and running, Eric did a manual
reboot today.

  
  12305   Fri Jul 15 16:23:51 2016 ericq UpdateGeneralGluing setbacks[ericq, Lydia]

Here is a picture of the ETMX guide
rod post-gluing. There is unfortunately a
 IMG_2768.JPGIMG_2771.JPG 
  12307   Sat Jul 16 00:30:42 2016 varunUpdateCDSDAFI update: Frequency warping | c1lsc unresponsiveSummary: I am trying to
implement frequency warping/pitch shifting
on the real time FE. Here is a description
  
  12308   Mon Jul 18 05:05:05 2016 AakashUpdateGeneralHeater for Seismometer Enclosure | SURF 2016I took off the silicon rubber heaters which
were used by a SURF last year for heating
the enclosure. The heater data sheet has
 HEATERS.jpegHEATERS.jpeg 
  12309   Mon Jul 18 18:44:52 2016 varunUpdateCDSc1lsc FE recoveredc1lsc FE is up and running.

Details:

2) The machine was manually rebooted.
 CDS_status160718.png 
  12310   Tue Jul 19 13:21:42 2016 JohannesUpdateGeneralVent progress - ETMY attempted repositioning[Lydia, Johannes]

We moved ITMY from its original
position to a place near the access point.
  
  12311   Tue Jul 19 15:16:43 2016 SteveUpdatesafetysafety trainingOur new graduate student Lydia received
40m specific safety training.
  
  12312   Tue Jul 19 15:30:08 2016 SteveUpdateGeneralHEPA dryer and dustI set up a simple HEPA filter dryer to
dry your clean room garment before 
you can put it away into your storage box.
 HEPAdryer.jpg 
  12313   Tue Jul 19 16:39:29 2016 LydiaUpdateGeneralETMX magnet gluing/guiderod excess glue removed[ericq, Lydia]

The epoxy arrived. Eric managed
to remove the excess glue below the
 P7190201.JPGP7190203.JPG 
  12314   Wed Jul 20 11:39:07 2016 SteveUpdateVACvent 78 day 20RGA background scan




 vent78-d20.png 
  12315   Wed Jul 20 13:58:55 2016 SteveUpdateSUSSUS damping out of vac chamberCheater
cable to be used in clean room pitch
gluing alingment.
 ETMXrack.jpgfromETMX-satBox.jpgsusDampingSatboxCab.jpgsusDampingSatboxCabl.jpg 
  12316   Wed Jul 20 14:03:01 2016 ericqUpdateSUSEffect of thicker ruby standoffsThe new ETMX ruby guide rods are slightly
thicker than the old aluminum ones; specifically
1.27mm vs 1.0mm.
  
  12317   Thu Jul 21 05:22:26 2016 AakashUpdateGeneralTemperature measurements across the enclosure | SURF 2016I have measured the transfer function of
temperature fluctuations inside the enclosure
to that of the temperature fluctuations outside.
 script21jul2016.mfig1.pdffig2.pdffig3.pdf 
  12318   Thu Jul 21 08:24:20 2016 SteveUpdatePEMants alartThe heat drives the ants to the lab! 
Make sure the light doors are tight on the
chambers.
 ants_Alart.jpg 
  12319   Thu Jul 21 12:03:35 2016 varunUpdateCDSDAFI update: Humming noise in DAFI output 


Summary: There
 New_Doc_13.pdf 
  12320   Thu Jul 21 14:27:24 2016 varunUpdateCDSDAFI Update: Arbitrary Math blockSummary: I have added
an arbitrary math block to the DAFI model,
which takes two inputs, say X and Y, and
 dafioverview.pngarbmath.png 
  12321   Thu Jul 21 15:03:13 2016 varunUpdateCDSDAFI Update1) I have added the status summary of the
DAFI block to the main FE status overview
screen in the c1lsc cloumn. (attachment 1)
 festatus.pngmatrices.png 
  12322   Thu Jul 21 17:01:59 2016 ericqUpdateGeneralETMX magnet gluing/guiderod excess glue removedOne step forward, two steps back...

While attempting to suspend ETMX,
I broke off a side magnet 
  
  12323   Thu Jul 21 21:38:44 2016 AakashUpdateGeneralTemperature measurements across the enclosure | SURF 2016I have made the changes as suggested by
Gautam.
  
  12324   Thu Jul 21 22:02:35 2016 varunUpdateCDSDAFI update: Frequency warpingThe code for frequency warping contained
a "printf()" command, which had
caused the system to crash in one another
 07212016.png 
  12325   Fri Jul 22 03:02:37 2016 KojiUpdateCOCFC painting[Koji Gautam]

We have worked on the FC painting
on ITMX and ITMY. We
 11x 