40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 263 of 344  Not logged in ELOG logo
IDup Date Author Type Category Subject Text Attachments
  13189   Fri Aug 11 00:10:03 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabledSeems
like something has failed after I did this
  
  13190   Fri Aug 11 10:27:49 2017 KiraUpdatePEMtemperature sensorSince there seems to be little difference
between AD590 and AD592, I guess we could
just go with the AD590. The temperature noise
  
  13191   Fri Aug 11 10:48:39 2017 KiraUpdatePEMtemperature sensorQuick update: we actually have AD587KRZ
and AD592, so we could start by using that
and seeing how it works.
  
  13192   Fri Aug 11 11:14:24 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabledI commented
out the line pertaining to C0EDCU again,
now full frames are being written
  
  13193   Fri Aug 11 11:56:02 2017 ranaUpdatePEMtemperature sensorMight as well order several of a few different
varieties today. Its good to have some extra
in stock; we don't always want to have
  
  13194   Fri Aug 11 12:27:25 2017 KiraUpdatePEMtemperature sensorUsed AD592CNZ and AD586 (5V output) to
create a circuit that works and is responsive
to temperature changes. At room temp, using
 IMG_20170811_121608.jpgIMG_20170811_121619.jpg 
  13195   Fri Aug 11 12:32:46 2017 gautamUpdateSUSMC1 glitches debuggingAttachment #1: Free swinging
sensor spectra. I havent done any peak fitting
but the locations of the resonances seem
 MC1_freeswinging.pdfMC1_inmatrix.pngMC1_sensors.png 
  13196   Fri Aug 11 17:36:47 2017 gautamUpdateSUSMC1 <--> MC3About 30mins ago, I saw another glitch
on MC1 - this
happened while the Watchdog was shutdown.
 MC1_glitch_watchdog_shutdown.png 
  13197   Fri Aug 11 18:53:35 2017 gautamUpdateCDSSlow EPICS channels -> Frames re-enabled


  
  13198   Fri Aug 11 19:34:49 2017 JamieUpdateCDSCDS final bits status updateSo it appears we now have full frames and
second, minute, and minute_raw trends.

We are still not able to raise
  
  13199   Sat Aug 12 14:09:36 2017 gautamUpdateSUSGlitches stay on MC1Even
in the switched state, the glitches stayed
on MC1. 

The coil
 MC1_glitch.pngMC_12hr_trend.pngMC1_glitches_intermittent.png 
  13200   Sat Aug 12 22:35:22 2017 ranaUpdateSUSGlitches stay on MC1To add to Gautam's entry: we swapped
the cables at the coil driver side (these
are the ones that go from coil driver to
  
  13201   Sun Aug 13 01:35:09 2017 KojiUpdateSUSGlitches stay on MC1We used to have similar suspension excursion
at ETMX. This was the motivation to replace
the stand-offs from Al ones to ruby ones.
  
  13202   Mon Aug 14 09:49:18 2017 KiraUpdatePEMtemperature sensorDecided to try adding in an OP amp just
to see if it would work. Added LT1012
and a 100k resistor to the circuit (I originally
 IMG_20170814_092452.jpgIMG_20170814_092513.jpg 
  13203   Mon Aug 14 12:52:33 2017 KiraUpdatePEMtemperature sensorI didn't realize that the LT1012 needed
an additional input to function. I added
in +15V and -15V to pins 7 and 4, respectively and
 IMG_20170814_121131.jpgIMG_20170814_121139.jpgIMG_20170814_121758~2.jpg 
  13204   Mon Aug 14 16:24:09 2017 gautamUpdateALSFiber ALSToday, I borrowed the fiber microscope
from Johannes and took a look at the fibers
coupled to the PDs. The PD labelled "
 IMG_7471.JPGIMG_7472.JPGIMG_7473.JPGIMG_7474.JPG 
  13205   Mon Aug 14 19:41:46 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsI'm upgrading the linux kernel for
all the front ends to one that is supposedly
more stable and won't freeze when we
  
  13206   Mon Aug 14 20:01:38 2017 gautamUpdateSUSGlitches stay on MC1I don't think we can say for sure. I
was just talking to EricQ about this, he
said the glitches were often seen when changing
  
  13207   Mon Aug 14 20:12:09 2017 Jamie, GautumUpdateCDSWeird problem with GPS receiverToday we saw a weird issue with the GPS
receiver (EndRun Technologies Tempus LX). 
GPS timing on fb1 (which is handled via IRIG-B
  
  13208   Tue Aug 15 08:22:16 2017 SteveUpdateGeneralprojector light bulb replacedBL-FS300C-PH-LE was
replaced after 2,904 hrs  It did
not explode this time.  The 4 monts
  
  13209   Tue Aug 15 11:50:21 2017 KiraSummaryPEMtemp sensor packaging/mountFor the final packaging/mounting of the
sensor to the seismometer, I have thought
of two options.
  
  13210   Tue Aug 15 13:32:38 2017 KiraUpdatePEMtemperature sensorTested to make sure that even when only
the AD586 was heated that there was no change
in the reading. I did so by placing the AD586
  
  13211   Tue Aug 15 16:32:42 2017 Jamie, GautumUpdateCDSGPS receiver apparently set to correct mode as "UTC"


  
  13212   Wed Aug 16 14:54:13 2017 gautamUpdateCDSPSL monitoring Acromag EPICS server restarted[johannes,
gautam, jamie]


Made a directory 
  
  13213   Wed Aug 16 14:57:01 2017 SteveUpdatePSLref Cavity heating blanket power supplyThe last entry I found relating to ref
cavity was
2011 Aug 19
 refCavPSheat.jpgrefCavTempSens.jpgrefTempSen_1X1.jpg 
  13214   Wed Aug 16 16:05:53 2017 KiraUpdatePEMtemp sensor PCBTried taking the circuit from the breadboard
to the PCB. I attached all the components
to adapters that would allow them to be connected
 IMG_20170816_154514.jpgIMG_20170816_154541.jpg 
  13215   Wed Aug 16 17:05:53 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsThe CDS system has now been up moved to
a supposedly more stable real-time-patched
linux kernel (3.2.88-csp) and RCG r4447 (roughly
 2017-08-16-163725_1366x495_scrot.png 
  13216   Wed Aug 16 17:14:02 2017 KojiUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsWhat's the current backup situation?   
  13217   Wed Aug 16 18:01:28 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errors


  
  13218   Wed Aug 16 18:06:01 2017 KojiUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errorsWe also need to copy chiara's root.
What is the best way to get the full image
of the root FS?
  
  13219   Wed Aug 16 18:50:58 2017 JamieUpdateCDSfront-end/DAQ network down for kernel upgrade, and timing errors


 2017-08-16-184910_1394x488_scrot.png 
  13220   Wed Aug 16 19:50:17 2017 gautamUpdateSUSMC1 <--> MC3 switched backNow that all the CDS overview lights are
green, I decided to switch back the coil
driver outputs to their original state so
  
  13221   Wed Aug 16 20:01:03 2017 gautamUpdateGeneralSUS model ASC input weirdnessI'm not sure if this has something
to do with the model restarts / new RCG,
but while I was re-enabling the MC watchdogs,
 ITMX_ASC.png 
  13222   Wed Aug 16 20:24:23 2017 gautamUpdateALSFiber ALSToday, with Johannes' help, I cleaned
the fiber tips of the photodiodes. The effect
of the cleaning was dramatic - see Attachments
 IMG_7476.JPGIMG_7477.JPGIMG_7478.JPGIMG_7479.JPG 
  13223   Thu Aug 17 08:42:27 2017 SteveUpdatePSLPSL HEPAThe PSL HEPA was running noisy at 100V  
The bearing is wearing out. I turned it down
to 30V It is quiet there.
  
  13224   Thu Aug 17 10:41:58 2017 KiraUpdatePEMtemp sensor PCBGot it to work. One of the connections
was faulty. I decided to check the temperature
measured against a thermometer. The sensor
 IMG_20170817_095917.jpg 
  13225   Thu Aug 17 11:17:49 2017 gautamUpdateSUSMC1 <--> MC3 switched backSeems like this modification didn't
really work. There were several large MC1
glitches, and one of them misaligned MC1
 MC1_misaligned.pngMC1_glitch.png 
  13226   Thu Aug 17 17:33:01 2017 gautamUpdateSUSMC1 <--> MC3 switched backthat's why the Autolocker clears the
outputs; we don't want to be holding
the offsets from the last ms of lock when
  
  13227   Thu Aug 17 22:54:49 2017 ericqUpdateComputersTrying to access JetStor RAID filesThe JetStor RAID unit that we had been
using for frame writing before the fb meltdown
has some archived frames from DRFPMI locks
  
  13228   Fri Aug 18 21:58:35 2017 gautamUpdateGeneralSUS model ASC input weirdnessI spent some time today trying to debug
this issue.

Jamie
 ITMXP.pngASC_model_outmatrix.pngASC_medm.pngASC_outMat.png 
  13229   Fri Aug 18 23:59:53 2017 gautamUpdateALSX Arm ALS lock[ericq, gautam]


I was just getting the
IFO aligned, and single arm lock going, when
  
  13230   Sat Aug 19 01:35:08 2017 ericqUpdateALSX Arm ALS lockMy motivation tonight was to get an up-to-date
spectrum of a calibrated measurement
of the out-of-loop displacement of an arm
 ALS_comparison.pdf 
  13231   Mon Aug 21 09:08:54 2017 SteveUpdateSUStiny glitchesThey are synchronised tiny glitches. They
are not mechanical.
 
 glitches.png 
  13232   Mon Aug 21 13:07:08 2017 KiraUpdatePEMtemp sensor PCBOn Friday, I cleaned up the circuit so
that there are only three connections needed
(+15V, -15V, GND) and a BNC connector for
 IMG_20170821_124121.jpgIMG_20170821_124429~2.jpgIMG_20170821_124108.jpg 
  13233   Mon Aug 21 14:53:32 2017 gautamUpdateVACRGA reset[gautam, steve]

In the aftermath of the accidental
vent, it looks like the RGA was shutdown.
  
  13234   Mon Aug 21 16:35:48 2017 gautamUpdateVACUPS checkup[steve, gautam]

At Rolf/Rich Abbott's request,
we performed a check of the UPS today.
  
  13235   Mon Aug 21 20:11:25 2017 johannesSummaryGeneralLoss measurements planThere are three methods we (will soon)
have available to evaluate the round-trip
dissipative losses in the arms that do not
  
  13236   Mon Aug 21 21:26:41 2017 gautamSummaryGeneralLoss measurements planIn case you want to use it, I had profiled
the Lightwave NPRO sometime back, and
we were even using it as the AUX X laser
  
  13237   Mon Aug 21 23:38:55 2017 gautamUpdateALSALS out-of-loop noiseI worked a little bit on the Y arm ALS
today. 


Started by locking the
 ALS_21082017.pdf 
  13238   Tue Aug 22 02:19:11 2017 gautamUpdateALSALS OLTFsAttachment #1 shows the
results of my measurements tonight (SR785
data in Attachment #2).
 ALS_OLTFs.pdfALS_OLTF_Aug2017.zip 
ELOG V3.1.3-