ID Date Author Type Categoryup Subject Text Attachments
  1078   Thu Oct 23 20:47:28 2008 peteConfigurationPSLFSS LO calibration for MEDMToday I took a quick series of measurements
to calibrate the FSS LO power measurement
in the MEDM.  This was done by using the
 fss_lo_calibration.png 
  1079   Thu Oct 23 21:52:27 2008 YoichiUpdatePSLFSS UGF now 450kHzI measured the open loop transfer function
of the FSS, for the first time after I mitigated
the oscillation.
 FSS_OPLTF.png 
  1080   Thu Oct 23 23:09:18 2008 YoichiUpdatePSLMC UGF is now 75kHzI measured three loop transfer functions of
the MC servo.
The blue curve in the first attachment is
 MC_Loop.pngOldAndNew.png 
  1083   Fri Oct 24 11:21:26 2008 peteConfigurationPSLFSS LO input calibrated in dBmBased on the measurements described in my
previous elog, I created a new calc record
in the file /cvs/cds/caltech/target/c1psl/psl.db
  
  1095   Mon Oct 27 14:48:27 2008 YoichiConfigurationPSLEO shutter installed to the reference cavityI'm now preparing for cavity ring down measurements
of the reference cavity.
An EOM for polarization rotation is installed
  
  1099   Wed Oct 29 12:23:04 2008 YoichiConfigurationPSLMZ alignment touched and the alarm level changedSince the MZ reflection is alarming all the
time, I tried to improve the MZ alignment
by touching the folding mirror.
  
  1107   Mon Nov 3 09:59:47 2008 steveUpdatePSLPSL HEPAs turned onThe psl [COLOR=chocolate]enclosure[/COLOR]
HEPAs were tuned on.
  
  1114   Tue Nov 4 17:58:42 2008 AlbertoDAQPSLMC temperature sensorI added a channel for the temperature sensor
on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1124   Fri Nov 7 18:38:19 2008 AlbertoDAQPSLMC temperature sensor hooked upAlberto, Rana,
we found that the computer handling the signals
from ICS-110B was C1IOVME so we restarted
  
  1130   Wed Nov 12 11:14:59 2008 CarynDAQPSLMC temp sensor hooked up incorrectlyMC Temperature sensor was not hooked up correctly.
It turns out that for the 4 pin LEMO connections
on the DAQ like J13, J14, etc. the channels
  
  1136   Fri Nov 14 19:20:42 2008 YoichiUpdatePSLReference cavity ring downThanks to Bob making the high-voltage BNC
cables for the HV pulse generator, I was
able to operate the EOM in front of
 RingDown.png 
  1137   Fri Nov 14 20:35:47 2008 ranaUpdatePSLReference cavity ring downTo make the DEI pulser make a fast pulse on
the EO shutter EOMs, we had to make sure:
  
  1138   Fri Nov 14 22:40:51 2008 YoichiUpdatePSLReference cavity ring down[quote]
To make the DEI pulser make a fast pulse
on the EO shutter EOMs, we had to make sure:
  
  1140   Mon Nov 17 15:07:06 2008 YoichiUpdatePSLReference cavity ring downI used MATLAB's system identification tool
box to estimate the response of the reference
cavity, i.e. cavity pole.
 Fit.png 
  1149   Thu Nov 20 09:37:39 2008 steveUpdatePSLMZ vs tempThis 12 days plot shows that it can hold lock
if the daily temp variation is not more than
3/4 of a degree C
 mztemp.jpg 
  1151   Fri Nov 21 16:11:26 2008 rana, alberto, robUpdatePSLMach Zender alignmentThe Mach Zender's dark port DC voltage had
gone up too high (~0.5 V)and was turning
yellow
 PB210051-1.JPG 
  1155   Fri Nov 21 20:29:43 2008 rana, alberto, robUpdatePSLMach Zender alignment[quote] So now the MZ alignment seems good;
Alberto is on the MC periscope alignment
like a cheap suit.[/quote]
  
  1160   Mon Nov 24 17:14:44 2008 ranaUpdatePSLMach Zender trendsIt looks like the MZ has gotten less drifty
after the alignment on Friday.
 Untitled.png 
  1162   Tue Nov 25 18:38:03 2008 Alberto, RobUpdatePSLMC Periscope AlignmentThis morning when I came in I found the MC
cleaner unlocked and the autolocker script
could not lock it. The reflected beam was
  
  1166   Tue Dec 2 17:56:56 2008 Alberto, RanaConfigurationPSLMC AlignmentIn the attempt to maximize the Mode Cleaner
transmission and minimize the reflection
from the steering mirrors of the MC periscope,
  
  1169   Wed Dec 3 11:58:10 2008 AlbertoUpdatePSLMC AlignmentRana, Alberto,

more details on the MC alignment we did yesterday.
  
  1190   Fri Dec 12 22:51:23 2008 YoichiUpdatePSLReference cavity ring down measurement againBob made new HV-cables with HV compatible
coaxes. The coax cable is rated for 2kV,
which was as high as Bob
 RC-Ringdown.png 
  1191   Tue Dec 16 19:06:01 2008 YoichiUpdatePSLReference cavity ring down repeated many timesToday, I repeated the reference cavity ring
down measurement many times to see how much
the results vary.
 RC_Ringdown_Estimates.pngCavity_Pole_Histogram.png 
  1228   Wed Jan 14 15:53:32 2009 steveDAQPSLMC temperature sensor[quote]I added a channel for the temperature
sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1244   Thu Jan 22 11:54:09 2009 AlbertoConfigurationPSLMach Zehnder Output Beam QPDI rotated by 180 degrees the 10% beam splitter
that it is used to fold the beam coming from
the Mach Zehnder (directed to the MC) on
  
  1246   Thu Jan 22 14:38:41 2009 carynDAQPSLMC temperature sensor[quote][quote]I added a channel for the temperature
sensor on the MC1/MC3 chamber: C1:PSL-MC_TEMP_SEN.
To do that I had to reboot the frame builder.
  
  1248   Fri Jan 23 10:00:21 2009 steveUpdatePSLPMC transmission is downThe PMC transmission is going down.
I have not relocked the PMC yet.
 pmc4d.jpg 
  1250   Fri Jan 23 14:00:02 2009 YoichiUpdatePSLPMC transmission is down[quote]The PMC transmission is going down.
I have not relocked the PMC yet.[/quote]
 LaserPower.png 
  1254   Wed Jan 28 12:42:51 2009 YoichiUpdatePSLMOPA dyingYoichi, Jenne, Peter

As most of you know, the MOPA output power
 Recent10Days.png126_MOPA.png 
  1256   Wed Jan 28 19:08:50 2009 YoichiUpdatePSLLaser is back (sort of)Yoichi, Peter, Jenne

Summary:
 Improving.png 
  1257   Thu Jan 29 13:52:34 2009 YoichiUpdatePSLLaser is back (sort of)Here is what I think has happened to the laser.

After the chiller line to the NPRO base clogged,
 SlowDC.pdf 
  1260   Thu Jan 29 18:10:13 2009 YoichiUpdatePSLISS BadKakeru, Yoichi

As we noted before, the ISS is unstable.
 OPLTF1.png 
  1262   Fri Jan 30 19:38:57 2009 KakeruUpdatePSLISS BadKakeru, Peter

We try to improve ISS bord, but there isn't
  
  1270   Tue Feb 3 23:44:44 2009 Kakeru, Peter, YoichiUpdatePSLISS unstabilityWe found that one OP-amp used in ISS servo
oscillated in 10 MHz, 100mV.
Moreover, we found another OP-amp
 TFgain.pngTFphase.png 
  1276   Thu Feb 5 21:42:28 2009 YoichiUpdatePSLMy thoughts on ISSToday, I worked with Kakeru on ISS.
The problem is sort of elusive. Some
time, the laser power looks fine, but after
 INMONPD_Spectrum_1-10Hz.pdf 
  1277   Fri Feb 6 09:52:35 2009 KakeruUpdatePSLCurrent shunt transfar functionI attach the transfar function of the current
shunt.
There is a little gap at 10 Hz for
 TF_CS_gain.pngTF_CS_phase.png 
  1278   Fri Feb 6 09:56:11 2009 KakeruUpdatePSLISS servo transfar functionI attache the transfar function of ISS
servo.
The 4th stage and variable gain amplifier
 TF_ISSservo_gain.pngTF_ISSservo_phase.png 
  1279   Fri Feb 6 10:46:40 2009 KakeruUpdatePSLISS servo and noiseI measured the output noise of eache stage
of ISS servo, and calcurated the noise ratio
between input and 
 ISS_servo_TF_noise.png 
  1281   Fri Feb 6 16:20:52 2009 YoichiUpdatePSLMOPA current slider fixedI fixed the broken slider to change the
current of the PA.
The problem was that the EPICS database
  
  1283   Fri Feb 6 23:23:48 2009 Kakeru, YoichiUpdatePSLISS is fixedYoichi and me found that the transfar function
of the current shunt changed with the current
of PA.
 Current_ShuntTF_gain.pngCurrent_ShuntTF_phase.png 
  1284   Mon Feb 9 16:02:42 2009 YoichiUpdatePSLPSL relative intensity noiseI attached the relative intensity noise of
the PSL.
There is no bump around the lower UGF (~1Hz),
 RIN-13dB.pngRIN-21dB.png 
  1287   Mon Feb 9 19:50:48 2009 YoichiConfigurationPSLISS disconnectedWe are doing measurements on ISS.
The ISS feedback connector is disconnected
and the beam to the MC is blocked.
  
  1289   Tue Feb 10 23:36:25 2009 KakeruUpdatePSLPA current and laser outputI changed the PA current and measured laser
output power (monitor PD signal).
The gain of ISS is 13dB
 PA_current_output.png 
  1291   Wed Feb 11 07:28:25 2009 YoichiUpdatePSLPA current and laser outputI think we should also plot the laser power
at the MOPA output. The horizontal axis should
be the absolute current value read from the
  
  1295   Wed Feb 11 23:51:53 2009 KakeruUpdatePSLPA current and laser outputI attached a plot of ISS monitor PD and MOPA
output to PA current.
The both end of PA current (26.0353[A] and
 PA_current_output.png 
  1299   Thu Feb 12 18:35:10 2009 KakeruConfigurationPSLPA current limitter
I added a PA current limiter.
It is only a voltage devider (composed
  
  1357   Wed Mar 4 23:42:45 2009 ranaConfigurationPSLpsl db changeI made   
  1395   Thu Mar 12 18:44:02 2009 YoichiUpdatePSLMZ alignedThe MC lost the alignment somehow this afternoon.
So I thought it was good time to touch the
MZ because I had to align the MC using the
  
  1421   Tue Mar 24 13:10:07 2009 AlbertoConfigurationPSLnew mirror installed on the AP tableNew flipping mirror installed on the AP
table on the beam path to the REFL199 PD.
If you're missing the double demod
  
  1431   Thu Mar 26 04:01:24 2009 YoichiUpdatePSLFSS Open Loop GainYoichi, Peter, Jenne

Attached is the open loop transfer function
 OpenLoopTF.png 
ELOG V3.1.3-