  2185   Thu Nov 5 22:30:09 2009 AlbertoUpdateLSCX Arm Cavity Transfer FunctionIt seems that just repeating the measurement
was enough to get a good transfer function
of the x arm cavity. Here's what I got.
 XarmTF01.png 
  2177   Wed Nov 4 23:17:51 2009 AlbertoUpdateLSCX Arm Cavity transfer FunctionI measured the transfer function between
MC_TRANS and TRX and I'm attaching the result.
 ArmCavityTF02.png 
  2178   Thu Nov 5 05:07:22 2009 ranaUpdateLSCX Arm Cavity transfer FunctionI would have guessed that you have to calibrate
the detectors relative to each other before
trying this. Its also going to be tricky
  
  2184   Thu Nov 5 19:25:11 2009 AlbertoUpdateLSCX Arm Cavity transfer Function


   
        
            
 PDA255CalibrationTF03.png 
  11328   Wed May 27 17:14:08 2015 ericqUpdateLSCX Aux Laser crystal temperature changedRana suspects that the lack of X beatnote
is related to the PSL laser temperature change
(ELOG
  
  6326   Mon Feb 27 18:35:45 2012 JenneUpdateGreen LockingX Beat SearchMeh.  I've searched in steps of 20
counts in C1:GCX-SLOW_SERVO2_OFFSET units
(16 bit +\- 10V DAC, and 1GHz/V coeffecient
  
  13366   Fri Oct 6 17:08:09 2017 SteveUpdateALSX End table beam traps correctedThere are no more double sided tape on
this table.

 
 c1.jpgc2.jpgc3.jpgc4.jpg 
  13326   Thu Sep 21 01:55:16 2017 ranaUpdateALSX End table of ShameImage #1: No - we do not use magnetic mounts
for beam dumps. Use a real clamp. It has
to be rigid. "its not going anywhere"
 20170921_003143.jpg20170921_002430.jpg20170921_002243.jpg20170921_001906.jpg 
  14125   Thu Aug 2 20:47:29 2018 gautamSummaryElectronicsX Green "Mystery" solvedI walked
down to the X end and found that the entire
  
  14127   Thu Aug 2 23:09:25 2018 ranaSummaryComputersX Green "Mystery" solvedI'm going to guess that this was me:
I was disconnecting some octopus power strip
nonsense down there (in particular illuminators
  
  13573   Wed Jan 24 00:58:59 2018 gautamUpdateALSX Green PDH modulation depthOn Friday, while Udit and I were doing
some characterization of the EX+PSL IR beat
at the LSC rack, I noticed that there were
  
  11191   Wed Apr 1 23:56:36 2015 ericqUpdateLSCX Green Power driftingSomething
funky is happening with the green
light locked to the X arm. The green transmitted
 Xgreen_drifting.png 
  11192   Thu Apr 2 01:28:34 2015 JenneUpdateLSCX Green Power driftingHave you tried a different set of laser
temperatures?  I don't remember
the value for the Xgreen, but whatever the
  
  11193   Thu Apr 2 01:45:44 2015 JenneUpdateLSCX Green Power drifting


  
  10951   Wed Jan 28 17:39:17 2015 KojiConfigurationIOOX Trans Table less crazy but not enough yetThe X-end IR Trans path was cleaned
up.

I have been investigating the Xarm
 IMG_1808.JPG 
  10958   Thu Jan 29 17:20:58 2015 manasaConfigurationIOOX Trans Table less crazy but not enough yet[Koji, Manasa]

We cleared up some optics
and optomechanics at the X end table that
  
  2226   Tue Nov 10 13:02:36 2009 AlbertoUpdateLSCX and Y Arm Cavity Poles MeasurementFrom fitting the arm cavity transfer functions
I got the following values for the cavity
pole frequencies.
 SummaryOfFits.pdfCodeAndData.tar 
  4795   Wed Jun 8 16:41:48 2011 valeraUpdateASSX and Y arm dither alignment status   BeamPositionIndicators.png 
  9621   Mon Feb 10 22:21:55 2014 manasaUpdateGreen LockingX and Y arm green tunedY arm green: Nothing
much was disturbed. I touched the steering
mirrors and brought 
  
  9633   Thu Feb 13 16:48:33 2014 SteveUpdateGreen LockingX and Y arm green tuned details

    

       
            
  
  9176   Mon Sep 30 17:55:45 2013 manasaUpdateGreen LockingX and Y arm transmission needs to be decoupled[Masayuki, Manasa]
Problem
We wanted to lock both the arms using
 scan2.png 
  87   Fri Nov 9 00:23:12 2007 pkpUpdateOMCX and Z resonancesI got a couple of resonance plots going for
now. I am still having trouble getting the
Y measurement going for some reason. I will
 Xtransferfunc.pdfZtransferfunc.pdf 
  12909   Mon Mar 27 16:01:55 2017 SteveUpdatePEMX arm AC set to 68F 

The X arm air conditioner was not
regulating properly. The arm temp was warmer
  
  8703   Thu Jun 13 22:31:12 2013 ManasaSummaryGreen LockingX arm ALSStabilized ALS
and beat frequency sweep realized.
 IMG_0659.JPGALS_stabilized_13June2013.png 
  8708   Fri Jun 14 07:06:19 2013 KojiSummaryGreen LockingX arm ALSIt's nice that we are now able to scan
the cavity again. We got close to PRMI+one
arm one step further.
  
  8824   Thu Jul 11 00:30:27 2013 manasaUpdateGreen LockingX arm ALS post-beatbox makeoverI ran a series of diagnostics on the X
arm ALS to look at how the beatbox behaves
after the makeover.
 XALS_inloop.pdfXALS_scan.pdfALS_outloop.pdf 
  14132   Fri Aug 3 19:02:11 2018 gautamUpdateASSX arm ASS recovery[koji,
gautam]

After I effected the series resistance
  
  14161   Tue Aug 14 00:50:32 2018 gautamUpdateASSX arm ASS still not quite right?While working on the single arm alignment,
I noticed that today, i was able to get the
X arm transmission back to ~1.22, and the
 POXPOY.pngIMG_7108.JPG 
  10865   Wed Jan 7 11:20:22 2015 SteveUpdateLSCX arm T-QPD gets SM1 thread adapterC1:SUS-ETMX_QPD is removed and internal
SM1 thread adapter epoxied into position
as it is at
  
  9594   Tue Feb 4 00:42:18 2014 KojiUpdateGeneralX arm aligned for IR/GRThe
X arm was also aligned for the IR by hand
and ASS. Also the X end green PZT was aligned
  
  6849   Thu Jun 21 15:36:51 2012 yutaUpdateLockingX arm alignmentI aligned X arm so that the beam spot comes
roughly on the center.
  
  4278   Sun Feb 13 15:02:23 2011 kiwamuUpdateGreen LockingX arm beam offcentering has been measuredThe amounts
of the X arm's beam off-centering have been
 misposition.png 
  8820   Wed Jul 10 11:27:02 2013 manasaUpdateGreen LockingX arm beatnote foundI found the beat note for X arm. I did
not change anything this morning (to the
best of my knowledge). Hooking up the spectrum
  
  8296   Thu Mar 14 17:31:57 2013 ManasaUpdateGreen LockingX arm green locked in TEM00

    

       
            
  
  8298   Fri Mar 15 01:57:02 2013 JenneUpdateGreen LockingX arm green locked in TEM00This work earlier today had required moving
the harmonic separator back closer to its
original position, so that the green could
  
  9233   Fri Oct 11 00:37:23 2013 manasaUpdateGreen LockingX arm green locking modes[Masayuki, Manasa]
We have stabilized the ALS for Y
arm and concluded that although the PDH servo
 MON4_1065505017.bmpMON4_1065504975.bmp 
  12478   Thu Sep 8 22:12:36 2016 gautamUpdateSUSX arm in place, locked to green, IR flashes visibleDetailed elog to follow but summary of
todays activities:


ITMX and ETMX are back
  
  11111   Fri Mar 6 14:51:59 2015 ericqUpdateGeneralX arm linewidth, lossThe fit FWHM is 10.444kHz
+-55Hz. 
 test.png 
  4191   Mon Jan 24 02:58:46 2011 kiwamuUpdateGreen LockingX arm locked !I succeeded in  time_series.pnggreen_one_arm.png 
  4192   Mon Jan 24 09:33:08 2011 ranaUpdateGreen LockingX arm locked !Very cool.
But the PLL seems very fishy to me.
The ZP-3MH needs 13 dBm to operate correctly.
  
  4193   Mon Jan 24 10:19:21 2011 KojiUpdateGreen LockingX arm locked !Well... The ALS loop is engaged and the
error was suppressed. 
So, how is the IR error signal stabilized
  
  4153   Fri Jan 14 01:55:26 2011 kiwamuUpdateLSCX arm locked with C1LSC digital control [Koji, Kiwamu]
  
  4156   Fri Jan 14 12:34:08 2011 KojiUpdateLSCX arm locked with C1LSC digital controlMy feeling was that the saturation was
caused by the LSC whitening filter which
was always on.
  
  5360   Wed Sep 7 17:28:41 2011 kiwamuUpdateLSCX arm loss measurement : not goodThe measurement
itself wasn't good.
 Xarmlossmeasurement.png 
  14552   Thu Apr 18 23:10:12 2019 gautamUpdateLoss MeasurementX arm misalignedYehonathan wanted to take some measurements
for loss determination. I misaligned the
X arm completely and we installed a PD on
  
  6859   Sat Jun 23 02:29:18 2012 yutaUpdateGreen LockingX arm mode scan resultsX
arm finesse is 416 +/- 6, mode-matching ratio
is 91.2 +/- 0.3%
 XarmScan20120623.pngfine8FSRscanXarm.png 
  10680   Thu Nov 6 12:53:09 2014 diegoUpdateASCX arm restored[Diego, Koji]
X arm has been restored, after modifying
the two parameters mentioned in http://nodus.ligo.caltech.edu:8080/40m/10676
  
  12474   Tue Sep 6 20:45:14 2016 gautamUpdateSUSX arm test masses back in chamber[Teng, Johannes,
Lydia, gautam]


The
 IMG_3137.JPGIMG_3143.JPGIMG_3142.JPGIMG_3148.JPG 
  10702   Wed Nov 12 15:14:09 2014 manasaUpdateGeneralX end AUX laser fiber setup I looked at the endtable for possible
space to setup optics in order to couple
the X end laser into a PM fiber.
 ETMXtable.png 
  10831   Mon Dec 22 17:06:14 2014 manasaUpdateGeneralX end AUX laser fiber setup

    

       
            
  