40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log, Page 262 of 341  Not logged in ELOG logo
Entry  Thu May 28 18:41:26 2009, steve, Update, PSL, the saga of the chiller is ending 
Entry  Fri May 29 18:57:09 2009, steve, Update, PSL, the laser is back laserisback.jpg
Entry  Sat May 30 11:24:56 2009, rob, Configuration, PSL, NPRO slow scan slowSCAN.png
Entry  Sat May 30 12:03:34 2009, rob, Update, PSL, MC locked 
Entry  Mon Jun 1 13:56:52 2009, Alberto, Update, PSL, Laser Power after fixing the laser chiller MOPAtrend.jpg
Entry  Mon Jun 1 14:49:07 2009, rob, Summary, PSL, psl thoughts 
    Reply  Mon Jun 1 15:01:31 2009, rana, Update, PSL, Laser Power after fixing the laser chiller: more traces Picture_7.png
    Reply  Mon Jun 1 19:19:26 2009, rana, Update, PSL, 1000 days of hour-trend u.png
Entry  Thu Jun 4 15:53:15 2009, steve, Update, PSL, NPRO cooling flowrate adjusted needlevalve.jpg
Entry  Wed Jun 10 09:28:14 2009, steve, Update, PSL, PMC pmctemphv.jpg
Entry  Wed Jul 8 19:13:19 2009, Alberto, Update, PSL, PSL beam aligned to the Mode Cleaner 
Entry  Wed Jul 22 10:49:40 2009, Alberto, Update, PSL, MC Alignment Trend 2009-07-21_MC-align-trend.pdf2009-07-22_mc-align-trend.pdf
Entry  Thu Jul 23 10:05:38 2009, Alberto, Update, PSL, Summary of the latest adventures with the alignment of the mode cleaner 
Entry  Thu Jul 23 20:30:23 2009, Alberto, Update, PSL, Beam aligned to the Farady 
Entry  Fri Jul 24 21:02:46 2009, Alberto, Update, PSL, Aligning the beam to the Faraday 
    Reply  Sat Jul 25 16:04:32 2009, rob, Update, PSL, Aligning the beam to the Faraday 
    Reply  Sat Jul 25 19:04:01 2009, Koji, Update, PSL, Aligning the beam to the Faraday MC2_Cam.jpg
    Reply  Sun Jul 26 13:19:54 2009, rana, Update, PSL, Aligning the mode cleaner Untitled.png
    Reply  Sun Jul 26 16:05:17 2009, Alberto, Update, PSL, Aligning the mode cleaner 
Entry  Wed Jul 29 11:58:57 2009, Alberto, Update, PSL, MC not locking 
Entry  Mon Aug 3 01:08:20 2009, Alberto, Update, PSL, MC unlocked 
    Reply  Mon Aug 3 12:57:09 2009, Alberto, Update, PSL, MC unlocked 
Entry  Wed Aug 5 16:33:50 2009, steve, Configuration, PSL, new PSL output iris psliris.png
Entry  Thu Aug 6 17:45:37 2009, Jenne, Update, PSL, HEPAs on high 
Entry  Thu Aug 6 18:26:26 2009, Jenne, Update, PSL, Ref Cav and PMC aligned 
    Reply  Thu Aug 6 19:54:04 2009, Stephanie, Update, PSL, HEPAs back to normal 
Entry  Thu Aug 6 23:29:47 2009, Jenne, Update, PSL, Ref cav reflection PD is funky 
    Reply  Fri Aug 7 00:10:14 2009, rana, Update, PSL, Ref cav reflection PD is funky 
Entry  Fri Aug 7 11:39:13 2009, Alberto, Update, PSL, MZ Alignment 
Entry  Fri Aug 7 14:31:39 2009, Alberto, Update, PSL, DAQ REstarted 
    Reply  Fri Aug 7 17:05:34 2009, Jenne, Update, PSL, Ref cav reflection PD is funky 
Entry  Sat Aug 8 15:08:14 2009, rana, Configuration, PSL, SMOO settings updated in psl.db and SVN updated 
Entry  Mon Aug 10 11:33:58 2009, Jenne, Update, PSL, Non-Elogged Beam dump on the PSL table - BadBadBad commodusthumbsdown.jpg
    Reply  Mon Aug 10 15:21:15 2009, Jenne, Update, PSL, Non-Elogged Beam dump on the PSL table - BadBadBad 
Entry  Mon Aug 10 15:24:17 2009, rob, Summary, PSL, MZ bad brokenMZpzt.png
    Reply  Mon Aug 10 15:56:12 2009, rob, Summary, PSL, MZ bad redux badMZtrans.png
Entry  Mon Aug 10 16:37:27 2009, rob, Update, PSL, MZ alignment touched 
Entry  Mon Aug 10 16:41:31 2009, Alberto, Configuration, PSL, PMC Visibility 
Entry  Mon Aug 10 20:49:13 2009, Alberto, Rana, Update, PSL, PMC Mode Matching Lenses Tuning 
Entry  Tue Aug 11 01:21:55 2009, rob, Update, PSL, MZ needs some attention badMZservo.png
Entry  Thu Aug 13 22:53:48 2009, Yoichi, Configuration, PSL, FSS nominal common gain changed, MC WFS centered 
Entry  Mon Aug 17 02:05:49 2009, Yoichi,rana, Update, PSL, Reference cavity reflection looks bad P8170113.JPGUntitled.png
    Reply  Mon Aug 17 04:16:13 2009, Yoichi, Update, PSL, Reference cavity reflection looks bad 
Entry  Tue Aug 18 01:16:01 2009, Jenne, Update, PSL, Mach Zehnder is realigned MachZehnderOptics2.pdf
Entry  Tue Aug 18 14:24:43 2009, Yoichi, Summary, PSL, Reference Cavity Inspection 
Entry  Tue Aug 18 15:52:27 2009, Jenne, Update, PSL, MZ 
    Reply  Tue Aug 18 19:57:47 2009, rana, Jenne, Update, PSL, MZ MZ_RFAMmon_setup_small.jpgMZ_RFAMmon_SpecAnalyzer_small.jpgMZ_EOM_IRrefl2_small.jpg
Entry  Tue Aug 25 11:02:39 2009, rana, Summary, PSL, Temperature Box D980400-B.pdf
    Reply  Tue Aug 25 18:42:42 2009, steve, Update, PSL, reference cavity temp box temporarly out of order 
    Reply  Tue Aug 25 21:36:28 2009, Alberto, Update, PSL, reference cavity temp box temporarly out of order 2009-08-25_PSLtrend.png
ELOG V3.1.3-